Global Distribution of Water Resources
Water is distributed across Earth's reservoirs in distinct proportions:

Fundamentals of Hardness in Water
Water is classified into soft water and hard water depending on its behavior with soap and its chemical composition.
Soft Water:
Soft water produces abundant lather easily when treated with soap and consumes very little soap.
This property is due to the complete absence of dissolved salts of calcium (Ca2+) and magnesium (Mg2+).
Examples: Rainwater, distilled water, demineralized water.
Soap action in soft water: C17H35COONa+H2O→NaOH+C17H35COOH
Hard Water:
Hard water does not produce good lather or foam with soap; instead, it consumes a large quantity of soap and forms an insoluble white precipitate or scum.
Primary Cause: Presence of dissolved bicarbonates, chlorides, and sulfates of calcium (Ca2+) and magnesium (Mg2+).
Secondary Contributors: Heavy metal cations such as iron (Fe2+), manganese (Mn2+), aluminum (Al3+), and strontium (Sr2+) also contribute to hardness, though they are usually present only in trace quantities.
Mechanism of Soap Consumption: Soap consists of sodium salts of long-chain fatty acids, such as sodium stearate (C17H35COONa), sodium oleate, and sodium palmitate. Calcium and magnesium ions react with sodium stearate to precipitate insoluble calcium and magnesium stearate scums: 2C17H35COONa+CaCl2→(C17H35COO)2Ca↓+2NaCl 2C17H35COONa+MgSO4→(C17H35COO)2Mg↓+Na2SO4
Classification and Types of Water Hardness
Hardness of water is categorized into temporary hardness and permanent hardness based on the anion associated with the metal cations and the method required for removal.

Quantitative Measurement and Calcium Carbonate Equivalent
Hardness is standardly expressed in terms of equivalent of Calcium Carbonate (CaCO3). CaCO3 is chosen as the standard unit for two fundamental reasons:
Its molar mass is exactly 100g/mol and chemical equivalent weight is 50g/eq, simplifying mathematical calculations.
It is an insoluble salt that can be most easily precipitated in water treatment operations.
General Formula for Calcium Carbonate Equivalent: Equivalent of CaCO3=Mass of salt×Equivalent weight of saltEquivalent weight of CaCO3(50) Equivalent of CaCO3=Mass of salt×Molecular weight of saltMolecular weight of CaCO3(100)
Chemical Parameters and Conversion Factors Table:
Dissolved Salt / Impurity Ion | Molar Mass (g/mol) | Chemical Equivalent (g/eq) | Multiplication Factor for Converting into CaCO3 Equivalent |
|---|
Ca(HCO3)2 | 162 | 81 | 162100 |
Mg(HCO3)2 | 146 | 73 | 146100 |
CaSO4 | 136 | 68 | 136100 |
CaCl2 | 111 | 55.5 | 111100 |
MgSO4 | 120 | 60 | 120100 |
MgCl2 | 95 | 47.5 | 95100 |
MgCO3 | 84 | 42 | 84100 |
Ca2+ | 40 | 20 | 40100 |
Mg2+ | 24 | 12 | 24100 |
HCO3− | 61 | 61 | 122100 |
H+ | 1 | 1 | 2100 |
CO2 | 44 | 22 | 44100 |
Units of Hardness and Unit Conversions
Hardness is quantified across four standard scientific and industrial units:
Parts per million (ppm): Parts of CaCO3 equivalent hardness per 106 parts of water.
Milligrams per liter (mg/L): Number of milligrams of CaCO3 equivalent hardness per liter of water. Since 1L of water weighs 103g=106mg, 1mg/L is equivalent to 1ppm.
Degree Clark (∘Cl): Parts of CaCO3 equivalent hardness per 70,000 parts of water.
Degree French (∘Fr): Parts of CaCO3 equivalent hardness per 105 parts of water.
Interrelationship Equation: 1ppm=1mg/L=0.1∘Fr=0.07∘Cl 1∘Cl=14.254ppm⟹1mg/L=0.07∘Cl 1∘Fr=10ppm⟹1mg/L=0.1∘Fr
Complexometric Determination of Hardness by EDTA Titration
Principle: Water hardness is determined by complexometric titration using the disodium salt of Ethylene Diamine Tetraacetic Acid (EDTA) as a titrant and Eriochrome Black-T (EBT) as a metal-ion indicator at a buffered pH of 9.0−10.0.
Role of Basic Buffer Solution:
EDTA is a weak, non-dissociated polyprotic hexadentate acid ligand containing 2 nitrogen donor lone pairs and 4 carboxylate groups (−COO−).
An ammonium buffer solution (NH4Cl+NH4OH) maintains pH=10.0. This alkaline medium promotes the deprotonation of EDTA into charged ionic forms capable of binding metal cations securely.
Indicator Reaction and Color Transition:
Initially, EBT indicator (which is blue in its free form at pH=10) is added to hard water. It combines weakly with Ca2+ and Mg2+ ions to form an unstable wine-red complex: (Ca2+ or Mg2+)+EBT (Blue)→[Ca-EBT/Mg-EBT] (Unstable Wine-Red Complex)
During titration, EDTA is added from the burette. EDTA forms much stronger, highly stable, colorless chelate complexes with Ca2+ and Mg2+, replacing EBT: [Ca-EBT/Mg-EBT]+EDTA→[Ca-EDTA/Mg-EDTA] (Stable Colorless Complex)+EBT (Free Blue Indicator)
End Point: Sharp color change from Wine-Red to Clear Blue.
Detailed Analytical Procedure:
Standardization of EDTA Solution:
Dissolve 1.0g pure CaCO3 in dilute HCl and dilute to 1000mL with distilled water to prepare Standard Hard Water (M1=0.01M or 1mg/mL CaCO3).
Pipette out V1mL (50mL) of Standard Hard Water into a conical flask. Add 4−5mL buffer solution (pH=10) and 2 drops of EBT indicator.
Titrate with EDTA solution until the wine-red color turns clear blue (titre value V2mL).
Calculate EDTA Molarity (M2): M1⋅V1=M2⋅V2⟹M2=V2M1⋅V1
Determination of Total Hardness:
Pipette out V3mL (50mL) of unknown hard water sample into a conical flask.
Add 4−5mL buffer solution and 2 drops of EBT indicator. Titrate with standardized EDTA to clear blue (titre value V4mL).
Calculate Molarity (M3) and Total Hardness: M3=V3M2⋅V4 Total Hardness=M3×100(M.W. of CaCO3)×1000(mL/L)=M3×105ppm
Determination of Permanent Hardness:
Take 100mL of sample water in a beaker and boil it gently down to approximately half volume (50mL) to decompose temporary bicarbonates into insoluble carbonates.
Cool to room temperature, filter through filter paper to remove insoluble precipitates, and restore the volume back to original 100mL using distilled water.
Pipette out V3mL of this permanent hard water, add buffer and indicator, and titrate against EDTA to blue end point (titre value V4′mL).
Calculate Molarity (M4) and Permanent Hardness: M4=V3M2⋅V4′ Permanent Hardness=M4×105ppm
Determination of Temporary Hardness: Temporary Hardness=Total Hardness−Permanent Hardness
Overview of Water Softening Methods
Water softening techniques are broadly classified into External Treatment and Internal Treatment methods.

External Treatment: Treatment of raw water prior to entering boilers or supply lines. Includes:
Internal Treatment: Conditioning chemicals added directly inside boilers to prevent scale deposition. Includes:
Colloidal Conditioning
Carbonate Conditioning
Phosphate Conditioning
Calgon Conditioning
External Treatment: Lime-Soda Process
Principle: Calculated quantities of slaked lime [Ca(OH)2] and soda ash [Na2CO3] are added to hard water to precipitate soluble calcium and magnesium salts as insoluble CaCO3↓ and Mg(OH)2↓.
Chemical Reactions for Lime and Soda Requirements:
Removal of Temporary Calcium Hardness: Ca(HCO3)2+Ca(OH)2→2CaCO3↓+2H2O(Requires 1 Lime)
Removal of Temporary Magnesium Hardness: Mg(HCO3)2+2Ca(OH)2→Mg(OH)2↓+2CaCO3↓+2H2O(Requires 2 Lime)
Removal of Permanent Calcium Hardness: CaCl2+Na2CO3→CaCO3↓+2NaCl(Requires 1 Soda) CaSO4+Na2CO3→CaCO3↓+Na2SO4(Requires 1 Soda)
Removal of Permanent Magnesium Hardness: MgCl2+Ca(OH)2→Mg(OH)2↓+CaCl2(Requires 1 Lime) CaCl2+Na2CO3→CaCO3↓+2NaCl(Requires 1 Soda) MgSO4+Ca(OH)2→Mg(OH)2↓+CaSO4(Requires 1 Lime) CaSO4+Na2CO3→CaCO3↓+Na2SO4(Requires 1 Soda) (\text{Permanent Mg requires } 1 \text{ Lime} + 1 \text{ Soda}).
Removal of Free Dissolved Carbon Dioxide and Hydrogen Sulfide: CO2+Ca(OH)2→CaCO3↓+H2O(Requires 1 Lime) H2S+Ca(OH)2→CaS↓+2H2O(Requires 1 Lime)
Removal of Free Mineral Acids (HCl, H2SO4): 2HCl+Ca(OH)2→CaCl2+2H2O(Creates CaCl2) CaCl2+Na2CO3→CaCO3↓+2NaCl(Requires 1 Soda) (\text{Free mineral acids require } 1 \text{ Lime} + 1 \text{ Soda}).
Removal of Bicarbonate Ions (HCO3− e.g., NaHCO3): 2HCO3−+Ca(OH)2→CaCO3↓+H2O+CO32−(Requires L−S)
Removal of Iron and Aluminum Salts: FeSO4+Ca(OH)2→Fe(OH)2↓+CaSO4(Requires L+S) Al2(SO4)3+3Ca(OH)2→2Al(OH)3↓+3CaSO4(Requires 3(L+S))
Role of Coagulants in Cold Lime-Soda Process:
Precipitates formed at ambient temperature are finely divided colloidal particles that settle slowly.
Coagulants like sodium aluminate (NaAlO2) or alum [Al2(SO4)3] are added to form gelatinous hydroxides that entrap precipitates: NaAlO2+2H2O→NaOH+Al(OH)3↓ Al2(SO4)3+3Ca(HCO3)2→2Al(OH)3↓+3CaSO4+6CO2↑
Lime and Soda Requirement Formulae:
Lime Requirement (kg)=10074[Temp Ca2++2×Temp Mg2++Perm (Mg2++Fe2++Al3+)+CO2+H++HCO3−−NaAlO2]×106Volume in L×% Purity100
Soda Requirement (kg)=100106[Perm (Ca2++Mg2++Fe2++Al3+)+H+−HCO3−−NaAlO2]×106Volume in L×% Purity100 (Note: All constituent quantities inside brackets must be expressed in terms of CaCO3 equivalents).
Lime-Soda Process Equipment:
Continuous Cold Lime-Soda Softener: Operates at room temperature; requires coagulants and wood fiber filter media.

Continuous Hot Lime-Soda Process: Operates at 80∘C using superheated steam.

Advantages of Hot Process: Reaction rates increase dramatically, softening capacity is higher, coagulants are unnecessary because sludge precipitates settle rapidly, dissolved gases are expelled, viscosity decreases making filtration easy, and residual hardness is lower (15−30ppm).
Advantages of Lime-Soda Process: Highly economical, reduces total dissolved minerals, raises pH reducing corrosion, reduces pathogenic bacteria counts due to high alkalinity.
Disadvantages: Demands skilled supervision, creates large volumes of sludge causing disposal issues, residual hardness (15ppm) is too high for high-pressure boilers, leaves soluble sodium salts (Na2SO4) in water.
External Treatment: Zeolite (Permutit) Process
Principle: Zeolite is Hydrated Sodium Alumino Silicate (HSAS) with general chemical formula: Na2O⋅Al2O3⋅xSiO2⋅yH2O(x=2−10,y=2−6) It possesses a porous structure with cavities capable of reversibly exchanging sodium ions (Na+) for hardness-causing cations (Ca2+, Mg2+).

Softening Reactions: Na2Ze+CaCl2→CaZe+2NaCl Na2Ze+MgSO4→MgZe+Na2SO4 Na2Ze+Ca(HCO3)2→CaZe+2NaHCO3 Na2Ze+Mg(HCO3)2→MgZe+2NaHCO3
Regeneration Process:
When the bed becomes exhausted (CaZe and MgZe), it is regenerated by passing a 10% concentrated sodium chloride (NaCl) brine solution: CaZe/MgZe+2NaCl→Na2Ze+CaCl2/MgCl2
Washings containing soluble CaCl2 and MgCl2 are washed to drain.
Calculation Formula for Zeolite Regeneration: Hardness of Water (ppm)=58.550×Volume of hard water softened (L)Mass of NaCl consumed (g)×1000
Limitations: Turbid water clogs zeolite pores; manganese (Mn2+) and iron (Fe2+) form irreversible complexes; acidic water destroys zeolite structure.
Advantages: Produces soft water with low residual hardness (10−15ppm), compact equipment, clean operation without sludge formation.
Disadvantages: Leaves high sodium ion concentration in water; leaves bicarbonates (HCO3−) unaffected which decompose upon heating to generate CO2 (corrosion) and Na2CO3 (causing caustic embrittlement).
External Treatment: Ion-Exchange (Demineralization) Process

1. Cation Exchange Resins (RH+):
Contain acidic groups (−SO3H, −COOH, phenolic −OH). Examples: Amberlite IR-120, Dowex-50.
Softening Reaction: 2RH++Ca2+→R2Ca2++2H+ 2RH++Mg2+→R2Mg2++2H+
Effect on pH: Water treated only through a cation exchange column contains excess H+ ions, making its pH<7 (acidic).
Regeneration: Regenerated using dilute acid (HCl or H2SO4): R2Ca2++2HCl→2RH++CaCl2
2. Anion Exchange Resins (R+OH−):
Contain basic functional groups (quaternary ammonium −NR3+OH−, quaternary phosphonium, or tertiary sulfonium groups).
Softening Reaction: R+OH−+Cl−→R+Cl−+OH− 2R+OH−+SO42−→R22+SO42−+2OH−
Neutralization: Released H+ and OH− combine to form pure water: H++OH−→H2O
Regeneration: Regenerated using dilute alkali (NaOH or KOH): R22+SO42−+2NaOH→2R+OH−+Na2SO4
Advantages: Removes all ions completely producing zero hardness water; handles acidic or alkaline feed waters.
Disadvantages: High equipment and chemical costs; feed turbidity must be strictly under 10ppm.
Internal Treatment Methods for Boiler Feed Water
Internal conditioning converts scale-forming salts into soft soluble compounds or non-adherent sludges directly inside boilers:
Colloidal Conditioning:
Conditioning agents like glue, seaweed extract, agar-agar, or tannin are added to boiler water.
These organic colloids coat individual scale precipitates, keeping them dispersed as a non-sticky colloidal suspension easily removed via blow-down operations.
Phosphate Conditioning:
Sodium phosphate reagents react with calcium ions to yield soft, non-adherent calcium phosphate sludge: 3CaCl2+2Na3PO4→Ca3(PO4)2↓+6NaCl
Selection of Phosphate Reagent based on Boiler Water pH / Alkalinity:
Trisodium Phosphate (Na3PO4): Used for low alkalinity water (pH≈6).
Disodium Phosphate (Na2HPO4): Used for moderate/sufficient alkalinity water (pH≈7).
Monosodium Phosphate (NaH2PO4): Used for highly alkaline water (pH≈8).
Calgon Conditioning:
Involves adding Calgon—Sodium Hexametaphosphate [(NaPO<em>3)6 or Na6P6O</em>18].
Calgon ionizes: Na6P6O18→2Na++[Na4P6O18]2−
It forms a highly soluble complex anion with calcium sulfate, preventing scale precipitation: 2CaSO4+[Na4P6O18]2−→[Ca2P6O18]2−+2Na2SO4
Boiler Issues, De-oxygenation, Caustic Embrittlement, and Corrosion Types
Solved Numerical Problems and Step-by-Step Practice Solutions
Problem 1: Basic Hardness and Fractionation
A water sample contains Ca(HCO3)2=8.1mg/L, Mg(HCO3)2=29.2mg/L, CaCl2=11.1mg/L, and MgSO4=6.0mg/L. Calculate temporary, permanent, and total hardness in mg/L.
Solution:
Hardness due to Ca(HCO3)2=8.1×162100=5.0mg/L
Hardness due to Mg(HCO3)2=29.2×146100=20.0mg/L
Hardness due to CaCl2=11.1×111100=10.0mg/L
Hardness due to MgSO4=6.0×120100=5.0mg/L
Temporary Hardness=5.0+20.0=25.0mg/L
Permanent Hardness=10.0+5.0=15.0mg/L
Total Hardness=25.0+15.0=40.0mg/L
Problem 2: Unit Conversions for Calcium Sulfate Solution
A water sample contains 200mg of CaSO4 per liter. Calculate the hardness in mg/L, ppm, ∘Cl, and ∘Fr.
Solution:
Hardness in CaCO3 eq=200×136/2100/2=147.06mg/L=147.06ppm
Hardness in ∘Cl=147.06×0.07=10.29∘Cl
Hardness in ∘Fr=147.06×0.10=14.71∘Fr
Problem 3: Standard EDTA Molarity and Total Hardness Determination
50mL of standard hard water containing 1.0g pure CaCO3 per liter consumed 20mL of EDTA solution. 50mL of an unknown hard water sample consumed 25mL of the same EDTA solution. Calculate total hardness in ppm.
Solution:
Molarity of Standard Hard Water (M1) = 100g/mol×1L1.0g=0.01M
Molarity of EDTA (M2) = V2V1⋅M1=2050×0.01=0.025M
Molarity of Sample Water (M3) = V3V2⋅M2=5025×0.025=0.0125M
Total Hardness=0.0125×105ppm=1250ppm
Problem 4: EDTA Determination of Permanent and Temporary Hardness
0.28g of CaCO3 was dissolved in HCl and made up to 1.0L. 100mL of this solution required 28mL of EDTA solution. 100mL of hard water sample consumed 33mL of EDTA solution. 100mL of boiled, cooled, and filtered sample required 10mL EDTA solution. Calculate permanent and temporary hardness in ppm.
Solution:
Molarity of SHW (M1) = 1000.28=0.0028M
Molarity of EDTA (M2) = 28100×0.0028=0.01M
Molarity of Sample Water (M3) = 10033×0.01=0.0033M
Total Hardness=0.0033×105=330ppm
Molarity of Boiled Water (M4) = 10010×0.01=0.001M
Permanent Hardness=0.001×105=100ppm
Temporary Hardness=330−100=230ppm
Problem 5: Concentration Calculation from Hardness Threshold
How many grams of MgCl2 dissolved per liter of water will produce a hardness of 76ppm?
Solution:
Let mass of MgCl2 be xmg/L.
x×95100=76⟹x=10076×95=72.2mg/L=0.0722g/L
Problem 6: Comprehensive Multi-Ion Fractionation and Unit Conversion
A water sample contains Ca(HCO3)2=4mg/L, Mg(HCO3)2=6mg/L, CaSO4=8mg/L, and MgSO4=10mg/L. Calculate temporary, permanent, and total hardness in ppm, ∘Fr, and ∘Cl.
Solution:
Ca(HCO3)2 eq=4×162100=2.469mg/L
Mg(HCO3)2 eq=6×146100=4.110mg/L
CaSO4 eq=8×136100=5.882mg/L
MgSO4 eq=10×120100=8.333mg/L
Temporary Hardness=2.469+4.110=6.579mg/L=6.579ppm
In ∘Fr=6.579×0.1=0.6579∘Fr
In ∘Cl=6.579×0.07=0.4605∘Cl
Permanent Hardness=5.882+8.333=14.215mg/L=14.215ppm
In ∘Fr=14.215×0.1=1.4215∘Fr
In ∘Cl=14.215×0.07=0.9950∘Cl
Total Hardness=6.579+14.215=20.794mg/L=20.794ppm
In ∘Fr=20.794×0.1=2.0794∘Fr
In ∘Cl=20.794×0.07=1.4555∘Cl
Problem 7: Lime-Soda Requirement with Pure Reagents
Calculate the quantities of lime and soda required for softening 18,000L of water containing: Temporary Ca hardness = 25ppm, Permanent Ca hardness = 20ppm, and Permanent Mg hardness = 15ppm.
Solution:
Lime Requirement=10074[Temp Ca+Perm Mg]×Volume Lime Requirement=10074[25+15]×18,000=532,800mg=532.8g
Soda Requirement=100106[Perm Ca+Perm Mg]×Volume Soda Requirement=100106[20+15]×18,000=667,800mg=667.8g
Problem 8: Lime-Soda Requirement with Ions and Impurity Factors
A water sample contains: Ca2+=95ppm, Mg2+=36ppm, CO2=66ppm, HCO3−=244ppm, and H+=2ppm. Calculate quantities of lime (74% purity) and soda (92% purity) required to soften 125,000L of water.
Solution:
Convert concentrations to CaCO3 equivalents:
Ca2+=95×40100=237.5ppm(S)
Mg2+=36×24100=150.0ppm(L+S)
CO2=66×44100=150.0ppm(L)
HCO3−=244×122100=200.0ppm(L−S)
H+=2×2100=100.0ppm(L+S)
Lime Factor=[Mg2++CO2+HCO3−+H+]=[150+150+200+100]=600.0ppm Lime Required=10074[600]×125,000×74100×10−6kg=75.0kg (Or if purity is 74%: Lime=56.25kg depending on formula variant used).
Soda Factor=[Ca2++Mg2++H+−HCO3−]=[237.5+150+100−200]=287.5ppm Soda Required=100106[287.5]×125,000×92100×10−6kg=41.40kg
Problem 9: Zeolite Softener Hardness Calculation from Effluent
1000L of hard water passed through a zeolite softener yielded effluent water containing 0.25g/L of NaCl. Calculate the hardness of water.
Solution:
58.5g NaCl≡50g CaCO3
0.25g NaCl=58.550×0.25=0.21367g CaCO3/L
Hardness=0.21367g/L=213.67mg/L=213.67ppm
Problem 10: Zeolite Regeneration Capacity
A zeolite softener completely softened 5000L of hard water. The bed required 55L of NaCl solution containing 100g/L NaCl for complete regeneration. Calculate hardness in ppm.
Solution:
Total mass of NaCl consumed=55L×100g/L=5500g
117g NaCl≡100g CaCO3
CaCO3 equivalent=5500×117100=4700.85g CaCO3
Hardness per liter=5000L4700.85g=0.94017g/L=940.17ppm
(Note: Taking 2×58.5≈107g gives 5140.186g⟹1028ppm).