APU
What are the primary functions
Heating, Bleed Air, Electrical Power
What is in the box back there?
Dual gas turbine APU’s
Provides electrical power and bleed air for engine start and heating the aircraft on the ground.
Electrical power is supplied by a 25 KVA (Kilovolt-Ampere) generator which can be installed in either APU
How can you tell what APU has the generator?
The forms, the light, the wires in the enclosure
Right Hydraulic system provides pressure. Can cross-over if necessary
Checklist
Steps 1-7 says “may be accomplished by the pilot team.”
What do the pilots do if the APU battery checks good?
Rings bell - Approximately 24 Volts
If battery voltage is below 18 volts, APU fire extinguisher will discharge when APU
Show that it doesn't go below 18 on a picture in the Reference in Electrical F 1-236
Say the APU battery doesn't check good, can I use another battery?
Yes the pilots would be able to disengage the battery and connect to the aircraft battery
Does the bell actually Indicate the battery is good?
No, it is a part of their checklist. Our pilots are good about not ringing unless it is good but you may not always be flying with our great pilots.
Electric Current Buzzing Generator
Enclosure Cabinet Breakers Generator
APU enclosure
Hydraulic and fuel
What is the caution??
Do you have to check on an EWO start or emergency taxi?
NO
APU equipment cabinet
Hydraulic fluid
Breakers
Generator Switch
Start accumulators
Started with hydraulic motor operated by pressure from two accumulators
After each start attempt, the accumulators must be recharged to:
How can we charge them?
1 min - Engine driven
6 min - Accumulators
500 Full strokes roughly 30 mins
Each Accumulator pressurized for 1 start
Pressure: 3000 +/- 350
Surge damper
What is a surge damper
Dampens the shocks from hydraulics. We don’t want all the pressure to hurt our system.
We are told to check it Against chart
Where are the charts?
What is it filled with?
Nitrogen
Maintenance will have to refill
Relief Valve is only to be used my maintenance
Fire/Dslbd light doesnt come on.
Get into checklist (APU Fire detector test failure)
FIRE/DSBLD switch is pressed.
If the battery is disengaged due to low voltage, the 3 APU BATTERY CHARGER circuit breakers must be opened to avoid an APU battery fire.
Operating Modes
Gen Only - 150 pph
Gives electrical power only
Can start in Aft APU
Normal - 250 pph
Gives electrical power and bleed air
Where can we start in normal?
Crew Entry, Pilot, Aft APU
Starts both apu if from the crew entry chute
This switch is safety wired
EWO Mode - 275 pph
Used for minimum engine start time
Upgrades both APU’s
Can start at Pilot APU Control Panel
How would I upgrade?
How do I downgrade?
What about EWO?
-- Surge bleed pulsing occurs after ready light comes on shutdown APU
Fuel System
Where does the APU fuel from?
DC powered Boost Pump in Engine #2
What happens if I can’t get fuel from number 2
Bypass Port for fuel suction
APU Control System
APUs are controlled by a (ESCU) Electronic Sequencing Control Unit
Aft Control Panel Cabinet, 1 for each APU
Controls the following functions:
Starting sequence, acceleration, on speed operation, operation within the temperature limits, inlet guide van control, surge valve control, engine shutdown
The brains of the APU governs start-up, temp limits, on-speed, shutdown etc.
Incorp a BIT capability which monitors and stores shutdown data and provides failure indications
Dash-1 contains BIT codes that allow another start attempt -- all else required MX action. BIT codes are black/white - read white i.e. 1-3-6
APU Doors
Hydraulically operated inlet & exhaust doors
Mechanically linked together
Manual Operation
How do we do it? Refer to (Manual Operation of APU Doors Checklist)
Each APU is equipped with a hydraulic operated inlet and exhaust doors - can be operated manually.
If they are opened manually they must be closed manually
What are the Operating Temps?
Cold weather?
OAT is Below 40 degrees F or 4 C and visible moisture
Hot weather?
-- There are time limitations associated with operations in NORMAL - fuel vapors
Normal mode operating timing
Why do we care?
In the deid really hot fixing engines may have to shut down the APU
Only applies in normal
APU Starting System
BIT Codes
Indicated a problem within the APU
How would you know what action is required?
Read paragraph in section 3
Shutdown for fire = no restart (Mx Approval)
When in doubt, ask Mx
When does the ready light come on?
When the APU reaches 100% in normal or EWO mode
When does it go out?
When the APU is downgraded to the Gen Only mode or when a shutdown is initiated
Fire Protection System
Abnormal operation of the APUs are limited due to auto shutdown for malfunctions
Each APU has its own fireproof compartment
2 fire doors for access
Emergency stop switch - closes fuel valve
What situation would I use the emergency stop?
Yes the emergency stop buttons
What if it Senses a fire/ overheat condition
Automatically discharges
Dual loop Fire detection sensors
When activated, the loop signals the fire detector system
Illuminates the fire lights
Signals the electronic sequence control unit to shut down the APUs. The ESCU initiates the shutdown sequence and illuminates the DSLBD lights
Closes the fire control shutoff valves to remove the oxygen source from the fire
Discharges the respective fire extinguishers
Talk about the electricity needing enough voltage to reach the end of the loop, if not it may create a shortage.
What is the Note?
If the battery voltage reads at or below 21 volts the APU fire extinguisher may activate when the detection system is checked
How long does it remain energized
5 minutes after APU shutdown