Electric Current, Circuit Analysis, and Power

Electric Current and Charge

  • Electric Current Definition: The rate at which electric charge flows past a point in a conductor.

    • Formula: I=ΔQΔtI = \frac{\Delta Q}{\Delta t}
    • Base unit: ampere (AA), where 1 A=1 C/s1\,A = 1\,C/s.
    • Metric conversions: 1 mA=10−3 A1\,mA = 10^{-3}\,A, 1 μA=10−6 A1\,\mu A = 10^{-6}\,A, 1 kA=103 A1\,kA = 10^3\,A.
  • Charge Quantization:

    • Elementary charge of a single electron: e=1.60×10−19 Ce = 1.60 \times 10^{-19}\,C
    • Total charge formula: Q=neQ = ne, where nn is the number of electrons.
  • Direction Conventions:

    • Conventional Current: Flows from the positive (+$) terminal to the negative (-) terminal through the external circuit; standard for all circuit diagrams and equations.\n * **Electron Flow**: Physical drift of negative charge carriers from the negative (-)terminaltothepositive() terminal to the positive (+$) terminal.
  • Circuit Continuity:

    • A continuous current requires a source of potential difference, a conducting path, and an unbroken closed loop.
    • Opening a switch breaks the loop and reduces current to zero everywhere in that loop instantaneously.
  • Meter Placement:

    • Ammeter: Measures current; connected in series; ideal resistance is near 0 Ω0\,\Omega.
    • Voltmeter: Measures potential difference; connected in parallel across components; ideal resistance is extremely high.

Electrical Potential Difference

  • Definition: The energy transferred per unit charge between two points in a circuit.
    • Formula: ΔV=ΔEQ\Delta V = \frac{\Delta E}{Q}
    • Base unit: volt (VV), where 1 V=1 J/C1\,V = 1\,J/C.

Electrical Resistance and Resistivity

  • Definition: A measure of how strongly a component opposes electric current flow, measured in ohms (Ω\Omega).

  • Factors Affecting Conductor Resistance:

    • Length (LL): Directly proportional (L↑→R↑L \uparrow \rightarrow R \uparrow; R∝LR \propto L) due to more collisions.
    • Cross-Sectional Area (AA): Inversely proportional (A↑→R↓A \uparrow \rightarrow R \downarrow; R∝1AR \propto \frac{1}{A}) due to a wider path.
    • Material Resistivity (ρ\rho): Intrinsic property of the material, measured in Ω⋅m\Omega\cdot m.
    • Temperature (TT): In metals, higher temperature increases ion vibrations and collision rates (T↑→R↑T \uparrow \rightarrow R \uparrow).
  • Resistance Equation:

    • R=ρLAR = \frac{\rho L}{A}
    • For cylindrical wires: A=πr2A = \pi r^2, with linear dimensions converted to metres (1 mm2=10−6 m21\,mm^2 = 10^{-6}\,m^2).

Ohm's Law and Conductor Behavior

  • Ohm's Law: For a conductor at constant physical conditions (e.g., constant temperature), potential difference is directly proportional to current.

    • Expressions: ΔV=IR\Delta V = IR, I=ΔVRI = \frac{\Delta V}{R}, and R=ΔVIR = \frac{\Delta V}{I}
  • Conductor Classification:

    • Ohmic Conductors: Yield a linear V–IV\text{--}I graph passing through the origin; the slope equals the resistance (slope=R\text{slope} = R).
    • Non-Ohmic Conductors: Yield a curved V–IV\text{--}I graph because resistance varies with changing operating conditions such as temperature (e.g., filament lamps).

Resistors in Series and Parallel

  • Series Circuits:

    • Current is identical through every component: It=I1=I2=I3=…I_t = I_1 = I_2 = I_3 = \dots
    • Potential difference divides: ΔVt=ΔV1+ΔV2+ΔV3+…\Delta V_t = \Delta V_1 + \Delta V_2 + \Delta V_3 + \dots
    • Total equivalent resistance is the direct sum: Rt=R1+R2+R3+…R_t = R_1 + R_2 + R_3 + \dots
    • A break anywhere opens the circuit and drops loop current to zero.
  • Parallel Circuits:

    • Potential difference is identical across every branch: ΔVt=ΔV1=ΔV2=ΔV3=…\Delta V_t = \Delta V_1 = \Delta V_2 = \Delta V_3 = \dots
    • Total current splits among branches: It=I1+I2+I3+…I_t = I_1 + I_2 + I_3 + \dots
    • Reciprocal resistance rule: 1Rt=1R1+1R2+1R3+…\frac{1}{R_t} = \frac{1}{R_1} + \frac{1}{R_2} + \frac{1}{R_3} + \dots
    • The equivalent resistance RtR_t is always strictly less than the smallest individual branch resistance.
    • A failure in one branch leaves the remaining parallel branches operating independently.
  • Combined Circuits Analysis:

    • Iteratively reduce identifiable series and parallel blocks into single equivalent resistances until one total resistance (RtR_t) remains.
    • Apply Ohm's Law to calculate total current, then back-substitute to find branch currents and voltage drops.

Kirchhoff's Laws

  • Kirchhoff's Current Law (KCL):

    • Physical principle: Conservation of electric charge.
    • Statement: At any circuit junction or node, the total current flowing in equals the total current flowing out:
    • ∑Iin=∑Iout\sum I_{\text{in}} = \sum I_{\text{out}}
  • Kirchhoff's Voltage Law (KVL):

    • Physical principle: Conservation of energy.
    • Statement: The algebraic sum of all potential differences (EMFs and IR drops) around any closed loop is zero:
    • ∑ΔV=0\sum \Delta V = 0
  • Loop Walking Sign Conventions:

    • Traversing a battery from −- to ++: add +ε+\varepsilon (gain).
    • Traversing a battery from ++ to −-: add −ε-\varepsilon (drop).
    • Traversing a resistor in the assumed current direction: add −IR-IR (drop).
    • Traversing a resistor against the assumed current direction: add +IR+IR (gain).
  • Negative Current Interpretation:

    • A negative solved current indicates that the true current flows opposite to the assumed direction arrow; the calculated magnitude remains correct.

Electric Power and Energy Costs

  • Electric Power:

    • The rate of using or converting electrical energy, measured in watts (WW), where 1 W=1 J/s1\,W = 1\,J/s.
    • Fundamental definition: P=EtP = \frac{E}{t}
    • Circuit power formulas: P=IVP = IV, P=I2RP = I^2 R, and P=V2RP = \frac{V^2}{R}
  • Electrical Energy Billing:

    • Commercial energy unit: kilowatt-hour (kWhkWh).
    • Unit conversion: 1 kWh=1000 W×3600 s=3.6×106 J1\,kWh = 1000\,W \times 3600\,s = 3.6 \times 10^6\,J
    • Utility cost formula: Cost=Price per kWh×Energy used in kWh\text{Cost} = \text{Price per } kWh \times \text{Energy used in } kWh