Clinical Skills Protocol: Female Urinary Catheterization & Ostomy Care Study Guide

Female Urinary Catheterization: Equipment and Pre-Insertion Setup

  • Sterile Gloving Procedure:

    • Glove the dominant hand first.
    • Reach under the cuff of the second glove to don it on the non-dominant hand while preserving sterile technique.
  • Patient Draping and Sterile Field Extension:

    • Place two protective draping pads to significantly extend the sterile working field.
    • Under Pad Placement:
    • The under pad is placed beneath the patient's buttocks.
    • Hold the under pad on the dull (absorbent) side to prevent contamination of the sterile area.
    • Enlist an assistant to assist the patient in lifting their buttocks.
    • Allow the pad to unroll and fall naturally beneath the patient's bottom with the shiny (moisture-proof) side facing down against the bed linen.
    • Avoid standing directly within the sterile field boundary while placing the pad to prevent contamination.
    • Fenestrated Drape Placement:
    • The fenestrated drape features a center opening (fenestration) that exposes only the perineal and genital region.
    • Allow the drape to unfold naturally without shaking or snapping it.
    • Position the shiny side facing down toward the patient and carefully drape it over the genital region.
  • Foley Catheter Kit Identification and Specifications:

    • Kit Contents:
    • Foley catheter connected to a drainage bag.
    • Catheter securement device (StatLock device).
    • Povidone-iodine solution and swab sticks.
    • Syringe pre-filled with sterile water.
    • Water-soluble lubricating jelly packet.
    • Optional specimen collection cup with patient identification labels.
    • Catheter Specifications:
    • Size: Standard female catheter size 14 French14\,\text{French}.
    • Balloon Inflation Volume: Pre-filled syringe containing 10 mL10\,\text{mL} of sterile water.
  • Balloon Pre-Testing Caution:

    • Do not pre-attach the sterile water syringe or pre-inflate the catheter balloon prior to insertion.
    • Evidence indicates that pre-inflating and deflating the balloon alters its pre-molded shape and creates subtle micro-creases in the silicone/latex material.
    • Inserting a pre-tested, misshapen balloon damages urethral mucosal tissue upon insertion, creating an entry portal for bacteria and increasing the risk of a Catheter-Associated Urinary Tract Infection (CAUTI).
  • Catheter Preparation and Lubrication:

    • Open the povidone-iodine packet and pour the solution directly over the three swab sticks in the tray.
    • Attach the pre-filled 10 mL10\,\text{mL} sterile water syringe directly to the balloon inflation port, leaving it connected and ready for post-insertion inflation.
    • Dispense the water-soluble lubricating jelly into the designated tray compartment.
    • Carefully remove the catheter from its clear plastic sleeve.
    • Keep the catheter loosely coiled in the dominant sterile hand; pulling it rapidly out of the sheath causes it to spring back, strike unsterile surfaces, and compromise sterility.
    • Lubrication Depth: For female patients, coat at least the distal 2 inches2\,\text{inches} of the catheter tip thoroughly in lubricant to facilitate comfortable, non-traumatic entry.

Female Urinary Catheterization: Cleansing and Insertion Protocol

  • Perineal Cleansing Technique:

    • Place the non-dominant hand onto the patient's labia to spread the labia minora widely, exposing the urethral meatus.
    • Sterility Rule: Once the non-dominant hand contacts the patient's skin, it is contaminated and non-sterile. It must remain firmly in place holding the labia open throughout the entire insertion process.
    • Cleansing Sequence using Povidone-Iodine Swabs:
    • Swab 11: Wipe the labium majora/minora furthest away from the nurse in a single downward motion from top to bottom (anterior to posterior), then discard the swab.
    • Swab 22: Wipe the labium majora/minora closest to the nurse in a single downward motion from top to bottom, then discard the swab.
    • Swab 33: Wipe directly down the center over the urethral meatus in a single downward motion from top to bottom, concentrating directly on the meatus, then discard the swab.
    • Maintain cleansing direction from clean to dirty (top-to-bottom / anterior-to-posterior) and inside-to-outside to prevent cross-contamination.
  • Patient Coaching and Insertion Steps:

    • Instruct the patient to concentrate on deep breathing, taking slow breaths in and out, and to bear down gently (as if voiding).
    • Bearing down and deep breathing relaxes the external urethral sphincter, facilitating smooth passage.
    • Time insertion to coincide with the patient's slow exhale.
    • Gently advance the catheter into the urethral meatus approximately 2 to 3 inches2\text{ to }3\,\text{inches} until a clear visual return of urine is noted in the drainage tubing.
    • Once urine return is observed, advance the catheter an additional 2 inches2\,\text{inches} to guarantee the balloon is fully positioned inside the bladder vault rather than wedged in the urethral canal.
  • Balloon Inflation and Verification:

    • Inject the entire 10 mL10\,\text{mL} of sterile water from the attached syringe into the balloon port.
    • Disconnect the empty syringe while holding down the plunger to prevent backflow.
    • If the patient complains of severe pain during inflation, stop immediately and aspirate the fluid; pain indicates the balloon is being inflated inside the urethra. Advance the catheter further into the bladder before re-inflating.
    • After successful inflation, gently pull back on the catheter until slight resistance is felt, confirming that the inflated balloon is resting securely against the bladder neck.

Catheter Securing, Drainage Bag Placement, and Post-Procedure Care

  • StatLock Securement Device Application:

    • Always snap the catheter into the StatLock retainer before adhering the device pad to the patient's skin.
    • Directional Orientation: Locate the directional arrow printed on the StatLock device; ensure the arrow points directly toward the catheter insertion site (patient's perineum).
    • Positioning the Catheter in Retainer:
    • Position the bifurcation hub (where the balloon port and main drainage lumen split) over the center post of the StatLock.
    • Rest the small white retaining clip in between the bifurcated tubes.
    • Secure the retainer shut by pressing down firmly on the side closure tabs (press on the designated outer printed lines, not in the center) until locked in place.
    • Leg Positioning and Slack Calculation:
    • Position the female patient's leg in full extension.
    • Select an anchor location on the inner thigh.
    • Provide adequate slack in the catheter line between the urethral meatus and the StatLock to prevent tension or traction on the urethra during leg movement.
    • Standard placement technique: Extend the catheter to the desired inner thigh spot, then move the device back proximally about 1 inch1\,\text{inch} toward the perineum to create a natural stress-relief loop/slack before adhering.
    • Skin Prep and Labeling:
    • Clean and thoroughly dry the inner thigh skin site.
    • Apply skin protectant prep pad if available.
    • Peels the adhesive backings off the StatLock pad and press firmly onto the inner thigh skin.
    • Document the date and time of catheter insertion directly on the securement device pad or drainage bag label.
  • Drainage Bag Placement Rules:

    • Position the drainage bag below the level of the bladder at all times to promote unobstructed gravity drainage and prevent urine backflow into the bladder.
    • Secure the bag frame hooks to a non-movable part of the bed frame (such as the main bed frame base).
    • Safety Warning: Never attach the drainage bag or tubing to bed side rails; raising or lowering side rails can pull, dislodge, or traumatically yank the catheter.
    • Ensure the drainage tubing forms a straight, continuous line without loops hanging below the bag level to maintain continuous gravity flow.

Ostomy Management: Equipment, Assessment, and Pre-Procedure Preparation

  • Ostomy System Types:

    • One-Piece System: The skin barrier (wafer/flange) and the collection pouch are permanently integrated into a single unit.
    • Two-Piece System: The skin barrier wafer and collection pouch are separate components that snap securely together via a plastic coupling ring flange.
  • Essential Ostomy Supplies:

    • Replacement ostomy pouching system (one-piece or two-piece).
    • Flexible barrier ring (optional moldable ring used around the stoma base to fill uneven skin contours and prevent leakage).
    • Closure tail clip or integrated Velcro closure system.
    • Stoma measuring card/guide (calibrated in millimeters).
    • Curved ostomy scissors: Specialized scissors featuring curved blades and smooth, flat tips designed to cut smooth circular patterns into wafers without leaving sharp, jagged edges that could lacerate the stoma.
    • Skin barrier prep wipes/sprays.
    • Non-sterile gloves, clean washcloths, warm water, basin, and a protective waterproof drape/towel.
    • Fine tip pen/marker.
  • System Change Frequency and Emptying Guidelines:

    • System Replacement Frequency: Ostomy pouching systems are routinely changed every 3 to 5 days3\text{ to }5\,\text{days}. More frequent daily changes should be avoided unless active leakage occurs, as frequent removal causes skin stripping and severe peri-stomal skin breakdown.
    • Emptying Threshold: Empty the collection pouch when it becomes 13 to 12\frac{1}{3}\text{ to }\frac{1}{2} full of effluent or gas. Allowing a bag to overfill adds weight, breaking the adhesive seal and risking pouch detachment.
  • Odor Control and Timing Considerations:

    • Odor Mitigation: Changing an ostomy system produces strong, pungent fecal odors. Nurses sensitive to odors can apply mentholated ointment (such as Vaporub) directly underneath their nose/mask prior to beginning the change.
    • Specialized ostomy pouches contain built-in charcoal filters that allow gas to vent automatically while neutralizing odors.
    • Optimal Timing: Change the pouching system when the bowel/gut is least active—typically early in the morning before breakfast, or several hours after meal consumption.

Ostomy Bag Removal, Peri-Stomal Cleansing, and Skin Assessment

  • Removal Protocol:

    • Place a towel across the patient's abdominal area to protect their skin, clothing, and gown from accidental stool leakage.
    • Don clean gloves.
    • Gently push down on the peri-stomal skin while pulling the adhesive wafer barrier away from the abdomen in a top-to-bottom direction.
    • Use adhesive remover wipes if the barrier is adhered tightly to prevent traumatic skin tears.
    • Discard the used pouching system in a designated biohazard trash receptacle.
  • Peri-Stomal Skin Cleansing and Inspection:

    • Cleanse the skin surrounding the stoma using a washcloth with plain warm water.
    • Contraindicated Products: Do not use soaps containing lotions, creams, powders, oil additives, or alcohol around the stoma. These products leave a residue that prevents the new skin barrier wafer from adhering to the skin and can irritate tissues.
    • Inspect Peri-Stomal Skin:
    • Inspect for extreme erythema (redness), excoriation, or skin breakdown.
    • Erythema immediately around the stoma indicates stool leakage beneath the barrier wafer.
    • Address leakage breakdown by applying a moldable barrier ring and reshaping/recutting the barrier wafer opening for an exact fit.
  • Stoma Assessment and Hair Trimming:

    • Stoma Assessment:
    • The stoma is inverted intestinal mucosa flipped inside out; it possesses no pain receptors, so gentle touching/cleansing is completely painless for the patient.
    • Healthy stomas appear beefy red or deep pink and moist.
    • Gently wash the surface of the stoma and pat the entire area completely dry with a towel.
    • Drying Rule: The peri-stomal skin must be thoroughly dry; lingering moisture prevents barrier wafer adhesion.
    • Abdominal Hair Trimming: If significant abdominal hair is present around the stoma, carefully trim the hair using safety shears. Shaving or leaving hair intact causes painful hair-pulling (waxing effect) during subsequent wafer removals and causes folliculitis.

Stoma Measurement, Wafer Fitting, and Appliance Application

  • Measuring the Stoma:

    • Select the stoma measuring card and place the cutouts directly flush against the base of the stoma.
    • Clearance Dimension: Select an opening size that provides a exact 18 inch\frac{1}{8}\,\text{inch} (≈3.175 mm\approx 3.175\,\text{mm}) clearance around the entire circumference of the stoma base.
    • Sizing Rationale:
    • Cutting the opening too large exposes peri-stomal skin to acidic bowel effluent, leading to severe chemical skin breakdown and ulceration.
    • Cutting the opening too small constricts the stoma, pinching blood supply and causing tissue ischemia, ulceration, or stoma necrosis.
    • Example Metric Sizing: A standard round stoma base measuring 45 mm45\,\text{mm} requires a matching 45 mm45\,\text{mm} cut guideline on the wafer.
  • Wafer Tracing and Cutting Mechanics:

    • Locate the pre-printed metric sizing concentric rings on the paper backing of the skin barrier wafer.
    • If pre-printed rings are absent, place the calibrated measuring card cutout over the wafer backing and trace the exact circle (e.g., 45 mm45\,\text{mm}) using a pen.
    • Use curved ostomy scissors to cut along the traced circle.
    • Smooth the inner cut edges with a finger to remove sharp paper/plastic burrs that could chafe the stoma.
  • Appliance Preparation and Attachment:

    • Pre-Closure Steps: Always attach and snap the tail clip or fold/press the integrated Velcro tail closure tightly closed before adhering the wafer to the patient's abdomen.
    • Barrier Ring Application (If Indicated):
    • Peel the backing off the moldable barrier ring and press it firmly around the stoma orifice, sealing any uneven skin folds.
    • Wafer Placement:
    • Peel the protective paper backing off the prepared adhesive wafer.
    • Center the opening directly over the stoma and press it firmly against the dry skin.
    • Smooth the barrier wafer outward from the center base toward the outer edges, applying firm pressure to ensure complete, wrinkle-free adhesion to the abdominal skin.
    • Coupling 2-Piece Systems: Align the pouch flange over the wafer flange and press firmly around the entire ring circumference until audible and tactile snap-clicks confirm a complete seal ("hear every single click").
  • Gas Release ("Burping") Procedures:

    • Educate the patient that gastrointestinal gas builds up inside the pouch, causing ballooning/inflation.
    • Instruct patients on how to "burp" the bag to release trapped gas without spilling liquid stool.
    • Unclip the top flange coupling slightly (or release the bottom tail clip) while tilting the outlet upward to release air pressure, then reseal immediately.
    • Pressure Warning: Failing to burp an inflated bag creates high internal pressure that can force the wafer seal off the skin, rupture the bag, or cause explosive splashing upon opening.

Clinical Practice Considerations, Q&A, and Dialogue Highlights

  • Questions & Discussion: Workflow and Hygiene Order

    • Student Question: Should peri-stomal or perineal pre-cleansing occur before opening sterile supplies?
    • Clinical Rule: Pre-cleansing dirty skin (hygienic cleaning with soap/water or wipes) is always performed first with clean non-sterile gloves. Remove those gloves, perform hand hygiene, and then set up the sterile field and sterile supplies for sterile catheterization or clean barrier application.
    • Student Question: Where should sterile equipment trays be placed during preparation?
    • Clinical Rule: Transfer the sterile packaging/tray directly onto the overbed table or clean bedside surface adjacent to the bed before opening it, keeping supplies easily accessible without reaching over unsterile boundaries.
  • Questions & Discussion: Effluent Consistency and Container Selection

    • Student Question: How does effluent consistency affect emptying and bag changes?
    • Clinical Rationale: Liquid effluent (typical of ileostomies) drains continuously and contains active digestive enzymes that severely irritate skin. Liquid systems require frequent emptying into a graduated collection container/bedpan and careful skin barrier protection.
    • Formed or semi-formed stool (typical of sigmoid/descending colostomies) presents less chemical skin threat but requires routine emptying when 13\frac{1}{3} full.
    • Bedpans used for emptying liquid or solid stool are reusable for the individual patient; line bedpans to facilitate easy disposal, or empty stool into the patient's toilet and rinse thoroughly.
  • Documentation Requirements:

    • Chart the procedure details in the electronic health record (EHR) flow sheet system rather than relying solely on shift report handoffs.
    • Record the date, time, catheter French size (14 French14\,\text{French}), balloon water volume injected (10 mL10\,\text{mL}), stoma size (45 mm45\,\text{mm}), effluent color/amount/consistency, peri-stomal skin condition, and patient tolerance.
    • Place dating tape directly on the drainage bag or inner thigh securement device to inform incoming nursing staff when maintenance or replacement is due.