Water Technology

Water Resources and Distribution

  • Global Water Availability:
    • Water covers nearly 70%70\% of the Earth's surface.
    • The total volume of the hydrosphere is estimated at approximately 1360 million cubic kilometer1360\text{ million cubic kilometer} (1.3×1018 m31.3 \times 10^{18}\,\text{m}^3).
    • About 97%97\% of Earth's water resides in oceans and inland seas, rendering it unfit for human consumption due to its high salinity.
    • Only 3%3\% of global water is freshwater.
    • Of this 3%3\% freshwater:
    • 2%2\% is locked in glaciers and polar ice caps.
    • Only 1%1\% is accessible as freshwater in rivers, lakes, streams, reservoirs, and groundwater for human consumption.

Distribution of Water on Earth

  • Detailed Breakdown of Earth's Water Distribution:

    • Total Global Water:
    • Oceans: 97%97\%
    • Other Water Sources: 3%3\%
    • Breakdown of Freshwater (3%3\% Other):
    • Icecaps, Glaciers, and Inland seas: 77%77\%
    • Ground water: 22%22\%
    • Other accessible sources: 1%1\%
    • Breakdown of Accessible Freshwater (1%1\% Other):
    • Lakes: 61%61\%
    • Atmosphere and Soil moisture: 39%39\%
    • Rivers: less than 410%\frac{4}{10}\% (0.4%0.4\%
  • Chief Sources of Water:

    • Surface Water: Includes natural bodies such as oceans, lakes, ponds, rivers, and streams.
    • Ground Water: Water stored underground in soil pore spaces and fractures of rock formations, replenished via natural precipitation recharge and artificial recharge wells.
    • Rain Water: Primary source of direct precipitation.

Impurities in Water and Effects on Minerals

  • Classification of Impurities:

    • Water is a versatile solvent capable of dissolving numerous organic and inorganic substances. Impurities are classified into four main categories based on size and physical state:
  • Dissolved Impurities:

    • Dissolved Salts: Carbonates, bicarbonates, nitrates, sulphates, and chlorides of calcium (Ca2+\text{Ca}^{2+}), magnesium (Mg2+\text{Mg}^{2+}), sodium (Na+\text{Na}^+), potassium (K+\text{K}^+), iron (Fe2+/Fe3+\text{Fe}^{2+}/\text{Fe}^{3+}), manganese (Mn2+\text{Mn}^{2+}), and aluminium (Al3+\text{Al}^{3+}).
    • Dissolved Gases: Oxygen (O2\text{O}_2), carbon dioxide (CO2\text{CO}_2), sulphur dioxide (SO2\text{SO}_2), ammonia (NH3\text{NH}_3), nitrogen (N2\text{N}_2), and nitrogen oxides (NOx\text{NO}_x).
    • Organic Compounds: Carbohydrates, amino compounds, and industrial organic residues.
  • Colloidal Impurities:

    • Particle size range: 10−4 mm10^{-4}\,\text{mm} to 10−6 mm10^{-6}\,\text{mm}.
    • Inorganic Colloids: Clay particles, iron (Fe\text{Fe}) oxides, and manganese (Mn\text{Mn}) oxides.
    • Organic Colloids: Natural organic macromolecules, paper mill processing wastes, china clay wastes, and finely divided sewage solids.
  • Suspended Impurities:

    • Particle size greater than 100 nm100\,\text{nm}.
    • Can be separated via simple gravity settling or filtration.
    • Organic Suspended Matter: Vegetable and animal matter, wood fragments, decaying leaves, and oil globules.
    • Inorganic Suspended Matter: Sand, silica, and coarse clay particles.
    • Impact: Suspended particles impart turbidity and undesirable color to water.
  • Living Organisms (Micro-Organisms):

    • Includes bacteria, algae, viruses, protozoa, and microfungi.
    • Factors Promoting Growth: Presence of nutrients (e.g., domestic sewage), exposure to sunlight (promotes algal blooms), ferruginous environments (iron bacteria like Sphaerotilus in iron pipes), and anaerobic conditions (sulphur bacteria).
  • Effect of Water on Rocks and Minerals (Chemical Weathering):

    • Dissolution: Direct solubility of salts creates cavities in rock strata, leading to structural weakening and eventual collapse (e.g., direct dissolution of halite, NaCl\text{NaCl}).
    • Hydration: Moisture absorption under humid conditions causes mineral swelling, volume expansion, and subsequent mechanical disintegration:
    • Hydration of Anhydrite to Gypsum:       CaSO4+2H2O→HydrationCaSO4⋅2H2O\text{CaSO}_4 + 2\text{H}_2\text{O} \xrightarrow{\text{Hydration}} \text{CaSO}_4 \cdot 2\text{H}_2\text{O}
    • Hydration of Bauxite to Hydrated Aluminium Oxide:       Al2O3+3H2O→HydrationAl2O3⋅3H2O\text{Al}_2\text{O}_3 + 3\text{H}_2\text{O} \xrightarrow{\text{Hydration}} \text{Al}_2\text{O}_3 \cdot 3\text{H}_2\text{O}
    • Hydrolysis: Dissociation of water into H+\text{H}^+ and OH−\text{OH}^- ions, reacting with mineral silicates to yield clay minerals:
    • Decomposition of Orthoclase:       KAlSi3O8+H2O→HAlSi3O8+KOH\text{KAlSi}_3\text{O}_8 + \text{H}_2\text{O} \rightarrow \text{HAlSi}_3\text{O}_8 + \text{KOH}
    • Recombination of Acid Silt Clay:       2HAlSi3O8+8H2O→Al2O3⋅3H2O+6H2SiO32\text{HAlSi}_3\text{O}_8 + 8\text{H}_2\text{O} \rightarrow \text{Al}_2\text{O}_3 \cdot 3\text{H}_2\text{O} + 6\text{H}_2\text{SiO}_3
    • Carbonation: Atmospheric carbon dioxide dissolves in rainwater forming carbonic acid, which reacts with insoluble minerals to convert them into soluble bicarbonates:
    • Formation of Carbonic Acid:       H2O+CO2→H2CO3\text{H}_2\text{O} + \text{CO}_2 \rightarrow \text{H}_2\text{CO}_3
    • Solubilization of Calcite:       CaCO3+H2O+CO2→Ca(HCO3)2\text{CaCO}_3 + \text{H}_2\text{O} + \text{CO}_2 \rightarrow \text{Ca(HCO}_3)_2

Hardness of Water and Its Classification

  • Definition of Hardness:

    • Characteristic property of water that prevents or retards the formation of lather with soap.
    • Quantitatively defined as the soap-consuming capacity of water.
  • Cause of Hardness:

    • Presence of dissolved soluble salts of calcium (Ca2+\text{Ca}^{2+}), magnesium (Mg2+\text{Mg}^{2+}), and other multivalent heavy metal ions (Al3+\text{Al}^{3+}, Fe3+\text{Fe}^{3+}, Mn2+\text{Mn}^{2+}).
  • Soap Reaction Mechanism:

    • When hard water is treated with soap (sodium or potassium salts of higher fatty acids, such as sodium stearate, C17H35COONa\text{C}_{17}\text{H}_{35}\text{COONa}), it reacts with soluble calcium and magnesium salts to form an insoluble white curd/scum (calcium or magnesium stearate) instead of producing foam:
    • Reaction with Calcium Chloride (CaCl2\text{CaCl}_2):       2C17H35COONa+CaCl2→(C17H35COO)2Ca↓+2NaCl2\text{C}_{17}\text{H}_{35}\text{COONa} + \text{CaCl}_2 \rightarrow (\text{C}_{17}\text{H}_{35}\text{COO})_2\text{Ca} \downarrow + 2\text{NaCl}
    • Reaction with Magnesium Sulphate (MgSO4\text{MgSO}_4):       2C17H35COONa+MgSO4→(C17H35COO)2Mg↓+Na2SO42\text{C}_{17}\text{H}_{35}\text{COONa} + \text{MgSO}_4 \rightarrow (\text{C}_{17}\text{H}_{35}\text{COO})_2\text{Mg} \downarrow + \text{Na}_2\text{SO}_4
  • Comparison Between Hard Water and Soft Water:

S.NoHard WaterSoft Water
1Does not form lather easily with soap; forms a white precipitate or scum.Produces lather or foam easily with soap.
2Contains dissolved soluble salts of Ca2+\text{Ca}^{2+}, Mg2+\text{Mg}^{2+}, and heavy metals (Al3+\text{Al}^{3+}, Fe3+\text{Fe}^{3+}, Mn2+\text{Mn}^{2+}).Free from dissolved salts of calcium and magnesium.
3Depresses the cleaning action of soap, leading to substantial waste during washing and bathing.Cleaning quality of soap is unimpaired; highly efficient for cleaning.
4Boiling point is elevated due to dissolved salts; requires more fuel and time for cooking.Requires less fuel and time for cooking.
  • Types of Hardness:

    • Temporary Hardness (Carbonate / Alkaline Hardness):
    • Cause: Presence of dissolved bicarbonates of calcium and magnesium [Ca(HCO3)2\text{Ca(HCO}_3)_2, Mg(HCO3)2\text{Mg(HCO}_3)_2], as well as trace carbonates and hydroxides.
    • Characteristics: Termed alkaline hardness because it contributes to water alkalinity and can be quantitatively determined by acid-base titration using methyl orange indicator.
    • Removal Method: Easily removed by simple thermal boiling. Boiling decomposes soluble bicarbonates into insoluble carbonates or hydroxides that precipitate out:       Ca(HCO3)2→boilCaCO3↓+H2O+CO2↑\text{Ca(HCO}_3)_2 \xrightarrow{\text{boil}} \text{CaCO}_3 \downarrow + \text{H}_2\text{O} + \text{CO}_2 \uparrowMg(HCO3)2→boilMg(OH)2↓+H2O+2CO2↑\text{Mg(HCO}_3)_2 \xrightarrow{\text{boil}} \text{Mg(OH)}_2 \downarrow + \text{H}_2\text{O} + 2\text{CO}_2 \uparrow
    • Permanent Hardness (Non-Carbonate / Non-Alkaline Hardness):
    • Cause: Presence of dissolved chlorides, sulphates, and nitrates of calcium, magnesium, iron, and heavy metals (e.g., CaCl2\text{CaCl}_2, CaSO4\text{CaSO}_4, MgCl2\text{MgCl}_2, MgSO4\text{MgSO}_4, Ca(NO3)2\text{Ca(NO}_3)_2).
    • Removal Method: Cannot be removed by boiling. Requires external chemical treatment processes such as the Lime-Soda process, Zeolite process, or Ion-Exchange process.
  • Comparison Between Temporary and Permanent Hardness:

PropertyTemporary HardnessPermanent Hardness
Alternative NameCarbonate hardness or alkaline hardness.Non-carbonate or non-alkaline hardness.
Causative CompoundsBicarbonates and carbonates of calcium and magnesium.Chlorides, sulphates, and nitrates of calcium, magnesium, iron, and heavy metals.
Removal MethodRemovable by simple boiling.Requires chemical methods (Lime-Soda, Zeolite, Ion-Exchange).

Alkalinity and Its Chemical Equilibrium

  • Definition of Alkalinity:

    • Measure of the acid-neutralizing capacity of water.
    • Aggregate quantity representing the sum of all titratable bases present in the water sample.
  • Anions Responsible for Alkalinity:

    • Primarily driven by Carbonates (CO32−\text{CO}_3^{2-}), Bicarbonates (HCO3−\text{HCO}_3^-), and Hydroxide (OH−\text{OH}^-) anions.
    • Borates, phosphates, silicates, and organic bases also contribute if present.
    • Quantitatively expressed in terms of CaCO3\text{CaCO}_3 equivalents.
  • Equilibrium Reactions and pH Dependence:

    • System equilibria in natural water systems:     CO2(g)⇌CO2(aq)\text{CO}_{2(g)} \rightleftharpoons \text{CO}_{2(aq)}CO2(aq)+H2O⇌H2CO3\text{CO}_{2(aq)} + \text{H}_2\text{O} \rightleftharpoons \text{H}_2\text{CO}_3H2CO3⇌H++HCO3−,pKa=6.3\text{H}_2\text{CO}_3 \rightleftharpoons \text{H}^+ + \text{HCO}_3^-, \quad pK_a = 6.3HCO3−⇌H++CO32−,pKa=10.3\text{HCO}_3^- \rightleftharpoons \text{H}^+ + \text{CO}_3^{2-}, \quad pK_a = 10.3
    • Speciation Dynamics:
    • At pH=10.3pH = 10.3, [HCO3−]=[CO32−]\text{[HCO}_3^-] = \text{[CO}_3^{2-]}.
    • Carbonate ion (CO32−\text{CO}_3^{2-}) dominates at pH>10.3pH > 10.3
    • Bicarbonate ion (HCO3−\text{HCO}_3^-) dominates in the range 6.3<pH<10.36.3 < pH < 10.3
    • Bicarbonate buffering stabilizes the pH of most natural waters between 66 and 99

Estimation of Hardness via EDTA Titration

  • Principle of Complexometric Titration:

    • Involves titrating metal cations with complexing agents (Lewis bases) to form soluble coordination complexes.
    • Multidentate ligands (chelating agents) form multiple coordinate covalent bonds per ligand, producing ring structures (chelates) with very large formation constants (KfK_f).
  • Role of EDTA:

    • Ethylene diamine tetraacetic acid (EDTA) is a tetrabasic acid.
    • In its fully ionized tetrabasic form, EDTA acts as a hexadentate ligand (donating 6 electron pairs: 2 from amine nitrogen atoms and 4 from carboxylate oxygen atoms).
    • Reacts with metal cations in a strict 1:11:1 stoichiometric ratio.
  • Titration Reagents and Conditions:

    • Titrant: Disodium salt of EDTA (Na2H2Y\text{Na}_2\text{H}_2\text{Y}), which dissociates in aqueous solution into 2Na+2\text{Na}^+ and H2Y2−\text{H}_2\text{Y}^{2-}.
    • Buffer: Basic ammonium chloride-ammonium hydroxide (NH4Cl−NH4OH\text{NH}_4\text{Cl}-\text{NH}_4\text{OH}) buffer solution maintained strictly at pH=10pH = 10.
    • Indicator: Eriochrome Black T (EBT), chemically known as sodium 1-(1-hydroxy-2-naphthylazo)-6-nitro-2-naphthol-4-sulfonate (NaH2D\text{NaH}_2\text{D}).
  • Chemical Reactions and Mechanism:

    • Hardness ion reaction with EDTA:     Ca2+(aq)+H2Y2−(aq)→CaY2−(aq)+2H+(aq)\text{Ca}^{2+}(aq) + \text{H}_2\text{Y}^{2-}(aq) \rightarrow \text{CaY}^{2-}(aq) + 2\text{H}^+(aq)Mg2+(aq)+H2Y2−(aq)→MgY2−(aq)+2H+(aq)\text{Mg}^{2+}(aq) + \text{H}_2\text{Y}^{2-}(aq) \rightarrow \text{MgY}^{2-}(aq) + 2\text{H}^+(aq)
    • Generation of 2H+2\text{H}^+ per mole of metal complexed demonstrates why buffer addition is required to prevent pH drop, which would otherwise destabilize the EDTA-metal complex.
    • Indicator Color Behavior across pH ranges:
    • pH<6.3pH < 6.3: Red (H2D−\text{H}_2\text{D}^-)
    • pH=8−10pH = 8 - 10: Blue (HD2−\text{HD}^{2-})
    • pH>11.5pH > 11.5: Yellowish Orange (D3−\text{D}^{3-})
    • Complexation with Indicator at pH=10pH = 10:
    • Before titration, adding EBT to water containing Mg2+\text{Mg}^{2+} forms an unstable wine-red complex:       Mg2++HD2− (Blue)→MgD− (Wine Red)+H+\text{Mg}^{2+} + \text{HD}^{2-}\text{ (Blue)} \rightarrow \text{MgD}^-\text{ (Wine Red)} + \text{H}^+
    • Titration Endpoint Mechanism:
    • As EDTA is added from the burette, it first complexed all free Ca2+\text{Ca}^{2+} and Mg2+\text{Mg}^{2+} ions.
    • Once all free ions are consumed, EDTA displaces EBT from the weaker MgD−\text{MgD}^- complex:       EDTA+MgD− (Wine Red)→EDTA-Mg2+ (Colourless)+HD2− (Blue)\text{EDTA} + \text{MgD}^-\text{ (Wine Red)} \rightarrow \text{EDTA-Mg}^{2+}\text{ (Colourless)} + \text{HD}^{2-}\text{ (Blue)}
    • The sharp end-point color change is from Wine Red to Distinct Blue.
  • Relative Stability Hierarchy of Complexes:EDTA-Ca2+>EDTA-Mg2+>EBT-Mg2+>EBT-Ca2+\text{EDTA-Ca}^{2+} > \text{EDTA-Mg}^{2+} > \text{EBT-Mg}^{2+} > \text{EBT-Ca}^{2+}

Quantitative Measurement and Calculations of Hardness

  • Choice of Calcium Carbonate (CaCO3\text{CaCO}_3) as Standard:

    • Hardness is universally calculated in terms of CaCO3\text{CaCO}_3 equivalents due to two primary reasons:
    • Its molecular weight is exactly 100 g/mol100\,\text{g/mol} (equivalent weight is exactly 50 g/eq50\,\text{g/eq}), simplifying numerical calculations.
    • It is the most insoluble salt that can be precipitated in industrial water treatment processes.
  • Units of Hardness and Interrelationships:

    • Parts per million (ppm): Number of parts by weight of CaCO3\text{CaCO}_3 equivalent hardness per 10610^6 parts by weight of water.     1 ppm=1 part of CaCO3 eq. hardness in 106 parts of water1\,\text{ppm} = 1\text{ part of }\text{CaCO}_3\text{ eq. hardness in } 10^6\text{ parts of water}
    • Milligrams per liter (mg/L): Number of milligrams of CaCO3\text{CaCO}_3 equivalent hardness per liter of water.     1 mg/L=1 mg of CaCO3 eq. hardness per liter of water1\,\text{mg/L} = 1\,\text{mg of }\text{CaCO}_3\text{ eq. hardness per liter of water}
    • Since 1 L of water=1 kg=1000 g=106 mg1\,\text{L of water} = 1\,\text{kg} = 1000\,\text{g} = 10^6\,\text{mg}, 1 mg/L=1 mg per 106 mg of water=1 ppm1\,\text{mg/L} = 1\,\text{mg per } 10^6\,\text{mg of water} = 1\,\text{ppm}.     1 ppm=1 mg/L\mathbf{1\,\text{ppm} = 1\,\text{mg/L}}
  • Mathematical Formulas for Hardness Calculation:

    • Formula for CaCO3\text{CaCO}_3 Equivalent:     Equivalent of CaCO3=Mass of hardness producing substance×Chemical equivalent of CaCO3Chemical equivalent of hardness producing substance\text{Equivalent of CaCO}_3 = \frac{\text{Mass of hardness producing substance} \times \text{Chemical equivalent of CaCO}_3}{\text{Chemical equivalent of hardness producing substance}}
    • Chemical Equivalents Definitions:     Chemical equivalent of CaCO3=50\text{Chemical equivalent of CaCO}_3 = 50Chemical equivalent of salt=Molecular weightValency\text{Chemical equivalent of salt} = \frac{\text{Molecular weight}}{\text{Valency}}Chemical equivalent of acid=Molecular weightBasicity (replaceable H+)\text{Chemical equivalent of acid} = \frac{\text{Molecular weight}}{\text{Basicity (replaceable } \text{H}^+\text{)}}Chemical equivalent of base=Molecular weightAcidity (replaceable OH−)\text{Chemical equivalent of base} = \frac{\text{Molecular weight}}{\text{Acidity (replaceable } \text{OH}^-\text{)}}
    • Multiplication Factor:Multiplication Factor=Chemical equivalent of CaCO3Chemical equivalent of substance=Eq. Wt. of CaCO3Eq. Wt. of substance\text{Multiplication Factor} = \frac{\text{Chemical equivalent of CaCO}_3}{\text{Chemical equivalent of substance}} = \frac{\text{Eq. Wt. of CaCO}_3}{\text{Eq. Wt. of substance}}Equivalent of CaCO3=Mass of substance×Multiplication Factor\text{Equivalent of CaCO}_3 = \text{Mass of substance} \times \text{Multiplication Factor}
  • Table of Molar Mass, Chemical Equivalents, and Multiplication Factors:

Dissolved Salt / Ion / ImpurityMolar Mass (g/mol\text{g/mol})Chemical EquivalentMultiplication Factor
Ca(HCO3)2\text{Ca(HCO}_3)_21621622=81\frac{162}{2} = 81100162\frac{100}{162}
Mg(HCO3)2\text{Mg(HCO}_3)_21461462=73\frac{146}{2} = 73100146\frac{100}{146}
CaSO4\text{CaSO}_41361362=68\frac{136}{2} = 68100136\frac{100}{136}
CaCl2\text{CaCl}_21111112=55.5\frac{111}{2} = 55.5100111\frac{100}{111}
MgSO4\text{MgSO}_41201202=60\frac{120}{2} = 60100120\frac{100}{120}
MgCl2\text{MgCl}_295952=47.5\frac{95}{2} = 47.510095\frac{100}{95}
CaCO3\text{CaCO}_31001002=50\frac{100}{2} = 50100100=1\frac{100}{100} = 1
MgCO3\text{MgCO}_384842=42\frac{84}{2} = 4210084\frac{100}{84}
Mg(NO3)2\text{Mg(NO}_3)_21481482=74\frac{148}{2} = 74100148\frac{100}{148}
Ca2+\text{Ca}^{2+}40402=20\frac{40}{2} = 2010040\frac{100}{40}
Mg2+\text{Mg}^{2+}24242=12\frac{24}{2} = 1210024\frac{100}{24}
HCO3−\text{HCO}_3^-61611=61\frac{61}{1} = 611002×61=100122\frac{100}{2 \times 61} = \frac{100}{122}
CO32−\text{CO}_3^{2-}60602=30\frac{60}{2} = 3010060\frac{100}{60}
OH−\text{OH}^-17171=17\frac{17}{1} = 171002×17=10034\frac{100}{2 \times 17} = \frac{100}{34}
H+\text{H}^+111002\frac{100}{2}
CO2\text{CO}_244442=22\frac{44}{2} = 2210044\frac{100}{44}
HCl\text{HCl}36.536.51=36.5\frac{36.5}{1} = 36.51002×36.5=10073\frac{100}{2 \times 36.5} = \frac{100}{73}
H2SO4\text{H}_2\text{SO}_498982=49\frac{98}{2} = 4910098\frac{100}{98}
FeSO4⋅7H2O\text{FeSO}_4 \cdot 7\text{H}_2\text{O}2782782=139\frac{278}{2} = 139100278\frac{100}{278}
Al2(SO4)3\text{Al}_2(\text{SO}_4)_33423426=57\frac{342}{6} = 57100×3342=5057\frac{100 \times 3}{342} = \frac{50}{57}
NaAlO2\text{NaAlO}_282821=82\frac{82}{1} = 8210082×2=100164\frac{100}{82 \times 2} = \frac{100}{164}
  • Solved Example 1:

    • Problem: A water sample contains 248 mg CaSO4248\,\text{mg }\text{CaSO}_4 per liter. Calculate the hardness in terms of CaCO3\text{CaCO}_3 equivalent.
    • Solution:
    • Concentration of CaSO4=248 mg/L\text{CaSO}_4 = 248\,\text{mg/L}
    • Formula:       Equivalents of CaCO3=Mass of CaSO4×Eq. Wt. of CaCO3Eq. Wt. of CaSO4\text{Equivalents of CaCO}_3 = \frac{\text{Mass of }\text{CaSO}_4 \times \text{Eq. Wt. of }\text{CaCO}_3}{\text{Eq. Wt. of }\text{CaSO}_4}
    • Calculation:       Equivalents of CaCO3=248×5068=248×10021362=182.35 ppm\text{Equivalents of CaCO}_3 = \frac{248 \times 50}{68} = \frac{248 \times \frac{100}{2}}{\frac{136}{2}} = 182.35\,\text{ppm}
  • Solved Example 2:

    • Problem: A water sample contains Ca(HCO3)2=32.4 mg/L\text{Ca(HCO}_3)_2 = 32.4\,\text{mg/L}, Mg(HCO3)2=29.2 mg/L\text{Mg(HCO}_3)_2 = 29.2\,\text{mg/L}, and CaSO4=13.5 mg/L\text{CaSO}_4 = 13.5\,\text{mg/L}. Calculate the temporary, permanent, and total hardness of water.
    • Step-by-Step Conversion Table:
ConstituentAmount (mg/L\text{mg/L})Mol. Wt.Eq. Wt.CaCO3\text{CaCO}_3 Eq. (mg/L\text{mg/L})
Ca(HCO3)2\text{Ca(HCO}_3)_232.41628132.4×100162=20 mg/L32.4 \times \frac{100}{162} = 20\,\text{mg/L}
Mg(HCO3)2\text{Mg(HCO}_3)_229.21467329.2×100146=20 mg/L29.2 \times \frac{100}{146} = 20\,\text{mg/L}
CaSO4\text{CaSO}_413.51366813.5×100136=9.9 mg/L13.5 \times \frac{100}{136} = 9.9\,\text{mg/L}
  • Final Hardness Values:
    • Temporary Hardness:Temporary Hardness=Ca(HCO3)2+Mg(HCO3)2=20+20=40 mg/L CaCO3 Eq. (or ppm)\text{Temporary Hardness} = \text{Ca(HCO}_3)_2 + \text{Mg(HCO}_3)_2 = 20 + 20 = 40\,\text{mg/L CaCO}_3\text{ Eq. (or ppm)}
    • Permanent Hardness:Permanent Hardness=CaSO4=9.9 mg/L CaCO3 Eq. (or ppm)\text{Permanent Hardness} = \text{CaSO}_4 = 9.9\,\text{mg/L CaCO}_3\text{ Eq. (or ppm)}
    • Total Hardness:Total Hardness=Temporary Hardness+Permanent Hardness=40+9.9=49.9 mg/L CaCO3 Eq. (or ppm)\text{Total Hardness} = \text{Temporary Hardness} + \text{Permanent Hardness} = 40 + 9.9 = 49.9\,\text{mg/L CaCO}_3\text{ Eq. (or ppm)}

Softening of Hard Water: External and Internal Treatment

Treatment of Hard Water Methods

  • Classification of Water Softening Methods:

    • External Treatment:
    1. Lime-Soda Process
    2. Zeolite Process
    3. Ion Exchange (Demineralization) Process
    • Internal Treatment:
    1. Colloidal Conditioning
    2. Phosphate Conditioning
    3. Calgon Conditioning
  • Lime-Soda Process (External Method):

    • Principle: All soluble hardness-causing salts are chemically converted into insoluble precipitates using calculated quantities of lime [Ca(OH)2\text{Ca(OH)}_2] and soda [Na2CO3\text{Na}_2\text{CO}_3]. Coagulants are added to agglomerate finely divided precipitates.
    • Chemical Reactions:
    • Removal of Temporary Hardness by Lime:Ca(HCO3)2+Ca(OH)2→2CaCO3↓+2H2O\text{Ca(HCO}_3)_2 + \text{Ca(OH)}_2 \rightarrow 2\text{CaCO}_3 \downarrow + 2\text{H}_2\text{O}Mg(HCO3)2+2Ca(OH)2→Mg(OH)2↓+2CaCO3↓+2H2O\text{Mg(HCO}_3)_2 + 2\text{Ca(OH)}_2 \rightarrow \text{Mg(OH)}_2 \downarrow + 2\text{CaCO}_3 \downarrow + 2\text{H}_2\text{O}
    • Removal of Permanent Magnesium Hardness by Lime:MgCl2+Ca(OH)2→Mg(OH)2↓+CaCl2\text{MgCl}_2 + \text{Ca(OH)}_2 \rightarrow \text{Mg(OH)}_2 \downarrow + \text{CaCl}_2MgSO4+Ca(OH)2→Mg(OH)2↓+CaSO4\text{MgSO}_4 + \text{Ca(OH)}_2 \rightarrow \text{Mg(OH)}_2 \downarrow + \text{CaSO}_4
    • Removal of Dissolved Iron and Aluminium Salts by Lime:FeSO4+Ca(OH)2→Fe(OH)2↓+CaSO4\text{FeSO}_4 + \text{Ca(OH)}_2 \rightarrow \text{Fe(OH)}_2 \downarrow + \text{CaSO}_42Fe(OH)2+H2O+O→2Fe(OH)3↓2\text{Fe(OH)}_2 + \text{H}_2\text{O} + \text{O} \rightarrow 2\text{Fe(OH)}_3 \downarrowAl2(SO4)3+3Ca(OH)2→2Al(OH)3↓+3CaSO4\text{Al}_2(\text{SO}_4)_3 + 3\text{Ca(OH)}_2 \rightarrow 2\text{Al(OH)}_3 \downarrow + 3\text{CaSO}_4
    • Removal of Free Mineral Acids by Lime:2HCl+Ca(OH)2→CaCl2+2H2O2\text{HCl} + \text{Ca(OH)}_2 \rightarrow \text{CaCl}_2 + 2\text{H}_2\text{O}H2SO4+Ca(OH)2→CaSO4+2H2O\text{H}_2\text{SO}_4 + \text{Ca(OH)}_2 \rightarrow \text{CaSO}_4 + 2\text{H}_2\text{O}
    • Removal of Dissolved Gases by Lime:Ca(OH)2+CO2→CaCO3↓+H2O\text{Ca(OH)}_2 + \text{CO}_2 \rightarrow \text{CaCO}_3 \downarrow + \text{H}_2\text{O}Ca(OH)2+H2S→CaS↓+2H2O\text{Ca(OH)}_2 + \text{H}_2\text{S} \rightarrow \text{CaS} \downarrow + 2\text{H}_2\text{O}
    • Removal of Permanent Calcium Hardness by Soda:CaCl2+Na2CO3→CaCO3↓+2NaCl\text{CaCl}_2 + \text{Na}_2\text{CO}_3 \rightarrow \text{CaCO}_3 \downarrow + 2\text{NaCl}CaSO4+Na2CO3→CaCO3↓+Na2SO4\text{CaSO}_4 + \text{Na}_2\text{CO}_3 \rightarrow \text{CaCO}_3 \downarrow + \text{Na}_2\text{SO}_4
  • Types of Cold Lime-Soda Softeners:

    • Intermittent Type: Batch process equipment operating periodically.

Intermittent cold lime-soda softener

  • Conventional Type: Continuous operation softener with paddle stirrers and fiber filters.

Conventional type of lime-soda softener

  • Catalyst or Spiractor Type: Uses crushed calcite/green sand as a bed catalyst for rapid crystallization.

Catalyst or spiractor type cold lime-soda water softener

  • Sludge Blanket Type: Continuous process utilizing a suspended sludge layer to enhance contact.

    • Hot Lime-Soda Process:
  • Performed at elevated temperatures between 80∘C80^\circ\text{C} and 150∘C150^\circ\text{C}.

  • Advantages of Elevated Temperature:

    • Chemical reaction rates proceed substantially faster.
    • Softening capacity per unit volume is increased.
    • No external coagulant is needed because precipitates settle rapidly.
    • Dissolved gases (CO2\text{CO}_2, O2\text{O}_2) are driven out of solution.
    • Viscosity of softened water is lowered, accelerating filtration rates.
    • Residual hardness is reduced to 15−30 ppm15 - 30\,\text{ppm}.

Effect of temperature on rate of precipitation of CaCO3 and Mg(OH)2

Continuous Hot Lime-Soda Softener

  • Advantages of Lime-Soda Process:

    • Highly economical.
    • Increases water pH, significantly reducing distribution pipe corrosion.
    • Reduces total mineral content in water.
    • High alkalinity reduces pathogenic bacterial counts.
  • Disadvantages of Lime-Soda Process:

    • Requires skilled supervision and precise operational dosage.
    • Large volumes of sludge generated pose disposal problems.
    • Residual hardness of 15 ppm15\,\text{ppm} is too high for high-pressure boilers.
  • Ion Exchange / Demineralization / Deionization Process:

    • Uses insoluble, cross-linked, high molecular weight organic polymers with microporous structures and acidic or basic functional groups.
    • Essential Properties of Ion-Exchange Resins:
    • Non-toxic and non-discoloring.
    • High ion-exchange capacity.
    • High physical durability and resistance to chemical attack.
    • Economical, easily backwashed, and regenerated.
    • High surface area per unit volume.
  • Cation Exchange Resins (R-H+\text{R-H}^+):

    • Styrene-divinylbenzene copolymers containing acidic functional groups (-SO3H\text{-SO}_3\text{H} or -COOH\text{-COOH}).
    • Commercial examples: Amberlite IR-120, Dowex-50.
    • Reactions in Cation Exchanger:H2-R+Ca(HCO3)2→Ca-R+2H2O+2CO2\text{H}_2\text{-R} + \text{Ca(HCO}_3)_2 \rightarrow \text{Ca-R} + 2\text{H}_2\text{O} + 2\text{CO}_2H2-R+Mg(HCO3)2→Mg-R+2H2O+2CO2\text{H}_2\text{-R} + \text{Mg(HCO}_3)_2 \rightarrow \text{Mg-R} + 2\text{H}_2\text{O} + 2\text{CO}_2H2-R+CaSO4→Ca-R+H2SO4\text{H}_2\text{-R} + \text{CaSO}_4 \rightarrow \text{Ca-R} + \text{H}_2\text{SO}_4H2-R+MgSO4→Mg-R+H2SO4\text{H}_2\text{-R} + \text{MgSO}_4 \rightarrow \text{Mg-R} + \text{H}_2\text{SO}_4H2-R+CaCl2→Ca-R+2HCl\text{H}_2\text{-R} + \text{CaCl}_2 \rightarrow \text{Ca-R} + 2\text{HCl}H2-R+MgCl2→Mg-R+2HCl\text{H}_2\text{-R} + \text{MgCl}_2 \rightarrow \text{Mg-R} + 2\text{HCl}H2-R+2NaCl→Na2-R+2HCl\text{H}_2\text{-R} + 2\text{NaCl} \rightarrow \text{Na}_2\text{-R} + 2\text{HCl}
  • Anion Exchange Resins (R′-OH−\text{R}'\text{-OH}^-):

    • Styrene-divinylbenzene or amine-formaldehyde copolymers containing basic functional groups (amino, quaternary ammonium, or tertiary sulphonium).
    • Commercial examples: Amberlite 400, Dowex-3.
    • Reactions in Anion Exchanger:R′-(OH)2+H2SO4→R′-SO4+2H2O\text{R}'\text{-(OH)}_2 + \text{H}_2\text{SO}_4 \rightarrow \text{R}'\text{-SO}_4 + 2\text{H}_2\text{O}R′-(OH)2+2HCl→R′-Cl2+2H2O\text{R}'\text{-(OH)}_2 + 2\text{HCl} \rightarrow \text{R}'\text{-Cl}_2 + 2\text{H}_2\text{O}

Deionization and Ion Exchange Process Equipment

  • Degasifier Step:

    • Water exiting exchangers is passed into a heated degasifier connected to a vacuum pump to strip dissolved gases like CO2\text{CO}_2.
    • Residual total hardness is below 2 ppm2\,\text{ppm}, making it ideal for high-pressure boiler feed water.
  • Regeneration of Exhausted Resins:

    • Cation Exchanger: Regenerated by passing dilute acid solution (HCl\text{HCl} or H2SO4\text{H}_2\text{SO}_4):     (Ca/Mg/Na2)-R+H2SO4→H2-R+(Ca/Mg/Na2)SO4(\text{Ca/Mg/Na}_2)\text{-R} + \text{H}_2\text{SO}_4 \rightarrow \text{H}_2\text{-R} + (\text{Ca/Mg/Na}_2)\text{SO}_4
    • Anion Exchanger: Regenerated by passing dilute caustic soda (NaOH\text{NaOH}) or soda ash (Na2CO3\text{Na}_2\text{CO}_3):     R′-SO4+2NaOH→R′-(OH)2+Na2SO4\text{R}'\text{-SO}_4 + 2\text{NaOH} \rightarrow \text{R}'\text{-(OH)}_2 + \text{Na}_2\text{SO}_4
  • Advantages of Ion Exchange Process:

    • Suitable for highly acidic or alkaline waters.
    • Soft water is completely free of sodium ions (Na+\text{Na}^+).
    • Removes all cations and anions except H+\text{H}^+ and OH−\text{OH}^-.
    • Residual hardness is extremely low (∼2 ppm\sim 2\,\text{ppm}).
  • Disadvantages of Ion Exchange Process:

    • Equipment and resin costs are high.
    • Turbid water severely decreases process efficiency by clogging resin pores.

Municipal Water Treatment and Potable Water Supply

Components of the water supply system

Potable Water Treatment

  • Core Unit Operations in Municipal Water Supply:
    1. Screening: Removes floating debris, leaves, branches, and rags using coarse screens, fine bar screens, and comminutors (grinders).
    2. Pre-aeration / Aeration: Air agitation to reduce BOD, remove taste/odour-causing volatile organics, stripped gases (H2S\text{H}_2\text{S}), and oxidize dissolved iron/manganese.
    3. Pre-sedimentation: Uses sand traps and cyclone degritters to remove grit, sand, and gravel by gravity or centrifugal force.
    4. Coagulation and Flocculation:
    • Aluminium Sulphate (Alum, Al2(SO4)3\text{Al}_2(\text{SO}_4)_3): Hydrolyzes to form gelatinous Al(OH)3\text{Al(OH)}_3 flocs with large surface areas that adsorb and entrain colloidal impurities:        Al2(SO4)3+6H2O→2Al(OH)3+3H2SO4\text{Al}_2(\text{SO}_4)_3 + 6\text{H}_2\text{O} \rightarrow 2\text{Al(OH)}_3 + 3\text{H}_2\text{SO}_4
    • In natural alkaline waters:        Al2(SO4)3+3Ca(HCO3)2→2Al(OH)3+3CaSO4+6CO2\text{Al}_2(\text{SO}_4)_3 + 3\text{Ca(HCO}_3)_2 \rightarrow 2\text{Al(OH)}_3 + 3\text{CaSO}_4 + 6\text{CO}_2
    • In low-alkalinity waters (adding soda ash):        Al2(SO4)3+3Na2CO3+3H2O→2Al(OH)3+3Na2SO4+3CO2\text{Al}_2(\text{SO}_4)_3 + 3\text{Na}_2\text{CO}_3 + 3\text{H}_2\text{O} \rightarrow 2\text{Al(OH)}_3 + 3\text{Na}_2\text{SO}_4 + 3\text{CO}_2
    • Sodium Aluminate (NaAlO2\text{NaAlO}_2): Used for acidic waters:        NaAlO2+2H2O→NaOH+Al(OH)3\text{NaAlO}_2 + 2\text{H}_2\text{O} \rightarrow \text{NaOH} + \text{Al(OH)}_3Al2(SO4)3+6NaAlO2+12H2O→8Al(OH)3+3Na2SO4\text{Al}_2(\text{SO}_4)_3 + 6\text{NaAlO}_2 + 12\text{H}_2\text{O} \rightarrow 8\text{Al(OH)}_3 + 3\text{Na}_2\text{SO}_4
    1. Sedimentation: Gravity settling of coagulated flocs in clarifiers.
    2. Filtration: Passing water through sand filter beds (fine sand, coarse sand, fine gravel, coarse gravel) to eliminate fine suspended particles.

Coagulation, flocculation, and sedimentation units

Municipal water treatment with coagulation, settling and filtration tanks

  • Disinfection Methods:

    • Factors influencing disinfectant efficiency: contact time, disinfectant concentration, microorganism type/concentration, temperature, pH, and ionic strength.
    • Chlorination:
    • Uses gaseous chlorine (Cl2\text{Cl}_2) or bleaching powder (CaOCl2\text{CaOCl}_2) with a contact time of ∼30 minutes\sim 30\,\text{minutes}:       CaOCl2+H2O→Ca(OH)2+Cl2\text{CaOCl}_2 + \text{H}_2\text{O} \rightarrow \text{Ca(OH)}_2 + \text{Cl}_2Cl2+H2O→HOCl+HCl\text{Cl}_2 + \text{H}_2\text{O} \rightarrow \text{HOCl} + \text{HCl}HOCl (Hypochlorous Acid)→[O] (Nascent Oxygen)+HCl\text{HOCl (Hypochlorous Acid)} \rightarrow [\text{O}]\text{ (Nascent Oxygen)} + \text{HCl}
    • Nascent oxygen destroys bacteria via oxidation.
    • Cell Membrane Penetration Mechanism: Neutral HOCl\text{HOCl} molecules readily cross the cell wall, whereas negatively charged hypochlorite ions (OCl−\text{OCl}^-) are repelled by the cell membrane.
    • Chloramine Process (Ammonia-Chlorine Treatment):
    • Addition of ammonia with chlorine prevents phenolic taste issues and provides long-lasting residual disinfection:       Cl2+NH3→NH2Cl (Monochloramine)+HCl\text{Cl}_2 + \text{NH}_3 \rightarrow \text{NH}_2\text{Cl}\text{ (Monochloramine)} + \text{HCl}2Cl2+NH3→NHCl2 (Dichloramine)+2HCl2\text{Cl}_2 + \text{NH}_3 \rightarrow \text{NHCl}_2\text{ (Dichloramine)} + 2\text{HCl}
    • Break Point Chlorination:
    • Controlled process adding sufficient chlorine to oxidize all organic matter, destroy pathogens, and react with ammonia, leaving a slight free residual.
    • Four Curve Stages:
      • Stage I: Lower doses oxidized reducing compounds; no residual chlorine.
      • Stage II: Formation of chloramines and chloro-organic compounds; residual chlorine increases to peak.
      • Stage III: Oxidation of chloramines; residual chlorine drops to a minimum at the Break Point (water is now potable).
      • Stage IV: Post-break point; added chlorine yields equal free available residual chlorine.
    • Dechlorination: Removal of excess residual chlorine using activated charcoal, sulphur dioxide (SO2\text{SO}_2), or sodium sulphite (Na2SO3\text{Na}_2\text{SO}_3):     SO2+Cl2+2H2O→H2SO4+2HCl\text{SO}_2 + \text{Cl}_2 + 2\text{H}_2\text{O} \rightarrow \text{H}_2\text{SO}_4 + 2\text{HCl}Na2SO3+Cl2+H2O→Na2SO4+2HCl\text{Na}_2\text{SO}_3 + \text{Cl}_2 + \text{H}_2\text{O} \rightarrow \text{Na}_2\text{SO}_4 + 2\text{HCl}
    • Ozonisation:
    • Generated by silent electric discharge through cold, dry oxygen:       3O2→silent electric discharge2O33\text{O}_2 \xrightarrow{\text{silent electric discharge}} 2\text{O}_3O3→O2+[O]\text{O}_3 \rightarrow \text{O}_2 + [\text{O}]
    • Dosage: 2−3 ppm2 - 3\,\text{ppm} with 10−15 minutes10 - 15\,\text{minutes} contact time.
    • Advantages: Sterilizes, bleaches, deodorizes, improves taste; excess decomposes back to harmless O2\text{O}_2
    • Disadvantages: Highly expensive and corrosive to cast iron, stainless steel, copper, and rubber.
  • Summary Table of Principal Contaminants and Treatment Units:

ContaminantsCorresponding Treatment Unit
Taste & odour-causing volatile organics, gases, Fe\text{Fe}, Mn\text{Mn}Aeration
Microorganisms, taste/odour/colour compoundsPre-oxidation (Pre-chlorination)
Colloidal particlesCoagulation and Flocculation
Suspended solids / flocsSedimentation
Fine suspended particlesFiltration
PathogensDisinfection

Desalination by Reverse Osmosis

  • Osmosis vs. Reverse Osmosis:
    • Osmosis: Spontaneous flow of solvent molecules through a semi-permeable membrane from a dilute solution to a concentrated solution driven by osmotic pressure.
    • Reverse Osmosis (RO): Applying an external pressure exceeding the osmotic pressure onto the concentrated saline solution squeezes pure water molecules backwards through the semi-permeable membrane, separating pure water from contaminants.
    • Also known as super-filtration or hyper-filtration.

Normal osmosis vs Reverse osmosis

  • Membrane Materials: Polymethacrylate, polyamide polymers, or cellulose acetate.
  • Advantages: Removes heavy metals (Pb\text{Pb}), hardness cations (Ca2+\text{Ca}^{2+}, Mg2+\text{Mg}^{2+}), alkali metals (Na+\text{Na}^+, K+\text{K}^+), anions (Cl−\text{Cl}^-, NO3−\text{NO}_3^-, F−\text{F}^-, SO42−\text{SO}_4^{2-}), dissolved organics, and pathogens.
  • Disadvantages: High volume waste output; can require up to 90 L90\,\text{L} of feed water to recover 5 L5\,\text{L} of usable purified water.

Wastewater and Sewage Treatment

  • Four Primary Steps of Sewage Treatment:

    1. Pretreatment (Preliminary Treatment): Physical removal and size reduction of large floating objects (stones, twigs, rags, plastics).
    • Five Sub-steps: Screening (coarse/fine screens, comminutor), Presedimentation (sand traps, cyclone degritting), Microstraining (rotating stainless steel mesh drums to remove algae/diatoms), Pre-aeration (air agitation to skim grease/oil and reduce BOD), and Prechlorination (prevents septic decay and controls odour).
    1. Primary Treatment (Physico-Chemical):
    • Water retained in primary clarifiers (10−15 ft10 - 15\,\text{ft} deep) for ∼3 hours\sim 3\,\text{hours} detention time with coagulants.
    • Removal Efficiency: Removes 80−90%80 - 90\% of Total Dissolved Solids, 65%65\% of Suspended Solids, and up to 45%45\% of BOD substances.
    1. Secondary Treatment (Biological Treatment):
    • Microbially degrades biological content derived from food, detergent, and human waste.
    • Requires adequate oxygen supply and microbial population.
    • Two Primary Methods: Trickling Filter Process and Activated Sludge Process.
    1. Tertiary Treatment (Advanced Treatment): Advanced polishing for specific nutrient removal and final sterilization.
  • Trickling Filter Process (Fixed-Film Biological Process):

    • Wastewater is sprayed via rotating distributors over a bed media (rocks/plastic) coated in a biological biofilm.
    • Aerobic microbes in the biofilm oxidize organic pollutants as liquid trickles downward.

Design of trickling filter unit

  • Activated Sludge Process (Suspended-Growth Biological Process):
    • Wastewater is continuously mixed with active microbial biomass (activated sludge) in an aeration tank supplied with compressed air.
    • Microbes convert dissolved organics into CO2\text{CO}_2, H2O\text{H}_2\text{O}, and cell mass, followed by settling in a secondary clarifier.

Conventional purification scheme vs membrane bioreactor scheme

  • Comparison Between Activated Sludge and Trickling Filter:
AttributeActivated Sludge ProcessTrickling Filter Process
Process TypeBiologicalBiological
Flow DesignContinuous flowIntermittent flow
Microbial MediaSuspended growthFixed film (biofilm)
Organic Load RemovalHighMedium
Nutrient RemovalPossible with process modificationsInefficient for nutrient removal
Sludge ProductionHigherLower
Effluent QualityHigherLower
  • Tertiary Treatment Processes:
    • Solids Removal: Removes fine residual suspended solids (0.1−100 μm0.1 - 100\,\mu\text{m} at 20−40 mg/L20 - 40\,\text{mg/L}) using sand filters, micro-screening, or diatomaceous earth filters.
    • Dissolved Solids Removal: Adsorption via porous activated carbon removes pesticides, herbicides, tannins, lignins, toxic trace metals, and color/odour compounds.
    • Biological Nitrogen Removal & Biological Phosphorus Removal: Prevents downstream eutrophication.
    • Final Disinfection: Selective destruction/inactivation of pathogenic organisms (controlling water-borne diseases like typhoid, cholera, and dysentery).