Study Notes on High Voltage and Current Measurement Techniques

Measurement of High Voltages and Currents

  • Importance of High Voltage and Current Measurement
      - Essential in industrial testing and research laboratories.
      - Accuracy in measurement ensures safety for personnel and equipment.
      - Protection against overvoltages and induced voltages due to stray coupling is necessary.
      - Device location and layout are crucial for effective measurement.

Classification of High Voltage Measurement Devices

  • High voltage measuring devices differ significantly from low voltage devices due to:
      - Calibration needs for high voltage devices (device ranges must not be extrapolated linearly).
      - Need to minimize electromagnetic interference in impulse voltage and current measurements.

Types of High Voltage Measurement Devices

  • Table 7.1 - High Voltage Measurement Techniques
      - (a) d.c. voltages
        - (i) Series resistance microammeter.
        - (ii) Resistance potential divider.
        - (iii) Generating voltmeters.
        - (iv) Sphere and other spark gaps.
      - (b) a.c. voltages (power frequency)
        - (i) Series impedance ammeters.
        - (ii) Potential dividers (resistance or capacitance type).
        - (iii) Potential transformers (electromagnetic or capacitance voltage transformer).
        - (iv) Electrostatic voltmeters.
        - (v) Sphere gaps.
      - (c) High frequency a.c., impulse voltages, and rapidly changing voltages
        - (i) Potential dividers with a cathode ray oscillograph.
        - (ii) Peak voltmeters.
        - (iii) Sphere gaps.

Measurement of High Direct Current (d.c.) Voltages

Techniques Used

  • General method involves extending meter range with a large series resistance.

  • Typical net current through the meter is limited to one to ten microamperes for full-scale deflection.

Challenges with High d.c. Voltages
  • At very high voltages (1000 kV or more), challenges arise due to:
      - Large power dissipation.
      - Leakage currents.
      - Limitations on voltage stress per unit length.
      - Resistance changes due to temperature variations.

Solution Techniques
  • Resistance Potential Divider with Electrostatic Voltmeter
      - Provides better performance for high precision needs, but still suffers drawbacks of power dissipation and current drain.
      - Spark gaps, such as sphere gaps, can be used for peak voltage measurement, affected by atmospheric conditions.

Measurement Technique Details

7.1.1 High Ohmic Series Resistance with Microammeter

  • High voltage measured by connecting a high resistance (hundreds of megaohms) in series with a microammeter.

  • Voltage calculated via V=IRV = IR, where:
      - V is the voltage of the source.
      - I is the current through the calibrated resistance R.

  • Protective device used across meter (e.g., paper gap, neon glow tube) ensures protection against high voltages.

Protective Resistance Setup
  • Value of series resistance R designed to allow a current of 1-10 microamperes for full-scale deflection.

  • Constructed from multiple wire wound resistors in series to avoid ground flashovers.

  • Corona-free terminations prevent discharge issues, using materials with low temperature coefficients.

Limitations of Series Resistance Design
  • Significant challenges include:
      - Power dissipation and source loading.
      - Temperature effects and long-term stability.
      - Voltage dependence of resistive elements.
      - Sensitivity to mechanical stresses.

7.1.2 Resistance Potential Dividers for d.c. Voltages

  • High accuracy with designs eliminating temperature and voltage influences.

  • Voltage measured using the formula:
      V=rac(Ri+R2)R2imesV2V = rac{(R_i + R_2)}{R_2} imes V_2
      where V2 is the voltage across the lower arm R2.

Protecting Against Transient Voltages
  • Voltage controlling capacitors connected across elements mitigate transient issues that may arise during voltage fluctuations.

Additional Measurement Techniques

7.1.3 Generating Voltmeters

  • Operate under principles that isolate source loading, especially with generators.

Principle of Operation
  • Charge stored in capacitor: q=CVq = CV, where C is capacitance, V is voltage.

  • Varying capacitance results in current: I=racdqdtI = rac{dq}{dt}.

  • The current for varying capacitance described as sinusoidal yields RMS value:
      Irms=racCmimesracdVdtextangularfrequencyI_{rms} = rac{C_m imes rac{dV}{dt}}{ ext{angular frequency}}.

Practical Implementations
  • Design of generating voltmeters incorporates rotating mechanisms driven by synchronous motors; can measure a.c. voltages under specific speed conditions.

Measurement of High a.c. and Impulse Voltages

Techniques Used

  • Commonly utilize potential dividers, transformers, and electrostatic voltmeters, with designs tailored for insulation and source loading.

Key Instruments in High a.c. Measurement

  • Peak Voltmeters and Sphere Gaps
      - Specifically utilized for capturing peak values and reference during calibration.

Series Impedance Voltmeters
  • Employ resistive or reactive impedance for power frequency a.c. measurements, with capacitance preferred to minimize losses.

Series Capacitance Voltmeters
  • Designed to substitute for resistors to negate thermal variations and boost accuracy in high a.c. measurements.

Capacitance Potential Dividers
  • High accuracy employed in measurement while addressing harmonics through additional capacitors for linearization.

Capacitive Voltage Transformers (CVTs)
  • Used in power systems; configured to measure various voltages while providing isolation between high and low voltage terminals.

Potentials and Capacitive Devices

  • Potential Transformers (PT)
      - Old devices offering simplified construction, but can experience ratio and phase angle errors, suffering from harmonic and transient limitations.

Electrostatic Voltmeters

  • Operate within electrostatic fields, leveraging the attractive forces between electrodes, useful for accurate measurement of high voltage parameters.

Spark Gaps for Measurement of High Voltages

Construction and Functionality

  • Uniform field spark gaps provide reliable measurements of peak voltage based upon known sparkover voltage parameters.

Sphere Gaps

  • Spheres are generally made from conductive materials (copper, aluminum) with engineered dimensions.

  • Peak values recorded are dependent on spacing and surrounding conditions.

Operational Considerations
  • Precise arrangement of spheres can affect results; configurations can either be vertical or horizontal to enhance measurement reliability.

Sparkover Voltage Calibration
  • Measurements involve finding average sparkover values across multiple trials, recommending preliminary measurements before critical ones.

Capacitance and Environment Effects

  • The sphere gap measurements involve accounting for nearby earthed objects, temperature, humidity, and the effects of irradiation on voltage readings.

Worked Examples

Example 7.1: Generating Voltmeter Design

  • Capacitance calculated based on designed range from 20 kV to 200 kV while ensuring operational stability under specified current readings.

Conclusion of Calculations
  • Generated capacitance for the voltmeter deduced to meet operational parameters effectively, suggesting an ideal capacitor configuration.

Example 7.2: Peak Reading Voltmeter Configuration

  • Design criteria established based on specific voltage requirements, employing potential divider ratios to ascertain meter specifics for usability up to specified peak voltages.