Radiology PowerPoint VT120

Radiology Study Notes

VT120 Introduction to the Applied Sciences

Instructor: Pippa Oval

Part I: X-Rays

History of X-Rays
  • In 1895, Wilhelm Roentgen discovered radiation, originally termed “Roentgenography”.

  • The hazards associated with radiation were not fully understood until later.

Electromagnetic Radiation
  • Definition: Energy that travels in a straight path through space in waves.

  • X-rays are characterized as short wavelength, high energy radiation.

  • Context: X-rays form a part of the electromagnetic spectrum.

Physical Properties of X-Rays
  • Travel Path: X-rays travel in straight lines.

  • Transmission: X-rays can penetrate many materials, resulting in transmitted x-rays.

  • Impact on Matter:

    • As x-rays pass through materials, they collide with electrons.

    • This results in:

      • Scatter Radiation: Change in the path of the x-ray.

      • Excitation: Increase in electron energy.

      • Fluorescence: Certain substances release energy in the form of light.

      • Ionization: Ejection of an outer electron from an atom.

The X-Ray Machine
Basic Components
  • X-Ray Tube:

    • A glass vacuum tube that includes the cathode and anode which produce x-rays.

    • Metal Housing: Protects the glass tube.

    • Oil: Serves as a coolant.

    • Window and Filter: The exit point for x-rays.

Cathode (-)
  • Function: Acts as the electron source.

  • Components:

    • Tungsten filaments, similar to light bulbs but emit electrons instead of light.

    • Focusing cups direct electrons towards the anode.

  • Application: Thicker end of the patient should be positioned at the cathode end of the x-ray tube.

Anode (+)
  • Anode Composition: Made of tungsten metal target.

  • Reactions on Impact:

    • When electrons strike, x-rays are produced (only 1% of the energy) and heat (99% of the energy).

  • Characteristics:

    • Beveled surface for directing x-rays down through the housing window.

    • Incoming wave pattern allows x-rays to fan out from a single point (focal spot).

Types of Anodes
  • Stationary Anode:

    • Made of tungsten target mounted on a stationary copper base.

    • Limited to low energy x-rays and prone to overheating. Often used for dental and portable radiography.

  • Rotating Anode:

    • Target is a rotating disc with beveled edges.

    • Distributes heat across a larger area and can produce higher energy x-rays. Often used for small and large animal radiography.

Collimator
  • Function: Controls the size of the primary x-ray beam, reducing exposure to the patient and personnel.

  • Benefits: Minimizes scatter and improves image quality.

  • Types:

    • Adjustable lead shutters.

    • Lead cones.

Tube Stand
  • Description: Supports the x-ray tube and the collimator.

  • Adjustability: Allows for adjusting tube height and angle, capable of moving left/right along the table.

Cassette Tray and Storage Bin
  • Function: Holds x-ray film cassette under the table.

  • Features:

    • Tray lock aligns tray and x-ray tube.

    • Moves left/right with tube stand and can be unlocked for independent movement.

    • Lead-lined storage bin for loaded cassettes.

Control Panel
  • Features:

    • On/Off switch.

    • Kilovolt selectors.

    • Milliamp (mA) selector.

    • Time selector (not present on newer machines).

    • Exposure foot switch for operation.

Radiation Safety
Hazards of Ionizing Radiation
  • Ionizing radiation can cause damage to rapidly dividing or sensitive cells, including:

    • Hematopoietic and lymphatic tissues.

    • Intestinal epithelium.

    • Gonads.

    • Thyroid.

    • Bone.

    • Skin.

    • Developing embryos.

  • Recommendation: Pregnant technicians should not take radiographs due to risks.

Historical Case Studies
  • Dr. John Hall-Edwards (1897):

    • Exposure led to malignant cancer on his left hand, resulting in amputation.

  • Typical “X-ray Hand” (1904-1913):

    • A technician experienced severe inflammation and cancer progressing rapidly after 6 months of exposure.

Differences between X-rays and Radioactive Radiation
  • X-rays:

    • Produced by electric charges between the cathode and anode.

    • Released only during exposure.

    • Pass through tissues without residual activity.

  • Radioactive Radiation:

    • Produced by gradual breakdown of unstable atoms.

    • Continuously released.

    • X-rays do not induce radioactivity in objects.

Maximum Permissible Dose (MPD)
  • Established by the National Council on Radiation Protection & Measurements (NCRP).

  • Permissible dose for professionals exceeds that of the general public, reflecting regular training and monitoring.

  • Units of measurement: Sieverts or rems, adjusted for biological effects based on different radiation strengths.

  • ALARA Principle: Stands for "As Low As Reasonably Achievable"—strives to maintain exposure rates well below limits.

Exposure Allowances
  • Weekly MPD:

    • 0.001 Sv/week (0.1 rems/week).

  • Quarterly MPD:

    • 0.0125 Sv/quarter (1.25 rems/quarter).

  • Yearly MPD:

    • 0.05 Sv/year (5.0 rems/year).

  • Lifetime Exposure Calculation:

    • Formula: 5(N - 18), where N = current age.

    • Example: For a 50-year-old: 5(50 - 18) = 5(32) = 160 rems maximum.

  • Conversion: 100 rems = 1 Sievert.

Dosimetry
  • Dosimeter: A device for measuring radiation exposure.

  • Film Badge: Most common dosimeter worn at all times during radiography (California law).

  • Reporting: Reports on exposure issued quarterly, including quarterly, annual, and lifetime exposure data.

Radiation Exposure and Safety
  • Primary Beam:

    • Intended to penetrate the patient and produce an image.

    • Safety measure: Filtration—aluminum filters eliminate weak x-rays to prevent tissue damage.

    • Collimation: Required by California law, restricts beam size to necessary dimensions for the radiograph.

  • Secondary Radiation:

    • Also known as scatter radiation, poses exposure risks to patients and technicians.

    • Safety protocol:

    • Limit essential personnel in the area during radiography.

    • Use chemical or mechanical restraints for patients.

    • Maintain distance from the patient when applying manual restraints and always wear protective apparel.

Protective Apparel
  • Lead Lined Apparel: Should have a minimum of 0.5 mm lead equivalent thickness and include:

    • Aprons.

    • Gloves.

    • Thyroid shields.

  • Maintenance:

    • Hang aprons and gloves to dry to prevent cracking.

    • Conduct periodic inspections for damage.

Exposure Factors and Radiographic Quality
mAs (Milliampere-Seconds)
  • Definition: Determines the quantity of x-rays produced per second.

  • Settings for small animal x-ray machines: Typically 100 mA and 300 mA.

  • Calculation:

    • Example: 300 mA x 1/60 second = 5 mAs.

kVp (Kilovolt Peak)
  • Definition: Represents the strength of the x-rays during exposure.

  • Application:

    • Thicker tissues require higher kVp settings.

    • Larger patients also necessitate higher kVp.

kVp vs mAs
  • kVp: Affects the power/strength/quality of the x-ray beam; impacts density and contrast.

  • mA: Refers to the quantity of x-rays produced; quantity affects image density.

  • Time: Longer exposure time results in more emitted x-rays, thereby affecting density.

  • kVp and mAs relationship:

    • mAs = mA x time (seconds).

Distance Considerations
Source-Image Distance (SID)
  • Definition: Distance between any x-ray source and the receptor (film, digital sensor, etc.).

  • Focal Film Distance (FFD): Distance between the anode focal spot and the x-ray film.

  • Standard SID in small animal radiology is typically 40 inches and is marked on the tube stand.

Inverse Square Law
  • The intensity of the x-ray beam is inversely related to the square of the SID:

    • Doubling the distance reduces intensity to 1/4.

    • Halving the distance increases intensity 4-fold.

    • Tripling the distance reduces intensity to 1/9.

Scatter Radiation
  • Definition: Released in random directions and reduces image clarity while exposing patients and technicians to radiation.

  • Factors Increasing Scatter:

    • Large patients.

    • Poor collimation.

    • High kVp settings.

  • Visual Effects:

    • An image with kVp too high may appear entirely black.

Grids
  • Function: Positioned between patient and film to absorb scatter radiation, enhancing image clarity.

  • Composition: Vertical strips of lead or aluminum and spacer material, often mounted under the table and above the cassette tray.

Patient Motion
  • Considerations:

    • Veterinary patients may struggle to stay still, highlighting the need for firm restraint and quick motion during exposure.

    • Motion is typically not detected with exposure times less than 1/30 second (exposure options include 1/120 sec and other fractions).

Distortion in Imaging
  • Concept: The image of an object changes as its position changes.

  • Types of Distortion:

    • Foreshortening: Objects at angles appear shorter.

    • End-on View: Long objects appear as spots.

  • Best Practices: Ensure the body part of interest is parallel to the film.

Tissue Densities
  • Classification:

    • Gas: Least dense (air in lungs, gases in GI tract).

    • Fat: Fat cells filled with lipids.

    • Water: Body fluids (blood, urine, etc.), cytosol, and internal organs.

    • Bone: Most dense.

  • Radiographic Color:

    • Gas: Black.

    • Fat: Dark Gray.

    • Water: Light Gray.

    • Bone: White.

Radiograph Quality
  • Density: Depth of lightness/darkness of the image; controlled by mAs and kVp.

  • Contrast: Degree of difference in shades; controlled solely by kVp.

  • Improvement Techniques:

    • Adjust mAs (increase or decrease) for brightness issues.

    • Adjust kVp (increase or decrease) for contrast issues.

X-ray Film and Film Processing
Cassette
  • Description: A light-proof, rigid case for film, with internal foam backing to flatten film and intensifying screens on each surface.

Intensifying Screens
  • Function: Fluoresce when struck by x-rays, emitting visible light that exposes the film; improves efficiency.

  • Types:

    • Standard screens emit blue light; rare-earth screens emit green light.

Film Anatomy
  • Layers:

    • Protective coat.

    • Emulsion containing silver halide crystals.

    • Base for support.

Film Characteristics
  • Film Speed:

    • Fast Film: Large silver halide crystals, less exposure from x-rays, grainy image.

    • Medium Film: Good balance of speed and quality, commonly used in veterinary practice.

    • Slow Film: Small crystals provide detailed images, requiring more radiation exposure.

Film Identification
  • Requirement: Permanent label including patient name, owner’s name, clinic’s name, and date must be applied during radiography or development.

Film Processing Steps
  1. Developer: Converts exposed silver halide to black metallic silver, revealing the latent image.

  2. Rinse: Removes developer chemicals from film with circulating water.

  3. Fixer: Eliminates unexposed silver halide, hardening the gelatin in the emulsion.

  4. Wash: Circulating water removes fixer chemicals from film.

  5. Dry: Hanging film to air dry.

Film Handling Guidelines
  • Avoid exposing film to white light, store in a light-tight box, and ensure hands are clean and dry when handling film.

  • Load and process only one film at a time to prevent cross-exposure or contamination.

Digital Radiography
  • Definition: Traditional film replaced with digital x-ray image receptors; images are captured on electronic sensors and can be viewed, edited, and stored on a computer.

  • Advantages:

    • Image editing capabilities for brightness and contrast adjustments.

    • Rapid viewing of images with reduced exposure risks for patients and technicians.

    • Digital storage allows easy link to medical records and file transfer.

  • Limitations:

    • Initial equipment costs.

    • Adjustments do not correct issues like patient positioning or collimation errors.

Technique Chart
  • Purpose: Provides proper exposure factors based on body part thickness in cm, including kVp, mA, and seconds to reduce retakes.

  • Use Guidelines: Determines exposure factors vary with film-screen systems, tissue density, desired contrast, and the use of grids.

  • Technique Chart Development:

    • Use a mid-sized patient for trials.

    • Adjust kVp and mAs based on trial outcomes per patient size adjustments.

Technical Artifacts and Errors in Film X-rays
  • Common Errors:

    • Black cloudy edges due to film exposure to white light.

    • Fingerprints from handling with contaminated hands.

    • Double exposure and underexposure resulting in unclear images.

    • Overlapping images from incorrect processing leading to chemical trapping.

Conclusion
  • Careful handling and adherence to protocols is essential to ensure x-ray quality and safety for both patients and technicians.

Questions Or Discussion Points?