Engineering Chemistry: Water Technology and Hardness of Water

Global Distribution of Water Resources

Water is distributed across Earth's reservoirs in distinct proportions:

  • Oceans (Saltwater): Account for 97.5%97.5\% of all water on Earth.

  • Freshwater: Represents the remaining 2.5%2.5\% of Earth's total water inventory. Freshwater is distributed as follows:

    • Ice caps and glaciers: 79%79\% of total freshwater.

    • Groundwater: 20%20\% of total freshwater.

    • Other Freshwater Sources: 1%1\% of total freshwater, which includes:

    • Water in lakes: 52%52\%

    • Water in soil: 38%38\%

    • Water vapor in atmosphere: Minor fraction

    • Water in rivers: Minor fraction

    • Water in living organisms: Minor fraction

Global Distribution of Water Resources

Fundamentals of Hardness in Water

Water is classified into soft water and hard water depending on its behavior with soap and its chemical composition.

  • Soft Water:

    • Soft water produces abundant lather easily when treated with soap and consumes very little soap.

    • This property is due to the complete absence of dissolved salts of calcium (Ca2+\text{Ca}^{2+}) and magnesium (Mg2+\text{Mg}^{2+}).

    • Examples: Rainwater, distilled water, demineralized water.

    • Soap action in soft water:     C17H35COONa+H2O→NaOH+C17H35COOH\text{C}_{17}\text{H}_{35}\text{COONa} + \text{H}_2\text{O} \rightarrow \text{NaOH} + \text{C}_{17}\text{H}_{35}\text{COOH}

  • Hard Water:

    • Hard water does not produce good lather or foam with soap; instead, it consumes a large quantity of soap and forms an insoluble white precipitate or scum.

    • Primary Cause: Presence of dissolved bicarbonates, chlorides, and sulfates of calcium (Ca2+\text{Ca}^{2+}) and magnesium (Mg2+\text{Mg}^{2+}).

    • Secondary Contributors: Heavy metal cations such as iron (Fe2+\text{Fe}^{2+}), manganese (Mn2+\text{Mn}^{2+}), aluminum (Al3+\text{Al}^{3+}), and strontium (Sr2+\text{Sr}^{2+}) also contribute to hardness, though they are usually present only in trace quantities.

    • Mechanism of Soap Consumption: Soap consists of sodium salts of long-chain fatty acids, such as sodium stearate (C17H35COONa\text{C}_{17}\text{H}_{35}\text{COONa}), sodium oleate, and sodium palmitate. Calcium and magnesium ions react with sodium stearate to precipitate insoluble calcium and magnesium stearate scums:     2 C17H35COONa+CaCl2→(C17H35COO)2Ca↓+2 NaCl2\,\text{C}_{17}\text{H}_{35}\text{COONa} + \text{CaCl}_2 \rightarrow (\text{C}_{17}\text{H}_{35}\text{COO})_2\text{Ca}\downarrow + 2\,\text{NaCl}     2 C17H35COONa+MgSO4→(C17H35COO)2Mg↓+Na2SO42\,\text{C}_{17}\text{H}_{35}\text{COONa} + \text{MgSO}_4 \rightarrow (\text{C}_{17}\text{H}_{35}\text{COO})_2\text{Mg}\downarrow + \text{Na}_2\text{SO}_4

Classification and Types of Water Hardness

Hardness of water is categorized into temporary hardness and permanent hardness based on the anion associated with the metal cations and the method required for removal.

Classification of Water Hardness
  • Temporary Hardness (Carbonate Hardness):

    • Caused by the presence of dissolved bicarbonates of calcium, magnesium, and heavy metal ions: Ca(HCO3)2\text{Ca(HCO}_3)_2 and Mg(HCO3)2\text{Mg(HCO}_3)_2.

    • Removal Process: Temporary hardness is easily destroyed by boiling water. Thermal decomposition converts soluble bicarbonates into insoluble carbonates or hydroxides, which deposit at the bottom of the vessel:     Ca(HCO3)2→ΔCaCO3↓+CO2↑+H2O\text{Ca(HCO}_3)_2 \xrightarrow{\Delta} \text{CaCO}_3\downarrow + \text{CO}_2\uparrow + \text{H}_2\text{O}     Mg(HCO3)2→Δx MgCO3⋅y Mg(OH)2⋅z H2O+a MgO+b H2O+c CO2\text{Mg(HCO}_3)_2 \xrightarrow{\Delta} x\,\text{MgCO}_3 \cdot y\,\text{Mg(OH)}_2 \cdot z\,\text{H}_2\text{O} + a\,\text{MgO} + b\,\text{H}_2\text{O} + c\,\text{CO}_2     (Where coefficients x,y,z,a,b,cx, y, z, a, b, c depend on thermal decomposition conditions. Simplified complete precipitation yields Mg(OH)2↓+2 CO2↑\text{Mg(OH)}_2\downarrow + 2\,\text{CO}_2\uparrow).

  • Permanent Hardness (Non-Carbonate Hardness):

    • Caused by the presence of chlorides, sulfates, and nitrates of calcium, magnesium, iron, and other heavy metal ions: CaCl2\text{CaCl}_2, MgCl2\text{MgCl}_2, CaSO4\text{CaSO}_4, MgSO4\text{MgSO}_4, FeSO4\text{FeSO}_4, and Al2(SO4)3\text{Al}_2(\text{SO}_4)_3.

    • Permanent hardness cannot be destroyed by boiling; chemical or ion-exchange softening techniques are required.

Quantitative Measurement and Calcium Carbonate Equivalent

Hardness is standardly expressed in terms of equivalent of Calcium Carbonate (CaCO3\text{CaCO}_3). CaCO3\text{CaCO}_3 is chosen as the standard unit for two fundamental reasons:

  1. Its molar mass is exactly 100 g/mol100\,\text{g/mol} and chemical equivalent weight is 50 g/eq50\,\text{g/eq}, simplifying mathematical calculations.

  2. It is an insoluble salt that can be most easily precipitated in water treatment operations.

  • General Formula for Calcium Carbonate Equivalent:   Equivalent of CaCO3=Mass of salt×Equivalent weight of CaCO3 (50)Equivalent weight of salt\text{Equivalent of CaCO}_3 = \text{Mass of salt} \times \frac{\text{Equivalent weight of CaCO}_3\,(50)}{\text{Equivalent weight of salt}}   Equivalent of CaCO3=Mass of salt×Molecular weight of CaCO3 (100)Molecular weight of salt\text{Equivalent of CaCO}_3 = \text{Mass of salt} \times \frac{\text{Molecular weight of CaCO}_3\,(100)}{\text{Molecular weight of salt}}

  • Chemical Parameters and Conversion Factors Table:

Dissolved Salt / Impurity Ion

Molar Mass (g/mol\text{g/mol})

Chemical Equivalent (g/eq\text{g/eq})

Multiplication Factor for Converting into CaCO3\text{CaCO}_3 Equivalent

Ca(HCO3)2\text{Ca(HCO}_3)_2

162162

8181

100162\frac{100}{162}

Mg(HCO3)2\text{Mg(HCO}_3)_2

146146

7373

100146\frac{100}{146}

CaSO4\text{CaSO}_4

136136

6868

100136\frac{100}{136}

CaCl2\text{CaCl}_2

111111

55.555.5

100111\frac{100}{111}

MgSO4\text{MgSO}_4

120120

6060

100120\frac{100}{120}

MgCl2\text{MgCl}_2

9595

47.547.5

10095\frac{100}{95}

MgCO3\text{MgCO}_3

8484

4242

10084\frac{100}{84}

Ca2+\text{Ca}^{2+}

4040

2020

10040\frac{100}{40}

Mg2+\text{Mg}^{2+}

2424

1212

10024\frac{100}{24}

HCO3−\text{HCO}_3^-

6161

6161

100122\frac{100}{122}

H+\text{H}^+

11

11

1002\frac{100}{2}

CO2\text{CO}_2

4444

2222

10044\frac{100}{44}

Units of Hardness and Unit Conversions

Hardness is quantified across four standard scientific and industrial units:

  • Parts per million (ppm): Parts of CaCO3\text{CaCO}_3 equivalent hardness per 10610^6 parts of water.

  • Milligrams per liter (mg/L): Number of milligrams of CaCO3\text{CaCO}_3 equivalent hardness per liter of water. Since 1 L1\,\text{L} of water weighs 103 g=106 mg10^3\,\text{g} = 10^6\,\text{mg}, 1 mg/L1\,\text{mg/L} is equivalent to 1 ppm1\,\text{ppm}.

  • Degree Clark (∘Cl^\circ\text{Cl}): Parts of CaCO3\text{CaCO}_3 equivalent hardness per 70,00070,000 parts of water.

  • Degree French (∘Fr^\circ\text{Fr}): Parts of CaCO3\text{CaCO}_3 equivalent hardness per 10510^5 parts of water.

  • Interrelationship Equation:   1 ppm=1 mg/L=0.1∘Fr=0.07∘Cl1\,\text{ppm} = 1\,\text{mg/L} = 0.1^\circ\text{Fr} = 0.07^\circ\text{Cl}   1∘Cl=14.254 ppm  ⟹  1 mg/L=0.07∘Cl1^\circ\text{Cl} = 14.254\,\text{ppm} \implies 1\,\text{mg/L} = 0.07^\circ\text{Cl}   1∘Fr=10 ppm  ⟹  1 mg/L=0.1∘Fr1^\circ\text{Fr} = 10\,\text{ppm} \implies 1\,\text{mg/L} = 0.1^\circ\text{Fr}

Complexometric Determination of Hardness by EDTA Titration

  • Principle: Water hardness is determined by complexometric titration using the disodium salt of Ethylene Diamine Tetraacetic Acid (EDTA) as a titrant and Eriochrome Black-T (EBT) as a metal-ion indicator at a buffered pH\text{pH} of 9.0−10.09.0 - 10.0.

  • Role of Basic Buffer Solution:

    • EDTA is a weak, non-dissociated polyprotic hexadentate acid ligand containing 2 nitrogen donor lone pairs and 4 carboxylate groups (−COO−-\text{COO}^-).

    • An ammonium buffer solution (NH4Cl+NH4OH\text{NH}_4\text{Cl} + \text{NH}_4\text{OH}) maintains pH=10.0\text{pH} = 10.0. This alkaline medium promotes the deprotonation of EDTA into charged ionic forms capable of binding metal cations securely.

  • Indicator Reaction and Color Transition:

    • Initially, EBT indicator (which is blue in its free form at pH=10\text{pH} = 10) is added to hard water. It combines weakly with Ca2+\text{Ca}^{2+} and Mg2+\text{Mg}^{2+} ions to form an unstable wine-red complex:     (Ca2+ or Mg2+)+EBT (Blue)→[Ca-EBT/Mg-EBT] (Unstable Wine-Red Complex)(\text{Ca}^{2+} \text{ or } \text{Mg}^{2+}) + \text{EBT (Blue)} \rightarrow [\text{Ca-EBT} / \text{Mg-EBT}] \text{ (Unstable Wine-Red Complex)}

    • During titration, EDTA is added from the burette. EDTA forms much stronger, highly stable, colorless chelate complexes with Ca2+\text{Ca}^{2+} and Mg2+\text{Mg}^{2+}, replacing EBT:     [Ca-EBT/Mg-EBT]+EDTA→[Ca-EDTA/Mg-EDTA] (Stable Colorless Complex)+EBT (Free Blue Indicator)[\text{Ca-EBT} / \text{Mg-EBT}] + \text{EDTA} \rightarrow [\text{Ca-EDTA} / \text{Mg-EDTA}] \text{ (Stable Colorless Complex)} + \text{EBT (Free Blue Indicator)}

    • End Point: Sharp color change from Wine-Red to Clear Blue.

  • Detailed Analytical Procedure:

    1. Standardization of EDTA Solution:

    • Dissolve 1.0 g1.0\,\text{g} pure CaCO3\text{CaCO}_3 in dilute HCl\text{HCl} and dilute to 1000 mL1000\,\text{mL} with distilled water to prepare Standard Hard Water (M1=0.01 MM_1 = 0.01\,\text{M} or 1 mg/mL1\,\text{mg/mL} CaCO3\text{CaCO}_3).

    • Pipette out V1 mLV_1\,\text{mL} (50 mL50\,\text{mL}) of Standard Hard Water into a conical flask. Add 4−5 mL4-5\,\text{mL} buffer solution (pH=10\text{pH}=10) and 2 drops of EBT indicator.

    • Titrate with EDTA solution until the wine-red color turns clear blue (titre value V2 mLV_2\,\text{mL}).

    • Calculate EDTA Molarity (M2M_2):        M1⋅V1=M2⋅V2  ⟹  M2=M1⋅V1V2M_1 \cdot V_1 = M_2 \cdot V_2 \implies M_2 = \frac{M_1 \cdot V_1}{V_2}

    1. Determination of Total Hardness:

    • Pipette out V3 mLV_3\,\text{mL} (50 mL50\,\text{mL}) of unknown hard water sample into a conical flask.

    • Add 4−5 mL4-5\,\text{mL} buffer solution and 2 drops of EBT indicator. Titrate with standardized EDTA to clear blue (titre value V4 mLV_4\,\text{mL}).

    • Calculate Molarity (M3M_3) and Total Hardness:        M3=M2⋅V4V3M_3 = \frac{M_2 \cdot V_4}{V_3}        Total Hardness=M3×100 (M.W. of CaCO3)×1000 (mL/L)=M3×105 ppm\text{Total Hardness} = M_3 \times 100 \, (\text{M.W. of CaCO}_3) \times 1000 \, (\text{mL/L}) = M_3 \times 10^5\,\text{ppm}

    1. Determination of Permanent Hardness:

    • Take 100 mL100\,\text{mL} of sample water in a beaker and boil it gently down to approximately half volume (50 mL50\,\text{mL}) to decompose temporary bicarbonates into insoluble carbonates.

    • Cool to room temperature, filter through filter paper to remove insoluble precipitates, and restore the volume back to original 100 mL100\,\text{mL} using distilled water.

    • Pipette out V3 mLV_3\,\text{mL} of this permanent hard water, add buffer and indicator, and titrate against EDTA to blue end point (titre value V4′ mLV_4'\,\text{mL}).

    • Calculate Molarity (M4M_4) and Permanent Hardness:        M4=M2⋅V4′V3M_4 = \frac{M_2 \cdot V_4'}{V_3}        Permanent Hardness=M4×105 ppm\text{Permanent Hardness} = M_4 \times 10^5\,\text{ppm}

    1. Determination of Temporary Hardness:      Temporary Hardness=Total Hardness−Permanent Hardness\text{Temporary Hardness} = \text{Total Hardness} - \text{Permanent Hardness}

Overview of Water Softening Methods

Water softening techniques are broadly classified into External Treatment and Internal Treatment methods.

Classification of Water Softening Processes
  • External Treatment: Treatment of raw water prior to entering boilers or supply lines. Includes:

    • Lime-Soda Process

    • Zeolite Process

    • Ion-Exchange (Demineralization) Process

  • Internal Treatment: Conditioning chemicals added directly inside boilers to prevent scale deposition. Includes:

    • Colloidal Conditioning

    • Carbonate Conditioning

    • Phosphate Conditioning

    • Calgon Conditioning

External Treatment: Lime-Soda Process

  • Principle: Calculated quantities of slaked lime [Ca(OH)2\text{Ca(OH)}_2] and soda ash [Na2CO3\text{Na}_2\text{CO}_3] are added to hard water to precipitate soluble calcium and magnesium salts as insoluble CaCO3↓\text{CaCO}_3\downarrow and Mg(OH)2↓\text{Mg(OH)}_2\downarrow.

  • Chemical Reactions for Lime and Soda Requirements:

    • Removal of Temporary Calcium Hardness:     Ca(HCO3)2+Ca(OH)2→2 CaCO3↓+2 H2O(Requires 1 Lime)\text{Ca(HCO}_3)_2 + \text{Ca(OH)}_2 \rightarrow 2\,\text{CaCO}_3\downarrow + 2\,\text{H}_2\text{O} \quad (\text{Requires 1 Lime})

    • Removal of Temporary Magnesium Hardness:     Mg(HCO3)2+2 Ca(OH)2→Mg(OH)2↓+2 CaCO3↓+2 H2O(Requires 2 Lime)\text{Mg(HCO}_3)_2 + 2\,\text{Ca(OH)}_2 \rightarrow \text{Mg(OH)}_2\downarrow + 2\,\text{CaCO}_3\downarrow + 2\,\text{H}_2\text{O} \quad (\text{Requires 2 Lime})

    • Removal of Permanent Calcium Hardness:     CaCl2+Na2CO3→CaCO3↓+2 NaCl(Requires 1 Soda)\text{CaCl}_2 + \text{Na}_2\text{CO}_3 \rightarrow \text{CaCO}_3\downarrow + 2\,\text{NaCl} \quad (\text{Requires 1 Soda})     CaSO4+Na2CO3→CaCO3↓+Na2SO4(Requires 1 Soda)\text{CaSO}_4 + \text{Na}_2\text{CO}_3 \rightarrow \text{CaCO}_3\downarrow + \text{Na}_2\text{SO}_4 \quad (\text{Requires 1 Soda})

    • Removal of Permanent Magnesium Hardness:     MgCl2+Ca(OH)2→Mg(OH)2↓+CaCl2(Requires 1 Lime)\text{MgCl}_2 + \text{Ca(OH)}_2 \rightarrow \text{Mg(OH)}_2\downarrow + \text{CaCl}_2 \quad (\text{Requires 1 Lime})     CaCl2+Na2CO3→CaCO3↓+2 NaCl(Requires 1 Soda)\text{CaCl}_2 + \text{Na}_2\text{CO}_3 \rightarrow \text{CaCO}_3\downarrow + 2\,\text{NaCl} \quad (\text{Requires 1 Soda})     MgSO4+Ca(OH)2→Mg(OH)2↓+CaSO4(Requires 1 Lime)\text{MgSO}_4 + \text{Ca(OH)}_2 \rightarrow \text{Mg(OH)}_2\downarrow + \text{CaSO}_4 \quad (\text{Requires 1 Lime})     CaSO4+Na2CO3→CaCO3↓+Na2SO4(Requires 1 Soda)\text{CaSO}_4 + \text{Na}_2\text{CO}_3 \rightarrow \text{CaCO}_3\downarrow + \text{Na}_2\text{SO}_4 \quad (\text{Requires 1 Soda})     (\text{Permanent Mg requires } 1 \text{ Lime} + 1 \text{ Soda}).

    • Removal of Free Dissolved Carbon Dioxide and Hydrogen Sulfide:     CO2+Ca(OH)2→CaCO3↓+H2O(Requires 1 Lime)\text{CO}_2 + \text{Ca(OH)}_2 \rightarrow \text{CaCO}_3\downarrow + \text{H}_2\text{O} \quad (\text{Requires 1 Lime})     H2S+Ca(OH)2→CaS↓+2 H2O(Requires 1 Lime)\text{H}_2\text{S} + \text{Ca(OH)}_2 \rightarrow \text{CaS}\downarrow + 2\,\text{H}_2\text{O} \quad (\text{Requires 1 Lime})

    • Removal of Free Mineral Acids (HCl\text{HCl}, H2SO4\text{H}_2\text{SO}_4):     2 HCl+Ca(OH)2→CaCl2+2 H2O(Creates CaCl2)2\,\text{HCl} + \text{Ca(OH)}_2 \rightarrow \text{CaCl}_2 + 2\,\text{H}_2\text{O} \quad (\text{Creates } \text{CaCl}_2)     CaCl2+Na2CO3→CaCO3↓+2 NaCl(Requires 1 Soda)\text{CaCl}_2 + \text{Na}_2\text{CO}_3 \rightarrow \text{CaCO}_3\downarrow + 2\,\text{NaCl} \quad (\text{Requires 1 Soda})     (\text{Free mineral acids require } 1 \text{ Lime} + 1 \text{ Soda}).

    • Removal of Bicarbonate Ions (HCO3−\text{HCO}_3^- e.g., NaHCO3\text{NaHCO}_3):     2 HCO3−+Ca(OH)2→CaCO3↓+H2O+CO32−(Requires L−S)2\,\text{HCO}_3^- + \text{Ca(OH)}_2 \rightarrow \text{CaCO}_3\downarrow + \text{H}_2\text{O} + \text{CO}_3^{2-} \quad (\text{Requires } L - S)

    • Removal of Iron and Aluminum Salts:     FeSO4+Ca(OH)2→Fe(OH)2↓+CaSO4(Requires L+S)\text{FeSO}_4 + \text{Ca(OH)}_2 \rightarrow \text{Fe(OH)}_2\downarrow + \text{CaSO}_4 \quad (\text{Requires } L + S)     Al2(SO4)3+3 Ca(OH)2→2 Al(OH)3↓+3 CaSO4(Requires 3(L+S))\text{Al}_2(\text{SO}_4)_3 + 3\,\text{Ca(OH)}_2 \rightarrow 2\,\text{Al(OH)}_3\downarrow + 3\,\text{CaSO}_4 \quad (\text{Requires } 3(L + S))

  • Role of Coagulants in Cold Lime-Soda Process:

    • Precipitates formed at ambient temperature are finely divided colloidal particles that settle slowly.

    • Coagulants like sodium aluminate (NaAlO2\text{NaAlO}_2) or alum [Al2(SO4)3\text{Al}_2(\text{SO}_4)_3] are added to form gelatinous hydroxides that entrap precipitates:     NaAlO2+2 H2O→NaOH+Al(OH)3↓\text{NaAlO}_2 + 2\,\text{H}_2\text{O} \rightarrow \text{NaOH} + \text{Al(OH)}_3\downarrow     Al2(SO4)3+3 Ca(HCO3)2→2 Al(OH)3↓+3 CaSO4+6 CO2↑\text{Al}_2(\text{SO}_4)_3 + 3\,\text{Ca(HCO}_3)_2 \rightarrow 2\,\text{Al(OH)}_3\downarrow + 3\,\text{CaSO}_4 + 6\,\text{CO}_2\uparrow

  • Lime and Soda Requirement Formulae:

  Lime Requirement (kg)=74100[Temp Ca2++2×Temp Mg2++Perm (Mg2++Fe2++Al3+)+CO2+H++HCO3−−NaAlO2]×Volume in L106×100% Purity\text{Lime Requirement (kg)} = \frac{74}{100} \left[ \text{Temp } \text{Ca}^{2+} + 2 \times \text{Temp } \text{Mg}^{2+} + \text{Perm } (\text{Mg}^{2+} + \text{Fe}^{2+} + \text{Al}^{3+}) + \text{CO}_2 + \text{H}^+ + \text{HCO}_3^- - \text{NaAlO}_2 \right] \times \frac{\text{Volume in L}}{10^6} \times \frac{100}{\% \text{ Purity}}

  Soda Requirement (kg)=106100[Perm (Ca2++Mg2++Fe2++Al3+)+H+−HCO3−−NaAlO2]×Volume in L106×100% Purity\text{Soda Requirement (kg)} = \frac{106}{100} \left[ \text{Perm } (\text{Ca}^{2+} + \text{Mg}^{2+} + \text{Fe}^{2+} + \text{Al}^{3+}) + \text{H}^+ - \text{HCO}_3^- - \text{NaAlO}_2 \right] \times \frac{\text{Volume in L}}{10^6} \times \frac{100}{\% \text{ Purity}}   (Note: All constituent quantities inside brackets must be expressed in terms of CaCO3\text{CaCO}_3 equivalents).

  • Lime-Soda Process Equipment:

    • Continuous Cold Lime-Soda Softener: Operates at room temperature; requires coagulants and wood fiber filter media.     

      Continuous Cold Lime Soda Softener Diagram
    • Continuous Hot Lime-Soda Process: Operates at 80∘C80^\circ\text{C} using superheated steam.     

      Continuous Hot Lime Soda Softener Diagram
    • Advantages of Hot Process: Reaction rates increase dramatically, softening capacity is higher, coagulants are unnecessary because sludge precipitates settle rapidly, dissolved gases are expelled, viscosity decreases making filtration easy, and residual hardness is lower (15−30 ppm15 - 30\,\text{ppm}).

  • Advantages of Lime-Soda Process: Highly economical, reduces total dissolved minerals, raises pH\text{pH} reducing corrosion, reduces pathogenic bacteria counts due to high alkalinity.

  • Disadvantages: Demands skilled supervision, creates large volumes of sludge causing disposal issues, residual hardness (15 ppm15\,\text{ppm}) is too high for high-pressure boilers, leaves soluble sodium salts (Na2SO4\text{Na}_2\text{SO}_4) in water.

External Treatment: Zeolite (Permutit) Process

  • Principle: Zeolite is Hydrated Sodium Alumino Silicate (HSAS) with general chemical formula:   Na2O⋅Al2O3⋅x SiO2⋅y H2O(x=2−10,y=2−6)\text{Na}_2\text{O} \cdot \text{Al}_2\text{O}_3 \cdot x\,\text{SiO}_2 \cdot y\,\text{H}_2\text{O} \quad (x = 2-10, y = 2-6)   It possesses a porous structure with cavities capable of reversibly exchanging sodium ions (Na+\text{Na}^+) for hardness-causing cations (Ca2+\text{Ca}^{2+}, Mg2+\text{Mg}^{2+}).

Zeolite Softener System Diagram
  • Softening Reactions:   Na2Ze+CaCl2→CaZe+2 NaCl\text{Na}_2\text{Ze} + \text{CaCl}_2 \rightarrow \text{CaZe} + 2\,\text{NaCl}   Na2Ze+MgSO4→MgZe+Na2SO4\text{Na}_2\text{Ze} + \text{MgSO}_4 \rightarrow \text{MgZe} + \text{Na}_2\text{SO}_4   Na2Ze+Ca(HCO3)2→CaZe+2 NaHCO3\text{Na}_2\text{Ze} + \text{Ca(HCO}_3)_2 \rightarrow \text{CaZe} + 2\,\text{NaHCO}_3   Na2Ze+Mg(HCO3)2→MgZe+2 NaHCO3\text{Na}_2\text{Ze} + \text{Mg(HCO}_3)_2 \rightarrow \text{MgZe} + 2\,\text{NaHCO}_3

  • Regeneration Process:

    • When the bed becomes exhausted (CaZe\text{CaZe} and MgZe\text{MgZe}), it is regenerated by passing a 10%10\% concentrated sodium chloride (NaCl\text{NaCl}) brine solution:     CaZe/MgZe+2 NaCl→Na2Ze+CaCl2/MgCl2\text{CaZe} / \text{MgZe} + 2\,\text{NaCl} \rightarrow \text{Na}_2\text{Ze} + \text{CaCl}_2 / \text{MgCl}_2

    • Washings containing soluble CaCl2\text{CaCl}_2 and MgCl2\text{MgCl}_2 are washed to drain.

  • Calculation Formula for Zeolite Regeneration:   Hardness of Water (ppm)=5058.5×Mass of NaCl consumed (g)Volume of hard water softened (L)×1000\text{Hardness of Water (ppm)} = \frac{50}{58.5} \times \frac{\text{Mass of NaCl consumed (g)}}{\text{Volume of hard water softened (L)}} \times 1000

  • Limitations: Turbid water clogs zeolite pores; manganese (Mn2+\text{Mn}^{2+}) and iron (Fe2+\text{Fe}^{2+}) form irreversible complexes; acidic water destroys zeolite structure.

  • Advantages: Produces soft water with low residual hardness (10−15 ppm10 - 15\,\text{ppm}), compact equipment, clean operation without sludge formation.

  • Disadvantages: Leaves high sodium ion concentration in water; leaves bicarbonates (HCO3−\text{HCO}_3^-) unaffected which decompose upon heating to generate CO2\text{CO}_2 (corrosion) and Na2CO3\text{Na}_2\text{CO}_3 (causing caustic embrittlement).

External Treatment: Ion-Exchange (Demineralization) Process

  • Principle: Water is passed sequentially through cross-linked, long-chain insoluble organic polymers (e.g., styrene-divinylbenzene copolymers) containing ionizable micro-porous functional groups.

Cation and Anion Exchange Columns Deionization Process
  • 1. Cation Exchange Resins (RH+R\text{H}^+):

    • Contain acidic groups (−SO3H-\text{SO}_3\text{H}, −COOH-\text{COOH}, phenolic −OH-\text{OH}). Examples: Amberlite IR-120, Dowex-50.

    • Softening Reaction:     2 RH++Ca2+→R2Ca2++2 H+2\,R\text{H}^+ + \text{Ca}^{2+} \rightarrow R_2\text{Ca}^{2+} + 2\,\text{H}^+     2 RH++Mg2+→R2Mg2++2 H+2\,R\text{H}^+ + \text{Mg}^{2+} \rightarrow R_2\text{Mg}^{2+} + 2\,\text{H}^+

    • Effect on pH: Water treated only through a cation exchange column contains excess H+\text{H}^+ ions, making its pH<7\text{pH} < 7 (acidic).

    • Regeneration: Regenerated using dilute acid (HCl\text{HCl} or H2SO4\text{H}_2\text{SO}_4):     R2Ca2++2 HCl→2 RH++CaCl2R_2\text{Ca}^{2+} + 2\,\text{HCl} \rightarrow 2\,R\text{H}^+ + \text{CaCl}_2

  • 2. Anion Exchange Resins (R+OH−R^+\text{OH}^-):

    • Contain basic functional groups (quaternary ammonium −NR3+OH−-N\text{R}_3^+\text{OH}^-, quaternary phosphonium, or tertiary sulfonium groups).

    • Softening Reaction:     R+OH−+Cl−→R+Cl−+OH−R^+\text{OH}^- + \text{Cl}^- \rightarrow R^+\text{Cl}^- + \text{OH}^-     2 R+OH−+SO42−→R22+SO42−+2 OH−2\,R^+\text{OH}^- + \text{SO}_4^{2-} \rightarrow R_2^{2+}\text{SO}_4^{2-} + 2\,\text{OH}^-

    • Neutralization: Released H+\text{H}^+ and OH−\text{OH}^- combine to form pure water:     H++OH−→H2O\text{H}^+ + \text{OH}^- \rightarrow \text{H}_2\text{O}

    • Regeneration: Regenerated using dilute alkali (NaOH\text{NaOH} or KOH\text{KOH}):     R22+SO42−+2 NaOH→2 R+OH−+Na2SO4R_2^{2+}\text{SO}_4^{2-} + 2\,\text{NaOH} \rightarrow 2\,R^+\text{OH}^- + \text{Na}_2\text{SO}_4

  • Advantages: Removes all ions completely producing zero hardness water; handles acidic or alkaline feed waters.

  • Disadvantages: High equipment and chemical costs; feed turbidity must be strictly under 10 ppm10\,\text{ppm}.

Internal Treatment Methods for Boiler Feed Water

Internal conditioning converts scale-forming salts into soft soluble compounds or non-adherent sludges directly inside boilers:

  • Colloidal Conditioning:

    • Conditioning agents like glue, seaweed extract, agar-agar, or tannin are added to boiler water.

    • These organic colloids coat individual scale precipitates, keeping them dispersed as a non-sticky colloidal suspension easily removed via blow-down operations.

  • Phosphate Conditioning:

    • Sodium phosphate reagents react with calcium ions to yield soft, non-adherent calcium phosphate sludge:     3 CaCl2+2 Na3PO4→Ca3(PO4)2↓+6 NaCl3\,\text{CaCl}_2 + 2\,\text{Na}_3\text{PO}_4 \rightarrow \text{Ca}_3(\text{PO}_4)_2\downarrow + 6\,\text{NaCl}

    • Selection of Phosphate Reagent based on Boiler Water pH / Alkalinity:

    • Trisodium Phosphate (Na3PO4\text{Na}_3\text{PO}_4): Used for low alkalinity water (pH≈6\text{pH} \approx 6).

    • Disodium Phosphate (Na2HPO4\text{Na}_2\text{HPO}_4): Used for moderate/sufficient alkalinity water (pH≈7\text{pH} \approx 7).

    • Monosodium Phosphate (NaH2PO4\text{NaH}_2\text{PO}_4): Used for highly alkaline water (pH≈8\text{pH} \approx 8).

  • Calgon Conditioning:

    • Involves adding Calgon—Sodium Hexametaphosphate [(NaPO<em>3)6 or Na6P6O</em>18][(\text{NaPO}<em>3)_6 \text{ or } \text{Na}_6\text{P}_6\text{O}</em>{18}].

    • Calgon ionizes: Na6P6O18→2 Na++[Na4P6O18]2−\text{Na}_6\text{P}_6\text{O}_{18} \rightarrow 2\,\text{Na}^+ + [\text{Na}_4\text{P}_6\text{O}_{18}]^{2-}

    • It forms a highly soluble complex anion with calcium sulfate, preventing scale precipitation:     2 CaSO4+[Na4P6O18]2−→[Ca2P6O18]2−+2 Na2SO42\,\text{CaSO}_4 + [\text{Na}_4\text{P}_6\text{O}_{18}]^{2-} \rightarrow [\text{Ca}_2\text{P}_6\text{O}_{18}]^{2-} + 2\,\text{Na}_2\text{SO}_4

Boiler Issues, De-oxygenation, Caustic Embrittlement, and Corrosion Types

  • Dissolved Oxygen Removal (Chemical De-aeration):

    • Dissolved oxygen causes severe pitting corrosion in boiler tubes.

    • Reducing Agents Added:

    • Sodium Sulphite: 2 Na2SO3+O2→2 Na2SO42\,\text{Na}_2\text{SO}_3 + \text{O}_2 \rightarrow 2\,\text{Na}_2\text{SO}_4

    • Hydrazine: N2H4+O2→N2↑+2 H2O\text{N}_2\text{H}_4 + \text{O}_2 \rightarrow \text{N}_2\uparrow + 2\,\text{H}_2\text{O}

  • Caustic Embrittlement:

    • A form of stress corrosion cracking occurring in mild steel boilers under high temperature, pressure, and stress.

    • Mechanism: In high-alkalinity water, residual Na2CO3\text{Na}_2\text{CO}_3 hydrolyzes:     Na2CO3+H2O→2 NaOH+CO2↑\text{Na}_2\text{CO}_3 + \text{H}_2\text{O} \rightarrow 2\,\text{NaOH} + \text{CO}_2\uparrow

    • Dilute alkaline water penetrates hair-cracks and crevices near rivets by capillary action. As steam escapes, NaOH\text{NaOH} accumulates to high concentration.

    • Concentrated NaOH\text{NaOH} attacks iron, forming sodium ferroate (Na2FeO2\text{Na}_2\text{FeO}_2):     Fe+2 NaOH→Na2FeO2+H2↑\text{Fe} + 2\,\text{NaOH} \rightarrow \text{Na}_2\text{FeO}_2 + \text{H}_2\uparrow

    • Sodium ferroate decomposes nearby, regenerating NaOH\text{NaOH} and depositing magnet-like scale (Fe3O4\text{Fe}_3\text{O}_4), causing brittleness and failure:     3 Na2FeO2+4 H2O→6 NaOH+Fe3O4+H2↑3\,\text{Na}_2\text{FeO}_2 + 4\,\text{H}_2\text{O} \rightarrow 6\,\text{NaOH} + \text{Fe}_3\text{O}_4 + \text{H}_2\uparrow     6 Na2FeO2+6 H2O+O2→12 NaOH+2 Fe3O46\,\text{Na}_2\text{FeO}_2 + 6\,\text{H}_2\text{O} + \text{O}_2 \rightarrow 12\,\text{NaOH} + 2\,\text{Fe}_3\text{O}_4

  • Corrosion Classification Examples:

    1. Steel nut with aluminum bolt: Galvanic Corrosion (dissimilar metals in contact).

    2. Iron tank filled half with water: Water-line Corrosion (differential oxygen concentration at meniscus).

    3. Steel pipe connected to copper plumbing: Galvanic Corrosion.

    4. Nail immersed in wood block: Differential Aeration Corrosion.

Solved Numerical Problems and Step-by-Step Practice Solutions

Problem 1: Basic Hardness and Fractionation

A water sample contains Ca(HCO3)2=8.1 mg/L\text{Ca(HCO}_3)_2 = 8.1\,\text{mg/L}, Mg(HCO3)2=29.2 mg/L\text{Mg(HCO}_3)_2 = 29.2\,\text{mg/L}, CaCl2=11.1 mg/L\text{CaCl}_2 = 11.1\,\text{mg/L}, and MgSO4=6.0 mg/L\text{MgSO}_4 = 6.0\,\text{mg/L}. Calculate temporary, permanent, and total hardness in mg/L.

  • Solution:

    • Hardness due to Ca(HCO3)2=8.1×100162=5.0 mg/L\text{Ca(HCO}_3)_2 = 8.1 \times \frac{100}{162} = 5.0\,\text{mg/L}

    • Hardness due to Mg(HCO3)2=29.2×100146=20.0 mg/L\text{Mg(HCO}_3)_2 = 29.2 \times \frac{100}{146} = 20.0\,\text{mg/L}

    • Hardness due to CaCl2=11.1×100111=10.0 mg/L\text{CaCl}_2 = 11.1 \times \frac{100}{111} = 10.0\,\text{mg/L}

    • Hardness due to MgSO4=6.0×100120=5.0 mg/L\text{MgSO}_4 = 6.0 \times \frac{100}{120} = 5.0\,\text{mg/L}

    • Temporary Hardness=5.0+20.0=25.0 mg/L\text{Temporary Hardness} = 5.0 + 20.0 = 25.0\,\text{mg/L}

    • Permanent Hardness=10.0+5.0=15.0 mg/L\text{Permanent Hardness} = 10.0 + 5.0 = 15.0\,\text{mg/L}

    • Total Hardness=25.0+15.0=40.0 mg/L\text{Total Hardness} = 25.0 + 15.0 = 40.0\,\text{mg/L}

Problem 2: Unit Conversions for Calcium Sulfate Solution

A water sample contains 200 mg200\,\text{mg} of CaSO4\text{CaSO}_4 per liter. Calculate the hardness in mg/L\text{mg/L}, ppm\text{ppm}, ∘Cl^\circ\text{Cl}, and ∘Fr^\circ\text{Fr}.

  • Solution:

    • Hardness in CaCO3 eq=200×100/2136/2=147.06 mg/L=147.06 ppm\text{Hardness in CaCO}_3 \text{ eq} = 200 \times \frac{100/2}{136/2} = 147.06\,\text{mg/L} = 147.06\,\text{ppm}

    • Hardness in ∘Cl=147.06×0.07=10.29∘Cl\text{Hardness in } ^\circ\text{Cl} = 147.06 \times 0.07 = 10.29^\circ\text{Cl}

    • Hardness in ∘Fr=147.06×0.10=14.71∘Fr\text{Hardness in } ^\circ\text{Fr} = 147.06 \times 0.10 = 14.71^\circ\text{Fr}

Problem 3: Standard EDTA Molarity and Total Hardness Determination

50 mL50\,\text{mL} of standard hard water containing 1.0 g1.0\,\text{g} pure CaCO3\text{CaCO}_3 per liter consumed 20 mL20\,\text{mL} of EDTA solution. 50 mL50\,\text{mL} of an unknown hard water sample consumed 25 mL25\,\text{mL} of the same EDTA solution. Calculate total hardness in ppm.

  • Solution:

    • Molarity of Standard Hard Water (M1M_1) = 1.0 g100 g/mol×1 L=0.01 M\frac{1.0\,\text{g}}{100\,\text{g/mol} \times 1\,\text{L}} = 0.01\,\text{M}

    • Molarity of EDTA (M2M_2) = V1⋅M1V2=50×0.0120=0.025 M\frac{V_1 \cdot M_1}{V_2} = \frac{50 \times 0.01}{20} = 0.025\,\text{M}

    • Molarity of Sample Water (M3M_3) = V2⋅M2V3=25×0.02550=0.0125 M\frac{V_2 \cdot M_2}{V_3} = \frac{25 \times 0.025}{50} = 0.0125\,\text{M}

    • Total Hardness=0.0125×105 ppm=1250 ppm\text{Total Hardness} = 0.0125 \times 10^5\,\text{ppm} = 1250\,\text{ppm}

Problem 4: EDTA Determination of Permanent and Temporary Hardness

0.28 g0.28\,\text{g} of CaCO3\text{CaCO}_3 was dissolved in HCl\text{HCl} and made up to 1.0 L1.0\,\text{L}. 100 mL100\,\text{mL} of this solution required 28 mL28\,\text{mL} of EDTA solution. 100 mL100\,\text{mL} of hard water sample consumed 33 mL33\,\text{mL} of EDTA solution. 100 mL100\,\text{mL} of boiled, cooled, and filtered sample required 10 mL10\,\text{mL} EDTA solution. Calculate permanent and temporary hardness in ppm.

  • Solution:

    • Molarity of SHW (M1M_1) = 0.28100=0.0028 M\frac{0.28}{100} = 0.0028\,\text{M}

    • Molarity of EDTA (M2M_2) = 100×0.002828=0.01 M\frac{100 \times 0.0028}{28} = 0.01\,\text{M}

    • Molarity of Sample Water (M3M_3) = 33×0.01100=0.0033 M\frac{33 \times 0.01}{100} = 0.0033\,\text{M}

    • Total Hardness=0.0033×105=330 ppm\text{Total Hardness} = 0.0033 \times 10^5 = 330\,\text{ppm}

    • Molarity of Boiled Water (M4M_4) = 10×0.01100=0.001 M\frac{10 \times 0.01}{100} = 0.001\,\text{M}

    • Permanent Hardness=0.001×105=100 ppm\text{Permanent Hardness} = 0.001 \times 10^5 = 100\,\text{ppm}

    • Temporary Hardness=330−100=230 ppm\text{Temporary Hardness} = 330 - 100 = 230\,\text{ppm}

Problem 5: Concentration Calculation from Hardness Threshold

How many grams of MgCl2\text{MgCl}_2 dissolved per liter of water will produce a hardness of 76 ppm76\,\text{ppm}?

  • Solution:

    • Let mass of MgCl2\text{MgCl}_2 be x mg/Lx\,\text{mg/L}.

    • x×10095=76  ⟹  x=76×95100=72.2 mg/L=0.0722 g/Lx \times \frac{100}{95} = 76 \implies x = \frac{76 \times 95}{100} = 72.2\,\text{mg/L} = 0.0722\,\text{g/L}

Problem 6: Comprehensive Multi-Ion Fractionation and Unit Conversion

A water sample contains Ca(HCO3)2=4 mg/L\text{Ca(HCO}_3)_2 = 4\,\text{mg/L}, Mg(HCO3)2=6 mg/L\text{Mg(HCO}_3)_2 = 6\,\text{mg/L}, CaSO4=8 mg/L\text{CaSO}_4 = 8\,\text{mg/L}, and MgSO4=10 mg/L\text{MgSO}_4 = 10\,\text{mg/L}. Calculate temporary, permanent, and total hardness in ppm, ∘Fr^\circ\text{Fr}, and ∘Cl^\circ\text{Cl}.

  • Solution:

    • Ca(HCO3)2 eq=4×100162=2.469 mg/L\text{Ca(HCO}_3)_2 \text{ eq} = 4 \times \frac{100}{162} = 2.469\,\text{mg/L}

    • Mg(HCO3)2 eq=6×100146=4.110 mg/L\text{Mg(HCO}_3)_2 \text{ eq} = 6 \times \frac{100}{146} = 4.110\,\text{mg/L}

    • CaSO4 eq=8×100136=5.882 mg/L\text{CaSO}_4 \text{ eq} = 8 \times \frac{100}{136} = 5.882\,\text{mg/L}

    • MgSO4 eq=10×100120=8.333 mg/L\text{MgSO}_4 \text{ eq} = 10 \times \frac{100}{120} = 8.333\,\text{mg/L}

    • Temporary Hardness=2.469+4.110=6.579 mg/L=6.579 ppm\text{Temporary Hardness} = 2.469 + 4.110 = 6.579\,\text{mg/L} = 6.579\,\text{ppm}

    • In ∘Fr=6.579×0.1=0.6579∘Fr^\circ\text{Fr} = 6.579 \times 0.1 = 0.6579^\circ\text{Fr}

    • In ∘Cl=6.579×0.07=0.4605∘Cl^\circ\text{Cl} = 6.579 \times 0.07 = 0.4605^\circ\text{Cl}

    • Permanent Hardness=5.882+8.333=14.215 mg/L=14.215 ppm\text{Permanent Hardness} = 5.882 + 8.333 = 14.215\,\text{mg/L} = 14.215\,\text{ppm}

    • In ∘Fr=14.215×0.1=1.4215∘Fr^\circ\text{Fr} = 14.215 \times 0.1 = 1.4215^\circ\text{Fr}

    • In ∘Cl=14.215×0.07=0.9950∘Cl^\circ\text{Cl} = 14.215 \times 0.07 = 0.9950^\circ\text{Cl}

    • Total Hardness=6.579+14.215=20.794 mg/L=20.794 ppm\text{Total Hardness} = 6.579 + 14.215 = 20.794\,\text{mg/L} = 20.794\,\text{ppm}

    • In ∘Fr=20.794×0.1=2.0794∘Fr^\circ\text{Fr} = 20.794 \times 0.1 = 2.0794^\circ\text{Fr}

    • In ∘Cl=20.794×0.07=1.4555∘Cl^\circ\text{Cl} = 20.794 \times 0.07 = 1.4555^\circ\text{Cl}

Problem 7: Lime-Soda Requirement with Pure Reagents

Calculate the quantities of lime and soda required for softening 18,000 L18,000\,\text{L} of water containing: Temporary Ca\text{Ca} hardness = 25 ppm25\,\text{ppm}, Permanent Ca\text{Ca} hardness = 20 ppm20\,\text{ppm}, and Permanent Mg\text{Mg} hardness = 15 ppm15\,\text{ppm}.

  • Solution:

    • Lime Requirement=74100[Temp Ca+Perm Mg]×Volume\text{Lime Requirement} = \frac{74}{100} [\text{Temp Ca} + \text{Perm Mg}] \times \text{Volume}     Lime Requirement=74100[25+15]×18,000=532,800 mg=532.8 g\text{Lime Requirement} = \frac{74}{100} [25 + 15] \times 18,000 = 532,800\,\text{mg} = 532.8\,\text{g}

    • Soda Requirement=106100[Perm Ca+Perm Mg]×Volume\text{Soda Requirement} = \frac{106}{100} [\text{Perm Ca} + \text{Perm Mg}] \times \text{Volume}     Soda Requirement=106100[20+15]×18,000=667,800 mg=667.8 g\text{Soda Requirement} = \frac{106}{100} [20 + 15] \times 18,000 = 667,800\,\text{mg} = 667.8\,\text{g}

Problem 8: Lime-Soda Requirement with Ions and Impurity Factors

A water sample contains: Ca2+=95 ppm\text{Ca}^{2+} = 95\,\text{ppm}, Mg2+=36 ppm\text{Mg}^{2+} = 36\,\text{ppm}, CO2=66 ppm\text{CO}_2 = 66\,\text{ppm}, HCO3−=244 ppm\text{HCO}_3^- = 244\,\text{ppm}, and H+=2 ppm\text{H}^+ = 2\,\text{ppm}. Calculate quantities of lime (74%74\% purity) and soda (92%92\% purity) required to soften 125,000 L125,000\,\text{L} of water.

  • Solution:

    • Convert concentrations to CaCO3\text{CaCO}_3 equivalents:

    • Ca2+=95×10040=237.5 ppm(S)\text{Ca}^{2+} = 95 \times \frac{100}{40} = 237.5\,\text{ppm} \quad (S)

    • Mg2+=36×10024=150.0 ppm(L+S)\text{Mg}^{2+} = 36 \times \frac{100}{24} = 150.0\,\text{ppm} \quad (L + S)

    • CO2=66×10044=150.0 ppm(L)\text{CO}_2 = 66 \times \frac{100}{44} = 150.0\,\text{ppm} \quad (L)

    • HCO3−=244×100122=200.0 ppm(L−S)\text{HCO}_3^- = 244 \times \frac{100}{122} = 200.0\,\text{ppm} \quad (L - S)

    • H+=2×1002=100.0 ppm(L+S)\text{H}^+ = 2 \times \frac{100}{2} = 100.0\,\text{ppm} \quad (L + S)

    • Lime Factor=[Mg2++CO2+HCO3−+H+]=[150+150+200+100]=600.0 ppm\text{Lime Factor} = [\text{Mg}^{2+} + \text{CO}_2 + \text{HCO}_3^- + \text{H}^+] = [150 + 150 + 200 + 100] = 600.0\,\text{ppm}     Lime Required=74100[600]×125,000×10074×10−6 kg=75.0 kg\text{Lime Required} = \frac{74}{100} [600] \times 125,000 \times \frac{100}{74} \times 10^{-6}\,\text{kg} = 75.0\,\text{kg}     (Or if purity is 74%74\%: Lime=56.25 kg\text{Lime} = 56.25\,\text{kg} depending on formula variant used).

    • Soda Factor=[Ca2++Mg2++H+−HCO3−]=[237.5+150+100−200]=287.5 ppm\text{Soda Factor} = [\text{Ca}^{2+} + \text{Mg}^{2+} + \text{H}^+ - \text{HCO}_3^-] = [237.5 + 150 + 100 - 200] = 287.5\,\text{ppm}     Soda Required=106100[287.5]×125,000×10092×10−6 kg=41.40 kg\text{Soda Required} = \frac{106}{100} [287.5] \times 125,000 \times \frac{100}{92} \times 10^{-6}\,\text{kg} = 41.40\,\text{kg}

Problem 9: Zeolite Softener Hardness Calculation from Effluent

1000 L1000\,\text{L} of hard water passed through a zeolite softener yielded effluent water containing 0.25 g/L0.25\,\text{g/L} of NaCl\text{NaCl}. Calculate the hardness of water.

  • Solution:

    • 58.5 g58.5\,\text{g} NaCl≡50 g\text{NaCl} \equiv 50\,\text{g} CaCO3\text{CaCO}_3

    • 0.25 g0.25\,\text{g} NaCl=5058.5×0.25=0.21367 g\text{NaCl} = \frac{50}{58.5} \times 0.25 = 0.21367\,\text{g} CaCO3/L\text{CaCO}_3\text{/L}

    • Hardness=0.21367 g/L=213.67 mg/L=213.67 ppm\text{Hardness} = 0.21367\,\text{g/L} = 213.67\,\text{mg/L} = 213.67\,\text{ppm}

Problem 10: Zeolite Regeneration Capacity

A zeolite softener completely softened 5000 L5000\,\text{L} of hard water. The bed required 55 L55\,\text{L} of NaCl\text{NaCl} solution containing 100 g/L100\,\text{g/L} NaCl\text{NaCl} for complete regeneration. Calculate hardness in ppm.

  • Solution:

    • Total mass of NaCl consumed=55 L×100 g/L=5500 g\text{Total mass of NaCl consumed} = 55\,\text{L} \times 100\,\text{g/L} = 5500\,\text{g}

    • 117 g117\,\text{g} NaCl≡100 g\text{NaCl} \equiv 100\,\text{g} CaCO3\text{CaCO}_3

    • CaCO3 equivalent=5500×100117=4700.85 g\text{CaCO}_3 \text{ equivalent} = 5500 \times \frac{100}{117} = 4700.85\,\text{g} CaCO3\text{CaCO}_3

    • Hardness per liter=4700.85 g5000 L=0.94017 g/L=940.17 ppm\text{Hardness per liter} = \frac{4700.85\,\text{g}}{5000\,\text{L}} = 0.94017\,\text{g/L} = 940.17\,\text{ppm}

    • (Note: Taking 2×58.5≈107 g2 \times 58.5 \approx 107\,\text{g} gives 5140.186 g  ⟹  1028 ppm5140.186\,\text{g} \implies 1028\,\text{ppm}).