Masking Lecture Notes

Well-being Check-in

  • Dedicate time for well-being activities.

  • Engage in hobbies and activities.

  • Commitment to self-care, even small steps are beneficial.

Introduction to Masking

  • Masking is crucial for accurate audiograms, especially in cases of complex hearing loss.

  • The lecture aims to explain: Why, When, What, and How of masking.

Why Masking is Necessary?

  • Sound travels via vibration affecting the tympanic membrane, ossicular chain, and cochlea.

  • Loud sounds can vibrate the entire skull, potentially reaching the non-test ear.

  • Example: Sound presented to a left ear with no hearing can cross over to the right ear if loud enough.

  • The question is: How loud does the sound have to be to cross over and be heard by the non-test ear?

  • This is addressed by understanding interaural attenuation.

Interaural Attenuation

  • Interaural attenuation refers to the amount of sound lost when crossing from one side of the head to the other.

  • The amount varies for each individual due to differences in head size and density.

  • Clinical protocols are based on studies estimating interaural attenuation.

  • Studies show a range of interaural attenuation values across different frequencies.

  • Clinically, the most extreme (minimum) value is used to account for the worst-case scenario of sound crossover.

  • Minimum interaural attenuation for headphones is 40 decibels.

Interaural Attenuation Example:
  • Presenting 90 dB to the test ear:

    • With 40 dB interaural attenuation, 50 dB reaches the non-test cochlea.
      90 dB (presented)−40 dB (attenuation)=50 dB (reaching non-test ear)90 \text{ dB (presented)} - 40 \text{ dB (attenuation)} = 50 \text{ dB (reaching non-test ear)}

    • With 80 dB interaural attenuation, 10 dB reaches the non-test ear.
      90 dB (presented)−80 dB (attenuation)=10 dB (reaching non-test ear)90 \text{ dB (presented)} - 80 \text{ dB (attenuation)} = 10 \text{ dB (reaching non-test ear)}

Masking Defined
  • Masking: Introducing a distracting tone (narrowband noise) to the non-test ear.

  • Narrowband noise is frequency-specific and masks the tone in the non-test ear.

Practical Illustration on Affinity
  • Example scenario is provided with the left ear having no measurable hearing, while the right ear has normal hearing at 0 dB.

  • Without masking, a threshold is obtained in the left ear at 40 dB.

  • This occurs because the 40 dB tone crosses over, losing 40 dB, and is heard by the right ear at 0 dB.

  • The masking procedure is demonstrated using Affinity software to show practical application.

Masking Table Setup
  • Masking tables are crucial for recording masking levels and responses.

  • Key elements include frequency, test ear (the ear receiving the tone), masking transducer (headphones).

  • The masking table has two columns: Masking (dB) and Tone (response).

  • Start with the unmasked threshold before any masking is applied.

  • Masking starts by adding 10 dB of masking to the non-test ear, gradually increasing noise level.

  • If the patient doesn't respond, the tone volume is increased.

  • Responses are recorded in the masking table, noting masking level and tone volume.

Detailed Walkthrough on Affinity
  • The masking side of Affinity is typically red, indicating it's for the right ear.

  • The narrowband noise option is automatically selected for masking.

  • Start with 10 dB of masking, increasing gradually until the non-test ear is effectively masked.

  • If the patient doesn't hear the tone, increase the tone level in 5 dB steps until a response is obtained.

  • The masking table reflects only the levels at which a response is obtained.

  • The presenter clarifies that in masking we do not consider 2 out of 3 responses.

  • Increasing masking noise essentially gives the non-test ear a temporary hearing loss.

Advanced Masking Concepts
  • The tone is increased by 10 dB, then the masking occurs.

  • Further increases in masking with no response lead to higher tone presentations.

  • In cases when you reach 105 dB and can go no further because the equipment wont allow , use the \"N\" function to make a note. Also record as NR105

Scenario: Left Ear Can Hear at 80 dB
  • The speaker adjusts the example to assume the left ear can hear at 80 dB.

  • The masking table is the same, starting with a tone heard at 40 dB without masking.

  • The masking process is reiterated, clarifying whether the response is from the right or left ear.

  • The concept of a \"plateau\" is introduced.

Plateau in Masking
  • Plateau: consistent response across three masking presentations demonstrating sufficient masking.

  • If the left ear can hear, the masking is increased until the left ear begins to respond.

  • Under-masking: Not enough masking, the right ear is still responding.

  • Sufficient masking: The left ear is responding, which is at the plateau.

Additional Masking Concepts
  • 10-for-10 shift: Increase masking by 10 dB, tone moves by 10 dB.

  • It may not be obvious that a plateau has been reached.

  • Increase masking and look for that plateau.

How to Decide Whether Masking Is Required

  • Masking decisions depend on transducers and interaural attenuation.

  • For headphones, the minimum interaural attenuation is 40 dB.

  • For tube phones (insert earphones):

    • 70 dB interaural attenuation for frequencies 1 kHz or less.

    • 50 dB interaural attenuation for frequencies above 1 kHz.

Bone Conduction Masking

  • Minimum interaural attenuation for bone conduction is 0 dB.

  • Sound presented via bone conduction can be heard by both cochleas.

  • Masking for bone conduction is needed to differentiate between conductive and sensorineural hearing loss.

  • Bone conduction is masked if there is a >15 dB gap between air and bone conduction.

Bone Conduction Setup

  • Need to add headphone to test the other ear, if not already in place.

  • Occluded if bone conduction done with the headphone on already

  • Unoccluded if bone conduction done without the headphone on already

  • When you test it unmasked, yes, it will always be what the better cochlear is

Clinical Considerations with Masking

  • There is a risk of over-masking.

  • Bone conduction will always give you the better cochlear thresholds. So you could give the headphone to occlude the ear.

Going Through an Audiogram and Deciding if Masking Is Required

  • Review of how the minimum interaural attenuation will affect the need to apply masking.

  • You can base stuff off of air conductions. The same rule as air conductions will applies using 40 dB rule to better cochlea.

  • If greater than there are greater than a 15 dB difference in air bone gap then we mask for bone conduction.

  • Can interpolate between the air and bone to decide if masking is required.

  • Mask thresholds will always be correct.

Additional Practice and Application

  • Discussion and review of additional exercises on when to mask.