Pump Affinity Laws Cheat Sheet - flow, head and power vs speed (linear, squared, cubed)
What You Need to Know
Pump affinity laws let you predict how a rotodynamic pump (centrifugal/mixed/axial) performance shifts when you change rotational speed (typically via a VFD) while keeping the same pump/impeller diameter and same fluid.
They’re high-yield because exam problems often give a pump operating point or curve at and ask for flow , head , and power at a new speed .
The core idea (the “linear, squared, cubed” rule)
For the same pump geometry (same impeller diameter ) operating in the same similarity regime, approximately:
So changing speed by a factor changes:
Critical reminder: These are affinity (similarity) approximations for rotodynamic pumps. They do not apply the same way to positive displacement pumps.
When you can trust them most
- Same pump (same impeller diameter, same volute/diffuser)
- Same fluid and similar viscosity effects (i.e., Reynolds number not drastically different)
- Moderate speed changes (small to moderate deviations from the tested speed)
- Near the normal operating region (not deep into shutoff or runout extremes)
Step-by-Step Breakdown
Use this method whenever you’re given a baseline operating point or curve at and asked to estimate performance at .
1) Define the speed ratio
Compute:
2) Scale flow, head, and power
Apply:
3) If you’re given a pump curve (not just one point)
Affinity laws scale the entire curve point-by-point:
- Every flow value scales by
- Every head value scales by
- Every power value scales by
Practically: pick a few points on the original curve, scale them, sketch the new curve.
4) If the question is “what speed do I need?”
Rearrange by the variable you’re targeting:
- Target flow from :
- Target head from :
- Target power from :
5) Decision point: operating point vs “new curve”
Many exam questions hide this subtlety:
- If you’re asked “At the same operating point” (same system resistance), you may need to find the new intersection between the scaled pump curve and the system curve.
- If you’re asked “How do Q/H/P scale for the pump”, you can scale the pump performance directly.
System curve refresher (common in affinity-law problems):
Speed change moves the pump curve, not the system curve.
Mini worked method (annotated)
Given: , , , , .
1) Ratio:
2) Scale:
Key Formulas, Rules & Facts
Speed-based affinity laws (same impeller diameter)
| Quantity | Relationship (same ) | Ratio form | Notes / when it’s used |
|---|---|---|---|
| Flow | Best first estimate for VFD speed change | ||
| Head | Head is energy per unit weight (not pressure) | ||
| Power | Big exam takeaway: power drops fast when speed drops |
Derived “solve-for-speed” versions
| Target | Formula | Use when |
|---|---|---|
| for desired | You want a certain flow (approx.) | |
| for desired | You need a certain head (approx.) | |
| for desired | Motor limit / energy comparison |
Head vs pressure (don’t mix these)
- Pump curves often use head .
- Pressure rise relates to head by:
Same head with different fluids means different pressure rise.
Efficiency assumption (what exams often imply)
The simple scaling is most consistent when **pump efficiency** is treated as approximately constant between the two operating points.
Hydraulic power is:
Shaft power is:
Using the affinity scalings, , hence (if doesn’t change much).
Warning: Efficiency does change with operating point. If a problem provides efficiency at the new condition, use it.
Common “extra” affinity-type relation you may see: NPSH
Many practical references approximate required NPSH scaling with speed roughly as:
So:
Use this only if the course/material explicitly supports it.
Edge-case note: diameter-based affinity laws (often mixed into speed questions)
Even though your focus is speed, exam setters sometimes throw in diameter trimming.
For geometrically similar impellers at constant speed:
Don’t accidentally apply -laws when the question is purely VFD speed change.
Examples & Applications
Example 1: Quick VFD change at the same pump point (direct scaling)
A pump delivers at and draws at . Estimate performance at .
Compute ratio:
Scale:
Key insight: a speed reduction cuts power by about .
Example 2: Find the needed speed for a target head
At , the pump produces at a certain operating condition. What speed gives (assume similarity)?
Use head scaling:
Compute:
Key insight: head goes with , so head increases quickly with speed.
Example 3: Motor power check when speeding up
A pump draws at . If you increase speed to , estimate the new power (assume similar efficiency) and check against a motor.
Ratio:
Power scaling:
Conclusion: a motor would likely overload.
Key insight: speed increases are dangerous for motor sizing because .
Example 4: Intersection with a system curve (what changes physically)
You have a system curve:
with in and in .
A pump curve at is approximately:
If speed is reduced to , estimate the scaled pump curve and the new operating point.
1) Scale pump curve: for any original point , the new point is:
To express as a function of , note .
So:
This simplifies numerically to:
2) New operating point solves :
Then head:
Key insight: the actual after speed change depends on the system curve intersection, not just direct scaling of a single original operating point.
Common Mistakes & Traps
Using affinity laws on positive displacement pumps
- What goes wrong: you assume and also treat head and power like centrifugal behavior.
- Why wrong: PD pumps have near-constant displacement per rev, but pressure/head is set mainly by the system and relief valves; power scales differently.
- Fix: apply affinity laws primarily to rotodynamic pumps unless explicitly told otherwise.
Mixing up head and pressure
- What goes wrong: you scale as without considering density.
- Why wrong: affinity law is for head ; pressure is .
- Fix: scale with , then convert to pressure using the given .
Forgetting the cube on power
- What goes wrong: you scale power linearly or quadratically.
- Why wrong: for similar operation with roughly constant efficiency, .
- Fix: memorize the pattern: linear, squared, cubed.
Assuming the operating point scales directly even when the system curve matters
- What goes wrong: you compute as if the pump is “forced” to the scaled flow.
- Why wrong: the pump delivers where pump curve intersects system curve.
- Fix: if the system is mentioned (static head, friction, ), scale the pump curve and re-intersect.
Large extrapolations far from the tested region
- What goes wrong: you apply affinity laws from a single tested point to extreme speeds.
- Why wrong: efficiency shifts, hydraulic losses and recirculation increase, cavitation margin changes.
- Fix: treat affinity results as estimates; be cautious beyond moderate speed changes.
Not checking cavitation / NPSH when increasing speed
- What goes wrong: you increase to hit flow/head, ignore NPSH.
- Why wrong: NPSH required commonly increases roughly with , so cavitation risk rises quickly.
- Fix: when speed goes up, explicitly consider NPSH if the problem context includes suction conditions.
Unit sloppiness (rpm vs rps, volumetric flow units)
- What goes wrong: using in rpm in one place and rps in another, or mixing with .
- Why wrong: ratios are unitless, but only if consistent.
- Fix: compute using the same units; keep units consistent.
Assuming efficiency is constant when the question gives efficiency data
- What goes wrong: you use even though changes.
- Why wrong: shaft power depends on .
- Fix: if is given, use .
Memory Aids & Quick Tricks
| Trick / mnemonic | What it helps you remember | When to use it |
|---|---|---|
| “L-S-C” | Flow Linear, Head Squared, Power Cubed with speed | Fast recall under exam time pressure |
| “” | If then scale by | Any VFD/speed-change question |
| Back-solve speed | , , | “What rpm do I need?” questions |
| Motor overload intuition | A small speed increase causes a big power increase because of | Sanity-checking results |
| System curve flag | If you see or , you must re-intersect curves | Operating point problems |
Quick Review Checklist
- You’re working with a rotodynamic pump (centrifugal/mixed/axial), not a PD pump.
- Compute the speed ratio:
- Scale with speed:
- If asked for rpm to hit a target, invert the appropriate law (linear, square root, cube root).
- If a system curve is present, scale the pump curve and find the new intersection.
- Convert head to pressure only after scaling:
- Be cautious with large speed changes; efficiency and NPSH can break simple scaling.
You’ve got this: memorize and you can knock out most affinity-law problems in minutes.