Colour Vision Testing – Comprehensive Study Notes
Recap – Anomalies of Colour Vision
- Previously studied forms of congenital colour vision deficiency (CVD):
- Anomalous trichromacy – altered spectral sensitivity in one cone class ➜ three cones present but one is spectrally shifted.
- Dichromacy – absence of one cone pigment ➜ only two functional cone types.
- Monochromacy – either only one cone type or none at all (rod monochromacy) ➜ no chromatic discrimination.
- Online practice quiz used: https://quizizz.com/join?gc=224172
Learning Outcomes for Current Lecture
- Explain the function of colour vision tests
- Screening / identification
- Diagnosis / classification
- Assessment / grading
- Describe four test categories
- Pseudo-isochromatic plate (PIC) test
- Arrangement test
- Matching test
- Naming / lantern test
Why Optometrists Test Colour Vision (Overview)
- Occupational physical examinations (e.g. pilots, electricians, drivers, military)
- Diagnosis of hereditary colour anomalies in children & adults
- Disease monitoring for acquired deficiencies (ocular, systemic, drug-induced)
- Four general aims
- Rule out hereditary or acquired CVD
- Detect whether colour discrimination is normal vs. abnormal
- Classify the defect (protan, deutan, tritan; congenital vs. acquired)
- Grade severity
Who Should Be Tested?
- All children (especially boys ⇒ X-linked conditions common)
- Anyone with family history of CVD
- Patients reporting colour confusion symptoms
- Individuals requiring colour-critical occupations
- Cases where ocular/systemic disease, medication, or trauma may produce acquired CVD
Functions of Colour Vision Testing
- Screening
- Rapidly separates normal vs. abnormal (congenital or acquired)
- Diagnosis / Classification
- Identifies specific type (protan, deutan, tritan) & severity
- Assessment
- Evaluates functional impact on career / vocational tasks
Four Main Types of Colour Vision Tests
- Pseudo-isochromatic plate tests (PIC)
- Arrangement tests
- Matching tests
- Naming / lantern tests
1. Pseudo-Isochromatic (PIC) Plate Tests
- Principle: figure & background composed of colours lying on same colour-confusion line for CVD ➜ appear “isochromatic” to affected observer.
- Popular: inexpensive, portable, easy.
- Test task: identify embedded number / shape.
- Common sets
- Ishihara (most widely used; 24- & 38-plate editions)
- Screening only; red-green anomalies; qualitative; fails ≥4 errors (typical).
- Quick subset for time-saving: plates 1,2,3,6,8,10,15,24 (from 38-plate ed.).
- Passes very mild deuteranomalous subjects → false-negatives possible.
- AO Hardy-Rand-Rittler (HRR) plates (not fully described in slides but implied alternative covering tritan lines)
- Standard Pseudoisochromatic Plates (SPP) Vol 1 & Vol 2
- Vol 1: congenital red-green screening similar to Ishihara; includes demo plate detecting tritans.
- Vol 2: designed for acquired defects; includes red-green & blue-yellow patterns.
- Colour Vision Testing Made Easy (CVTME) – child-friendly; red-green only.
- Hahn’s New Colour Test, Lanthony Tritan Album (demo plate), etc.
Plate Construction Categories
- Transformation plates – normals see one figure; CVD sees another.
- Vanishing plates – figure visible to normals only.
- Hidden-digit plates – figure visible to CVD only.
- Diagnostic plates – differential ease allows protan vs. deutan separation.
Limitations of Most PIC Tests
- Primarily red-green; generally do not detect tritanopes (exception: HRR, SPP demo).
- Do not quantify severity (qualitative pass/fail).
- Often cannot distinguish protan vs. deutan (unless diagnostic sets used).
2. Arrangement Tests
- Task: arrange coloured caps / tiles in continuous hue sequence beginning from a fixed reference cap.
- Provide qualitative & quantitative data; can diagnose protan, deutan, tritan and grade severity.
2.1 Farnsworth-Munsell 100-Hue (FM-100)
- Consists of 85 movable caps (originally 100) with equal Munsell value & chroma; divided into 4 trays (caps 85-21, 22-42, 43-63, 64-84) each anchored by fixed endpoints.
- Test type: discrimination (not naming).
- Procedure
- Monocular testing under standard illuminant-C or daylight equivalent (point C on chromaticity diagram).
- Patient arranges each tray; no strict time limit (≈2 min per tray typical).
- Surfaces highly absorbent ⇒ NEVER touch pigment surface.
- Scoring
- For each cap: Score=∣N−L∣+∣N−R∣ where N = cap number, L,R = numbers of adjacent caps in participant’s order.
- Adjust by “minus 2” rule (Farnsworth 1957) to get error score.
- Sum all 85 error scores ⇒ Total Error Score (TES).
- Plot errors on polar coordinate sheet; axes correspond to hue sequence.
- Interpretation
- Lower TES = better discrimination; age-related normal limits (task assigned to students to determine).
- Error axis orientation indicates defect type:
- Protanope: axis ~3 & 9:30 o’clock; mean TES ≈152.
- Deuteranope: axis ~4 & 10 o’clock; mean TES ≈240.
- Tritanope: axis ~12 & 6 o’clock; mean TES ≈202.
- Useful for acquired CVD diagnosis (chloroquine retinopathy, optic atrophies, tobacco-alcohol amblyopia, Stargardt’s, etc.).
- Less helpful for subtle congenital deuteranomaly (may appear normal).
- Drawbacks: expensive, time-consuming.
2.2 Farnsworth D-15 Series
- Abbreviated 15-cap version; two variants
- Saturated (classic)
- Desaturated (Lanthony) – lower chroma, thus more sensitive to mild / acquired defects.
- Advantages: quick, inexpensive, easier scoring.
- Procedure: arrange 15 caps after fixed reference; record sequence on "dot-to-dot" circular sheet based on CIE chromaticity coordinates.
- Scoring / Fail Criteria
- Connect dots; crossings of >2-cap span indicate transposition.
- ≥2 crossings ⇒ Fail (colour defect present).
- 1 crossing ⇒ Borderline ⇒ repeat.
- 0 crossings ⇒ Pass.
- Axis of crossing relative to printed confusion lines indicates protan, deutan, tritan.
- Desaturated D-15 recommended for early acquired disease detection (e.g. glaucoma, macular dystrophy, optic neuropathies).
3. Matching Tests
- Principle: observer adjusts mixture to match reference; analyser records mixture ratio ⇒ quantitative.
- Task: rotate/slide knobs until perceptual match achieved; deviation from normal ratio determines type & severity.
- Examples
- Nagel Anomaloscope (Rayleigh equation R+G↔Y) – gold standard for red-green diagnosis.
- OSCAR & Medmont C-100 (clinical screening versions of anomaloscope concept).
- City University Test (CUT) – pseudo-matching of hue circles.
- Intersociety Color Council Colour Matching Aptitude Test (CAT).
4. Naming / Lantern Tests
- Purpose: simulate real-world signal lights; assess ability to verbally name colours.
- Important for occupational clearance (maritime, aviation, rail, military).
- Subject must correctly name presented light colour pairs.
- Instruments
- Farnsworth Lantern (Fa-LanT)
- Holmes-Wright Lantern (Types A & B)
- Spectrolux Lantern
- Beyne Lantern
- Edridge-Green Lantern (obsolete)
Practical / Ethical / Clinical Considerations
- Always provide proper test illumination (CIE standard illuminant C or D65; ≈6500K; 85 cd/m² for plates).
- Explain test purpose; avoid patient distress; emphasise no “pass/fail” reflection on intelligence.
- Document results clearly in record: test type, eye tested, date, illumination, TES / crossings / plates missed, etc.
- For children, choose age-appropriate tests (CVTME, HRR shapes).
- Occupational judgments should consider specific job standards; severity grading essential.
- Follow-up acquired defects: monitor progression & effect of treatment.
Summary of Today’s Content
- Three key functions of colour vision testing: Screening, Diagnosis, Assessment.
- Four categories of tests with representative examples, strengths & limitations.
- Detailed methodology, scoring, and interpretation for PIC plates and Arrangement tests (FM-100, D-15).
- Recognition of typical error patterns for protan, deutan, tritan, and acquired neuropathies.
- Awareness of illumination requirements, recording conventions, ethical communication, and vocational significance.