Detailed Notes on Deck Information
Storage and Handling
- Minimum bundle weight for deck: 4,000 pounds.
- Storage: Deck should be stored off the ground.
- Drainage: One end should be elevated for drainage.
- Placement: Deck bundles should be placed along column lines.
- Support: Ends of the bundles should rest on structural supports.
- Working areas: Should be 12 feet wide around deck bundles.
- Placement Method: Always kneel down when placing steel deck.
Load Capacity
- Floor deck: 50 psf capacity for use as a working platform.
- Roof deck: 30 psf capacity.
Deck Laps and Bearing
- Roof deck bearing: Minimum of 1.5 inches (one and one half inches).
- Deck laps: All deck laps should be over supports.
- Attachment points: Ends of each sheet to structural elements, and along the edges to each other.
- Attachment methods: Screws or welds.
- Common screw size: Number 12.
- Welding restriction: Not recommended unless deck thickness is greater than 22 gauge (0.028 inches).
- Well washers: May be used if the deck is less than 22 gauge but NOT for edge welds.
- Edge weld quality: Satisfactory if 75% of the well puddle is attached to steel.
- 6-inch hole: No plate reinforcing required.
- 8-inch hole: Requires a 0.045 inches thick plate.
- 8-inch to 13-inch hole: Requires a 0.057 inches thick plate.
- More than 13-inch holes: Require frame supports.
- Openings up to 24 inches (perpendicular to the deck): Use a C4 by 5.4 channel for support.
Types of Steel Deck
- Composite
- Roof
- Cellular
- Form
Deck Dimensions
- Widths: 12, 18, 24, 30, and 36 inches.
Composite Deck
- Shear connectors: Used to mechanically lock the concrete and deck together.
- Finishes: Galvanized or phosphatized.
- Weight variation: 2 to 4 pounds per square foot.
- Thickness variation: 0.03 to 0.06 inches.
Penetrations and Lapping
- Penetrations: All penetrations in steel deck are made by the trade needing the penetration.
- Roof deck lapping: 2 inches.
Cellular Deck
- Function: Provides chases for wiring.
Roof Deck
- 1x6 WR roof deck: Referred to as B deck.
- 1x6 IR roof deck: Referred to as F deck.
- Minimum thickness for standard form deck: 0.014 inches.