Medical Imaging Equipment and Modalities Study Guide

Administrative Notes and Logistics

  • Equipment Inspection: The instructor is expecting a phone call from the state regarding an inspection of equipment. Due to the importance of this call, the phone ringer will remain on, and a break will be called if the instructor must step away.
  • Course Schedule: This is the final Tuesday lecture. A test is scheduled for the following Tuesday.
  • Trajexis Registration: Students will be registering for Trajexis, which is the timekeeping application used for clinical rotations.
  • Clinical Transition: Students are nearing the beginning of their clinical rotations, transitioning from lab-based learning to real-world medical environments.

Fundamental Key Terms in Medical Imaging

  • Control Panel and Detector: The primary interface for setting exposure factors and the device that captures the exit radiation.
  • Automatic Exposure Control (AEC): A system used to consistently control the amount of radiation reaching the image receptor by terminating the exposure once a predetermined intensity is reached.
  • Anode and Cathode: The two primary electrodes within the X-ray tube.
  • Bucky Grid: The grid that fires or oscillates inside the Bucky assembly to reduce scatter radiation reaching the receptor.
  • CR Cassette: A Computed Radiography cassette using a photostimulable phosphor plate.
  • DR Panel: A Digital Radiography panel, specifically a flat panel detector.
  • Flat Panel Detector: A type of digital imaging sensor used in DR to convert X-rays into electrical signals.
  • Post-processing: Manipulations performed by the computer software on the image data after the exposure has been taken.
  • Soft Copy: The digital version of a radiograph that has not yet been officially sent or printed.
  • Tether: A physical cable that attaches the detector panel to the system (e.g., in localized rooms or on portables).
  • Auto-tracking: A feature where the X-ray tube automatically moves in sync with the Bucky (wall or table) to maintain alignment.
  • Tube Movements:
    • Longitudinal: Movement along the long axis of the table.
    • Transverse: Movement across the width of the table.
    • Vertical: Up and down movement of the tube.
    • Tube Angulation: Pivoting the tube from 9090 to 00 degrees or other specific angles.
  • Collimator: A device attached to the X-ray tube housing that restricts the size and shape of the X-ray beam.
  • Positive Beam Limitation (PBL): An automatic collimation system that adjusts the X-ray field to the size of the image receptor.
  • X-ray Tube Head and Overhead Tube Crane: The assembly containing the tube and the rail system (crane) that allows it to move throughout the room.

Diagnostic Yield and Efficacy

  • Physician Considerations: Physicians consider various factors when ordering exams, but accuracy is the most vital to determine the patient's pathology.
  • Consequences of Inaccuracy:
    • Patient reshoots, leading to excessive radiation exposure.
    • Delays in patient care.
    • Missed diagnoses.
  • Clinical Anecdote (The Importance of Accuracy): The instructor shared a case involving a portable X-ray of a patient in their early 20s20\text{s}. The image included the lung apices but they were at the very edge of the film. To avoid re-exposure, the instructor initially accepted the image. However, the radiologist noted a possible pneumothorax that was obscured by the edge of the plate. The instructor had to retake the image, confirming the pneumothorax. This served as a warning that a technologist's decision to accept a sub-optimal image can lead to undiagnosed life-threatening conditions.
  • Artifacts: Jewelry, clothing, tubes, and lines reduce the radiologist's ability to diagnose accurately. These are compared to "paint on a back window," which obstructs the view and reduces safety.
  • Diagnostic Yield: The amount of useful information available on an image. It determines the information available for a radiologist to make a diagnosis.
  • Professionalism: True professionals are not perfect but respond to critiques and mistakes effectively. A professional accepts feedback from radiologists, performs necessary re-takes, and takes a moment to learn from the error to prevent its recurrence.

Principles of Equipment Operation and Success

  • Student Success: Success in clinicals is tied to the ability to handle various types of X-ray equipment.
  • Equipment Variability: Clinical sites like Tri-City may use much older equipment (some over 1212 years old), while new equipment is extremely expensive; a single room build can cost up to $1,000,000\$1,000,000.
  • Clinical Strategy:
    • "Be a sponge" and ask questions.
    • Utilize downtime for simulation and practice when no patients are present.
    • Familiarize yourself with different brands and manufacturers as buttons and locks will vary by machine.

Anatomy of the X-ray Tube and Beam Production

  • The Cathode: Contains the filament which burns off (thermionic emission) the electrons.
  • The Anode: Contains the focal point/target. When the electron beam hits the anode, the energy conversion occurs.
  • Energy Conversion:
    • 99%99\% of electrons are converted to heat.
    • 1%1\% are converted to X-rays.
  • Photon Discharge: Photons are discharged in all directions. The lead-lined tube head and collimator box permit only those traveling straight down to exit high-intensity, while others are absorbed/disintegrated.
  • Beam Control: By adjusting current (massmass) and voltage (kVpkVp), technologists direct the beam onto the patient.

Control Panel Components and Lab Techniques

  • Main Power Switch: Usually located in the upper left of the panel.
  • Lab Protocol Flash Study:
    • Chest X-ray: 115115 kVp at 3.23.2 mAs.
    • Abdomen X-ray: 8080 kVp at 1010-1212 mAs.
    • Hand X-ray: 5555 kVp at 1.61.6 mAs.
  • Focal Spot Selection: A small focal spot (indicated by a lit-up button on the panel) is used for small items like the hand to ensure higher detail. For most other exams like chest or abdomen, a larger focal spot is used.
  • Technique Calculation: The mass or time (milliseconds) should not be manually adjusted if it has already been calculated/set automatically for the exam.
  • AEC Usage: For current lab purposes, Automatic Exposure Control (AEC) should be set to off.
  • Console Variations:
    • Fuji Consoles: Commonly used by Sharp facilities.
    • Konica Consoles: Used in other clinical settings.
    • Touchscreen Monitors: Many consoles allow for touchscreen interaction, which is often faster than using a mouse.

Radiographic Table and Tube Support Systems

  • Tube Head Flexibility: Can angle up to 135135 degrees and turn approximately 340340 degrees, which is helpful for trauma or patients with limited mobility.
  • Weight Capacity: All tables have a weight limit (e.g., 250 kg250\,kg). If a patient is near the limit, avoid raising the table, as it puts unnecessary strain on the mechanics and may cause the table to break.
  • Bucky Grids: Some feature an oscillating or "moving" grid that makes a distinct "clunk-clunk" sound during exposure.

Fluoroscopy: Real-Time Dynamic Imaging

  • Definition: Dynamic, real-time imaging of internal structures.
  • Equipment Types:
    • Image Intensifier (II): Older technology with a large, bulky top assembly.
    • Flat Panel Detector: Newer technology similar to DR systems.
  • Tube Placement: In most rooms, the tube is underneath the table, and the intensifier/receptor is on top. This affects scatter radiation patterns; under-table tubes allow for lead aprons on the bed to block scatter from the technologist.
  • Common Procedures:
    • Barium Enemas (BE): Imaging of the large intestine.
    • Upper Gastrointestinal Study (UGI): Imaging the esophagus, stomach, and small intestine.
    • Small Bowel Follow-Through: Following barium through the small intestine.
    • Arthrograms: Visualizing joints (often for arthritis or inflammation) by injecting contrast to check for capsular integrity.
    • Myelograms: Injecting contrast into the spinal column to examine cerebral spinal fluid and check for leaks.
    • Lumbar Puncture: The clinical term for what is colloquially known as a "spinal tap."
  • Dose Reduction Features:
    • Pulse Mode: Creates X-rays in pulses rather than a continuous beam (accompanied by a beep). This significantly reduces patient and staff dose while maintaining a viewable image.
    • Last Image Hold (LIH): Displays the final frame of the fluoroscopy on the screen after the pedal is released, allowing clinicians to study the anatomy without continuous exposure.
  • Imaging Modes:
    • Spot Images: Single frames taken at one frame per second.
    • Series Images: Multiple images taken in rapid succession (e.g., 1515 images per second) to capture motion like swallowing.

Advanced Imaging Modalities and Specialized Systems

  • Mobile Units: Includes portables and C-arms (used in the OR). Before a case, technologists should orient themselves with the specific locks and buttons of the C-arm to avoid delays under pressure from surgeons.
  • Tomosynthesis (Tomo):
    • Used extensively in Mammography.
    • Creates 3D-like slices by arcing the tube over the anatomy.
    • Provides much higher detail than conventional digital mammography for catching breast cancer early.
  • Computed Tomography (CT):
    • Stationary units are most common.
    • Portable CT units exist but are heavy and difficult to move, mainly used in large OR suites.
    • Experimental Logistics: Discussion of putting CT on ambulances for stroke/heart attack response involves issues including radiation shielding (lead lining makes vehicles heavy) and the need for a specialized Rad Tech in the vehicle.
  • Dual-Emission X-ray Absorptiometry (DEXA):
    • Used for bone density; creates "z numbers."
    • Note: DEXA images are non-diagnostic; a separate X-ray is required if a physician needs to see physical internal detail or bone structure.
  • History of Mammography:
    • 1960s: Used industrial film (extremely high dose).
    • 1970s: Xerox mammography (no radiation but lacked detail and missed cancer).
    • 1980s: Film screens (reduced dose).
    • Digital/CR: Shift away from physical processing.
    • Modern: DR and Tomosynthesis are current standards.
  • Other Specialized Fields (Require Additional Schooling):
    • Sonography: Uses sound waves; no radiation.
    • MRI: Uses magnetic resonance; different physics than X-ray.
    • Nuclear Medicine: Uses radionuclides injected/ingested; the patient becomes the radiation source captured by a camera.
    • Radiation Therapy: High-dose radiation used for cancer treatment.