Medical Gas Therapy - Egan's Chapter 42 Review

Clinical Foundations and Indications for Oxygen Therapy

  • Acute Hypoxemia Definition and Diagnostic Thresholds:

    • Defined pathologically as an abnormally low level of oxygen in the arterial blood.
    • Laboratory threshold: Partial pressure of arterial oxygen (PaO2PaO_2) less than 60 mmHg60\,\text{mmHg}.
    • Pulse oximetry / saturation threshold: Arterial oxygen saturation (SaO2SaO_2) less than 90%90\% while breathing ambient room air (FiO2=0.21FiO_2 = 0.21).
  • Hypercapnia Definition:

    • Defined as an abnormally increased concentration of carbon dioxide (CO2CO_2) within the blood.
  • Cardiopulmonary Compensatory Mechanisms:

    • When blood oxygen levels decrease, both the heart and lungs increase their operational workload to compensate for the tissue oxygen deficit.
    • Properly titrated and applied oxygen (O2O_2) therapy alleviates cardiopulmonary stress and decreases overall ventilatory demand.
  • Assessment Methods for Supplemental Oxygen Need:

    • Direct arterial blood gas analysis: Evaluation of PaO2PaO_2.
    • Noninvasive and co-oximetry saturation measurement: Assessment of SaO2SaO_2 or pulse oximetry saturation (SpO2SpO_2).
    • Assessment of the comprehensive clinical situation and underlying pathophysiology.
  • Clinical Indications Beyond Diagnostic Oxygen Levels:

    • Severe physical trauma.
    • Acute myocardial infarction (MI).
    • Administration of anesthesia and monitoring during post-anesthesia recovery.
    • Acute chest pain suggestive of cardiac ischemia.
    • Documented or suspected hypoxemia.
    • Sickle cell anemia crises.

Hazards and Complications of Medical Gas Therapy

  • Primary Hazards of Oxygen Administration:

    • Oxygen toxicity.
    • Retinopathy of prematurity (ROP).
    • Depression of ventilation (DOV).
    • Fire hazard.
    • Absorption atelectasis.
  • Oxygen Toxicity Pathophysiology and Manifestations:

    • Target Organs Affected: Primarily damages the lungs (pulmonary system) and the central nervous system (CNS).
    • Determinant Risk Factors: Tissue damage is governed by two interacting variables:
    • High delivered concentration of oxygen (FiO2FiO_2).
    • Total duration and length of exposure to elevated oxygen concentrations.
    • Vicious Cycle of Oxygen Toxicity:
    • Step 1: Initial oxygen toxicity occurs due to high FiO2FiO_2 and prolonged exposure.
    • Step 2: Worsening alveolar and capillary damage leads to increased pulmonary shunting.
    • Step 3: Increased shunting causes refractory low arterial oxygen tension (PaO2PaO_2).
    • Step 4: Clinicians raise the supplemental oxygen concentration (FiO2FiO_2) in an attempt to correct the hypoxemia.
    • Step 5: The higher FiO2FiO_2 exacerbates oxygen toxicity, continuing the destructive cycle.
  • Retinopathy of Prematurity (ROP):

    • Pathological consequence of excessive arterial oxygenation in premature infants.
    • May result in permanent visual impairment and irreversible blindness.
  • Depression of Ventilation (DOV) Considerations:

    • Clinical occurrence in Chronic Obstructive Pulmonary Disease (COPD): Depression of ventilation is not typical in all COPD patients when exposed to elevated oxygen concentrations; hypoventilation is not an absolute or universal response across the entire COPD patient population.
  • Mechanism of Absorption Atelectasis:

    • High concentrations of inspired oxygen (FiO2FiO_2) wash nitrogen (N2N_2) out of the alveoli.
    • Nitrogen normally exerts a "splinting" effect that keeps alveoli patent at low partial pressures; removing nitrogen allows rapid and complete alveolar collapse (absorption atelectasis).
  • Combustion and Fire Hazard Requirements:

    • Oxygen vigorously accelerates combustion.
    • Three components required for a fire to start and continue burning (the fire triangle):
    • Oxygen (O2O_2).
    • Heat (ignition source).
    • Fuel.

Device Classifications and Low-Flow Delivery Systems

  • Inspiratory Demand and Performance Classifications:

    • A delivery system must deliver an output flow that meets or exceeds the patient's peak inspiratory demand to guarantee a stable, precise fraction of inspired oxygen (FiO2FiO_2).
    • Variable-Performance Systems: Oxygen delivery devices that provide only a fraction of the patient's inspiratory flow demand; the remainder of the inspiratory volume is drawn from ambient room air, causing FiO2FiO_2 to fluctuate with ventilatory pattern changes.
    • High-flow criteria: A true high-flow oxygen delivery system must supply a minimum total output flow of at least 60 L/min60\,\text{L/min}.
  • Nasal Cannula:

    • Operates as a low-flow, variable-performance device.
    • At an input flow rate of 4 L/min4\,\text{L/min}, delivered FiO2FiO_2 is approximately 0.360.36 (36%36\%).
  • Simple Oxygen Mask:

    • Minimum operational flow setting for adult application: 5 L/min5\,\text{L/min}.
    • Flow rates below 5 L/min5\,\text{L/min} permit the accumulation and rebreathing of expired carbon dioxide (CO2CO_2) inside the mask reservoir.
  • General Complications and Disadvantages of Oxygen Masks:

    • Localized skin irritation and breakdown over contact surfaces.
    • Risk of pulmonary aspiration if emesis occurs while wearing the appliance.
    • Potential for patient suffocation if gas flow is inadvertently occluded or disconnected.

Reservoir and Emergency Oxygen Delivery Devices

  • Partial-Rebreather Mask:

    • Reservoir device equipped with an attached gas reservoir bag.
    • Valve configuration: Contains 00 valves (no one-way valves between the bag and mask or on the exhalation ports).
    • Delivered oxygen concentration range: FiO2=0.40−0.70FiO_2 = 0.40-0.70 (40%−70%40\%-70\%).
  • Non-Rebreather Mask:

    • Utilized for the administration of high concentrations of supplemental oxygen.
    • Delivered oxygen concentration range: Approximately FiO2=0.60−0.80FiO_2 = 0.60-0.80.
    • Valve configuration: Incorporates one-way valves (flapper valves) that prevent exhaled gases from entering the reservoir bag and prevent ambient room air entrainment through the mask exhalation ports.
    • Distinguishing feature: Unlike the partial-rebreather mask (which has zero valves), the non-rebreather mask utilizes one-way valves to prevent rebreathing and room air dilution.
  • High-Flow Nasal Cannula Classification:

    • A high-flow nasal cannula is categorized as an active high-flow delivery device and is NOT classified as a reservoir device.
  • Emergency and Resuscitation Delivery Systems:

    • Standard appliance used in resuscitation or emergency situations to administer close to 100%100\% oxygen (FiO2≈1.0FiO_2 \approx 1.0): Bag-mask device (BMD / BVM - Bag-Valve-Mask).
    • Initial FiO2FiO_2 indicated during acute emergency resuscitation: FiO2=1.0FiO_2 = 1.0 (100%100\%).

Air-Entrainment Systems and Flow Dynamics

  • Operating Principles of Air-Entrainment Masks (AEM):

    • Deliver a fixed FiO2FiO_2 by utilizing high-velocity oxygen gas passing through a fixed jet nozzle to entrain atmospheric room air through adjustable air-entrainment ports.
    • Adjusting Flowmeter Settings: Increasing the delivered oxygen flow from the flowmeter does not alter the delivered FiO2FiO_2; it proportionally increases the total output flow delivered to the patient.
  • Effects of Downstream Resistance and Port Obstruction:

    • Back pressure generated by downstream resistance or obstructions in the tubing causes: Delivered oxygen concentration (FiO2FiO_2) to increase, and total delivered output flow to decrease.
    • Direct obstruction of the air-entrainment ports or pathway causes: Delivered oxygen concentration to increase, total system output flow to decrease, and the delivered FiO2FiO_2 to become unstable or variable.
  • Step-by-Step Flow Calculations for Air-Entrainment Systems:

    • Calculation Parameters for an AEM delivering 35%35\% oxygen at an input flow of 7 L/min7\,\text{L/min}:
    • Air-to-Oxygen Entrainment Ratio: An FiO2FiO_2 of 0.350.35 (35%35\%) utilizes an approximate 5:15:1 ratio (5 parts air5\,\text{parts air} to 1 part O21\,\text{part } O_2).
    • Total Flow Multiplier: Total ratio parts equal 5+1=65 + 1 = 6.
    • Total System Output Flow:       Total Flow=(5+1)×7 L/min=6×7 L/min=42 L/min\text{Total Flow} = (5 + 1) \times 7\,\text{L/min} = 6 \times 7\,\text{L/min} = 42\,\text{L/min}
    • Patient Inspiratory Demand Evaluation:
    • Patient Parameters: Respiratory Rate (RRRR) = 14/min14/\text{min}; Tidal Volume (VTV_T) = 500 mL500\,\text{mL} (0.5 L0.5\,\text{L}).
    • Minute Ventilation (MVMV) Calculation:       MV=RR×VT=14/min×0.5 L=7 L/minMV = RR \times V_T = 14/\text{min} \times 0.5\,\text{L} = 7\,\text{L/min}
    • Estimated Peak Inspiratory Demand:       Peak Inspiratory Demand=MV×3=7 L/min×3=21 L/min\text{Peak Inspiratory Demand} = MV \times 3 = 7\,\text{L/min} \times 3 = 21\,\text{L/min}
    • Performance Verification: Because the total system output flow (42 L/min42\,\text{L/min}) exceeds the patient's estimated peak inspiratory demand (21 L/min21\,\text{L/min}), the system functions as a true fixed-performance device and maintains an accurate 35%35\% FiO2FiO_2.

Oxygen Weaning and Titration Protocols

  • Weaning Criteria:
    • Oxygen weaning protocols begin when clinical indicators demonstrate that oxygenation has stabilized or improved, indicating the patient no longer requires the current level of supplemental therapy.
    • Weaning is executed by systematically reducing the delivered FiO2FiO_2 while monitoring target saturation parameters.