THERAPEUTIC-ULTRASOUND
THERAPEUTIC ULTRASOUND slides
OBJECTIVES
Discuss the role of ultrasound in rehabilitation.
Explain the physiologic effects of ultrasound.
Identify effects of ultrasound on pain relief and tissue healing.
Identify indications and contraindications for ultrasound.
Demonstrate competency in proper, safe, and effective application of ultrasound (lab).
TERMINOLOGY
Compression: Part of the ultrasound wave where particles are pressed closer together.
Rarefaction: Part of the ultrasound wave where particles are spread further apart.
Attenuation: Reduction in the intensity of ultrasound waves as they travel through materials.
Cavitation: The formation of gas-filled bubbles that expand and compress due to pressure changes from ultrasound.
Reflection: Change in direction of ultrasound waves when they bounce off a medium.
Frequency: The number of wave cycles that occur in a given time, measured in Hertz (Hz).
Intensity: The power of ultrasound per unit area, expressed in Watts/cm².
Duty Cycle: The proportion of time that the ultrasound is on versus off, affecting thermal and non-thermal effects.
WHAT IS ULTRASOUND?
Definition: Ultrasound refers to sound energy transmitted in a wave form.
Mechanism: As sound waves exert pressure on a medium, they alternate between compression and rarefaction.
Frequency Range:
- Human hearing: 6 to 20,000 Hz
- Ultrasound operates between 700,000 Hz and 3,300,000 Hz (0.7 to 3.3 MHz).
WAVE PARTS
A. Crest: Point of maximum displacement in the positive direction (measured in meters).
B. Trough: Point of maximum displacement in the negative direction (measured in meters).
C. Amplitude: Maximum displacement from the equilibrium position to either crest or trough (measured in meters).
D. Wavelength: Distance between two consecutive crests or troughs (symbolized as λ).
E. Frequency (f): Number of waves occurring in a specific time period, inversely related to wavelength.
F. Velocity: Speed of sound within a medium, measured in Hz.
ULTRASOUND UNITS
Types of Units:
- Freestanding units
- Tabletop units
- Components:
- Transducer
- Soundhead
- Piezoelectric crystal
PIEZOELECTRIC EFFECT
Definition: The ability of materials to generate electric charge when subjected to mechanical stress or to change shape in response to an electric current.
Examples of Piezoelectric Materials: Quartz, bone, and barium salt.
ATTENUATION
Definition: The absorption of sound waves as they travel through different materials.
Factors Affecting Attenuation:
- Increases with the collagen content in the tissue.
- Increases with the frequency setting.Tissue Attenuation Values (dB/cm):
- Blood: 0.12
- Fat: 0.61
- Nerve: 0.88
- Muscle: 1.2
- Blood vessels: 1.7
- Skin: 2.7
- Tendon: 4.9
- Cartilage: 5.0
- Bone: 13.9
SOUND WAVE INTERACTIONS
Reflection: Happens when ultrasound waves bounce back at the angle of incidence.
Refraction: Change in direction that occurs when waves pass through a material.
Absorption: The conversion of ultrasound energy into heat, accounting for approximately half of attenuation.
COMPRESSION & RAREFACTION
Compression: When particles are approximated.
Rarefaction: When compression is released, leading to increased space between particles.
Equation Representation: Compression <=> Rarefaction = ultrasound wave.
ULTRASOUND WAVES
Transmission: Ultrasound waves cannot transmit through air; they require a medium.
Common Transmission Mediums:
- Ultrasound gel
- Bladders
- Water
THERMAL EFFECTS
Impact on Tissue: Elevates tissue temperature up to 5 cm deep.
Physiological Changes:
- Increases metabolic rate.
- Decreases pain and muscle spasms.
- Alters nerve conduction velocity.
- Increases circulation.
- Enhances soft tissue extensibility.
NONTHERMAL EFFECTS
Uses:
- Promote healing.
- Increase membrane permeability to sodium and calcium.
- Enhance activity in mast cells and fibroblasts.
- Modify inflammation.
- Enable transdermal drug delivery.Thermal Effects: May still occur, especially with pulsed ultrasound using a duty cycle higher than 20%, which might cause up to a 50% thermal effect.
CAVITATION AND MICROSTREAMING
Stable Cavitation: Formation of gas-filled bubbles that expand and compress under ultrasound pressure changes.
Result: Fluid movement, which can help decrease edema without producing thermal effects.
Acoustic Microstreaming: Small microcurrents that flow around the gas bubbles, facilitating the movement of fluid.
CLINICAL APPLICATIONS
Thermal Effects Applications:
- Used to elevate tissue temperature prior to stretching shortened soft tissue.
- Employed for pain reduction.Non-Thermal Effects Applications:
- Enhance membrane permeability.
- Accelerate tissue healing.
KEY CONSIDERATIONS
Parameters for Sound Head:
- Duty Cycle
- Method of Application
- Frequency
- Intensity
- Coupling Medium
- Duration of Application
SOUND HEAD PARAMETERS
Size Variations:
- 10 cm²
- 5 cm²
- 1 cm²Frequency Capabilities:
- Not all sound heads can operate at all frequencies (e.g., 3 MHz or 1 MHz).
INTENSITY
Definitions:
- Spatial-averaged intensity: The average intensity of the ultrasound beam over the entire area of the transducer.
- Spatial peak intensity: The maximum intensity occurring over the transducer.Beam Non-uniformity Ratio (BNR):
- The ratio of peak intensity to average intensity (e.g., 5:1, 6:1).
- A lower BNR is ideal, as it means the peak intensity is closer to the average, limiting variability in the ultrasound beam.
APPLICATION TECHNIQUE
Methods of Application:
Direct Contact:
- Best suited for flat or regular surfaces.
- This is the most common method of application.Water Immersion:
- Used for irregular surfaces and smaller areas.
TECHNIQUE OF APPLICATION
Sound Head Speed: 4 cm/sec – neither too slow nor too fast.
Treatment Area: Should be 2-3 times the Effective Radiating Area (ERA).
Force of Application: Must apply enough pressure to ensure contact for the duration of the treatment.
SOUND HEAD PARAMETERS
Effective Radiating Area (ERA):
- The part of the transducer's surface that effectively produces sound waves.
- Varies with the surface area of the piezoelectric crystal.
- Treatment area should be ideally 2-3 times the ERA.
- Always refer to the user manual for specific ERA.
COUPLING MEDIUMS
Purpose:
- Reduces reflection at the air-tissue interface.
- Acts as a lubricant.Properties:
- Acoustic impedance of the coupling medium matches that of the transducer and is slightly higher than skin.
- Exhibits a low coefficient of absorption to prevent attenuation in the coupling medium.
ACOUSTIC IMPEDANCE
Definition: The product of the density of a material and the speed at which sound travels through that material.
Effects of Impedance: Greater differences in impedance lead to more energy being reflected at the interface, potentially creating standing waves or "hot spots."
CLINICAL APPLICATIONS
Uses of Ultrasound in Therapy:
- Soft tissue healing and repair.
- Addressing scar tissue and joint contracture.
- Stretching connective tissues.
- Treating chronic inflammation and enhancing pain reduction.
- Facilitating bone healing and aiding in the treatment of dermal ulcers.
- Noting the potential for a placebo effect in treatments.
CONTRAINDICATIONS
Conditions where ultrasound should not be applied:
- Malignant tumors.
- Pregnancy.
- Over central nervous system (CNS) tissue.
- Over joint cement.
- Over implanted plastic.
- Pacemaker placement.
- Thrombophlebitis (inflammation of veins).
- Over the eyes and reproductive organs.
PRECAUTIONS
Conditions needing caution while using ultrasound:
- Acute inflammation.
- Healing fractures.
- Over epiphyseal plates.
- Presence of breast implants.
TREATMENT PARAMETERS
Critical Parameters:
- Frequency: in MHz.
- Duty Cycle: continuous or pulsed.
- Intensity: in W/cm².
- Duration: defined time of application.
FREQUENCY
Use of Ultrasound as a Deep Thermal Agent:
- Depth of penetration ranges from 1-5 cm.
- Contrasting effects with MHP (Moist Heat Pack) which primarily heats skin superficially (1-2 mm only).Common Frequencies for Ultrasound:
- 3.3 MHz: (penetrates 1-2 cm).
- 1.0 MHz: (penetrates 2-5 cm).
DUTY CYCLE
Definition: Proportion of the total treatment time that sound waves are emitted from the transducer.
Types of Duty Cycles:
- 100% duty cycle promotes thermal effects.
- Common non-thermal settings are 50% and 20%.
INTENSITY
Thermal Treatment:
- Tissue may take 2-3 minutes to start feeling warmth!
- Recommended intensities:
- 3 MHz (superficial): 0.5 W/cm² – 1.0 W/cm²
- 1 MHz (deeper): 1.5 W/cm² – 2.0 W/cm²Non-Thermal Treatment:
- Objective is tissue healing, not temperature increase.
- Common pulsed settings: 20% (or 50%), at 0.5 W/cm² – 1.0 W/cm².
DURATION
Factors Influencing Duration:
- Size of treatment area, intensity, frequency, thermal vs. non-thermal purpose, and Effective Radiating Area (ERA).General Guidelines:
- Treatment time traditionally recommended as 5-10 minutes for an area twice the size of the ERA.
- Higher frequencies are absorbed 3 times faster than lower frequencies (3 MHz compared to 1 MHz).Adjustments to Duration:
- Increase duration for:
- Lower intensities.
- Lower frequencies.
- Larger areas (>2x ERA).
- Decrease duration for:
- Higher intensities.
- Higher frequencies.
- Smaller areas (<ERA).
SOFT-TISSUE HEALING
Typical Setup:
- 0.5 W/cm², 20% duty cycle for a mix of thermal and non-thermal effects, promoting pro-inflammatory responses.Response in Acute Inflammation: Use non-thermal settings.
Management of Pitting Edema: Continuous 3 MHz ultrasound at 1-1.5 W/cm², as heat helps to liquefy debris.
SCAR & JOINT CONTRACTURE
Recommended Parameters: Continuous ultrasound at 0.5-2.0 W/cm².
Effects of Ultrasound:
- Scar tissue tends to contain disorganized and weaker collagen.
- Increased tissue temperature enhances elasticity and reduces viscosity of collagen fibers, promoting improved mobility for mature scars.
- It is advisable to follow ultrasound with scar massage or manual therapy.
STRETCHING OF CONNECTIVE TISSUE
Effect on Temperature: Increased temperature within collagenous tissues enhances extensibility.
Recommended Practice: Encourage stretching during or immediately after ultrasound treatment for short-term increases in range of motion (ROM).
DETERMINING PARAMETERS BASED ON INJURY TYPE
Acute Injury:
- Intensity: 0.5-1.0 W/cm² (0.8 W/cm² is mid-range).
- Duty Cycle: 20%.
- Duration: 5-8 min.Sub-acute Injury:
- Intensity: 1.0-1.5 W/cm² (1.2 W/cm² is mid-range).
- Duty Cycle: 20% or 50%.
- Duration: 5-8 min.Chronic Injury:
- Intensity: 1.5-2.5 W/cm² (2.0 W/cm² is mid-range).
- Duty Cycle: 100%.
- Duration: 8-10 min.
- Note: Frequency is determined by tissue depth.
PHONOPHORESIS
Description: Transdermal topical drug delivery utilizing ultrasound.
Common Medications Used:
- Ketoprofen (NSAID).
- Cortisol and dexamethasone (steroids).
- Lidocaine (analgesic).
- Gabapentin (anticonvulsant).Treatment Methods: Can be delivered continuously (thermal) or pulsed (non-thermal).
Advantages: Reduces risks associated with injections and oral medications, decreases likelihood of burns compared to iontophoresis.
APPLICATION TECHNIQUE
Assess the patient for appropriateness and safety of ultrasound treatment.
Select the appropriate sound head based on treatment needs.
Turn on the ultrasound machine.
Enter treatment parameters into the machine (select thermal/non-thermal and depth considerations).
Clean the sound head using an alcohol swab.
Apply ultrasound transmission medium to facilitate treatment.
Use direct contact of the sound head with the skin during application.
Start the machine, monitoring patient response throughout the treatment.
At the end of treatment, the timer will indicate the completion.
Clean the skin post-treatment and check for any reactions.
Clean the sound head with an alcohol swab again post-use.
Document the treatment provided.
NOTE ON SAFETY
Important Warning: Powering on the transducer when not in contact with a coupling medium can damage the crystal.