ChE 261 Industrial Pollution Control: Introduction to Aerosols, Gas Laws, and the Philippine Clean Air Act Study Notes

Definition and Physical Characteristics of Aerosols

  • Aerosol Definition: An aerosol is a dispersoid consisting of liquid and/or solid particles that are suspended in a gaseous dispersion medium.

  • Stability: Such mixtures exhibit stability to separation processes over a relevant time period.

  • Size Range: Aerosols consist of particles ranging in size from approximately 0.001 mm0.001\,mm to 100 mm100\,mm.

  • Size Limits Reasoning:

    • Lower Limit: Particles smaller than this scale behave similarly to gas molecules.

    • Upper Limit: Separation processes readily remove larger particles from their gaseous dispersion medium due to gravity or other physical forces.

Gas Concentration Units and the Ideal Gas Law

  • Volume per Unit Volume Basis: Often expressed as parts per million by volume (ppmv).

    • Equation: ppmv=VaVT×106\text{ppmv} = \frac{V_a}{V_T} \times 10^6

    • VaV_a: Volume of gaseous component aa

    • VTV_T: Total volume of the gas

  • Mass per Unit Volume Basis: Concentrations are also described by the mass (mam_a) of a component per unit volume of the gas sample.

  • Ideal Gas Law Application: Used to relate pressure, volume, and temperature to moles.

    • Equation: PTVa=naRTTP_T V_a = n_a R T_T

    • PTP_T: Total pressure

    • nan_a: Moles of component aa

    • RR: Ideal gas law constant (0.0821 atm⋅L/g-mole⋅K0.0821\,atm \cdot L / g\text{-mole} \cdot K)

    • TTT_T: Temperature of the gas

  • Conversion Formulas:

    • Moles can be calculated as: na=maMWan_a = \frac{m_a}{MW_a}, where MWaMW_a is the molecular weight.

    • Mass of component aa (mam_a): ma=VaPTMWaRTTm_a = \frac{V_a P_T MW_a}{R T_T}

    • Concentration in mass per volume: maVT=ppmv106×PTMWaRTT\frac{m_a}{V_T} = \frac{\text{ppmv}}{10^6} \times \frac{P_T MW_a}{R T_T}

  • Molecular Density: Concentrations can be described by the number of molecules (NaN_a) per unit volume (VTV_T).

    • Na=na×NAVN_a = n_a \times N_{AV}

    • NAVN_{AV} (Avogadro's Number): 6.022×1023 molecules/g-mole6.022 \times 10^{23}\,\text{molecules/g-mole}

Ideal Gas Law Mathematical Relations and Mole Fractions

  • Pressure and Moles Relationship: PaPT=nanT\frac{P_a}{P_T} = \frac{n_a}{n_T}

  • Volume and Moles Relationship: VaVT=nanT\frac{V_a}{V_T} = \frac{n_a}{n_T}

  • Equivalence: PaPT=nanT=VaVT\frac{P_a}{P_T} = \frac{n_a}{n_T} = \frac{V_a}{V_T}

  • Mole Fraction (yay_a): The ratio of moles of a component to the total moles.

    • Equation for a two-component gas (nT=na+nbn_T = n_a + n_b): ya=nanT=nana+nby_a = \frac{n_a}{n_T} = \frac{n_a}{n_a + n_b}

  • Mole Ratio (YaY_a): Ratio of moles of component aa to moles of the other component(s).

    • Equation: Ya=nanb=nanT−naY_a = \frac{n_a}{n_b} = \frac{n_a}{n_T - n_a}

    • Conversion: ya=Ya1+Yay_a = \frac{Y_a}{1 + Y_a} and Ya=ya1−yaY_a = \frac{y_a}{1 - y_a}

  • Changes in Condition: For a gas of constant mass and composition moving from Condition 1 to Condition 2:

    • Equation: P1V1n1RT1=P2V2n2RT2\frac{P_1 V_1}{n_1 R T_1} = \frac{P_2 V_2}{n_2 R T_2}

    • If n1=n2n_1 = n_2, then: V2=V1(P1P2)(T2T1)V_2 = V_1 \left( \frac{P_1}{P_2} \right) \left( \frac{T_2}{T_1} \right)

  • Mean Molecular Weight (MWMW): The average molecular weight of a mixture.

    • Equation: MW=∑MWi×(ninT)MW = \sum MW_i \times \left( \frac{n_i}{n_T} \right)

Gas Stream Flow Relationships

  • Mass Feed Rate (m˙\dot{m}): Related to volumetric flow rate (QgQ_g) and mass density (ρg\rho_g).

    • Equation: m˙=Qgρg\dot{m} = Q_g \rho_g

    • Density: ρg=P(MW)RT\rho_g = \frac{P (MW)}{RT}

  • Flow Rate Changes between Conditions:

    • Qg1ρg1=Qg2ρg2Q_{g1} \rho_{g1} = Q_{g2} \rho_{g2}

    • If MW1=MW2MW_1 = MW_2, then: Qg2=Qg1(P1P2)(T2T1)Q_{g2} = Q_{g1} \left( \frac{P_1}{P_2} \right) \left( \frac{T_2}{T_1} \right)

Standard Conditions and Corrective Factors

  • Standard Conditions (SC): Standard temperature and pressure are essential for industrial streams because concentrations vary with temperature (TT), pressure (PP), water vapor (H2O(g)H_2O_{(g)}), and oxygen/carbon dioxide levels.

    • Fixed pressure: Ps=1 atmP_s = 1\,atm

    • Varied standards for Temperature (TsT_s): 0oC0^oC, 20oC20^oC, 32oF32^oF, or 77oF77^oF depending on the frame of reference.

  • Moist to Dry Correction: To correct the concentration of a component from actual moist conditions (AA) to dry conditions (BB\/DD):

    • Equation: maVT,D=maVT,A×(11−yH2O(g))\frac{m_a}{V_{T,D}} = \frac{m_a}{V_{T,A}} \times \left( \frac{1}{1 - y_{H_2O(g)}} \right)

  • Correction to Standard Emissions:

    • 12% Carbon Dioxide (CO2CO_2): [maVT,D,12%CO2]=[maVT,D]×12%X% measured CO2\left[ \frac{m_a}{V_{T,D, 12\% CO_2}} \right] = \left[ \frac{m_a}{V_{T,D}} \right] \times \frac{12\%}{\text{X}\% \text{ measured } CO_2}

    • 7% Oxygen (O2O_2): [maVT,D,7%O2]=[maVT,D]×21%−7%21%−X% measured O2=[maVT,D]×14%21%−X% measured O2\left[ \frac{m_a}{V_{T,D, 7\% O_2}} \right] = \left[ \frac{m_a}{V_{T,D}} \right] \times \frac{21\% - 7\%}{21\% - \text{X}\% \text{ measured } O_2} = \left[ \frac{m_a}{V_{T,D}} \right] \times \frac{14\%}{21\% - \text{X}\% \text{ measured } O_2}

Examples of Mass Concentration Calculations

  • Calculating SO2SO_2 concentration:

    • Given: 1 ppmv1\,ppmv at 298 K298\,K and 1 atm1\,atm.

    • Atomic weights: S=32.06S = 32.06, O=16.00O = 16.00. MWSO2=64.06 g/g-moleMW_{SO_2} = 64.06\,g/g\text{-mole}.

    • Concentration calculation: 1106×1 atm×64.06 g/g-mole0.0821 atm⋅L/g-mole⋅K×298 K=2.62×10−6 g/L\frac{1}{10^6} \times \frac{1\,atm \times 64.06\,g/g\text{-mole}}{0.0821\,atm \cdot L / g\text{-mole} \cdot K \times 298\,K} = 2.62 \times 10^{-6}\,g/L

    • Convert to mg/m3mg/m^3: 2.62×10−6 g/L×103 mg/g×103 L/m3=2,618 mg/m32.62 \times 10^{-6}\,g/L \times 10^3\,mg/g \times 10^3\,L/m^3 = 2,618\,mg/m^3.

  • Gas Stream Point Source Conversion (NO to NO2NO_2):

    • Source conditions: 140oC140^oC, 1.01 atm1.01\,atm, 200 ppmv NO200\,ppmv\,NO, and 10.9% H2O(g)10.9\%\,H_2O_{(g)}.

    • Goal: Calculate mass concentration of NO2NO_2 at Dry Standard Conditions (Ts=25oCT_s = 25^oC).

    • Actual condition mass density (NONO): 178.94 mg/m3178.94\,mg/m^3

    • Corrected to Dry Standard Condition: 178.94×(11.01)×(273+140273+25)×(11−0.109)=275.58 mg NO/m3178.94 \times \left( \frac{1}{1.01} \right) \times \left( \frac{273+140}{273+25} \right) \times \left( \frac{1}{1-0.109} \right) = 275.58\,mg\,NO/m^3

    • Equivalent mass as NO2NO_2: 275.58×(MWNO2MWNO)=275.58×4630=423 mg NO2/m3275.58 \times \left( \frac{MW_{NO_2}}{MW_{NO}} \right) = 275.58 \times \frac{46}{30} = 423\,mg\,NO_2/m^3.

  • Particulate Matter (PM) Concentration:

    • Actual state: 3 g/m33\,g/m^3.

    • Correction to Dry Standard Condition: 3×(11.01)×(413298)×(11−0.109)=4.62 g PM/m33 \times \left( \frac{1}{1.01} \right) \times \left( \frac{413}{298} \right) \times \left( \frac{1}{1-0.109} \right) = 4.62\,g\,PM/m^3.

Methods for Studying Air Contaminant Health Effects

  • Epidemiological Studies of Human Populations:

    • Focuses on effects that have already occurred in the real world.

    • Primarily monitors low-concentration contaminants over extended periods.

    • Challenges include the "co-existence" of multiple contaminants making it hard to isolate variables.

  • Clinical Studies (Humans):

    • Controlled laboratory exposure of humans to known contaminants.

    • Allows for specific measurements of responses like exercise tolerance and sensitivity.

    • Experiments are intensive and of short duration (before, during, and after exposure).

  • Laboratory Animal Experiments:

    • Subject animals to controlled conditions.

    • Offers high flexibility in concentration and duration.

    • Limitation: Difficulty in extrapolating results from animals to humans and from high-dose/short-term exposure to low-dose/long-term effects.

The Philippine Clean Air Act (Republic Act No. 8749)

  • Legislation: Enacted in 1999 (R.A. 8749). Implementing Rules and Regulations (IRR) found in DENR DAO 2000-81.

  • Key Policy Objectives:

    • Protect public health and welfare.

    • Prevent and control pollution from all sources.

    • Promote cleaner production and sustainable development.

    • Encourage public participation and transparency.

  • Definitions:

    • Air Pollutant: Any substance that alters air quality.

    • Stationary Source: Fixed installations emitting pollutants.

    • Mobile Source: Vehicles and transport equipment.

    • Ambient Air Quality: The quality of air in the environment surrounding us.

    • BACT: Best Available Control Technology.

  • Institutional Framework:

    • National Air Quality Management Commission (NAQMC).

    • Department of Environment and National Resources (DENR) – Environmental Management Bureau (EMB).

    • Local Government Units (LGUs).

    • Establishment of Air Quality Management Areas (Airsheds) and Ambient Monitoring Stations.

Air Quality Standards and Emission Limits

  • Ambient Air Quality Guidelines (PH Standards in μg/m3\mu g/m^3):

    • TSP (Total Suspended Particulates): ∼90\sim 90 (Annual)

    • PM10: ∼50\sim 50 (Annual)

    • SO2SO_2: ∼250\sim 250 (24 hr24\,hr)

    • NO2NO_2: ∼100\sim 100 (Annual)

    • COCO: ∼10,000\sim 10,000 (8 hr8\,hr) or approximately ∼9 ppm\sim 9\,ppm

    • O3O_3: ∼100\sim 100 (8 hr8\,hr)

    • Lead (PbPb): ∼1.5\sim 1.5 (Annual)

  • Emission Standards for Stationary Sources (mg/Ncm):

    • PM: 150150 (Cement plants); 200200 (Other sources).

    • NOxNO_x (as NO2NO_2): New oil-fired (500500); New coal-fired (1,0001,000); Existing sources (1,5001,500).

    • SOxSO_x (as SO2SO_2): New fuel-burning sources (700700).

    • COCO: 500500.

  • Toxic Pollutant Limits (mg/Ncm):

    • Lead (PbPb): 1010

    • Mercury (HgHg): 55

    • Cadmium (CdCd): 1010

    • Nickel (NiNi): ∼50\sim 50

    • Copper (CuCu): ∼50\sim 50

  • Difference: Ambient vs. Emission Standards:

    • Ambient: Measured in the general environment; protects public exposure; bases for airshed planning.

    • Emission: Measured at the stack or exhaust; technology-based; enforced through permits (Authority to Construct, Permit to Operate).

Carbon Monoxide (CO): Health and Environmental Effects

  • General Characteristics: Minor participant in photochemical smog; concentration is declining due to vehicle emission controls; sinks include fungi and conversion to CO2CO_2; no effect on plants/materials.

  • Physiological Action: Oxygen displacer.

  • Carboxyhemoglobin (COHBCOHB) Formation:

    • COHBO2HB=240×PCOPO2\frac{COHB}{O_2HB} = 240 \times \frac{P_{CO}}{P_{O_2}}

  • Saturation Example: If air (21% O2O_2 or 210,000 ppm210,000\,ppm) contains 100 ppm CO100\,ppm\,CO, the recovery ratio is: 240×100210,000=0.11240 \times \frac{100}{210,000} = 0.11.

  • Health Effect Thresholds (COHBCOHB levels):

    • < 1%: No apparent effects.

    • 1 - 2%: Evidence of behavioral performance effects.

    • \u2265 2.3%: Reduced exercise performance in healthy people.

    • 3 - 6%: Increased chest pain in heart disease patients.

    • > 5%: Visual perception, audition, and motor impairment.

    • > 10%: Headaches, dizziness, nausea, death.

  • Secondary Effects: interferes with oxygen release by remaining Oxyhemoglobin (O2HBO_2HB).

  • Smoking Impact:

    • Cigarette smoke concentration: 400−450 ppm CO400 - 450\,ppm\,CO.

    • Non-smokers: 2%2\% saturation.

    • 1 pack/day: 6.3%6.3\% saturation.

    • 2 packs/day: 7.7%7.7\% saturation.

Sulfur Oxides (SOx) and Nitrogen Dioxide (NO2)

  • Sulfur Dioxide (SO2SO_2):

    • Pungent odor threshold: >3 ppm> 3\,ppm.

    • Environmental conversion: SO3+H2O→H2SO4SO_3 + H_2O \rightarrow H_2SO_4.

    • Secondary Aerosols: Sunlit mixtures of HC, NOxNO_x, and SOxSO_x form sulfuric acid droplets that scatter light and cause haze.

    • Primary Standards: 80 μg/m380\,\mu g/m^3 (1 year); 365 μg/m3365\,\mu g/m^3 (24 hr).

    • Ecological Effects: Tree damage starts around 785 μg/m3785\,\mu g/m^3.

  • Nitrogen Dioxide (NO2NO_2):

    • Standard: 100 μg/m3100\,\mu g/m^3 (1 year).

    • Impacts: Acute/chronic respiratory disease; forms photochemical oxidants.

    • Pediatric effects: Increased disease incidence at 150−188 μg/m3150 - 188\,\mu g/m^3 over several years.

Other Pollutants and Global Issues

  • Lead (PbPb):

    • Standard: 1.5 μg/m31.5\,\mu g/m^3 (3-month average).

    • Health: Impairs porphyrin metabolism (hemoglobin synthesis), learning disabilities, and seizures.

  • Ozone (O3O_3):

    • Standard: 235 μg/m3235\,\mu g/m^3 (1 hr1\,hr).

    • Effects: Eye irritation; respiratory function impairment; vegetation damage at 98 μg/m398\,\mu g/m^3.

  • Particulate Matter (PM-10):

    • Standards: 50 μg/m350\,\mu g/m^3 (1 year); 150 μg/m3150\,\mu g/m^3 (24 hr).

    • Effects: Visibility reduced to ∼5 miles\sim 5\,miles at 150 μg/m3150\,\mu g/m^3; corrosion of steel/zinc at high concentrations.

  • Acid Rain: Market-based systems for SO2SO_2 reduction; performance standards for NOxNO_x.

  • Ozone Depletion Phase-out (Montreal Protocol):

    • Carbon tetrachloride/Methyl chloride: Phased out by 2000.

    • Methyl chloroform: Phased out by 2002.

    • CFC Production: Phased out by 2030.

    • Non-essential CFCs: Prohibited after November 1992.