Comprehensive Study Notes on Master Plumbing Code and Regulation Week 2024-2025
Board of Master Plumbers and the IRR of RA 1378
- Chairperson: Reynald B. Ilagan (Professional Mechanical Engineer).
- Member: Pedrito D. Camilet, Jr. (Professional Electrical Engineer); Chairman of the Unification of Master Plumbers; Chairman of the Revision and Update of RNPCP.
- Member: Jaime Jajay E. Cruz (Professional Mechanical Engineer).
- Definition of IRR of RA 1378: Rules and Regulations Implementing Republic Act (RA) No. 1378 or the Plumbing Law.
- Key Dates:
- Adopted: April 18, 2024.
- Business Mirror Publication: May 3, 2024.
- Effective Date: May 19, 2024 (after 15 days effectivity).
- Sections of the IRR of RA 1378:
- Section 1: Short Title
- Section 2: Practice of Master Plumbing
- Section 3: Definition of Terms
- Section 4: Creation and composition of Board for MP
- Section 5: Qualifications of the Members of the Board
- Section 6: Board, A Collegial Body
- Section 7: Meetings of the Board
- Section 8: Terms of Office
- Section 9: Removal of a Board Member
- Section 10: Compensation and Allowances of the Board Members
- Section 11: Supervision of the Board, Custodian of its Records, Secretariat and Support Services
- Section 12: Duties and Functions of the Chairperson
- Section 13: Duties and Responsibilities of the Board
- Section 14: Basic Principles
- Section 15: Application for MPLE
- Section 16: Subjects for MPLE
- Section 17: Registration of Successful Examinees
- Section 18: Issuance of COR and PIC
- Section 19: Exemption from Examination and Registration
- Section 20: Non-issuance of COR
- Section 21: Suspension or Revocation of Certificates
- Section 22: Renewal of PIC
- Section 23: Foreign Reciprocity
- Section 24: Prohibited Acts
- Section 25: Separability Clause
- Section 26: Effectivity
Definitions and Scope of Practice
- Summary of IRR categories:
- Scope of MP Profession.
- Duties and Responsibilities of the Board.
- Master Plumbing Licensure Examination (MPLE).
- Master Plumber: A person technically and legally qualified and licensed to practice Master Plumbing without limitations in accordance with RA No. 1378, after having passed the examination conducted by the Board and the Commission, and received a valid Certificate of Registration (COR) and Professional Identification Card (PIC) issued by the Commission.
- Exclusions from Scope: The Sewage Treatment Plant (STP) is not within the scope of a Master Plumber.
- Scope of Sanitary Engineering:
- Pollution Control.
- Sanitation.
- Environmental Engineering.
- Public Health.
- Public Sewer.
Board Membership and Governance
- Section 5 (Qualifications): A member of the Board shall, at the time of appointment, possess the following:
- Citizen and resident of the Philippines.
- Must be at least thirty (30) years of age.
- Must be a Registered Master Plumber with a valid COR and PIC and an active practitioner as such for not less than five (5) years prior to his/her appointment.
- Has never been convicted of any offense involving moral turpitude.
- Section 12 (Duties of the Chairperson):
- Acts as the head of the Board.
- Equitably assigns examination subjects.
- Designates members to preside over administrative case hearings (except where the issue strictly concerns practice).
- Assigns other duties and manages work supervision.
- Acts as the official spokesperson for the Board in the Commission and other government agencies.
Administration of the MPLE
- Board Responsibilities:
- Prepare and issue syllabi or tables of specifications (TOS).
- Prepare examination questions strictly within the syllabus scope.
- Score and rate papers; submit results within ten (10) days from the last day of examination.
- Determine the passing general average rating, subject to Commission approval.
- Section 13 (Old RA 1378 Qualifications vs. New):
- Old/New shared: Minimum 21 years of age; Filipino citizen; Good moral character; High school graduate.
- Experience: Requires at least five (5) years of experience in actual plumbing work under a Registered Master Plumber (RMP), certified under oath.
- Educational Exemption: Graduates in Sanitary Engineering, Civil Engineering, Mechanical Engineering, Chemical Engineering, Mining Engineering, or Architecture are allowed to take the MPLE without the five (5) years of experience requirement.
- Examination Subjects (Section 16 - New IRR):
- Plumbing Arithmetic: 10%
- Plumbing Code: 10%
- Sanitation, Plumbing Design and Installation: 40%
- Practical Problems: 40%
- Note: The Board reserves the right to modify, adjust, or re-cluster these subjects.
Comparative Legislation and Definitions
- RNPCP Definition of Fixture: A receptacle other than a trap attached to a plumbing system in which water or wastes may be collected or retained for ultimate discharge into the plumbing system.
- Plumbing Fixtures (RNPCP): Approved-type installed receptacles, devices, or appliances supplied with water or receiving liquid-borne wastes. Industrial/commercial tanks and vats are not plumbing fixtures but may discharge into them.
- IRR of RA 1378 Definition of Plumbing Fixture: A receptacle other than a trap attached to a plumbing system in which water or wastes may be collected or retained for ultimate discharge into the plumbing system.
- RA 1378 (Old) Administrative Costs:
- Examination fee: 35 pesos.
- COR fee: 10 pesos.
- Board compensation: 10 pesos per applicant examined.
- Records kept by: Bureau of Civil Service.
- IRR of RA 1378 (New) Administrative Costs (Section 10/11):
- Compensation/Benefits: Comparable to other regulatory boards as provided by the General Appropriation Act.
- Supervision/Records: The Board is under the Commission's general supervision; the Commission keeps all records (applications, papers, results, minutes).
Code of Ethics (2025 Version)
- Resolution: Resolution No. 02, Series of 2025.
- Consultative Meeting: June 14, 2024.
- Resolution Date: March 18, 2025.
- Publication Date: March 25, 2025 (Business Mirror).
- Effectivity Date: April 10, 2025.
- Structure:
- Article I: Duties to the Profession (8 Sections).
- Article II: Duties to Client and Employer (9 Sections).
- Article III: Duties to Fellow Master Plumbers (5 Sections).
- Article IV: Final Provisions (2 Sections).
Administrative Regulations and Permitting
- Filing: The Registered and Licensed Master Plumber (RLMP) files the plumbing permit application at the Office of the Building Official (OBO).
- Submission Requirements: Six (6) sets of all plumbing plans, drawings, design analyses, computations, technical specifications, and bills of materials must be signed and sealed by an RLMP.
- Retention of Plans:
- 1 set: Administrative Authority.
- 2 sets: Applicant.
- 2 sets: Owner.
- 1 set: Kept at jobsite at all times.
- Partial Permit: Allows construction of parts of a complicated system before full approval; does not guarantee a total system permit.
- Permit Expiration:
- Null and void if work does not commence within one (1) year.
- Null and void if work is suspended or abandoned for 120 days.
- Renewal fee: 50% of the original fee.
- Maintenance: Owner is responsible for maintaining all systems in proper operating condition.
- Inspection Protocols:
- No portion concealed until inspected/approved.
- Inspector must be a Registered Master Plumber.
- Accessory replacement: Use allowed if inspection request is filed within 72 hours after completion and before concealment.
- Advance notice: Inspection requests must be filed at least three (3) working days in advance.
- Seal Design (Proposed):
- Upper Portion: "Master Plumber".
- Upper Center: Registration Number.
- Center: Name of the RLMP.
- Center Below Name: Date of Registration.
- Lower Portion: "Professional Regulation Commission".
Piping Materials: Identification and Sizing
- Pipe vs. Tube:
- Pipe: Denoted by Inside Diameter (ID). For Nominal Pipe Size (NPS) <14 inches, OD is greater than NPS; for NPS ge14 inches, OD equals NPS.
- Tube: Denoted by Outside Diameter (OD). Dimension is set by OD and Wall Thickness (WT).
- Pipe Sizing Formula: textSchedule=1000times(P/S)
- P = internal service pressure (psig).
- S = ultimate stress of material (psi).
- Standard Dimension Ratio (SDR): The ratio of pipe diameter to wall thickness.
- Joint Types:
- Ball Joint: Allows movement in every direction.
- Brazed Joint: Joined by melted alloy higher than 449circC.
- Soldered Joint: Joined by melted alloy between 149circC to 427circC.
- Welded Joint: Parts joined in a plastic molten state.
- Slip Joint: Consists of a compression nut, friction ring, and compression washer.
- Standard NPS Data Examples:
- NPS 4: OD = 4.500 in; ID = 4.026 in.
- NPS 12: OD = 12.75 in; ID = 11.938 in.
- NPS 14: OD = 14.000 in; ID = 13.124 in.
Classification of Pipe Materials
- Cast Iron (CI) Pipe: Most popular for drainage. Durable for buildings under 25 stories.
- SV Type: Building installation.
- XV Type: Extra duty for underground.
- Styles: Standard (>150,cm), Single Hub (>150,cm), Double Hub (<150,cm), Hubless (uses neoprene sleeves).
- Jointing: Oakum (hemp rope with oil/tar) and molten pig lead (depth of 25.4,mm).
- Acid Resistant CI: Alloy of cast iron and silicon; used in laboratories.
- Asbestos Pipe: Asbestos fibers and Portland cement; same properties as concrete embedding.
- Bituminous Fiber (Orangeburg): Compressed oil-tar pitch and wood fibers. Cheap, flexible, used in the 1950s-60s.
- Vitrified Clay: Highly acid-resistant, brittle, vulnerable to root infiltration. Usually 75,cm lengths.
- Lead Pipe: Anti-corrosive but poisonous; one of the oldest materials.
- Galvanized Steel: Mild steel. Corroded by alkaline/acid; deteriorates faster in hot water.
- Copper Pipe: Highly durable.
- DWV (Yellow): Drain, waste, vent.
- Type K (Green): Heaviest; underground.
- Type L (Blue): Standard for water supply/heating.
- Type M (Red): Thinnest; rigid form only.
- Note: OD is always 1/8 inch larger than standard size.
- Plastic Pipes:
- ABS: High impact, max 71.1circC.
- PVC: Max 60circC. Blue = Potable; Orange/Brown/Gray = Drain.
- CPVC: Max 82.2circC.
- PB: Black, oval, for water service lines.
- PE: Black, circular; not for hot water.
- PPR: High heat/chemical resistance; natural insulation. Max 82.2circC.
Pipe Protection, Hangers, and Supports
- Protection:
- Copper underground must have bitumastic coating, fiberglass wrap, and be inside a split rigid casing.
- Ferrous piping needs more than just zinc coating for outside protection.
- Pipes through walls require metal sleeves.
- Horizontal Pipeline Supports:
- Cast Iron: 1.5,m to 3,m depending on length; connections within 0.45,m of hub.
- Screwed Pipe (IPS): 3,m to 3.6,m.
- Copper Tubing: 1.8,m to 3,m.
- Lead Pipe: Supported entire length with stiff backing.
- Plastic Pipe: 1,m intervals.
- Vertical Pipeline Supports: Generally at every story or floor level.
- Trenching: Bottom of pipe trenches must be at a 45circ angle from the footing of adjacent structures.
- Thrust Blocks: Required at direction changes, size changes, dead ends, and valves where thrust is expected.
Pipe Fittings and Prohibited Connections
- Common Fittings:
- Cap: Closes male end.
- Plug: Male threaded, seals female fitting.
- Union Patente: Unites two pipes, detachable without deformation.
- Reducer: Higher to lower pipe size.
- Double Offset: Two offsets in succession; ends stay in the same straight line.
- Prohibited (RNPCP):
- Double hub in vertical for lead-caulked joints.
- Running threads, bands, or saddles.
- Single/double tee branches in drainage.
- Prohibited (IAPMO):
- Hi-head/Hi-side/Side inlet quarter bends in drainage (allowed in vent).
- Cast iron double hub in drainage.
- Saddle on pipes in drainage/vent.
Plumbing Fixtures and Installation Standards
- Plumbing Unit (Revised Code): 1 Water Meter, 1 Water Closet, 1 Lavatory, 1 Shower/Tub, 1 Kitchen Sink, 1 Laundry Tray, 3 Floor Drains, 4 Faucets.
- Plumbing Unit (NBCDO 2016): 1 Water Closet, 2 Floor drains, 1 Lavatory, 1 Sink, 3 Faucets, 1 Shower head.
- Fixture Unit: Equal to 28.3 liters per minute (1,cu.ft/min).
- Installation Distances:
- Water Closet/Bidet: 0.375,m from center to side wall; 0.75,m center-to-center.
- Urinal: 0.3,m from center to side wall; 0.6,m center-to-center.
- Water Closets:
- Public bowls must be elongated with open-front seats.
- Flushometer valve cannot serve more than one urinal if manually controlled.
- Tanks for multiple urinals must be automatic.
Questions & Discussion
- Question: Refers to a person who is registered and licensed to practice a regulated profession… and holds a valid COR and PIC?
- Answer: b. Master Plumber.
- Question: Which of the following is not within the practice of Plumbing?
- Answer: d. inspection of sewerage system (Note: Sewerage is usually Sanitary Engineering).
- Question: NAMPAP means?
- Answer: National Master Plumbers Association of the Philippines (Note: Variations exist, but context points to b).
- Question: The first Chief of the Division of Plumbing Construction and Inspection?
- Question: Proper protection against contamination by backflow… building drainage system?
- Answer: b. Principle # 9.
- Question: Permit null and void if work not commenced within?
- Question: Also known as Terracotta Pipe?
- Answer: b. Vitrified Clay Pipe.
- Question: Distance of water closet or bidet from center to side?
- Question: Branch interval length corresponds to a story height no less than?
- Question: Type of water closet with highest water demand?