HVAC Construction Math for Construction Management and Jobsite Maintenance (Outcome 6.1)

6.1.1 Calculate surface area and volume for three-dimensional objects (to required precision)

In HVAC work, you constantly move between “how big is this object?” and “how much material does it take to cover or fill it?” Those are two different ideas:

  • Volume is the amount of space inside a 3D object. You use it for things like concrete pads, equipment housekeeping curbs, duct internal volume (sometimes for purge or pressurization problems), and tanks.
  • Surface area is how much outside area an object has. You use it for sheet metal, insulation wrap, vapor barrier, paint, roof flashing, and coating.
Why precision matters (and what “to a specified level” means)

Construction math rarely needs infinite decimals. Plans and specs typically demand a level of precision—for example:

  • nearest 116 in\frac{1}{16}\,\text{in} for layout cuts
  • nearest 0.1 ft0.1\,\text{ft} for rough site dimensions
  • nearest 1 cm1\,\text{cm} or 1 mm1\,\text{mm} on metric projects
  • nearest 0.01 m30.01\,\text{m}^3 for concrete ordering

The key is to carry extra digits during calculations and round only at the end to the required precision. A common jobsite error is rounding too early and compounding the rounding error across multiple steps.

Core shapes you’ll see in HVAC construction

Most HVAC components can be approximated as one of these solids.

Rectangular prism (box)

Used for equipment pads, duct sections (rectangular duct), curbs, and chases.

If LL is length, WW is width, and HH is height:

V=L W HV = L\,W\,H

SA=2(LW+LH+WH)SA = 2(LW + LH + WH)

What goes wrong: mixing inside vs outside dimensions. Insulation and sheet metal often use outside dimensions; airflow calculations use inside dimensions.

Worked example (volume, with rounding at the end):
A concrete equipment pad is 6.0 ft6.0\,\text{ft} by 4.0 ft4.0\,\text{ft} by 4.0 in4.0\,\text{in} thick. Find volume in cubic feet to the nearest 0.01 ft30.01\,\text{ft}^3.

Convert thickness to feet:

4.0 in=4.012 ft=0.3333 ft4.0\,\text{in} = \frac{4.0}{12}\,\text{ft} = 0.3333\,\text{ft}

Compute volume:

V=6.0×4.0×0.3333=7.9992 ft3V = 6.0\times 4.0\times 0.3333 = 7.9992\,\text{ft}^3

Round at the end:

V≈8.00 ft3V \approx 8.00\,\text{ft}^3

Cylinder

Used for pipe, round duct, sleeves, and some tanks.

If rr is radius and hh is height/length:

V=πr2hV = \pi r^2 h

Total surface area (including both circular ends):

SA=2πr2+2πrhSA = 2\pi r^2 + 2\pi r h

Lateral surface area (wrap only, no ends):

SAlateral=2πrhSA_{\text{lateral}} = 2\pi r h

Why this matters in HVAC: Insulation for a pipe typically uses the lateral area of the insulation jacket (you’re wrapping the length), while an end cap would require the end area.

Worked example (insulation wrap area):
You need insulation jacketing for 40 ft40\,\text{ft} of round duct with diameter 18 in18\,\text{in}. Approximate lateral area in square feet to the nearest 1 ft21\,\text{ft}^2.

Radius:

r=18 in2=9 in=0.75 ftr = \frac{18\,\text{in}}{2} = 9\,\text{in} = 0.75\,\text{ft}

Lateral area:

SA=2πrh=2π(0.75)(40)=60π ft2SA = 2\pi r h = 2\pi(0.75)(40) = 60\pi\,\text{ft}^2

Numeric approximation:

SA≈188.5 ft2SA \approx 188.5\,\text{ft}^2

Rounded:

SA≈189 ft2SA \approx 189\,\text{ft}^2

Triangular prism

Used when you have wedge-shaped curbs, duct transitions approximations, and sloped features.

If the triangular base has area A△A_{\triangle} and prism length is LL:

V=A△LV = A_{\triangle} L

Triangle base area (common case with base bb and height hh):

A△=12bhA_{\triangle} = \frac{1}{2} b h

Common mistake: confusing the triangle’s “height” (perpendicular to base) with a sloped side length.

Exam Focus
  • Typical question patterns
    • “Find the surface area/volume of a duct, pipe, pad, or tank, then round to a specified precision.”
    • “Compute material quantity (insulation/metal/concrete) from dimensions given in mixed units (in/ft).”
    • “Decide whether to include ends (total area) or not (lateral area).”
  • Common mistakes
    • Rounding intermediate steps too early instead of rounding once at the end.
    • Using diameter where radius is required in cylinder formulas.
    • Mixing inside vs outside dimensions (especially when insulation thickness is involved).

6.1.2 Apply measurement scales to layout length, width, and angle measurements

A measurement scale is a controlled ratio between the size on a drawing and the real size in the field. In construction management, scale skills let you translate between plan dimensions and real layout—critical for placing equipment, sleeves, duct drops, and roof penetrations correctly.

Understanding scale as a ratio

A scale can be thought of as:

Scale factor=drawing lengthactual length\text{Scale factor} = \frac{\text{drawing length}}{\text{actual length}}

On architectural drawings in the U.S., you often see formats like “14 in=1 ft\frac{1}{4}\,\text{in} = 1\,\text{ft}”. That means every 0.25 in0.25\,\text{in} on paper represents 1 ft1\,\text{ft} in real life.

Why it matters: If you misread scale, every downstream measurement is wrong—equipment ends up mislocated, clearances fail, and rework costs climb.

Architectural vs engineering scales (practical distinction)
  • Architectural scale commonly expresses feet and inches (typical building plans).
  • Engineering scale commonly expresses decimal feet (site/civil plans).

You don’t need the brand of scale memorized—you need to recognize the units and the format being used.

How to apply a scale to a plan dimension

There are two safe approaches:

1) Use printed dimensions when available. If a plan explicitly labels 12 ft−6 in12\,\text{ft} - 6\,\text{in}, trust the label rather than measuring with a ruler (prints can be resized).

2) If you must measure, convert using the scale ratio.

Worked example (scale conversion):
A duct riser is located 1.75 in1.75\,\text{in} from a wall on a drawing that uses 14 in=1 ft\frac{1}{4}\,\text{in} = 1\,\text{ft}. Find the actual distance.

At this scale, 0.25 in0.25\,\text{in} represents 1 ft1\,\text{ft}, so:

actual feet=1.750.25=7 ft\text{actual feet} = \frac{1.75}{0.25} = 7\,\text{ft}

So the actual offset is:

7 ft7\,\text{ft}

Applying scale to angles and layout

Angles on construction drawings are usually shown as:

  • a labeled angle value (preferred)
  • a geometric relationship (perpendicular, parallel)
  • sometimes a measured angle from a detail

If an angle is not labeled, you typically infer it from geometry (for example, a rectangle corner implies 90∘90^\circ) or use a protractor on the drawing (less reliable than labeled dimensions).

In the field, angle layout is often done using:

  • speed square for common angles
  • framing square for perpendicular layout
  • 3-4-5 triangle method for right angles

The “3-4-5” method is a scale-free way to build a right angle because it relies on the Pythagorean relationship.

Exam Focus
  • Typical question patterns
    • “Given a drawing scale and a measured plan distance, find the real distance.”
    • “Given a real-world dimension, compute what it should measure on the plan at a given scale.”
    • “Use scale to position equipment or penetrations relative to gridlines/walls.”
  • Common mistakes
    • Measuring a printed drawing that has been resized instead of using written dimensions.
    • Confusing architectural and engineering scales (feet-inches vs decimal feet).
    • Treating angle layout as a scale problem when it’s usually a geometry problem.

6.1.3 Apply algebraic procedures and geometric concepts to reading construction documents

Construction documents aren’t just pictures—they encode constraints. Algebra helps you solve for missing values (unknown lengths, elevations, quantities), and geometry helps you interpret shapes, alignments, and spatial relationships.

Key document concepts that drive the math
  • Dimension strings: a chain of segments that must add to an overall length.
  • Centerlines: indicate symmetrical placement (common for duct mains and equipment).
  • Elevations: vertical position relative to a datum (e.g., finished floor).
  • Slopes/grades: rise over run (common for drainage and roof pitch, and sometimes for condensate piping).

A recurring skill is turning a sentence like “centered in bay” or “maintain clearance” into a measurable relationship.

Algebra you actually use on plans
Solving from totals (dimension-string logic)

If a wall is 30 ft30\,\text{ft} long and you have two known offsets and one unknown location, you’re doing algebra even if it feels like “just subtracting.”

If total length is TT and known segments sum to SS, then:

x=T−Sx = T - S

Worked example (unknown offset):
A mechanical room wall length is 24 ft24\,\text{ft}. A unit must be 3 ft3\,\text{ft} from the left corner and 5 ft5\,\text{ft} from the right corner to allow piping access. What is the maximum allowable equipment length along that wall?

Remaining space:

x=24−3−5=16 ftx = 24 - 3 - 5 = 16\,\text{ft}

So maximum equipment length is:

16 ft16\,\text{ft}

Rearranging formulas (solve for the variable you need)

You’ll often start with a known relationship (area, slope, volume, flow) and need to isolate the unknown.

Example: If you know volume VV of a rectangular pad and want thickness HH:

V=LWHV = LWH

Solve for HH:

H=VLWH = \frac{V}{LW}

Geometry concepts that show up in HVAC layout
Perpendiculars and parallel runs

Duct runs are frequently shown parallel to gridlines or walls. Recognizing parallel/perpendicular relationships prevents “angle drift” in layout.

Pythagorean theorem for offsets and diagonals

When you route ductwork or piping around an obstacle, you often create a right-triangle offset.

For a right triangle with legs aa and bb and hypotenuse cc:

c2=a2+b2c^2 = a^2 + b^2

Worked example (diagonal offset length):
A pipe must shift 18 in18\,\text{in} horizontally and 24 in24\,\text{in} vertically. What is the diagonal travel length of the offset (ignoring fitting takeoff) to the nearest 18 in\frac{1}{8}\,\text{in}?

Compute hypotenuse:

c=182+242=324+576=900=30 inc = \sqrt{18^2 + 24^2} = \sqrt{324 + 576} = \sqrt{900} = 30\,\text{in}

Nearest 18 in\frac{1}{8}\,\text{in}:

30.0 in30.0\,\text{in}

What goes wrong: using feet for one leg and inches for the other. Keep units consistent before applying geometry.

Exam Focus
  • Typical question patterns
    • “Use given plan dimensions to solve for a missing length/clearance using algebra.”
    • “Compute diagonal/offset distances using the Pythagorean theorem.”
    • “Interpret notes like ‘centered’, ‘equal spacing’, or elevation callouts and convert them into equations.”
  • Common mistakes
    • Adding/subtracting dimension-string segments incorrectly (especially mixed units like ft-in).
    • Applying the Pythagorean theorem to non-right triangles (it only works for right triangles).
    • Forgetting that elevations are relative to a datum (mixing finished floor vs structural slab references).

6.1.4 Use proportional reasoning and indirect measurement (similar triangles and right-triangle trigonometry)

Sometimes you can’t measure something directly: the top of a roof curb is out of reach, a line-of-sight distance is blocked, or a long run is unsafe to tape. Indirect measurement lets you compute what you need from what you can safely measure.

Two big tools power indirect measurement:

  • Proportional reasoning (especially similar triangles)
  • Right-triangle trigonometry (sine, cosine, tangent)
Proportional reasoning (thinking in ratios)

A proportion states that two ratios are equal:

ab=cd\frac{a}{b} = \frac{c}{d}

You use proportions constantly with scales, with layout methods, and with similar triangles.

What goes wrong: treating ratios like subtraction problems. Ratios compare by multiplication/division, not by differences.

Similar triangles for indirect measurement

Two triangles are similar if they have the same angles. Similar triangles have a powerful property: corresponding side lengths are proportional.

If triangle 1 and triangle 2 are similar, then:

side1side2=matching side1matching side2\frac{\text{side}_1}{\text{side}_2} = \frac{\text{matching side}_1}{\text{matching side}_2}

Worked example (shadow method):
A rooftop unit height is hard to measure. You measure your own height as 6 ft6\,\text{ft} and your shadow as 4 ft4\,\text{ft}. The unit’s shadow is 10 ft10\,\text{ft}. Approximate the unit height.

Set proportion (height to shadow is constant under same sun angle):

64=H10\frac{6}{4} = \frac{H}{10}

Solve:

H=10×64=15 ftH = 10\times \frac{6}{4} = 15\,\text{ft}

So unit height is about:

15 ft15\,\text{ft}

Right-triangle trigonometry for slopes, pitches, and offsets

Trigonometry connects angles to side ratios in a right triangle.

For a right triangle and an angle θ\theta:

sin⁡(θ)=oppositehypotenuse\sin(\theta) = \frac{\text{opposite}}{\text{hypotenuse}}

cos⁡(θ)=adjacenthypotenuse\cos(\theta) = \frac{\text{adjacent}}{\text{hypotenuse}}

tan⁡(θ)=oppositeadjacent\tan(\theta) = \frac{\text{opposite}}{\text{adjacent}}

In construction/HVAC, tan⁡(θ)\tan(\theta) is especially common because “rise over run” is a tangent relationship.

Worked example (finding rise from run and angle):
A condensate drain line must run with a slope angle of 2∘2^\circ over a horizontal run of 25 ft25\,\text{ft}. Approximate the vertical drop (rise) in feet.

Use tangent:

tan⁡(2∘)=drop25\tan(2^\circ) = \frac{\text{drop}}{25}

So:

drop=25tan⁡(2∘)\text{drop} = 25\tan(2^\circ)

Approximate value:

drop≈25(0.0349)=0.8725 ft\text{drop} \approx 25(0.0349) = 0.8725\,\text{ft}

Convert to inches if needed:

0.8725 ft×12=10.47 in0.8725\,\text{ft} \times 12 = 10.47\,\text{in}

So the drop is approximately:

0.87 ft0.87\,\text{ft}

What goes wrong: confusing degrees and percent grade. An angle of 2∘2^\circ is not the same as a 2%2\% grade.

Exam Focus
  • Typical question patterns
    • “Use similar triangles to find an inaccessible height/length from a measured reference.”
    • “Use tan⁡(θ)\tan(\theta) to compute rise/drop from run and an angle (or solve for angle).”
    • “Set up and solve proportions from scaled drawings or layout constraints.”
  • Common mistakes
    • Setting up the proportion with mismatched corresponding sides (shadow matched to height incorrectly).
    • Using the wrong trig function (mixing opposite/adjacent/hypotenuse).
    • Forgetting to keep angle units in degrees (or entering calculator mode incorrectly).

6.1.5 Select and use measurement tools (grade rod, ruler, tape measure, measuring cups, builder’s level)

Construction math only works if your measurements are trustworthy. Tool choice is part of the math: each tool has a typical accuracy, best-use scenario, and a “right way” to read it.

Tape measure

A tape measure is the default for field layout and rough measurements.

  • Best for: lengths over a few feet, room dimensions, equipment footprints, rough-in locations.
  • Strength: versatile and fast.
  • Limitation: accuracy drops if the tape is sagging, not straight, or hooked incorrectly.

How to use it well: Keep the tape aligned with the measurement line, pull it taut, and read at eye level to reduce parallax error.

Ruler (including steel rule)

A ruler (or steel rule) is best when you need short, precise measurements and stable referencing.

  • Best for: small offsets, fabrication, bench work, verifying small dimensions.
  • Limitation: not practical for long distances.
Builder’s level (and leveling concept)

A builder’s level is used to transfer elevations across a site or floor—crucial for equipment pads, housekeeping pad heights, and ensuring drains slope correctly.

The central idea is that the instrument establishes a horizontal line of sight. You then read elevations using a rod.

Common terms:

  • Benchmark (BM): a known elevation reference.
  • HI (height of instrument): elevation of the line of sight.

If the benchmark elevation is EBME_{BM} and the backsight rod reading is BSBS:

HI=EBM+BSHI = E_{BM} + BS

If a foresight reading is FSFS at a point, the point elevation is:

Epoint=HI−FSE_{\text{point}} = HI - FS

What goes wrong: mixing up which readings are added vs subtracted. Backsight raises you to HI; foresight subtracts down to the point.

Grade rod

A grade rod is a graduated rod used with a builder’s level (or laser level) to read elevations.

  • Best for: site grading, pad heights, trench depth control, slab penetrations that must meet an elevation.
  • Common issue: the rod must be held plumb. If it’s tilted, the reading is wrong (it reads too big).
Measuring cups

Measuring cups sound out of place in HVAC, but they show up in jobsite maintenance and construction support tasks where accurate ratios matter.

  • Best for: mixing small batches (adhesives, primers, sealants, cleaning solutions) where ratios are specified.
  • Why it matters: too strong or too weak a mix can cause failure (poor bond, inadequate cleaning, wrong cure).

What goes wrong: confusing fluid ounces, cups, and gallons, or using “eyeballing” when a ratio is specified.

Quick comparison (tool selection logic)
TaskBest toolWhy
Long linear layout across a roomTape measureFast, adequate accuracy
Small fabrication marksRuler/steel ruleBetter precision and stability
Transfer height across distanceBuilder’s level + grade rodElevation accuracy independent of ground slope
Control pad/grade elevationsGrade rodDesigned for readable elevation readings
Mix specified liquid ratiosMeasuring cupsPrevents ratio errors
Exam Focus
  • Typical question patterns
    • “Choose the correct tool for a measurement scenario and justify why.”
    • “Given level notes (BM, BS, FS), compute HI and point elevations.”
    • “Identify sources of measurement error (sag, parallax, rod not plumb).”
  • Common mistakes
    • Using a tape for elevation transfer instead of a level and rod.
    • Reading a tape at an angle (introducing systematic error).
    • Holding a grade rod tilted and trusting the reading.

6.1.6 Perform calculations and conversions with fractions, decimals, and percentages

Construction dimensions frequently live in fractions (like 38 in\frac{3}{8}\,\text{in}), while many calculations (area, volume, cost) are easier in decimals. Percentages show up in grade, waste factors, efficiency changes, and markup. Being fluent across all three forms keeps you from making “simple math” mistakes that cause real rework.

Fractions in measurement (and why mixed numbers matter)

A fraction represents part of a whole. In layout, you often see mixed numbers like 5 316 in5\,\frac{3}{16}\,\text{in}.

To do operations reliably (especially multiplication/division), convert mixed numbers to improper fractions.

If you have a bca\,\frac{b}{c}:

a bc=ac+bca\,\frac{b}{c} = \frac{ac+b}{c}

Worked example (adding lengths):
Add 3 58 in3\,\frac{5}{8}\,\text{in} and 2 316 in2\,\frac{3}{16}\,\text{in}.

Convert to sixteenths:

58=1016\frac{5}{8} = \frac{10}{16}

Now add:

3 1016+2 316=5 1316 in3\,\frac{10}{16} + 2\,\frac{3}{16} = 5\,\frac{13}{16}\,\text{in}

Common field mistake: adding numerators and denominators directly (that is never valid for adding fractions).

Decimals (when they help and when they hurt)

Decimals are great for:

  • area and volume calculations
  • cost estimates
  • unit conversions

But decimals can be awkward for layout cuts if your tools and tolerances are in fractional inches. A good habit is to calculate in decimals, then convert to the fractional precision your tools support.

Converting between fractions and decimals

To convert a fraction to a decimal, divide numerator by denominator:

316=0.1875\frac{3}{16} = 0.1875

To convert a decimal to a fraction, recognize common increments used on tape measures (halves, quarters, eighths, sixteenths). For instance:

0.75=340.75 = \frac{3}{4}

What goes wrong: rounding a decimal to the wrong fractional increment (e.g., calling 0.180.18 “about 18\frac{1}{8}” without checking).

Percentages as “per 100”

A percentage expresses a ratio out of 100.

Key conversions:

percent=decimal×100%\text{percent} = \text{decimal}\times 100\%

decimal=percent100\text{decimal} = \frac{\text{percent}}{100}

Percent increase/decrease

If an original value is AA and it changes by p%p\%:

new=A(1+p100)\text{new} = A\left(1 + \frac{p}{100}\right)

For a decrease, use 1−p1001 - \frac{p}{100}.

Worked example (waste factor):
You estimate 220 ft2220\,\text{ft}^2 of duct insulation. Add 12%12\% waste. How many square feet should you order?

order=220(1+12100)=220(1.12)=246.4 ft2\text{order} = 220\left(1 + \frac{12}{100}\right) = 220(1.12) = 246.4\,\text{ft}^2

If ordering must be whole units, you typically round up:

≈247 ft2\approx 247\,\text{ft}^2

Common mistake: calculating 12%12\% of 220220 and forgetting to add it back to the original.

Exam Focus
  • Typical question patterns
    • “Add/subtract/multiply construction measurements given in mixed fractions.”
    • “Convert between fractional inches and decimal inches/feet for calculation.”
    • “Apply percent waste/markup/discount to a quantity or cost.”
  • Common mistakes
    • Adding fractions with different denominators without finding a common denominator.
    • Converting feet-inches to decimal feet incorrectly.
    • Misinterpreting percent change (using pp instead of p100\frac{p}{100}).

6.1.7 Perform unit conversions

Unit conversion is the “glue” of construction math. HVAC projects mix units constantly: drawings may show feet and inches, equipment submittals may list metric dimensions, pressure may be in psi or kPa, and temperature may be in Fahrenheit or Celsius.

A reliable method is dimensional analysis: multiply by conversion factors written as fractions so units cancel.

Core length and area conversions you’ll use often

Common exact relationships:

1 ft=12 in1\,\text{ft} = 12\,\text{in}

1 in=25.4 mm1\,\text{in} = 25.4\,\text{mm}

Area conversion reminder: when converting lengths, area scales by the square.

1 ft2=144 in21\,\text{ft}^2 = 144\,\text{in}^2

Volume conversion reminder: volume scales by the cube.

1 ft3=1728 in31\,\text{ft}^3 = 1728\,\text{in}^3

What goes wrong: converting only one dimension of an area/volume. If you convert ft\text{ft} to in\text{in} for one side but not the other, the units won’t match.

Temperature conversions (common in HVAC)

Temperature conversions are special because they involve an offset (not just multiplication).

Between Fahrenheit and Celsius:

C=(F−32)59C = (F-32)\frac{5}{9}

F=C95+32F = C\frac{9}{5} + 32

Between Celsius and Kelvin:

K=C+273.15K = C + 273.15

Worked example (F to C):
Convert 95 ∘F95\,^{\circ}\text{F} to Celsius.

C=(95−32)59=63×59=35 ∘CC = (95-32)\frac{5}{9} = 63\times \frac{5}{9} = 35\,^{\circ}\text{C}

Common mistake: forgetting the −32-32 step.

Pressure conversions (often encountered)

In HVAC and refrigeration contexts, you may see pressure in psi or kPa.

A commonly used relationship is:

1 psi≈6.895 kPa1\,\text{psi} \approx 6.895\,\text{kPa}

Worked example (psi to kPa):
Convert 45 psi45\,\text{psi} to kPa.

45×6.895≈310.3 kPa45\times 6.895 \approx 310.3\,\text{kPa}

So approximately:

310 kPa310\,\text{kPa}

Volume and capacity conversions (jobsite relevant)

For concrete, coatings, and fluids, you may convert between cubic feet and gallons.

A U.S. liquid gallon is defined as 231 in3231\,\text{in}^3. Using 1 ft3=1728 in31\,\text{ft}^3 = 1728\,\text{in}^3:

1 ft3=1728231 gal≈7.48 gal1\,\text{ft}^3 = \frac{1728}{231}\,\text{gal} \approx 7.48\,\text{gal}

Worked example (cubic feet to gallons):
A condensate neutralizer tank holds 0.50 ft30.50\,\text{ft}^3. Approximate gallons.

0.50×7.48≈3.74 gal0.50\times 7.48 \approx 3.74\,\text{gal}

A repeatable dimensional-analysis workflow

1) Write the starting value with units.
2) Multiply by a conversion factor so the unwanted unit cancels.
3) Check that the final unit is what you want.
4) Round to the required precision.

Worked example (inches to millimeters):
Convert 3 38 in3\,\frac{3}{8}\,\text{in} to mm.

Convert to decimal inches:

3 38=3.375 in3\,\frac{3}{8} = 3.375\,\text{in}

Multiply by conversion factor:

3.375 in×25.4 mm1 in=85.725 mm3.375\,\text{in}\times \frac{25.4\,\text{mm}}{1\,\text{in}} = 85.725\,\text{mm}

Rounded to nearest mm:

86 mm86\,\text{mm}

Exam Focus
  • Typical question patterns
    • “Convert between ft-in and decimal feet, or between U.S. customary and metric.”
    • “Convert temperature between ∘F^{\circ}\text{F}, ∘C^{\circ}\text{C}, and K.”
    • “Use dimensional analysis to convert area/volume (and catch squared/cubed unit changes).”
  • Common mistakes
    • Converting area/volume as if it were length (forgetting squared/cubed scaling).
    • Treating temperature conversions like pure multiplication (ignoring the offset).
    • Dropping units during work, making it hard to detect an incorrect setup.