Surgical Instruments Cleaning and Care
Core Terminology & Aseptic Principles
- Pathogen: Microorganisms capable of causing disease or destruction within the body. Microorganisms include viruses, bacteria, parasites, fungi, and yeasts.
- Infection: A condition where pathogens become established and replicate within host tissue.
- Disinfectant: Chemical agents applied to inanimate (non-living) objects that destroy some viruses and bacteria, but not bacterial spores (such as Mycobacterium tuberculosis).
- 5 Traits of an Ideal Disinfectant:
- Broad Spectrum
- Non-Irritating
- Non-Toxic
- Non-Corrosive
- Inexpensive
- 5 Traits of an Ideal Disinfectant:
- Antiseptic: Chemical agents applied to living tissue to destroy bacteria and some viruses (does not destroy spores).
- Asepsis: Freedom from infection or sepsis; the complete absence of pathogenic microorganisms that cause infection.
- Aseptic Technique: All precautions taken to prevent contamination of a surgical site by infectious agents, forming the basis of surgical preparation.
- Sterilization: The complete destruction of all living microorganisms, including pathogenic bacteria and bacterial spores.
- Contamination: The introduction of pathogens into a sterile surgical area or wound.
Surgical Instruments: Quality, Finishes, and Function
- Instrument Quality & Metallurgy:
- Surgical instruments range in price from to per instrument depending on steel quality.
- Higher-quality instruments are manufactured from high-grade stainless steel.
- Lower-quality instruments use lesser-grade metals or chrome plating. Although lower-quality instruments can be cleaned and sterilized alongside high-quality ones, they tend to rust over time. This rust can physically transfer to and damage surrounding high-quality instruments during sterilization cycles.
- Instrument Finishes:
- Satin Finish: Matte surface finish. Preferred in surgery because it significantly reduces light glare from overhead operating lamps. However, satin finishes are less resistant to spotting and discoloration, requiring rigorous cleaning.
- Shiny / Mirror Finish: Highly polished surface. Reflects bright lights (causing glare), but offers greater resistance to spotting and surface staining.
- Functionality Inspection Checklist:
- Visual Cleanliness: Confirm all surfaces are visibly clean and completely free of tissue, debris, and stains.
- Scissors: Blades must glide smoothly across their entire length without binding or looseness when closed.
- Forceps: Tips must align precisely when pressed together.
- Hemostats & Needle Holders: No light should be visible between closed jaws. Ratchets must lock and unlock smoothly without jamming, and joints must not be loose.
- Needle Holder Jaws: Inspect tungsten carbide inserts or jaw serrations for signs of flattening or wear.
- Cutting Instruments & Scalpel Handles: Check that blades are sharp, unnotched, and undamaged.
Causes and Identification of Corrosion
- Primary Causes of Instrument Damage:
- Pitting, staining, and discoloration are primarily caused by blood, tissue, and surgical residue.
- Water and moisture allowed to dry on instrument surfaces accelerate corrosive damage.
- Differentiating Rust vs. Stain (The Eraser Test):
- Stains represent surface discoloration that can be removed, whereas rust/corrosion causes permanent pitting and structural breakdown of the metal.
- Eraser Test Procedure: Rub a soft pencil eraser firmly over the orange or brown discoloration.
- Stain: Discoloration wipes away completely, leaving the underlying metal smooth and clean.
- Rust/Corrosion: Discoloration clears to reveal a microscopic pit mark or etched depression in the metal surface.

- Specific Causes of Corrosion & Marking:
- Surgical Residue: Blood, pus, and body fluids contain high concentrations of chloride ions. Chloride ions cause rapid pitting corrosion, which typically appears as an orange/brown discoloration. Allowing organic matter to sit for extended periods () causes severe staining. Baking dried organic debris onto steel inside an autoclave at () causes permanent corrosive pitting.
- Tap Water Minerals: Tap water contains heavy mineral deposits (calcium, magnesium, iron) that form fine chalky or spotty deposits on metal. Water with high mineral content left to evaporate on instruments causes permanent staining. Distilled water must be used for all rinsing and soaking steps following initial manual washing.
- Inappropriate Cleansers: Never use dish soap, laundry detergent, or surgeon hand scrubs to clean instruments. These products alter surface pH and leave films that cause severe spotting and corrosion. Only use neutral-pH, approved instrument cleaning formulas.
Surgical Instrument Cleaning & Maintenance Protocols
Pre-Soak & Enzymatic Cleaners:
- Instruments must be placed in pre-soak enzymatic cleaners immediately after surgical use before manual scrubbing (e.g., Metri-Clean2, Instra-Clean).
- Enzymatic formulas break down organic debris without mechanical friction. They remove a large majority of surface contamination.
- Key Components of Enzymatic Cleaners:
- Surfactant: Detergent that lowers water surface tension to penetrate micro-crevices.
- Enzymes: Proteolytic compounds that enzymatically digest proteins found in blood, tissue, and mucus.
Ultrasonic Cleaning:
- Uses high-frequency sound waves (cavitation) to generate microscopic bubbles that implode, dislodging soil from hard-to-reach areas.
- Ultrasonic cleaning is more efficient than manual hand scrubbing.
- Ultrasonic Cleaning Rules:
- Manually clean all visible debris off instruments prior to ultrasonic placement.
- Process instruments in the ultrasonic unit for (or per standard hospital protocol).
- Do not overload the basket; ensure space between instruments for sound wave penetration.
- Open all instrument ratchets and box locks fully.
- Rinse instruments in distilled water immediately upon removal.
Instrument Lubricants ("Instrument Milk"):
- Products such as Metri-Lube act as an anti-corrosive barrier and maintain hinge mobility.
- Immerse instruments in diluted lubricant for immediately after cleaning/rinsing.
- DO NOT rinse or wash instruments after lubrication.
- Allow instruments to air dry completely on paper towels.
Cold Sterilization & Chemical Disinfection:
- Refers to soaking instruments in a liquid chemical disinfectant solution for an extended period.
- Used strictly for non-sterile or minor procedures (e.g., abscess care, dental work).
- Disinfection occurs within . Instruments should never remain in soaking solutions longer than , as prolonged immersion damages metal.
- Cold sterilization is not an accepted method for full surgical sterilization. Items requiring true sterility must be autoclaved.
- Glutaraldehyde:
- A potent chemical disinfectant capable of killing all vegetative microbes and bacterial spores given sufficient contact time.
- Toxicity Warning: Glutaraldehyde vapor is highly toxic, causing severe irritation to eyes, nose, throat, and lungs, as well as headaches, drowsiness, and dizziness. It is a major cause of occupational asthma among healthcare workers.
Standard Hospital Instrument Cleaning Protocol (Lakeland College Animal Hospital):
- Place all used surgical instruments into diluted Metri-Clean2 pre-soak solution immediately.
- Allow instruments to soak for a minimum of .
- Carefully scrub all instrument surfaces, serrations, and hinges using a nail/instrument brush under running tap water.
- Rinse instruments thoroughly.
- Discard dirty pre-soak solution and rinse the wash container.
- Place scrubbed instruments into the Ultrasonic Cleaner filled with fresh Metri-Clean2 solution for .
- Remove instruments and rinse thoroughly in distilled water.
- Submerge all instruments in diluted Metri-Lube (lubricant/anti-corrosive) for .
- Funnel remaining Metri-Lube solution back into its storage jug (reusable).
- Spread instruments out open on paper towels and allow to air dry.
- Sterilize or store in designated drawers by the following morning.
Methods of Sterilization
- Physical & Chemical Sterilization Modalities:
- Filtration: Traps and removes microorganisms and particulate matter from liquids or gases through micro-porous membranes. Used primarily for heat-labile pharmaceuticals.
- Radiation: Employs radiant energy (gamma rays or electron beams) to destroy cellular DNA without generating significant thermal heat. Used industrially for pre-packaged suture material, latex surgical gloves, and single-use plastic catheters.
- Gas Sterilization: Employs Ethylene Oxide (EtO) gas. Highly effective for heat- and moisture-sensitive items such as delicate plastics and rubber. Requires specialized aeration equipment due to severe toxicity and mutagenicity.
- Plasma Sterilization: Low-temperature sterilization utilizing vaporized hydrogen peroxide () activated into a plasma state. Vapor is converted into harmless water () and oxygen () at cycle end. Kills all microbes and spores. Features a rapid cycle time () and low power consumption.
- Thermal Heat / Steam Sterilization: Destroys microorganisms via thermal protein denaturation. Microbe death depends on temperature, pressure, and exposure duration. Boiling water () acts only as a disinfectant and does not achieve sterilization because it cannot destroy bacterial endospores.
Autoclave Mechanics & Operation
- Autoclave Principles:
- Steam under pressure is the most common, efficient, and reliable sterilization method (Gravity Air-Displacement Sterilizer).
- Pressurizing the chamber elevates steam temperature above standard atmospheric boiling point.
- Autoclave Cycle Steps:
- Distilled water enters the bottom chamber reservoir and is heated electrically.
- Water converts to steam, which expands and forces room air out through an exhaust port.
- Once air is purged, the exhaust valve closes and steam pressure builds until target operating temperature is reached.
- At cycle completion, temperature drops, pressure releases, and steam condenses back into water to drain.
- Sterilization Parameters:
- Temperature: Must reach (). Standard target is ().
- Pressure: Must reach (pounds per square inch).
- Sterilization Exposure Time: Must maintain target temperature and pressure for (average exposure is , excluding warm-up and drying phases).

- Tuttnauer Automatic Autoclave Operating Sequence:
- Remove reservoir cover and verify water level; water must reach the base of the safety valve.
- Load prepared packs into the chamber.
- Power unit on using the green toggle switch.
- Close chamber door and rotate handle tightly until the "Close Door" light illuminates.
- Select the pack program button (Gowns, Drapes & Instruments icon).
- Press the "Start" button (chamber fills automatically).
- Autoclave automatically executes: Heating Sterilizing Exhausting Drying.
- Cycle end is signalled by a buzzer; "Start" light turns off.
- Open door, remove packs, and transfer to storage cupboards.
- Rest Period: A minimum of is required between consecutive autoclave runs to prevent system overheating.
- Drying Phase & Prevention of Strike-Through:
- Upon cycle completion, the autoclave door must be cracked open for to allow residual steam to vent.
- Strike-Through: Opening a wet pack or failing to vent moisture allows environmental bacteria to "wick" or migrate through damp wrap material directly onto internal contents, completely destroying pack sterility.
- Loading Guidelines:
- Do not overload the chamber. Leave of space between individual packs and chamber walls.
- Place packs vertically (on edge) rather than stacking them horizontally to allow free steam circulation.
- Sterilize hinged instruments with ratchets open (except towel clamps and scissors).
- Use extra rinse cycles when laundering fabric drapes/towels. Residual laundry detergent vaporizes during autoclaving and deposits onto instrument surfaces.
- Autoclave Maintenance:
- Autoclaves require routine descaling to eliminate mineral deposits and microbial buildup.
- Use Chamber Brite cleaner to descale chamber, reservoir, and internal tubing.
- Descaling must be performed after every .
Pack Wrappers, Indicators, and Storage
- Ideal Pack Wrapper Characteristics:
- Selective Permeability: Allows steam or gas to penetrate fully during autoclaving while acting as an absolute barrier to microbes and dust particles from the exterior.
- Resistance to Damage: High tensile strength resistant to tears, rips, or punctures during handling. Any damage must be visually obvious.
- Flexibility: Conforms tightly around irregular shapes without springing open.
- Memory: Material stays completely flat when unwrapped, preventing edges from curling back onto sterile contents.
- Types of Wrappers:
- Textiles (Cotton, Muslin): Most common reusable wrappers. Highly flexible and resistant to tears. Disadvantage: Requires laundering after every use.
- Paper / Plastic (Peel Pouches & Rolls): Single-use disposable packaging for individual instruments or small items. Advantages: Convenient, no laundering needed. Disadvantages: Expensive; paper can dry out and crack over time.

Sterilization Indicators:
- Chemical Indicator Tape: Applied externally to seal packs. Diagonal indicator lines turn dark when exposed to steam/heat, confirming the pack went through a heat cycle. Functions as a label surface recording: Pack Contents, Date Autoclaved, and Initials of the person who wrapped it.
- Chemical Indicator Strips: Placed inside the center of the pack (next to instruments or deep inside drapes/gowns). Color change confirms steam penetrated to the core of the pack.
- Biological Indicators: The gold standard for verifying true sterilization. Confirms that all three parameters (Temperature, Pressure, and Time) were successfully met.
- Vial Test: Vial containing Bacillus endospores is autoclaved, incubated for , and evaluated for bacterial growth.
- Spore Strips: Paper strips embedded with spores that change color as spores are killed. Higher cost, short shelf life.
Single vs. Double Wrapping:
- Double wrapping provides structural protection against punctures and an extra barrier against accidental contamination.
- Unwrapping Protocol: A non-sterile person unwraps the non-sterile outer layer; a sterile/scrubbed person unwraps the sterile inner layer.
- Exception: Gown and towel packs—both outer and inner layers are unwrapped by non-sterile personnel so the scrubbed surgeon can lift the sterile gown/towel directly without contacting wrapper edges.
Storage Shelf Life Rules:
- Packs must be stored in dry, dust-free, closed cupboards and dated.
| Wrapper Material | Closed Cupboard Shelf Life | Open Cupboard Shelf Life |
|---|---|---|
| Single-Layer Cotton / Crepe Paper | ||
| Double-Layer Cotton / Peel Pouch | ||
| Transparent Plastic Pouches | Up to |
- Event-Related Contamination:
- A pack is considered sterile until an event compromises it. Factors rendering a pack non-sterile:
- Moisture / Wetness (causes wicking/strike-through).
- Tears, rips, or punctures in the wrapper.
- Dropping the pack on the floor.
- Dust buildup or damaged sealing tape.
- Rule: If pack sterility is ever questioned, re-wrap and autoclave again.
- A pack is considered sterile until an event compromises it. Factors rendering a pack non-sterile:
Pack Wrapping Technique and Aseptic Opening
- General Preparation Guidelines:
- All items must be clean and dry. Use a lint roller on cloth wraps and towels.
- Soft items (towels, drapes, gowns) are folded using the accordion pleat technique (zigzag folding pattern). This allows items to unfold smoothly when lifted without dropping or contaminating edges.
- Pack dimensions must not exceed () and weight must not exceed .
- Instrument packs are assembled according to a standardized clinic recipe binder (listing exact instruments for Spay, Castration, Ophthalmic, or Orthopedic packs).

Angle Wrapping Step-by-Step Procedure:
- Orient the square wrapper as a diamond on a clean table. Place instrument tray or linen in the center.
- Bring the bottom corner flap up over the items to cover them completely. Fold the corner tip back onto itself to form a holding tab.
- Bring the left side flap across to the center, and fold its tip back to create a second tab.
- Bring the right side flap across to the center, and fold its tip back to create a third tab.
- Bring the top flap down over the pack. Tuck the flap corner under the left and right folds, leaving a short tab exposed for easy unwrapping.
- Apply a strip of chemical indicator tape across the final fold. Turn under both ends of the tape to form pull-tabs for easy removal without tearing the wrap.
Aseptic Rules for Opening Surgery Packs:
- Packs are opened onto a Mayo stand.
- The Rule: Maintain a forcefield boundary of () between non-sterile personnel and the sterile field.
- Keep hands and arms above waist level at all times.
- Never reach or extend arms across an open sterile field.
- Handle wrapper corners and tape tabs only; do not touch internal wrap surfaces.
Introduction to General Anesthesia
- General Anesthesia: Defined as a drug-induced "lack of sensation." Reversible depression of the central nervous system resulting in unconsciousness, muscle relaxation, and complete loss of pain perception.
- Premedication: Administration of drugs prior to anesthetic induction.
- Benefits: Decreases patient stress and anxiety, improves ease of handling, enhances muscle relaxation, reduces required doses of induction and maintenance agents, and ensures smooth transition and recovery.
- Analgesia: Pain management incorporated into pre-anesthetic protocols.
- Analgesic Selection Criteria: Species and breed sensitivity, anticipated surgical pain severity, drug potency, and duration of analgesic effect.
- Pre-Oxygenation Protocol:
- Administer oxygen for prior to anesthetic induction in all patients.
- Rationale: Saturates functional residual capacity and alveoli with oxygen to buffer against hypoventilation, apnea, and decreased tidal volume during induction.
- Method: Place an oxygen mask gently over the patient's nose. If the patient resists, hold the oxygen hose away from the nostrils.
Anesthetic Induction Techniques & Patient Monitoring
Anesthetic Induction Goal: Transition patient rapidly and smoothly from consciousness into Stage III surgical anesthesia to allow endotracheal () intubation.
Induction Modalities:
- 1. Inhalation (Gas Anesthesia):
- Chamber Induction: Placing a small animal in a transparent acrylic chamber filled with anesthetic gas. Disadvantages: High environmental waste gas contamination, high gas consumption, severe patient stress. Crucial Limitation: Patient vital signs (, respiratory rate, capillary refill time, mucus membranes) cannot be monitored inside the box. Contraindicated by AAHA guidelines.
- Mask Induction: Delivering gas via face mask. Disadvantages: Slow, risk of gas leakage into operating room, patient struggling/stress, high risk of aspiration if vomiting occurs, cannot evaluate oral mucus membranes or CRT under mask. Contraindicated in brachycephalic breeds or patients with respiratory distress.
- 2. Intravenous (IV) Injectable Induction (Preferred Method):
- Common Agents: Propofol, Ketamine/Diazepam, Ketamine/Midazolam, Alfaxalone.
- Advantages: Rapid, smooth transition through excitement Stages I and II; lower drug volume required than IM; allows precise titration to effect.
- Technique (Titrating to Effect): Administer IV induction agent slowly ( calculated volume over ). Wait to assess jaw tone and swallow reflex. If the swallow reflex is absent, perform endotracheal intubation. If present, administer of the remaining dose and reassess until reflexes are lost.
- Propofol Warning: Injecting propofol too rapidly causes transient apnea (respiratory arrest); injecting too slowly causes patient excitement/phothering.
- 3. Intramuscular (IM) Injectable Induction:
- Indication: Used when IV access is impossible (kittens, puppies, ferrets) or for darting fractious/wild animals (e.g., Ketamine/Dexmedetomidine mixtures in zoos).
- Disadvantages: Requires higher drug dose than IV, cannot titrate to effect, slower onset, prolonged and rough recoveries.
- 4. Oral Induction:
- Squirting liquid induction drugs (e.g., ketamine mixtures) directly into the mouth of aggressive/fractious cats prior to handling.
- 1. Inhalation (Gas Anesthesia):
Critical Monitoring Parameters During Induction:
- Patients are extremely vulnerable during induction. Continuous monitoring is essential to prevent adverse outcomes.
- Monitored Parameters:
- Heart Rate (HR) and cardiac rhythm.
- Pulse Strength: Evaluates peripheral perfusion and relative blood pressure.
- Mucus Membrane (MM) Color: Assesses tissue oxygenation and perfusion (pink = normal).
- Capillary Refill Time (CRT): Evaluates peripheral microvascular perfusion ( = normal).
- Respiratory Rate (RR) and depth of respiration.
- Reflexes & Jaw Tone: Palpebral reflex, pedal reflex, and jaw resistance evaluate depth of Stage III anesthesia.