COMD 461- Notes 9/9/26

Hearing Evaluation: Pure Tone and Speech Audiometry

  • Case History (Hx)

    • Interview and/or questionnaires

    • Hearing Loss

    • Tinnitus

    • Dizziness

    • Otalgia

    • Aural fullness

    • Considerations:

      • Use open ended questions, share personal case history — establish relationship

      • Functional impact

      • Onset (When does it start?)/duration/frequency 

  • Otoscopy

    • Examine ear canal

    • Purpose: Examine direction and size of EAC

      • Examine the shape of the ear: small, large, more curvy

    • Determine if testing can be completed

    • Visualize tympanic membrane

      • See ear drums

  • Pure Tone Testing (AC & BC(bone conduction))

    • Purpose:

      • Determine a patient’s threshold

        • Pure tones across the speech frequency rancge

        • Speech threshhold

    • Instruction:

      • “You are gonna hear some beeps. Press the button when you hear the beeps…”

        • Patient’s response to the beeps can vary

          • Press a button

          • Raise your hand

          • Verbal response “yes”

          • For Kids: Stand up or count how many times

      • Time Locked Resposne

        • The patient presses the button right after presentation

  • Diagnostic Audiometer

  • Air Conduction Testing (AC)

    • Specifies degree

  • When Testing a Patient

    • Pateient slightly angles or facing away from window

      • With pediatric patients, may want them facing the window

    • No visual cues

    • False Negative Responses: Ex. Patient misunderstood/forgot the task — hearing worse then they should

    • False Positive Responses: EX. Patient responds to eagerly — tries to predict the sound

  • AC Frequency Testing Order

    • 1000 Hz

    • 250 Hz

    • 500 Hz

    • 1000 Hz re-check (important to check make to give threshold response)

    • 2000 Hz

    • 3000 Hz

    • 4000 Hz

    • 6000 Hz

    • 8000 Hz

  • Interoctaves

    • 3000 Hz & 6000 Hz

      • Usually tested through depends on clinic protocol

    • 750 Hz & 1500 Hz

      • ≥20 dB at adjacent frequencies

    • 125 Hz

      • Vibrotactile — more felt than heard

  • PT Testing Method

    • aka “bracketing”

    • most common method of manual audiometry

PTA (Pure Tone Average)

Bone Conduction Considerations- specifies type

  • Placed on mastoid process behind the ear

    • Placed on forehead on occasion

  • Both ears uncovered

    • Occulusion effect: when an object fills the outer portion of EAC, it causes an increase in the level of sound generated in the EAC by BC

  • BC Testing Frequencies:

    • 500 Hz

    • 1000 Hz

    • 2000 Hz

    • 4000 Hz

Air Conduction — degree of hearing lost


Speech Audiometry

  • Complains about difficulties understanding speech so logical next step is to test hearing function using speech stimuli

  • Degree of hearing loss (HL) for speech

  • Ability to recognize and discriminate sounds of speech


Setup

  • Set up as pure tone testing

  • Diagnostic audiometer

  • Recording or Monitored Live Voice (MLV)

    • Should use pre-recorded material for consistency

    • If running MLV, use VU to make sure own signal stays around 0 VU

  • Monaural or biaural (one or both ears)

    • Headphones, inserts, or sound field speaker

  • Uses diagnostic audiometer

Speech Cognition Threshold (SRT)

  • Lowest hearing level at which speech is barely understood

  • Use spondaic words called spondees

  • Similar threshold searching as pure tone threshhold

    • 50% of list of spondaic words is correctly identified

    • Consider familiarizing list of words for patients before searching for SRT

  • Can be checked relability of pure tones (PT) (SRT vs (PTA)

  • Spondee Words:

SRT Testing Procedure Example:


Speech Detection Threshold (SDT)

  • May not be able to obtain SRT due to language barrier or too difficult of a task for patient to follow even after familiarization

  • SDT: lowest speech level a patient can detect speech

  • SRT Cross Check


    • ± 7 for PTA range


Word Recognition Score (WRS)

  • Percentade of a set of words that a patient accurately reports back

  • Purpose: to obtain a percentage measure that quantifies how clearly speech is heard

  • Score is a percentage (%)

  • Gives us an idea of audibility of speech

  • Words used are monosyllabic and phonetically balanced

  • Commonly used NU-6 word lists or W-22 word lists

    • NU-6 listes preferrable with English speaking adults

  • Instructions: hear sentences


Performance Index (PI) Function


Speech in Noise Test

  • Sentence testing with an increase of of background noise

  • 5 target words per sentence

  • Signal to Noise Ratio: Reflects the relative intensity of the signal (speech) and competing noise


Dynamic Range: “Floor to Ceiling”

  • HTL = softest sound they hear

  • MCL= Comfortable

  • UCL = Highest sound