Unit 7
Objectives:
identify the 4 functions of the anesthetic machine.
list the main components of an anesthetic machine.
describe the various gas cylinder types and the gases they can contain.
become aware of oxygen tank safety procedures.
describe the functions of the oxygen tank, pressure gauge, line gauge, pressure reducing valves and the flowmeter.
describe oxygen flow rates.
perform calculations relating to oxygen flow rates and oxygen tank pressure.
state the function of the vaporizer.
explain how oxygen flows through the vaporizer.
describe how to turn on/off the vaporizer.
explain what VOC is in relation to a vaporizer.
list the functions of the rebreathing bag.
list the uses for a rebreathing bag.
define IPPV and list its benefits.
calculate breathing bag sizes.
explain what a manometer is and how to read it.
explain the function of the pop-off valve, CO2 canister, flutter valves, negative pressure valve and the oxygen flush valve.
identify the types of breathing hoses used.
list the 2 types of breathing systems on the anesthetic machine.
explain the rebreathing system, how the system works and list the 2 types.
list all the parts of the rebreathing system.
identify the 2 types of breathing hoses used on the rebreathing system.
explain the non-rebreathing system and identify the most common type of this system.
identify the breathing hose used for this system.
explain what the exhaust valve is and describe its function.
list the advantages and disadvantages of each breathing system.
list the oxygen flow rates for each system.
identify the 3 types of exhaust systems.
describe the steps involved in checking for leaks within each system.
list the common areas where leaks occur.
identify which animals require a large animal anesthetic machine and what specialized equipment is needed for horses.
The document explains how veterinary anesthetic machines safely deliver oxygen and inhalant anesthetic, manage exhaled gases, and support patient ventilation.
Core functions and components
Four core functions: deliver controlled oxygen; vaporize and mix liquid anesthetic with oxygen; remove or recycle exhaled gases while removing CO2; and provide pure oxygen when needed.
Main components: compressed-gas supply, vaporizer, breathing circuit, and scavenging/exhaust system.
Oxygen demand increases under anesthesia because patients breathe more shallowly and take in less oxygen per breath.
Oxygen supply and safety
Cylinder types: small E cylinders attach to the machine; larger G/H cylinders are freestanding, secured to a wall or cart, and connected by gas lines.
Safety: move cylinders only on carts, chain large cylinders securely, and keep ignition sources away because 100% oxygen supports combustion.
Pressure: a full oxygen cylinder is about 2,200 psi (15,000 kPa). Replace it below 500 psi (3,400 kPa).
Pressure regulation: the reducing valve lowers cylinder pressure to about 50 psi to protect the machine and patient; the flowmeter further controls delivery flow.
Tank calculations:
E cylinder oxygen volume = pressure in psi × 0.3.
H cylinder oxygen volume = pressure in psi × 3.
Duration = available oxygen volume ÷ flow rate.
Example: an E cylinder at 600 psi contains 180 L; at 3 L/min, it lasts about 60 minutes.
Vaporizer and breathing bag
Vaporizer: converts liquid anesthetic into vapor and adds a precise percentage to the oxygen flow. Vaporizers are agent-specific and use keyed, color-coded filling systems to prevent the wrong drug being added.
Reservoir bag: stores fresh gas, visibly reflects respiration, helps confirm endotracheal tube placement, and permits manual ventilation.
IPPV (“bagging”): gently inflates the lungs to deliver oxygen/anesthetic and reduce atelectasis. Do not exceed 15–20 cm H2O.
Bag sizing: tidal volume is approximately 10 mL/kg; reservoir bag size is 6 × tidal volume, or about 60 mL/kg. Select the next larger available bag size.
Pressure control and CO2 removal
Manometer: monitors circuit pressure. Keep pressure below 20 cm H2O during manual ventilation and below 2 cm H2O when not bagging; excessive pressure can damage alveoli.
Pop-off valve: releases excess gas and prevents pressure buildup. It must be closed while bagging, then reopened immediately afterward.
CO2 canister: soda lime or barium lime absorbs CO2 in rebreathing systems and generates heat and water. Replace absorbent after 8 hours of use or 30 days; color change can indicate saturation but may reverse over time.
Flutter valves: one-way valves that direct inspiratory and expiratory flow; their movement can help monitor respiratory rate.
Negative-pressure relief valve: admits room air if a vacuum develops, such as when oxygen runs out; a collapsed reservoir bag signals negative pressure.
Oxygen flush valve: delivers 35–75 L/min of pure oxygen directly into a rebreathing circuit, bypassing the flowmeter and vaporizer.
Breathing systems
Rebreathing/circle system: for patients over 7 kg. Exhaled gas is recycled after CO2 removal. It uses lower oxygen flows, preserves warmth and humidity, costs less, and reduces waste-gas exposure. Its drawback is slower changes in anesthetic depth.
Non-rebreathing/Bain system: commonly used for patients under 7 kg, though it can be used for larger animals at adequate flows. Exhaled gas is not recycled, so anesthetic-depth changes occur quickly. It requires higher oxygen and anesthetic use, produces cooler/drier gas, and can increase personnel exposure to waste gas.
Typical flow rates:
Rebreathing: 50 mL/kg/min.
Bain/non-rebreathing: 200 mL/kg/min; for animals 7 kg or less, at least 1.5 L/min is specified.
Scavenging, leak testing, and large animals
Exhaust systems: passive outdoor venting, activated-charcoal canisters, or active fan-assisted exhaust. Active systems are the most efficient and safer for personnel.
Leak testing: perform before every use. Close the pop-off valve, occlude the patient end, pressurize to 30 cm H2O for 10 seconds, and confirm that both pressure and bag volume remain stable. Common leak points are the reservoir bag attachment, circuit, and pop-off valve.
Large animals: animals over about 200 lb generally require a large-animal machine; horses under inhalant anesthesia also require a ventilator to maintain adequate tidal volume.
Overall, safe anesthesia depends on correctly supplying oxygen, selecting the appropriate circuit and flow rate, controlling pressure, absorbing CO2, scavenging waste gas, and checking the machine for leaks before use.
What are the four essential functions of an anesthetic machine?
What are the four main components of an anesthetic machine?
What carrier gas is usually used to deliver volatile anesthetic?
Why do anesthetized patients require a continual oxygen supply?
Why do anesthetized patients have a higher oxygen requirement than awake patients?
Oxygen cylinders and safety
What is an E oxygen cylinder, and where is it mounted?
What are G and H oxygen cylinders, and how are they connected to the machine?
How should large oxygen cylinders be stored or secured?
How should oxygen cylinders be moved safely?
Why is smoking prohibited near oxygen cylinders?
What colors identify oxygen cylinders in Canada/Europe and in the United States?
In which direction is an oxygen tank valve turned to open it?
What does the oxygen tank pressure gauge measure?
What units are used to measure oxygen tank pressure?
What pressure indicates a full oxygen cylinder?
At what pressure should an oxygen cylinder be replaced?
What is the purpose of a pressure-reducing valve?
To approximately what pressure does the pressure-reducing valve lower tank pressure?
What is line pressure?
How can gas remaining in the lines be purged or flushed?
Flowmeter and oxygen calculations
What is the function of the oxygen flowmeter?
At what point on a flowmeter ball should the oxygen flow be read?
At what point on a flowmeter bobbin should the oxygen flow be read?
In what units are oxygen flow rates expressed?
What factors determine the appropriate oxygen flow rate?
How do you calculate the oxygen volume in an E cylinder?
How do you calculate the oxygen volume in an H cylinder?
How much oxygen is in a full E cylinder at 2,200 psi?
How much oxygen is in a full H cylinder at 2,200 psi?
How much oxygen is in an E cylinder at 500 psi?
How much oxygen is in an H cylinder at 1,650 psi?
How much oxygen is in an E cylinder at 600 psi?
How do you calculate how long an oxygen tank will last?
How long will an E cylinder at 600 psi last at an oxygen flow of 3 L/min?
Approximately how long will a full E cylinder last at 1 L/min?
What is the pressure of a full nitrous oxide cylinder?
Vaporizer
What are the two main functions of an anesthetic vaporizer?
How does oxygen travel through and pick up anesthetic from the vaporizer?
What does the vaporizer control dial do?
What is meant by a precision vaporizer?
Why is each vaporizer specific to one anesthetic agent?
What does “VOC” mean in relation to a vaporizer?
What safety features prevent the wrong anesthetic agent from being added to a vaporizer?
What color coding is used for isoflurane, sevoflurane, and desflurane vaporizers?
What is “fresh gas” after it leaves the vaporizer?
Reservoir bag and manual ventilation
What are the functions of the reservoir bag?
How can the reservoir bag help monitor a patient’s respiration?
How can reservoir bag movement help confirm endotracheal tube placement?
What is IPPV?
What is another term for IPPV?
What are the benefits of manual ventilation or bagging?
How does IPPV help prevent atelectasis?
What is tidal volume?
What is the standard tidal-volume estimate for an anesthetized patient?
What is the formula for calculating reservoir bag size in mL using body weight in kg?
What is the alternate reservoir bag calculation using body weight in pounds?
How is the final reservoir bag selected after calculating the minimum size?
What reservoir bag size would be selected for a 10 kg dog?
What reservoir bag size would be selected for a 3.2 kg cat?
What reservoir bag size would be selected for a 35 kg dog?
What does a consistently empty reservoir bag indicate?
Pressure control and circuit valves
What does a pressure manometer measure?
In what units is manometer pressure measured?
What is the maximum safe circuit pressure during bagging?
What should the circuit pressure be when the patient is not being bagged?
What can happen if excessive pressure is delivered to the lungs?
What is the purpose of the pop-off valve?
When should the pop-off valve be fully open?
When should the pop-off valve be closed?
Why must the pop-off valve be reopened immediately after bagging?
What are the main types of pop-off or exhaust valves?
What is the function of flutter valves?
How can flutter valve movement be used during anesthesia monitoring?
What is the function of the negative-pressure relief valve?
What may cause negative pressure within the circuit?
What does a collapsed reservoir bag indicate?
What is the oxygen flush valve?
What oxygen flow rate can the oxygen flush valve deliver?
What machine components does the oxygen flush valve bypass?
What are the uses of the oxygen flush valve?
Why is the oxygen flush valve usually not connected to a Bain system?
CO2 absorption
What chemicals may be used in a CO2 absorber canister?
What is the main function of the CO2 canister?
What products are created when soda lime absorbs carbon dioxide?
Why does a functioning CO2 canister become warm?
How can fresh and exhausted soda lime granules be distinguished physically?
How often should CO2 absorbent be replaced?
What color change can indicate that soda lime is saturated?
Why should soda lime color change not be the only indicator of saturation?
Breathing systems
What are the two major types of anesthetic breathing systems?
What does a breathing system carry to and from the patient?
What is another name for a rebreathing system?
How does a rebreathing system manage exhaled anesthetic gas and CO2?
What patient size is generally appropriate for a rebreathing system?
What is the difference between a closed and a semi-closed rebreathing system?
What components are included in a rebreathing system?
What is the difference between Y-breathing tubes and a universal F-circuit?
Which side of a rebreathing circuit should be closest to the reservoir bag?
What is another name for a non-rebreathing system?
What patient size is commonly suited to a non-rebreathing system?
What is the most common non-rebreathing circuit type?
How does a Bain system route inhaled and exhaled gas?
Which components are absent from a Bain/non-rebreathing system?
What prevents rebreathing of CO2 in a non-rebreathing system?
What is the minimum oxygen flow rate for a Bain system in patients 7 kg or less?
Comparing systems and flow rates
What are the advantages of a rebreathing system?
Why is a rebreathing system more economical than a non-rebreathing system?
Why do rebreathing systems help conserve warmth and humidity?
What are the disadvantages of a rebreathing system?
Why do anesthetic-depth changes occur more slowly in a rebreathing system?
What are the advantages of a non-rebreathing system?
Why do anesthetic-depth changes occur more quickly in a Bain system?
What are the disadvantages of a non-rebreathing system?
Why can non-rebreathing systems increase waste-gas exposure for personnel?
What oxygen flow rate is used for a rebreathing/circle system?
What oxygen flow rate is used for a Bain/non-rebreathing system?
Scavenging, leak testing, and large animals
What are the three types of anesthetic waste-gas exhaust systems?
How does a passive exhaust system remove waste anesthetic gas?
What are the disadvantages of a passive exhaust system?
How does an activated-charcoal scavenging system work?
Where is a charcoal canister attached in a rebreathing system?
Where is a charcoal canister attached in a non-rebreathing system?
How often should an F-Air charcoal canister be changed?
What must be kept uncovered on an F-Air canister, and why?
How does an active exhaust system remove waste anesthetic gases?
Why is active exhaust safer and more effective than passive exhaust?
How long should an active exhaust system remain on after surgery?
Why should the anesthetic machine be leak-tested before every use?
What are the three most common areas for anesthetic machine leaks?
What are the steps for leak-testing a rebreathing circuit?
What are the steps for leak-testing a Bain circuit?
During a leak test, what pressure should the system hold and for how long?
What indicates that a breathing system has passed a leak test?
Which animals generally require a large-animal anesthetic machine?
What additional equipment do horses require during inhalant anesthesia?
Why do horses under inhalant anesthesia require a ventilator?