Laboratory safety
Here is a high-yield, exam-focused summary of the Laboratory Safety & Biosafety lecture, organized by the most testable concepts.
1. Hierarchy of Controls
Most Effective \rightarrow Least Effective: Elimination \rightarrow Substitution \rightarrow Engineering Controls \rightarrow Administrative Controls \rightarrow PPE.
Engineering Controls: Physical devices isolating hazards (e.g., Biosafety Cabinets, HEPA filters, sealed centrifuge cups).
Administrative Controls: Policies/protocols changing how people work (e.g., restricting access, training, decontamination rules).
2. Risk Groups vs. Biosafety Levels (BSLs)
Level | Risk Profile (Individual / Community Risk) | Primary Microbes & Examples | Key Containment & PPE Features |
BSL-1 | Low / Low | Non-pathogenic (E. coli K-12, S. cerevisiae) | Open bench work; standard lab coat, gloves, eye protection. |
BSL-2 | Moderate / Low (Treatments available) | Staphylococcus aureus, Salmonella, Hepatitis A/B, Herpes virus | Restricted access; directional airflow; aerosol work done in Class II BSC; eyewash/shower required. |
BSL-3 | High / Low (Respiratory/aerosol hazard; serious/lethal) | M. tuberculosis, Yersinia pestis, SARS-CoV-2, HIV | Negative pressure airflow; double-door entry; back-closing gowns; PAPR/respirator; HEPA-filtered exhaust. |
BSL-4 | High / High (Life-threatening; no vaccine/treatment) | Ebola, Marburg, Lassa virus, Smallpox | Isolated facility; double HEPA exhaust; Positive-Pressure Suits or Class III BSC; chemical shower on exit. |
3. Biosafety Cabinets (BSCs) Classification
Class I: Protects personnel & environment ONLY (no product protection). Unidirectional inflow, HEPA-filtered exhaust.
Class II: Protects personnel, environment, AND product. Uses HEPA-filtered downward laminar airflow + inward inflow. Standard for clinical/diagnostic labs handling BSL-2/BSL-3 agents.
Types: A1/A2 (recirculates air) vs. B1/B2 (ducted exhaust for chemical vapors).
Class III ("Glove Box"): Maximum containment for BSL-4 agents. Gas-tight enclosure with attached heavy gloves; double HEPA-filtered exhaust; materials pass through a pass-box/dunk tank.
4. Decontamination, Sterilization & Chemical Disinfectants
Definitions & Hierarchy
Sterilization: Elimination of all viable biological agents including spores.
Disinfection: Elimination of viable vegetative biological agents (not necessarily spores).
Cleaning: Reduction of biological load.
Autoclaving (Moist Heat — Gold Standard)
Standard Parameters: 121^{\circ}\text{C} at 15 psi.
Autoclave Tape: Changes color/stripes at 121^{\circ}\text{C} to verify heat exposure, but does not confirm time/pressure sterilization.
Biological Indicators: Required for true verification of autoclave effectiveness.
Key Chemical Disinfectants
Bleach (Sodium Hypochlorite / Chlorine): Standard 1:10 dilution (500 ppm); effective against bacteria, viruses, TB, spores; corrosive to metals/electronics.
70–85% Ethanol: Used for equipment/corrosive surfaces; ineffective against spores, HBV, and TB.
Phenolics: Common for benchtop cleaning; effective against TB; ineffective against spores.
Quaternary Ammonium Compounds: Floor cleaning; ineffective against TB, spores, HBV.
Formaldehyde / Glutaraldehyde: Highly effective against spores/TB/HBV, but toxic/carcinogenic (reserved for BSCs or medical instruments in fume hoods).
5. High-Yield Lab Rules & Exposure Management
Sharps: Never recap single-use needles with two hands. If recapping is required, use the one-handed scoop technique. Dispose of in rigid biohazard sharps containers.
Biological Spills: Cover with disinfectant-soaked paper towels, leave for \ge15 minutes contact time before wiping up.
Skin / Eye Exposure: Flush contaminated skin/eyes or cut wounds under running water/eyewash for 15–20 minutes immediately.
Waste Color Coding:
Yellow/Red: Infected waste / Plastics / Soiled material.
White/Blue: Sharps / Cut glass.
Black: Non-infected general waste.
Transporting Biohazards: Primary leak-proof container must be surrounded by absorbent material inside a rigid, unbreakable secondary container labeled with a Biohazard sign.
1. Additional Specific Hazards & Handling
Aerosol Generation: Centrifugation, vortexing, pipetting, and sonicating are the primary sources of laboratory aerosols. Sealed safety cups or rotors must be loaded/unloaded inside a BSC when working with Risk Group 2+ agents.
Centrifuge Safety: If a tube breaks inside a running centrifuge, turn off power immediately, wait 30 minutes for aerosols to settle, then open with proper PPE and clean using a disinfectant like bleach.
Chemical Hazards (GHS Labels): Pictograms for toxic/carcinogenic, flammable, corrosive, explosive, and acute health hazards. Always work in a chemical fume hood (not a BSC) when handling volatile chemical toxins or organic solvents.
Radioactive & Fire Safety: Standard PASS technique for fire extinguishers (Pull, Aim, Squeeze, Sweep) and Class ABC extinguisher usage.
2. Waste Management Specifics
Autoclaving Biohazard Bags: Vent/loosen bags or add water prior to autoclaving to allow steam penetration.
Liquid Waste Treatment: Liquid culture media or blood/body fluids should be autoclaved or treated with bleach (to reach 10% final concentration) for at least 30 minutes before sink disposal (if local regulations allow).
3. Incident Reporting & Post-Exposure Protocol
Order of Operations for Exposure/Needlestick:
1. Immediate First Aid: Wash/flush for 15–20 minutes.
2. Report: Notify lab manager/supervisor immediately.
3. Medical Evaluation: Seek occupational health assessment for post-exposure prophylaxis (PEP) within hours (e.g., HIV PEP, Hepatitis B vaccine/immunoglobulin).