Equipment for Aerosol-Air-Entrainment
Air Entrainment LVN - Uses sterile water and room air.
Large Bore Tubes - Two large bore tubes are used for the nebulizer interface to reduce resistance and condensation.
Drain Bag - A drain bag is used to collect condensate to prevent re-entry into the system.
Interfaces for Aerosol Therapy
Trach Collar - Used to provide humidity to patients with bypassed airways.
Face Tent - Provides humidity while minimizing irritation, particularly in trauma cases.
Aerosol Mask - Suitable for spontaneously breathing patients.
Brigg's Adapter - Designed for endotracheal or tracheostomy tubes, allows weaning from ventilation and supports an open system.
Conditions Necessitating Aerosol Therapy
Upper Airway Natural Humidification Compromised
Conditions such as post-extubation stridor indicating swelling.
Tonsillectomy patients may benefit from soothing cool mist.
Components of Aerosol Setup
Aerosol Heater - Utilized to maintain optimal humidity levels.
Temperature Probe - Monitors temperature, ideally set to 37°C.
O₂ Analyser - Measures fraction of inspired oxygen (FO₂).
Total Flow Calculation:
Total Flow = 100 LPM
O2 flow and entrained room air flow should sum to 100 LPM.
Humidity & Aerosol Therapy
Types of Aerosol: Water vapor, bland aerosols, cool, heated aerosols, and medication-infused aerosols.
Continuous Aerosol Delivery: Can be done using LVN, sterile water, or bubble humidifiers.
Therapeutic Humidity Systems: Includes wick, passover, and active versus passive systems (such as Heat and Moisture Exchangers - HMEs).
Aerosol Medications
Delivery Methods:
Metered Dose Inhalers (MDI)
Dry Powder Inhalers (DPI)
Handheld Nebulizers (HHN)
Small Volume Nebulizers (SVN)
Particle Size: Aerosols are typically within the size range of 2-5 microns for optimal delivery to the airways.
Artificial Airways
Endotracheal Tubes: Inserted through the mouth into the trachea to bypass the upper airway.
Tracheostomy Tubes: Inserted directly into the trachea; requires external humidification for optimal function.
Active Passover Heated Humidifiers
Components:
Temperature probes maintaining 37°C.
Heating wires to prevent condensation and maintain temperature.
Heater plate used to heat water, facilitating the production of water vapor.
Reservoir for storing sterile water, designed for continuous use.
Noninvasive Ventilation with SVN
Medication Delivery: When combined with noninvasive ventilation, medication delivery can occur under positive pressure conditions.
Handheld Nebulizer (HHN): Another method of delivering aerosolized medications.
Valve T-Adapter
A device that allows for aerosolized medication delivery without breaking the circuit, typically placed close to the patient for maximum efficiency.
Albuterol Nebulization
Indication: Used for asthmatic patients to relieve bronchospasms.
Dosage Calculation:
Dosage (mg/hr) = Flow rate × mg/mL
Example: With 0.5 mL per drop, the dosing via nebulization is calculated accordingly.
Humidity Systems
Wick Humidification: Utilizes a blender with small and large bore tubing, temperature probes, and O₂ analyzers to maintain humidity levels.
Active Humidity Generation: Requires heat to add water vapor effectively, helps in bypassed upper airways to prevent mucosal drying.
High Flow Nasal Cannula (HFNC)
Indications: Applied in cases of pneumonia, asthma exacerbation, bronchospasm, and post-extubation care.
Specifications:
FO₂ can be 100% and flow rates may reach up to 60 L/min.
The system includes a water bag, O2 blender, flow meter, heated circuit, active humidifier heater, and cannula for delivery.
Low Flow Devices Overview
Nasal Cannula:
Flow Rate: 1-6 LPM
FO₂ Concentration: 24-44%
Each 1 L/min increase approximates a 4% increase in FO₂ concentration.
Simple Mask:
Flow Rate: 5-10 LPM
FO₂ Concentration: 40-60%
Minimum flow of 5 LPM is required to avoid CO2 buildup.
Partial Non-Rebreather Mask:
Flow Rate: 6-10 LPM
Non-Rebreather Mask:
Flow Rate: 10-15 LPM
Oxymask:
Flow Rate: 1-15+ LPM
Nasal Cannula with Bubble Humidifier:
Flow Rate: 1-6 LPM
FO₂ Concentration: 40-70%
One-way valve system included.
High Flow Devices
Venturi Mask:
Flow Rate: 20-60 LPM
Provides accurate delivery of predetermined oxygen concentrations (e.g., 24-60%).
High-Volume Jet Nebulizer (LVN):
Flow Rate: 6-15 LPM
FO₂ Concentration: equivalent to 24-30% or as specified (dual).
Aerosol Delivery Systems: Includes T-piece, face tent, or driven aerosol mask system, capable of delivering up to 28-100% FO₂ concentration depending on the configuration.