Image Guided Radiotherapy (IGRT) – Routine 2D X-ray Image Verification

Introduction to IGRT & 2D X-ray Image Verification

  • Image Guided Radiotherapy (IGRT)- Definition: Use of medical imaging to guide ever-increasingly accurate radiotherapy (RT) at all stages of the patient pathway.

  • Stages impacted

    • Initial staging & disease identification

    • Enhanced target delineation (contouring/CT data acquisition)

    • On-treatment image verification & motion management

    • Treatment delivery monitoring

    • Post-treatment follow-up / disease surveillance

  • 2D X-ray Image Verification- Core component of IGRT; historically the routine method for verifying patient positioning.

    • Images acquired in the treatment room (less than or equal to 2 extra minutes)

    • Compares verification image(s) with reference image(s) (DRR, simulation film or planning CT projection).

  • Modalities

    • MV (megavoltage) EPID images

    • kV (kilovoltage) onboard imager (OBI) images

  • Purpose- Detect & correct translational / rotational setup errors.

    • Confirm internal anatomy alignment (bones, fiducials, sometimes soft tissue).

Imaging Technologies Along the RT Pathway

  • Planar (2D) X-ray Imaging- Single-view planar MV or kV

  • 2D Stereoscopic Imaging- Orthogonal pair (AP & Lat) or oblique pair (non-orthogonal) providing 3-D spatial information

  • 3-D Volumetric X-ray Imaging- kV CBCT, MV CT

  • Non-ionising Imaging- Ultrasound (US), surface/visual systems, implanted electromagnetic transponders, respiratory surrogates

  • Motion-management add-ons- 4-D imaging, gating, tracking, breath-hold techniques

Categories of On-treatment 2D Verification

  • 2D Planar Imaging – single projection (MV or kV)

  • 2D Stereoscopic Orthogonal Imaging – two projections 90 degrees apart (AP + Lat)

  • 2D Stereoscopic Oblique Imaging – two non-orthogonal projections (e.g., gantry-mounted kV-kV pair)

Routine 2D Verification Workflow

  • BEFORE you begin

    1. Review & understand the imaging protocol for the site/fraction.

    2. Confirm acquisition parameters (kV, mAs, MU, gantry angle, panel position, FFD).

    3. Check that the reference image (DRR or CT projection) is correct & matches treatment plan.

    4. Adjust window & level on both reference & verification images to optimise bony contrast.

    5. Acquire verification image(s) -> perform image registration (bony match or fiducials) -> quantify isocentre offsets -> apply couch shift (if less than or equal to tolerance) or seek review.

Bony Match Technique

  • Principle: Rigid registration of stable radiopaque skeletal landmarks because bone does not deform significantly with respiration or filling.

  • Two match types

    • Translational alignment (x, y, z) – always performed.

    • Rotational alignment (yaw, pitch, roll) – assessed if equipment allows 6-DoF couches or noted for physician review.

  • Structures employed by anatomical region:

  • Central Nervous System (CNS)

    • Orbital ridges, nasal septum

    • Inner skull vault border, frontal sinuses

    • Zygoma, occiput, pituitary fossa

  • Head & Neck (H&N)

    • Nasal septum, sinuses, maxilla

    • Base of skull, pituitary fossa

    • Cervical vertebral bodies, clavicles (ant/post borders)

    • Posterior wall of trachea

  • Breast

    • Breast outline; humeral head

    • Lung area & anterior lung border (central lung distance, central flash)

    • Cervical spine, inferior central margin

  • Chest (Thorax)

    • Medial & lateral rib edges

    • Clavicles, sternum, anterior chest wall

    • Carina & trachea

    • Lateral & anterior edges of vertebral bodies

  • 5 & 8. Extremities (Upper & Lower)

    • Edges of long bones (medial/lateral)

    • Joint spaces, tuberosities, protuberances

    • Surgical implants/defects (if present)

  • Abdomen / Abdopelvis

    • Vertebral bodies (cervical to lumbar): lateral, anterior, posterior borders

    • Spinous processes

    • Superior & inferior vertebral endplates

  • Pelvis

    • Iliac crests, sacrum

    • Acetabulum, obturator foramen

    • Pubic symphysis & superior pubic ramus

    • Lumbar vertebral bodies

Bony Match Practices (Visualisation Tools)

  • Reference vs. Verification display options:- Side-by-side (spyglass), overlay (checkerboard), split-screen, subtraction.

  • Start coarse -> refine; zoom & pan as needed.

  • Unmatched vs. fully matched examples highlight impact on translational vectors.

Isocentre Offsets & 6 Degrees of Freedom (6-DoF)

  • Three translational directions

    1. Left/Right (X)

    2. Sup/Inf (Y)

    3. Ant/Post (Z)

  • Three rotational directions (about isocentre)

    1. Yaw – rotation around the cranio-caudal (Y) axis

    2. Pitch – rotation around the left-right (X) axis

    3. Roll – rotation around the ant-post (Z) axis

  • Offsets reported in mm (translations) & degrees (rotations).

  • Typical tolerance values (site- & protocol-specific):- less than or equal to 2 mm translation, less than or equal to 1 degree rotation -> treat; else apply shift or escalate.

2D Planar Single-Image Matching

  • Provides 2 translational & 1 rotational dimension per image.

  • Example (single AP kV):- Visible: Left/Right, Sup/Inf, Yaw.

    • Hidden: Ant/Post, Pitch, Roll (require lateral image).

  • Recommended: acquire orthogonal pair for complete 3-D info.

2D Stereoscopic Orthogonal Imaging Strategy

  • Two images 90 degrees apart share the Sup/Inf dimension.

  • Workflow tips

    1. Match one dimension at a time.

    2. Know which axis each image controls:

    • AP: L/R, Sup/Inf, Yaw

    • Lat: Ant/Post, Sup/Inf, Pitch

    1. Always verify the shared dimension (Sup/Inf) in both images after any adjustment.

    2. Address translations before rotations for clarity.

Hangling Independent Dimensions

  • Variation visible only in L/R, then adjust couch X.

  • Variation visible only in Ant/Post, then adjust couch Z.

  • Use image pair to decouple axes & avoid over-correction.

Rotational Offset Assessment

  • Only two rotations can be clearly visualised with orthogonal 2-D imaging; the third often inferred.

    • Yaw: easiest on AP view, subtle on Lat.

    • Pitch: easiest on Lat view, subtle on AP.

    • Roll: rarely obvious; look for asymmetric rib or pelvic wing appearance.

  • If significant roll suspected, volumetric imaging or 6-DoF correction recommended.

Combined Translational & Rotational Errors

  • Real-world setups show mixture of all 6 DoF.

  • Be systematic:

    1. Perform translational match in primary image.

    2. Cross-check shared dimension.

    3. Evaluate rotations (yaw/pitch) -> decide if within tolerance or requires correction.

    4. Document residuals.

Fiducial Matching

  • Implanted or superficial markers (e.g., prostate gold seeds, liver coils).

  • Used only for translational shifts in routine 2-D matching.

  • Rotations still assessed against adjacent bony anatomy.

  • Advantages: internal target surrogate independent of skeletal motion.

  • Cautions: migration, marker clustering, radiographic visibility (kV > MV).

Practical / Ethical / Safety Considerations

  • ALARA: additional imaging dose must be justified by setup accuracy gains.

  • Imaging frequency: daily vs. weekly – depends on site motion & protocol.

  • Documentation: record offsets, applied shifts, staff initials, and patient response.

  • Training & competency: therapists must understand anatomy, image quality factors, and 6-DoF corrections.

  • Patient comfort & immobilisation: proper devices reduce inter-fraction variability and imaging burden.

Real-world Relevance & Evolution

  • Transition from 2-D to 3-D CBCT for many sites, yet 2-D remains valuable for speed, dose and redundancy.

  • Integration with adaptive RT workflows demands accurate baseline 2-D verification skills.