Introductory Organic Spectroscopy: IR, Mass Spec, and NMR Study Notes

Foundational Concepts and Review # Functional groups must be reviewed meticulously as the exam will feature standard groups exclusively. # Essential parameters and rules include the following: ## Index of Hydrogen Deficiency (IHD) and Rule of 13 # The Index of Hydrogen Deficiency (IHD) determines the degree of unsaturation in a molecule. The Rule of 13 is utilized during mass spectrometry analysis to derive potential chemical formulas. # The Nicobin roll and C−HC-H equivalents are also foundational topics used consistently throughout the course. ## Drawing and Physical Properties # Hybridization (sp3sp^3, sp2sp^2, spsp) is required context for discussing chemical shifts in NMR and IR absorption peaks. # Formal charge must be correctly indicated. # All hydrogen atoms (HH) attached to heteroatoms (e.g., OO, NN, SS) must be explicitly shown in drawings, whereas hydrogens on carbon are generally implicit unless needed for clarity. # Infrared Spectroscopic (IR) Analysis ## Principles of IR Spectroscopy # Infrared spectroscopy involves the absorption of energy that causes bond vibrations. Measurements are taken in wave numbers (vˉ\bar{v}), which are proportional to energy. # Diagnostic Region: 4000 cm−14000\,cm^{-1} to 1500 cm−11500\,cm^{-1}. # Fingerprint Region: Below 1500 cm−11500\,cm^{-1}. # IR Activity Requirement: A vibration must result in a change in the net dipole moment to be IR active. For example, covalent homonuclear molecules like O2O_2 are not IR active. ## IR Axis and Variables # Y-axis: Percent Transmittance (from 00 to 100%100\%). # X-axis: Wave number (vˉ\bar{v}), which represents frequency. # High energy stretches or bends appear on the left (4000 cm−14000\,cm^{-1}), while lower energy ones appear to the right. # Intensity: A strong absorbing peak corresponds to low transmittance, indicating a large dipole change. ## Factors Affecting Wave Number (vˉ\bar{v}) # Hooke's Law: Models bonds as springs where frequency is determined by bond stiffness (kk) and reduced mass (μ\mu). Wave Number∝kμWave\,Number \propto \sqrt{\frac{k}{\mu}}. # Mass Effect: Wave number is inversely proportional to mass (vˉ∝1mass\bar{v} \propto \frac{1}{mass}). A C−DeuteriumC-Deuterium bond is lower energy (lower wave number) than a C−HC-H bond because deuterium is heavier. # Bond Order: Wave number is proportional to bond stiffness (kk). Triple bonds (>2100 cm−1>2100\,cm^{-1}) > Double bonds (1600−1850 cm−11600-1850\,cm^{-1}) > Single bonds (<1500 cm−1<1500\,cm^{-1}). # Electronegativity (Inductive Effect): Nearby electronegative atoms pull electron density, strengthening bonds. For example, acid chlorides appear at 1800 cm−11800\,cm^{-1}, which is higher than standard carbonyls. # Resonance and Conjugation: Resonance weakens the bond order, decreasing the wave number by approximately 15 cm−115\,cm^{-1} to 30 cm−130\,cm^{-1}. Alkenes in benzene are 50 cm−150\,cm^{-1} lower than standard alkenes. # Ring Strain: Increasing ring strain (smaller ring size) increases the frequency and wave number for bonds within/attached to the ring. # Hydrogen Bonding: Inversely related to wave number. Hydrogen bonding weakens the bond it associates with, lowering the absorption frequency. ## Qualitative IR Features # Broadness: Indicative of hydrogen bonding, common in alcohols (OHOH) and carboxylic acids. # Peak Identification Example: Benzene is identified by weak peaks around 1606 cm−11606\,cm^{-1} (C=CC=C), overtones, and C−sp2HC-sp^2H stretches above 3000 cm−13000\,cm^{-1}. # Mass Spectrometry (MS) Techniques ## Ionization Methods # To be detected in Mass Spec, a species must be a charged ion. # Electron Ionization (EI): Hard ionization. Bombards molecules with electrons to form M+⋅M^{+\cdot} radical cations and numerous fragments. Used for molecules in the 10001000 to 20002000 mass range. # Chemical Ionization (CI): Soft ionization using reagent gases. Allows control over fragmentation. Produces species like [M+H]+[M+H]^+ or [M−H]−[M-H]^-. # Electrospray Ionization (ESI): Soft ionization via Coulombic explosion. Can produce multiply charged clusters and is suitable for large molecules. Common ions include [M+H]+[M+H]^+, [M+NH4]+[M+NH_4]^+, or [M+Metal]+[M+Metal]^+. # Fast Atom Bombardment (FAB): Uses a gas beam for ionization. Can form dimers like [2M+H]+[2M+H]^+ and adducts with group 1 metals (Sodium, Potassium). # Matrix-Assisted Laser Desorption/Ionization (MALDI): Uses a laser on a matrix. Preferred for very large molecules; limited by matrix interference for small molecules. ## Data Interpretation and Isotope Effects # Base Peak: The most intense peak (100%100\% abundance). # Molecular Ion (MM): Represents the nominal mass of the molecule. # Nitrogen Rule: An odd molecular mass implies an odd number of nitrogen atoms (usually 11, 33, or 55). # Isotope Ratios: # Fluorine: 3:13:1 ratio of MM to M+2M+2 (transcript citation). # Bromine: 1:11:1 ratio of MM to M+2M+2. # Sulfur: 20:120:1 ratio of MM to M+2M+2. # Chlorine: Uses 35Cl^{35}Cl for MM and 37Cl^{37}Cl for M+2M+2. ## Fragmentation Mechanisms # One-Bond Cleavage: Typically converts an even molecular ion into an odd-mass fragment (Even→OddEven \rightarrow Odd). Mechanisms include alpha, beta, or direct cleavage. # Alpha Cleavage: Occurs next to a heteroatom to form stable oleum ions (e.g., oxonium or ammonium ions). # Two-Bond Cleavage: Converts an even molecular ion into an even-mass fragment (Even→EvenEven \rightarrow Even). Mechanisms include Beta Elimination, McLafferty Rearrangement, and Retro-Diels-Alder. # Beta Elimination: A leaving group (like a halogen) is lost while a beta-hydrogen is eliminated to form an alkene radical cation. # Nuclear Magnetic Resonance (NMR) Spectroscopy ## Fundamentals and Instrumentation # NMR measures nuclear spin flips in the presence of an external magnetic field (B0B_0). # To be NMR active, the nuclear spin (II) must not be zero. Ideally, I=1/2I = 1/2 for a dipole system with two spin states (alphaalpha and betabeta). # Signal strength is maximized by increasing the gap (ΔE\Delta E) between spin states, which requires higher-strength (expensive) magnets. # Chemical Shift Scale: # 1H NMR^1H\,NMR: Approximately 12 PPM12\,PPM to −1 PPM-1\,PPM (report to two decimal places). # 13C NMR^{13}C\,NMR: Approximately 220 PPM220\,PPM to −20 PPM-20\,PPM (report to one decimal place). ## Determinants of Chemical Shift (δ\delta) # Electronegativity: Pulls electron density away (deshielding), moving peaks to the left (downfield). # Hybridization: sp2sp^2 is most downfield; spsp and sp3sp^3 are more upfield. # Magnetic Anisotropy: Caused by the molecule's own magnetic field. Pi bond cones (C=CC=C, benzene, carbonyls) are generally deshielding outside the cone and shielding inside. Sigma bond cones in alkyl chains are deshielding. # Hydrogen Bonding and PKA: Increased H-bonding decreases PKA and shifts signals downfield. Carboxylic acids appear at 10−12 PPM10-12\,PPM, while alcohols appear at 1−5 PPM1-5\,PPM. # Resonance: Moving electron density via resonance can shift signals downfield (if removing density) or upfield (if adding density). ## Multiplicity and Coupling # Coupling (JJ-values): Measured in Hertz (HzHz). Interaction with neighboring spins creates peak splitting. # Simple/First Order Splitting: Follows the n+1n+1 rule and Pascal’s Triangle (Doublets, Triplets, Quartets). # Complex First Order: Occurs when neighbors are non-equivalent. Requires splitting trees to determine multiple JJ-values (e.g., doublet of doublets). # Long-Range Coupling (2J2J to 5J5J): Occurs in special cases, often involving pi systems. ## Carbon-13 and DEPT Experiments # 13C^{13}C NMR is often proton (HH)-decoupled to simplify the spectrum into singlets. # Distortionless Enhancement by Polarization Transfer (DEPT): # DEPT 135: CHCH and CH3CH_3 peaks point up; CH2CH_2 peaks point down; quaternary carbons are absent. # DEPT 90: Only CHCH peaks appear (pointing up). ## Questions & Discussion # Why is an IR peak "tall" or deep? It is due to the dipole moment. A larger dipole change during vibration leads to stronger absorbance and lower transmittance. # Carbonyl Range Identification: Ketones and Aldehydes appear between 220−190 PPM220-190\,PPM. Esters, Amides, and Carboxylic Acids appear between 190−150 PPM190-150\,PPM. # Problem Solving Strategy: Rule out candidates using the number of unique peaks, integration, and signature chemical shifts (e.g., Aldehyde at 9−10 PPM9-10\,PPM, Benzene at 7−8 PPM7-8\,PPM).