Quantities and Units in Electronics Study Guide

Units of Measurement and the SI System

  • International Standards History: In the 19th century, measurement units were primarily for commerce. As technology advanced, a need for international standards arose. In 1875, representatives from 18 nations signed a treaty in France to establish international standards.

  • Le Système International d’Unités (SI): This is the modern, improved international system of units used in all engineering and scientific work.

  • Categories of SI Units: The system is composed of seven base units, two supplementary units, and various derived units.

  • SI Base Units (Table 1–1):

    • Length: Meter (mm)

    • Mass: Kilogram (kgkg)

    • Time: Second (ss)

    • Electric current: Ampere (AA)

    • Temperature: K

    • in (KK)

    • Luminous intensity: Candela (cdcd)

    • Amount of substance: Mole (molmol; added in 1971)

  • SI Supplementary Units (Table 1–2):

    • Plane angle: Radian (radrad)

    • Solid angle: Steradian (srsr)

  • Base Electrical Unit: The ampere (AA) is the fundamental unit for electrical current, abbreviated with the letter II for intensity. It is unique because it uses the base unit of time (second) in its definition.

  • Derived Units: These are units defined by combinations of base units. Examples include voltage, power, and magnetic flux.

    • Voltage Example: The derived unit for voltage is the volt (VV). In terms of base units, it is defined as m2⋅kg⋅s−3⋅A−1m^2 \cdot kg \cdot s^{-3} \cdot A^{-1}. This combination is cumbersome, so the volt is used for practicality.

  • Letter Symbols: Italic letters typically represent the quantity, while nonitalic (roman) letters represent the unit.

    • Example: Italic PP stands for power; nonitalic WW stands for watt.

    • Example: Italic VV stands for voltage; nonitalic VV stands for volt.

  • Common Electrical Quantities (Table 1–3):

    • Capacitance: CC; Unit: Farad (FF)

    • Charge: QQ; Unit: Coulomb (CC)

    • Conductance: GG; Unit: Siemens (SS)

    • Energy (work): WW; Unit: Joule (JJ)

    • Frequency: ff; Unit: Hertz (HzHz)

    • Impedance: ZZ; Unit: Ohm (Ω\Omega)

    • Inductance: LL; Unit: Henry (HH)

    • Power: PP; Unit: Watt (WW)

    • Reactance: XX; Unit: Ohm (Ω\Omega)

    • Resistance: RR; Unit: Ohm (Ω\Omega)

    • Voltage: VV; Unit: Volt (VV)

  • Magnetic Quantities and Derived Units (Table 1–4):

    • Magnetic field intensity: HH; Unit: Ampere-turns/meter (At/mAt/m)

    • Magnetic flux: ϕ\phi; Unit: Weber (WbWb)

    • Magnetic flux density: BB; Unit: Tesla (TT)

    • Magnetomotive force: FmF_m; Unit: Ampere-turn (AtAt)

    • Permeability: μ\mu; Unit: Webers/ampere-turn-meter (Wb/At⋅mWb/At \cdot m)

    • Reluctance: R\mathcal{R}; Unit: Ampere-turns/weber (At/WbAt/Wb)

  • Measurement Systems:

    • mks system: Based on meter, kilogram, and second. This is the basis for most SI derived units and is preferred for scientific work.

    • cgs system: An older metric system based on centimeter, gram, and second. Some units like the gauss (magnetic flux) are still in common use from this system, though mks is preferred.

Scientific Notation

  • Definition: A method of expressing quantities as a product of a number between 1 and 10 and a power of ten.

    • Example: 150,000=1.5×105150,000 = 1.5 \times 10^5

    • Example: 0.00022=2.2×10−40.00022 = 2.2 \times 10^{-4}

  • Powers of Ten (Table 1–5):

    • 106=1,000,00010^6 = 1,000,000

    • 103=1,00010^3 = 1,000

    • 100=110^0 = 1

    • 10−3=0.00110^{-3} = 0.001

    • 10−6=0.00000110^{-6} = 0.000001

  • Exponent: The number to which the base (10) is raised. It indicates how many places the decimal point is moved.

    • Positive exponent: Move the decimal to the right (104=1.0000.=10,00010^4 = 1.0000. = 10,000 ).

    • Negative exponent: Move the decimal to the left (10−4=.0001.=0.000110^{-4} = .0001. = 0.0001).

  • Calculations with Scientific Notation:

    • Addition: Express both numbers in the same power of ten, add the coefficients, and bring down the common power of ten.

    • Subtraction: Express both numbers in the same power of ten, subtract the coefficients, and bring down the common power of ten.

    • Multiplication: Multiply the coefficients and algebraically add the exponents (1012×10−6=1012+(−6)=10610^{12} \times 10^{-6} = 10^{12 + (-6)} = 10^6).

    • Division: Divide the coefficients and subtract the exponent of the denominator from the exponent of the numerator.

Engineering Notation and Metric Prefixes

  • Engineering Notation: A specialized form of scientific notation where the exponent must be a multiple of three (3,6,93, 6, 9, etc.) and the coefficient has one to three digits to the left of the decimal point.

    • Example: 33,00033,000 in scientific notation is 3.3×1043.3 \times 10^4; in engineering notation, it is 33×10333 \times 10^3.

  • Metric Prefixes (Table 1–6): Shorthand for engineering notation powers of ten, used only with units of measure.

    • tera (TT): 101210^{12} (One trillion)

    • giga (GG): 10910^9 (One billion)

    • mega (MM): 10610^6 (One million)

    • kilo (kk): 10310^3 (One thousand)

    • milli (mm): 10−310^{-3} (One-thousandth)

    • micro (μ\mu): 10−610^{-6} (One-millionth)

    • nano (nn): 10−910^{-9} (One-billionth)

    • pico (pp): 10−1210^{-12} (One-trillionth)

  • Usage Examples:

    • 0.025A=25×10−3A=25 mA0.025 A = 25 \times 10^{-3} A = 25\,mA (25 milliamps).

    • 10,000,000Ω=10×106Ω=10 MΩ10,000,000 \Omega = 10 \times 10^6 \Omega = 10\,M\Omega (10 megohms).

  • Calculator Tips: Use the EE or EXP key to enter exponents. Entering 47.0×10347.0 \times 10^3 is done by typing "47.0", pressing "EE", then "3". Displays may show "47.0 03" or "47.0E03". Modes like SCI or ENG automatically format results.

Metric Unit Conversions

  • Basic Rules:

    1. Convert larger unit to smaller unit: Move the decimal point to the right.

    2. Convert smaller unit to larger unit: Move the decimal point to the left.

    3. Shift distance: Find the difference in the exponents of the units.

  • Examples:

    • 0.15 mA0.15\,mA to μA\mu A: Move decimal 3 places right (10−310^{-3} vs 10−610^{-6}) = 150 μA150\,\mu A.

    • 4,500 μV4,500\,\mu V to mVmV: Move decimal 3 places left = 4.5 mV4.5\,mV.

    • 47,000 pF47,000\,pF to μF\mu F: Move decimal 6 places left (10−1210^{-12} vs 10−610^{-6}) = 0.047 μF0.047\,\mu F.

  • Addition with Mixed Prefixes: Convert both to the same prefix before performing the operation. Example: 15 mA+8,000 μA=15 mA+8 mA=23 mA15\,mA + 8,000\,\mu A = 15\,mA + 8\,mA = 23\,mA.

Measured Numbers and Uncertainty

  • Error: The difference between the true or best-accepted value and the measured value. All measurements that don't involve counting are approximations.

  • Accuracy: An indication of the range of error; how well a measurement agrees with a standard. (e.g., measuring a 10.00 mm10.00\,mm gauge block as 10.02 mm10.02\,mm is accurate; 10.8 mm10.8\,mm is not).

  • Precision: A measure of repeatability or consistency. Consistent results that are off-target are precise but inaccurate (often due to calibration error). An instrument cannot be accurate unless it is also precise.

  • Significant Digits: Digits known to be correct in a measured number, including one uncertain digit.

    • Rules for Significance:

      1. Nonzero digits are always significant.

      2. Zeros left of the first nonzero digit are never significant (0.00570.0057 has two).

      3. Zeros between nonzeros are always significant (1502.01502.0 has five).

      4. Zeros to the right of the decimal point in a decimal number are significant (40.040.0 has three).

      5. Whole number zeros to the left of a decimal are uncertain placeholders (e.g., 12,10012,100 could have 3, 4, or 5). Use scientific notation to clarify (e.g., 12.10×10312.10 \times 10^3 has four).

  • Reporting Results: The number of significant digits in a calculation result should never exceed the number of significant digits in the original measurement.

  • Rounding Rules:

    1. If the dropped digit is >5> 5, or 55 followed by nonzeros, increase the retained digit by 1.

    2. If the dropped digit is <5< 5, do not change the retained digit.

    3. Round-to-Even Rule: If the dropped digit is exactly 55, increase the last retained digit only if it makes it even. (e.g., 122.5122.5 rounds to 122122; 123.5123.5 rounds to 124124).

  • Practical Context: Electronics components typically have tolerances of 1%1\%, 5%5\%, or 10%10\%. Therefore, three significant digits are generally appropriate for most non-exacting work.

/

Questions & Discussion

  • Distinction between Base and Derived Units: Base units (like the ampere) are fundamental, while derived units (like the volt or ohm) are defined using combinations of base units.

  • Impact of Meter Loading: A meter can change the actual reading in a circuit by its presence. One must recognize when a reading is potentially inaccurate and avoid reporting digits known to be skewed by loading.

  • Resistor Notation: A value of 1.0 kΩ1.0\,k\Omega on a schematic implies accuracy to the nearest 0.1 kΩ0.1\,k\Omega (100 Ω100\,\Omega).

  • Power Supply Accuracy: If a supply must be set to 10.00 V10.00\,V, the measurement instrument must be accurate to four significant digits.

  • True/False Concepts:

    • Derived units use base units in their definition (True).

    • The base electrical unit is the volt (False; it is the ampere).

    • Supplementary units are used for angular measurements (True).

    • A negative number in scientific notation must have a negative exponent (False; the sign of the coefficient and the exponent are independent).

    • Consistent measurements are always accurate (False; they can be consistently wrong/precise but inaccurate).