Ohm's Law and Circuit Analysis Notes

Voltage Types

  • Open Circuit Voltage: Voltage of a power source existing without a load applied.

  • Dynamic Voltage: Voltage of a power source measured while the circuit is in operation.

Ohm's Law Fundamentals

  • Definition: Formulated by George Simon Ohm, stating that the voltage across a conductor is directly proportional to the current flowing through it, provided all physical conditions and temperatures remain constant.

  • Scope: Defines the relationship between voltage and current in solid and liquid conductors.

Formulas and Variables

Ohm's Law Triangle
  • Electromotive Force (EE): Measured in volts (V\text{V}).

    • Formula: E=I×RE = I \times R

  • Current Intensity (II): Measured in amperes (A\text{A}).

    • Formula: I=ERI = \frac{E}{R}

  • Resistance (RR): Measured in ohms (Ω\Omega).

    • Formula: R=EIR = \frac{E}{I}

Electrical Power

  • Power (PP): Rate at which electricity performs work, measured in watts (W\text{W}).

    • Formula: P=E×IP = E \times I

  • Horsepower Conversions:

    • 1 hp=746 W1\,\text{hp} = 746\,\text{W}

    • hp=P746\text{hp} = \frac{P}{746}

    • kW=hp×0.746\text{kW} = \text{hp} \times 0.746

Series Circuits

  • Path: Contains only one path for current flow.

  • Current: Flow is identical throughout the circuit (It=I1=I2=I3I_t = I_1 = I_2 = I_3

  • Total Resistance: Sum of all individual resistances (Rt=R1+R2+R3+…R_t = R_1 + R_2 + R_3 + \dots ).

  • Voltage Drop: Sum of individual voltage drops equals total applied voltage (Et=E1+E2+E3+…E_t = E_1 + E_2 + E_3 + \dots).

  • Open Circuit Effect: An open anywhere in the circuit halts current flow.

Parallel Circuits

  • Paths: Contains more than one path for current flow.

  • Voltage: Voltage drop across each branch equals total applied voltage (Et=E1=E2=E3E_t = E_1 = E_2 = E_3

  • Total Current: Sum of individual branch currents (It=I1+I2+I3+…I_t = I_1 + I_2 + I_3 + \dots).

  • Total Resistance Formulas:

    • Conductive/Reciprocal method: 1Rt=1R1+1R2+1R3+…\frac{1}{R_t} = \frac{1}{R_1} + \frac{1}{R_2} + \frac{1}{R_3} + \dots

    • Product over sum method (for two resistors): Rt=R1×R2R1+R2R_t = \frac{R_1 \times R_2}{R_1 + R_2}

  • Resistance Behavior: Total resistance (RtR_t) is always smaller than the smallest individual resistor in the circuit; adding branches decreases total resistance.

  • Open Circuit Effect: An open in one branch has little or no effect on the rest of the circuit.

Series-Parallel Circuits

  • Structure: Combines both series and parallel component connections.

  • Calculation Procedure:

    • Calculate and simplify parallel branches first starting farthest from the power source using the product over sum or reciprocal method.

    • Add the simplified parallel resistance value to the series resistances to determine total circuit resistance (RtR_t).


__________________________________________________________________________


Voltage Types
  • Open Circuit Voltage: Voltage measured across a power source or battery when no load is applied and no current flows through a complete circuit.

  • Dynamic Voltage: Voltage of a power source or battery measured while the circuit is closed and actively operating under load.

Ohm's Law Fundamentals
  • Definition: Formulated by George Simon Ohm, stating that the voltage across a conductor is directly proportional to the current flowing through it, provided all physical conditions and temperatures remain constant.

  • Scope: Governs the fundamental relationship between voltage, current, and resistance in solid and liquid conductors.

Formulas and Variables


Ohm's Law Triangle

- Electromotive Force (EE): Measured in volts (V\text{V}). Represents the electrical pressure driving current.

- Formula: E=I×RE = I \times R

    

  • Current Intensity (II): Measured in amperes (A\text{A}). Represents the rate of electrical charge flow.

    • Formula: I=ERI = \frac{E}{R}

    

  • Resistance (RR): Measured in ohms (Ω\Omega). Represents the opposition to current flow within the conductor.

    • Formula: R=EIR = \frac{E}{I}

    

Electrical Power
  • Power (PP): The rate at which electrical energy performs work or converts into heat, measured in watts (W\text{W}).

    • Formula: P=E×IP = E \times I or W=V×AW = V \times A

    

  • Power Dissipation: Individual component power consumption is calculated using component voltage drop and current flow (Pn=En×InP_n = E_n \times I_n). Total power in any circuit equals the sum of individual component power dissipations (Pt=P1+P2+P3+…P_t = P_1 + P_2 + P_3 + \dots).

  • Horsepower Conversions:

    • Equivalence: 1 hp=746 W1\,\text{hp} = 746\,\text{W}

    • Watts to Horsepower: hp=P746\text{hp} = \frac{P}{746}

    • Horsepower to Kilowatts: kW=hp×0.746\text{kW} = \text{hp} \times 0.746

    • Kilowatts to Horsepower: hp=kW0.746\text{hp} = \frac{\text{kW}}{0.746}

    

Series Circuits
  • Path: Contains only one single continuous path for current flow.

  • Current: Flow is uniform and identical throughout every component in the circuit (It=I1=I2=I3I_t = I_1 = I_2 = I_3).

  • Total Resistance: Sum of all individual resistances (Rt=R1+R2+R3+…R_t = R_1 + R_2 + R_3 + \dots). Total resistance increases as more series components are added.

  • Voltage Drop: Sum of individual voltage drops equals total applied voltage (Et=E1+E2+E3+…E_t = E_1 + E_2 + E_3 + \dots).

    • Formula for component voltage drop: En=It×RnE_n = I_t \times R_n

    • Voltage drops proportionally according to the resistance value of each resistor.

    

  • Open Circuit Effect: An open or break anywhere in a series circuit completely halts current flow throughout the entire circuit.

Parallel Circuits
  • Paths: Contains two or more parallel branches providing multiple independent paths for current flow.

  • Voltage: Voltage drop across each branch equals total applied voltage (Et=E1=E2=E3E_t = E_1 = E_2 = E_3).

  • Total Current: Sum of individual branch currents (It=I1+I2+I3+…I_t = I_1 + I_2 + I_3 + \dots). Branch current varies inversely with branch resistance (In=EtRnI_n = \frac{E_t}{R_n}).

  • Total Resistance Formulas:

    • Conductive / Reciprocal method (for any number of branches): 1Rt=1R1+1R2+1R3+…\frac{1}{R_t} = \frac{1}{R_1} + \frac{1}{R_2} + \frac{1}{R_3} + \dots

    • Product over sum method (for two parallel resistors): Rt=R1×R2R1+R2R_t = \frac{R_1 \times R_2}{R_1 + R_2}

    

  • Resistance Behavior: Total resistance (RtR_t) is always smaller than the smallest individual resistor branch; adding parallel branches decreases total resistance and increases total current.

  • Open Circuit Effect: An open in one branch stops current flow only in that branch and has no effect on the operation of the remaining branches.

Series-Parallel Circuits
  • Structure: Combines both series component connections and parallel branch networks within a single circuit.

  • Calculation Procedure:

    1. Simplify Parallel Branches: Identify parallel branch networks starting farthest from the power source and calculate equivalent parallel resistance (RpR_p) using the product over sum or reciprocal method.

    2. Find Total Resistance (RtR_t): Add equivalent parallel resistance (RpR_p) to all series resistors (Rt=Rseries+RpR_t = R_{\text{series}} + R_p).

    3. Calculate Total Current (ItI_t): Use total voltage and total resistance (It=EtRtI_t = \frac{E_t}{R_t}).

    4. Calculate Voltage Drops: Calculate voltage drops across series components (Eseries=It×RseriesE_{\text{series}} = I_t \times R_{\text{series}}) and subtract from total voltage to find voltage across parallel branches (Ep=Et−EseriesE_p = E_t - E_{\text{series}}).

    5. Calculate Branch Currents: Find individual current through each parallel branch using branch voltage (Ibranch=EpRbranchI_{\text{branch}} = \frac{E_p}{R_{\text{branch}}}).