chapter 14

Overview of Electron and Photon Behavior

  • Photon and Electron Properties

    • Higher energy increases photon doses; decreases skin dose.

    • Higher energy increases electron doses; increases skin dose.

Electron Interactions

  • Types of Electron Interactions

    • Categories:

    • Inelastic Collisions

      • Between electrons and orbital electrons in an atom (ionization and excitation).

      • Between incident electrons and nuclei of absorbing material (branched jawline).

    • Elastic Collisions

      • With atomic electrons (electron-electron scattering).

      • With nuclei of absorbing material (nuclear Coulomb scattering).

  • Collision Types:

    • Elastic Collisions:

    • Coulomb force interaction; no loss of kinetic energy but trajectory change (akin to billiard ball collisions).

    • Inelastic Collisions:

    • Energy loss from collisions results in ionization, excitation, or secondary electrons.

    • The sum of energies before and after collision differs.

Stopping Power

  • Definitions:

    • Stopping Power: Rate of energy loss per unit path length for a charged particle (energy loss per centimeter).

    • Linear stopping power: extMeV/cmext{MeV/cm}.

    • Mass stopping power: racextMeV/cmextg/cm3rac{ ext{MeV/cm}}{ ext{g/cm}^3}.

  • Energy Loss Mechanisms:

    • Caused by collisional and radiative processes.

Stopping Power Variance with Atomic Number
  • Mass stopping power (S/<br>hoS/<br>ho) higher for low atomic number (Z) materials.

  • As Z increases, the rate of energy loss decreases due to fewer available electrons for interaction.

Collisional and Radiative Losses
  • Collisional Losses:

    • Greater for low Z materials.

  • Radiative Losses:

    • Probability of bremsstrahlung increases with electron kinetic energy and Z.

    • Efficient in high-Z materials (e.g., X-ray tubes).

Energy Loss in Water
  • Electrons of energy 1 MeV lose approx. 2 MeV/cm in water.

  • Example: Range of a 20 MeV electron in water: 20 MeV2 MeV/cm=10 cm\frac{20\text{ MeV}}{2\text{ MeV/cm}} = 10 \text{ cm}.

Electron Scattering

  • Scattering of Electrons: Light electrons scatter more in lower energy and higher Z materials.

  • Scattering Foils:

    • Made of high Z materials to cause scattering and form usable radiation fields.

    • Foils must be thin to minimize X-ray contamination.

Isodose Curves
  • Variability in isodose distributions based on fields, scattering foils, and energy.

  • Coins and collimators can affect the shape of these curves.

Depth Dose Characteristics

  • Dmax:

    • Depth at which the dose reaches maximum value; varies by energy.

    • Increase with field size.

Output Calibration and Measurement

  • Calibrated Output for Electrons:

  • Definition: Absorbed dose per monitor unit at Dmax in a standard applicator (10x10 cm).

  • Corrections needed for different apparatus setups, SSD changes, and application field sizes.

  • Calibrating devices: ionization chambers and thermoluminescent dosimeters are used.

Equivalent Materials for Electron Dosimetry

  • Materials should mimic water's stopping power, scattering power, density, and effective atomic number.

  • Suitable materials: polystyrene and acrylic.

Important Formulas
  • Ranges for electron dose calculation:

    • P90=E3.2P_{90} = \frac{E}{3.2} for 90% isodose line.

    • D80=E2.8D_{80} = \frac{E}{2.8} for 80% isodose line.

Skin Sparing Effect

  • Allows skin surface doses to increase with energy; skin dose is notably high (80-100% of maximum).

X-ray Contamination

  • X-ray contamination from bremsstrahlung; increases with energy.

  • Ranges of contamination by energy brackets:

    • 6-12 MeV: 0.5-1% contamination.

    • 12-15 MeV: 1-2%.

    • 15-22 MeV: 2-5%.

SSD Parameters in Linear Accelerators

  • Source Positions: Electrons from virtual sources; thus, SSD calculations differ from photons.

  • Effective SSD: Useful for correcting output using the inverse square law, taking into account the gap and energy levels.

Summary Technique for Distance Correction
  • Two methods to adjust for distance:

    • Use virtual SSD in conjunction with the inverse square law.

    • Use air gap factor.

Treatment Depth and Efficiency
  • Increase in treatment efficiency with appropriate calibration and correction methods for electron beams.

Statistical and Practical Calculations
  • Use specific tables for determining Dmax and PDD for precise calculations during treatment planning.

  • Practical applications based on energy and distances crucial for effective patient treatment.

    Photon and Electron Properties

    • Higher energy increases photon doses; decreases skin dose.

    • Higher energy increases electron doses; increases skin dose.

  • Types of Electron Interactions

    • Inelastic Collisions: Ionization and excitation of orbital electrons.

    • Elastic Collisions: Changes in trajectory without loss of kinetic energy.

  • Stopping Power

    • Stopping Power: Rate of energy loss per unit path length.

    • Linear stopping power = extMeV/cmextMeV/cm; Mass stopping power = racextMeV/cmextg/cm3racextMeV/cmextg/cm3.

  • Mass Stopping Power: Higher for low atomic number (Z) materials; decreases with higher Z.

    • Collisional losses: Greater for low Z materials.

    • Radiative losses: Increases with electron kinetic energy.

  • Energy Loss in Water

    • Electrons of energy 1 MeV lose approx. 2 MeV/cm in water.

    • Range of 20 MeV electron in water is 10 cm.

  • Dmax: Depth at which the dose reaches maximum value; increases with field size.

  • Calibrated Output: Absorbed dose per monitor unit at Dmax in a 10x10 cm applicator.

  • Skin Sparing Effect: Skin surface doses increase with energy; skin dose can be 80-100% of maximum.

  • X-ray Contamination: Increases with energy in specified ranges.

  • Electron Beam Characteristics: Electrons exhibit a finite range in tissue, which is affected by energy and field size; higher energy electrons penetrate deeper but may also lead to increased scatter.