Positive Pressure Ventilation Standard Operating Procedure
Objective and Equipment for Positive Pressure Ventilation (PPV)
Objective: To facilitate the rapid and systematic removal of smoke and gases from structures during firefighting operations by utilizing the concepts of positive pressure ventilation.
Required Equipment:
Gas Powered Positive Pressure Fan: Must be a 21" Power Blower with a 4-cycle engine, capable of an output of .
Electric Powered Smoke Ejectors: Available in sizes of 16", 20", and 24".
Applicable Structures for PPV
Positive Pressure Ventilation may be utilized on a diverse range of structures, including but not limited to:
Single and Multiple Family Dwellings.
Apartment Buildings.
Hi-Rise Buildings.
Malls.
Windowless Buildings.
Basements.
Attics.
Strip Stores.
General Information and Tactical Principles
Strategic Application: PPV is an additional tactic for the Company Commander to consider and is most successful when used on confined space fires. It is not applicable to every fireground incident.
Personnel and Roles:
A fireground ventilation officer should be established during initial suppression operations. This individual must be familiar with PPV principles and practices.
Ventilation is most effective when exactly ONE firefighter and the Officer in Charge (OIC) implement and control the operation.
Effective communication is paramount for implementation.
Regulation of Airflow:
The size of the discharge opening must be regulated to control interior pressure. High interior pressure increases the speed of smoke removal.
Methods to control discharge size include using only the top portion of a window or opening a sliding/overhead door only of the way.
Wind Direction: Pressurization should occur from the windward side, with exhaust directed to the leeward side, particularly on windy days.
Operational Setup and Fan Placement:
Multiple Fans: Fans can be used in series (pressure mode) or parallel (volume mode).
Mixed Sizes: If using fans of different sizes, place the larger fan in front of the smaller fan to utilize its higher output. The smaller fan behind it maintains the seal.
Exact Placement Distances: The front fan is placed from the opening. The back fan is placed away to maintain the cone seal.
Removal of Obstructions: Screens must be removed from windows to increase airflow by . Curtains should be removed or tied back.
Safety Constraints:
PPV is NOT to be used in suspected backdraft situations.
Large loading dock doors should be closed halfway ( way) to reduce the opening size.
Timing: Ventilation must not start until personnel are ready to attack the fire within approximately , ensuring an exhaust opening exists before starting the blower.
Specific Applications: Dwellings and Basements
Single Family Dwellings (One Story):
Place fan from the door to seal the opening in a "cone" fashion. Proper placement is verified by feeling for airflow around the opening with a bare hand.
Establish a single pathway using a single discharge opening (door or window) on the opposite side of the structure to follow natural airflow.
Compartmentalization: If many windows are removed during suppression, PPV is achieved by opening and closing individual doors to isolate rooms.
Single Family Dwellings (Multiple Stories):
Clear the first floor first while keeping upper floor openings closed.
Once the first floor is clear, close its discharge opening to force air upward into the second floor.
Basements (No Exterior Openings):
Requires two fans. Position a 16" electric fan at the top of the stairs blowing down to avoid introducing carbon monoxide fumes from gasoline fans.
The electric fan should NOT seal the opening; place it close to the door to force air through the bottom half () of the doorway while smoke exits the top half ().
The second fan pressurizes the rest of the building as usual, moving air across the basement entrance toward a discharge opening on the opposite side of the structure.
Basements (Existing Openings):
Close the opening between the basement and the first floor to prevent smoke spread.
Pressurize the area using the same procedure as dwellings. A fan can be placed at the basement opening on the floor above.
Mechanical Warning: 4-cycle PPV blowers must not be laid horizontal, as the oil will fail to lubricate the engine.
Specific Applications: Attics, Strip Stores, and Large Structures
Attics:
Clear the area of the building most likely to receive smoke damage before opening attic hatches or doors.
Seal the entrance in a cone fashion. Use existing louvers, turbines, or cut a ventilation hole in the roof.
Monitor roof operations closely during fire attack.
Strip Stores:
Follow single-story dwelling guidelines.
Exhaust the farthest occupancy where smoke is entering. Once clear, close the discharge opening to limit spread and move to adjacent occupancies.
Check void spaces above drop ceilings for fire extension.
Multi-Story, High-Rise, and Windowless Buildings:
Identify an enclosed stairwell with roof access. If smoke is present, send a firefighter equipped with SCBA, a spare bottle, and a portable radio to the top, closing all doors on the way up.
Pressurize in series: First fan from door, second fan in front of the first.
Ventilate floors from the lowest involved floor upward.
Chimney Effect: One stairwell provides fresh air while another (with roof access) serves as a "chimney" to exhaust gases. Elevator shafts may also be used if roof and floor access are present.
Smokeproof Enclosure Ventilation Systems:
Common in new High-Rise and Mid-Rise construction. These are independent systems activated by smoke detectors at stairwell entrances.
These shafts have dampered relief openings and supply a minimum positive pressure of through the relief opening while maintaining stairwell pressure.
Command Actions: The Company Commander must find the annunciator panel (usually near the main entrance) and activate the stairwell pressurization system. If using the stairwell for smoke removal from a specific floor, the exhaust system must be shut off to avoid "fighting" the system.
Height Considerations: In buildings over 15 stories, an additional fan may be required in the intake stairwell at the level being cleared.
Apartment Complexes, Malls, and Aircraft
Apartment Complexes:
Open Stairwells: Fan placed outside the main entrance to maintain access/egress.
Enclosed Stairwells: Discharge options include exhausting through an involved or uninvolved apartment, removing glass at the uppermost landing (use extreme caution), or cutting a roof hole above the stairwell scuttle hatch.
Malls:
Individual stores are treated like strip stores. Large areas require a single opening/discharge point with multiple fans (in-line or parallel) and booster fans inside.
Internal HVAC equipment may be used, though caution is required regarding heat and smoke spread.
Aircraft Emergencies:
Position fans at entry points: front passenger entrance, over-wing emergency exits, or rear food service entrances.
For high/hard-to-reach points, hang the fan on an "A" frame ladder or place it on a mobile stairwell to move it into position.