Introduction to CAD/CAM: Scanning and Comparing
Objective vs. Subjective Assessment in Preclinical Training
- Preclinical dental education traditionally relies on visual inspection and subjective faculty evaluation using standardized rubrics.
- Traditional rubrics evaluate parameters such as facial contour, lingual contour, incisal contour, proximal contacts, embrasures, margin integrity, finish/polish, and occlusion.
- Numerical scoring formulas on manual rubrics compute total percentage grades through point structures:
Total Grade %=(98Total Criteria Points)×100
- Visual inspection exhibits limitations in precision and inter-evaluator reliability, which can lead to grading discrepancies among faculty members and inconsistent student feedback.
Beginner Over-Confidence and Self-Assessment Dynamics
- Novice dental students routinely exhibit over-confidence when evaluating their own technical performance during early practical examinations (such as waxing tooth #8).
- Early-stage students consistently grade their preclinical work significantly higher than evaluations performed by experienced faculty or automated digital assessment tools.
- Timely faculty interaction paired with objective 3D visual feedback tools enables students to recalibrate their self-assessment accuracy rapidly.
Empirical Evidence: The Chiang et al. (2021) Study
- A study evaluated CAD/CAM technology as a self-assessment tool for preclinical waxing compared to traditional student self-assessment (Eur J Dent Educ, 2021; PMID: 33448597).
- Methodology:
- Sample size: 37 preclinical dental students.
- Task: Complete a wax-up of the maxillary left central incisor (tooth #9 / #8 anatomical representation) recreating original tooth anatomy.
- Initial evaluation: Traditional student self-assessment rubric completed.
- Digital scanning: Original unreduced cast and student waxings scanned with an intraoral scanner (E4D, Planmeca).
- Software analysis: Digital waxings superimposed over original models using Planmeca Compare software with tolerance set to 250μm.
- Secondary evaluation: Students completed a post-software self-assessment and an exit survey.
- Quantitative Results:
- 24% of student self-assessment responses changed after reviewing 3D digital comparisons.
- 20% of evaluations downgraded from satisfactory to unsatisfactory upon visual color-map feedback.
- 4% of evaluations upgraded from unsatisfactory to satisfactory.
- The rubric category with the highest rate of evaluation change was the Incisal Edge (49% change).
- The rubric category with the lowest rate of evaluation change was the Interproximal Contact Area (3% change).
- 70% of students strongly agreed that Compare software enabled more effective assessment of Lingual Contour.
- 8% of students strongly disagreed that the software enabled more effective assessment of finishing.
- Conclusions:
- CAD/CAM self-assessment software significantly enhances critical student self-reflection.
- Objective feedback improves student-teacher communication, reduces required one-on-one instructional time, and allows for higher student-to-teacher ratios in preclinical simulation laboratories.
- Provide objective, repeatable, and standardized evaluation criteria independent of subjective faculty variance.
- Allow precise, customized tolerance threshold settings (e.g., 250μm or ±0.1mm).
- Resolve evaluation discrepancies between instructors and students through unambiguous color-coded 3D superimposition.
- Cultivate self-directed motivation, critical thinking, and reflective practice, transforming learners from completion-oriented students into lifelong quality-driven practitioners.
Historical Development of CAD/CAM in Dentistry
Innovation and Early Devices
- Professor François Duret is widely recognized as the pioneer of dental CAD/CAM systems.
- In 1984, Professor Duret patented the first functional dental CAD/CAM device, establishing the theoretical and mechanical foundations for digital optical impressions, computer-aided design, and automated restoration milling.
- This work transitioned dental crown and restoration fabrication from physical impression materials and manual casting to digitized optical capture and computer-guided manufacturing.
Intraoral Scanner Fundamentals and Hardware Handling
Intraoral Scanner (IOS) Principles
- Intraoral scanners rapidly capture optical surface images or video streams to generate precise 3D geometric meshes in real time.
- Spatial surface data is stored in standard digital 3D mesh formats, most commonly STL (Standard Tessellation Language).

Integrated System Components
- Hardware Platform: CEREC Primescan / CEREC AC cart.
- Acquisition & Design Software: CEREC SW 5.2.13.
- Comparative Analysis Software: prepCheck (version 5.1.0).
Ergonomics and Hardware Care
- Handling Rules:
- NEVER lift or maneuver the scanner by its optical mirror tip.
- ALWAYS grip the scanner at its central body base (the black and white ergonomic mid-section).
- After completing a scan, return the wand to its cradle with the optical tip facing forward (toward the user) and the cable/base directed toward the rear of the cart unit.

Wand Activation Methods
- Automatic Activation: Removing the scanner wand from the cradle for the first time while in the Acquisition phase automatically initializes the camera.
- Foot Pedal: Pressing the foot pedal located at the base of the CEREC AC cart toggles the optical scanner on and off.
- Screen Interface: Toggling the soft switch camera icon on the monitor screen turns the scanner stream on or off.
Clinical Technique for Anterior Digital Scanning
Spatial Alignment and Grip
- Hold the scanner body using a stable pen or stylus grip.
- Maintain an optical clearance distance of exactly 2mm between the scanner window lens and the tooth surface.
- Position the scanner wand head perpendicular (90∘) directly over the incisal edge of the target tooth prep.
- Do NOT initiate scanning from facial or lingual approach angles.

Operator Focus and Real-Time Feedback
- Operator eye focus must remain continuously fixed on the computer monitor screen during scanning rather than looking directly into the patient mouth or typodont.
- Screen tracking ensures immediate identification of uncaptured surface areas and gap fill requirements.
Standardized Anterior Scanning Sequence
- Phase 1 (Incisal Surface): Position the optical window perpendicular over the incisal edge of the prepared tooth. Move smoothly along the incisal edge across the arch section.
- Phase 2 (Facial/Buccal Surface): Roll the scanner head 45∘ to 90∘ toward the facial aspect, maintaining a continuous sweeping movement across all facial surfaces.
- Phase 3 (Lingual Surface): Roll the scanner head over the incisal table toward the lingual aspect, capturing marginal ridges, cingulum contours, and lingual fossae.
Criteria for an Acceptable Anterior Scan
- Arch Extent: Scan must continuously span from the first premolar to the opposing first premolar (e.g., tooth #5 to #12 or #21 to #28).
- Anatomical Capture: Complete 3D mesh coverage of the target wax-up and all adjacent arch teeth.
- Embrasures: Full capture of mesial and distal interproximal contact zones and gingival embrasure spaces.
- Soft Tissue Margin: Clear, distortion-free capture of 2–3mm of surrounding gingival/buccal soft tissue.
- Data Density: Complete elimination of optical voids (represented as unrendered white gaps in the mesh). Any white area over critical anatomical regions requires spot-scanning to build required data density.
- Scan Termination: Re-cradling the wand or depressing the foot pedal halts the optical acquisition process.
Step-by-Step prepCheck Workflow for Wax-Up Comparison
Phase 1: Patient and Case Initialization
- Launch CEREC SW 5.2.13 from the desktop screen.
- Select Show Patients on the bottom navigation bar.
- Enter the assigned CAD/CAM student identification code into the database search bar.
- Highlight the target patient profile and click Add Case.
Phase 2: Administration Setup

- In the Administration tab, select target tooth location (Tooth #8 / Maxillary Central Incisor).
- Select Restoration Type: Single Crown.
- Select Design Mode: Biogeneric Individual.
- Select Material: IPS e.max CAD (Grinding) or equivalent designated template block.
- Select Processing Device: Primemill 01.
- Advance to the Acquisition phase.
Phase 3: Image Acquisition
- Ensure the Upper Jaw image folder is active.
- Execute the standardized anterior scan sequence on the typodont carrying the #8 wax-up (extending 1st premolar to 1st premolar).
- Verify complete surface data density without critical white voids.
- Click the Model phase tab on the top process bar or click the forward arrow at the bottom screen margin.
Phase 4: Model Processing and Margin Tracing
- Under Model Tools, select Draw Margin.
- Choose Manual mode.
- Trace a 360∘ continuous line around the base margin of the wax-up, extending over the incisal edge at the mesial and distal contact points:
- Double-click the starting location to initiate the line.
- Single-click incrementally around the perimeter to place control anchor points.
- Double-click the original red starting dot to close the margin loop.
- Rotate the 3D model 360∘ to verify margin accuracy.
Phase 5: Setting Insertion Axis
- Select Set Insertion Axis from the bottom Model Phase menu.
- Rotate the 3D model so the viewing direction looks straight down along the long axis of the incisal edge of the #8 wax-up.
- Click Ok to lock the path of insertion.
Phase 6: Exporting to prepCheck Application
- Click the Dentsply Sirona icon menu located in the top left corner of the screen.
- Select Run Application….
- Click the prepCheck 5.1.0 application icon.
- In the
prepCheck-Exporter window, set Course to DENTD 1500. - Click Show Details to verify the master comparison template assignment.
- Confirm the template reads Template #8 Crown Wax-Up.
- Click Open in prepCheck.
Quantitative Analysis and Interpretation in prepCheck
3D Color-Coded Comparison Heat Map

- Green Surfaces: Indicates overcontoured wax-up regions (excess material beyond master template). Clinical Action: Remove wax.
- Red Surfaces: Indicates undercontoured wax-up regions (deficient material compared to master template). Clinical Action: Add wax.
- Blue Surfaces: Indicates high-accuracy regions within the acceptable deviation threshold of ±0.1mm (±100μm) relative to the master typodont template.
Cursor Inspection and Numerical Point Measurement
- Hovering the mouse cursor over any point on the 3D mesh displays the exact distance discrepancy under Cursor Details.
- Displays precise positive values for overcontoured areas (e.g., +0.90mm, +0.92mm) and negative values for undercontoured areas (e.g., −0.45mm).
Object Display Controls
- Adjust the Master Preparation opacity slider to 50%.
- Adjust the Preparation (Sample Wax-Up) opacity slider to 100%.

- Rotate the 3D model into a proximal (mesial or distal) profile view.
- Click Slice under the Manual Analysis tool panel.
- 3D Manipulation Handles:
- Sphere Control Handles: Click and drag spherical handles to adjust the cross-sectional cutting plane angle.
- Arrow Control Handles: Click and drag directional arrows to translate the slice plane position mesially or distally at a fixed angle.
- Line Profile Interpretation:
- Green Profile Line: Represents the master template typodont tooth contour.
- Blue Profile Line: Represents the student wax-up sample contour.
- The Slice tool can be dynamically activated from any orientation angle (360∘) across the arch.
- Select Measure Distance under the Manual Analysis panel.
- Click the primary point of interest on the sample mesh.
- Click the corresponding secondary point on the reference mesh to calculate exact spatial deviation in millimeters.
Pedagogy and Critical Thinking Integration
- Digital hardware and analysis software serve exclusively as objective data collection tools; they do not replace clinical judgment.
- Learners must interpret 3D surface maps and cross-sectional slices critically to plan targeted physical corrections.
- Corrective wax modifications (adding vs. carving) executed based on quantitative feedback reinforce motor skill acquisition and spatial anatomical awareness.
Academic References
- Björn AL, Björn H, Grkovic B. Marginal fit of restorations and its relation to periodontal bone level. II. Crowns. Odontol Revy. 1970;21:337–346.
- Chiang H, Staffen A, A Abdulmajeed A, Janus C, Bencharit S. Effectiveness of CAD/CAM technology: A self-assessment tool for preclinical waxing exercise. Eur J Dent Educ. 2021 Feb;25(1):50-55. doi: 10.1111/eje.12576. PMID: 33448597.
- Garrett PH, Faraone KL, Patzelt SB, Keaser ML. Comparison of Dental Students’ Self-Directed, Faculty, and Software-Based Assessments of Dental Anatomy Wax-Ups: A Retrospective Study. J Dent Educ. 2015;79(12):1437-1444. doi:10.1002/j.0022-0337.2015.79.12.tb06043.x.
- Greany TJ, Yassin A, Lewis KC. Developing an All-Digital Workflow for Dental Skills Assessment: Part I, Visual Inspection Exhibits Low Precision and Accuracy. J Dent Educ. 2019;83(11):1304-1313. doi:10.21815/JDE.019.132.
- McPherson KR, Mennito AS, Vuthiganon J, Kritzas YG, McKinney RA, Wolf BJ, Renne WG. Utilizing self-assessment software to evaluate student wax-ups in dental morphology. J Dent Educ. 2015 Jun;79(6):697-704. PMID: 26034035; PMCID: PMC4740729.
- Renne WG, McGill ST, Mennito AS, Wolf BJ, Marlow NM, Shaftman S, Holmes JR. E4D Compare Software: An Alternative to Faculty Grading in Dental Education. J Dent Educ. 2013;77(2):168-175. doi:10.1002/j.0022-0337.2013.77.2.tb05459.x.
- Sly MM, Barros JA, Streckfus CF, Arriaga DM, Patel SA. Grading Class I Preparations in Preclinical Dental Education: E4D Compare Software vs. the Traditional Standard. J Dent Educ. 2017 Dec;81(12):1457-1462. doi: 10.21815/JDE.017.107. PMID: 29196334.