Lab 13/14 EMG and Biofeedback
Electrode Preparation and Equipment Setup
Electrode Requirements
Necessary equipment includes electrodes, a computer, and a data collection device.
Understanding Electrical Activity in the Heart
Experimental Setup
When teaching anatomy, a common practice involved having subjects remain in semi-darkness for around one minute before shining a flashlight into their eyes.
This demonstration emphasizes the eyes' response: pupils dilate in darkness and constrict with light.
Electrical Activity of the Heart
The heart's electrical waves are transmitted through body fluids, which contain salts.
Common terminology includes:
Electrolytes: salts in body fluids (similar to those found in drinks like Gatorade).
ECG Electrode Types and Connections
Biopack ECG Electrode Specifications
Electrodes consist of three connections:
White: negative lead
Red: positive lead
Black (sometimes brown): ground lead
Correct placement:
White electrode is placed on the right wrist.
Project Overview
Conducting a test with heavyweight boxers to compare the effectiveness of a custom mouthpiece versus a general mouthpiece made by dentists.
Example participant:
A heavyweight boxer, ranking tenth globally, weighing 220 pounds and measuring 6'8”.
Body fat percentage measured at 2.2%.
EKG Terminology and Data Collection
Electrode and Lead Definitions
"Leads": the wires used to collect data from electrodes.
The output from these wires is also referred to as leads.
In a 12-lead EKG, 10 wires must be connected.
12 lead does not imply 12 wires but specific measurements achieved from 10 connections.
Visualization of Heart Activity
The number of leads affects the views of the heart captured.
Measuring Sweat Rate with ED
Introduction to EVA Measurement
Set up involves attaching two electrodes to measure the electrical difference, referred to as ED.
The primary measurement: sweat rate, which consists of water and electrolytes.
Increased sweating changes the measured electricity due to variations in electrolyte composition.
Set Up for EMG Measurements
Electrode Positioning for EMG
A setup requires three electrodes: typically red, green, and white.
The red electrode should be placed at a higher position compared to the others.
Proper positioning increases muscle activity detection:
Incorrect positioning yields low activity readings.
Setting Up the Experiment
Using different subjects for the EMG setup compared to previous experiments for accuracy.
Electrode placements mirrored on both arms to ensure a balanced comparison of muscle activity.
Warning on reversing electrodes: correct placement is crucial for accurate readings.
Data Collection Procedure
The procedure emulates a timer system, similar to a drive-through timer at a fast food restaurant.
Clear instructions are provided to subjects before reading begins:
Participants instructed to contract and relax arm muscles while data is collected.
Evaluating Data Validity
Expected data pattern includes progressive growth in readings from $25$, $50$, $75$, to $100$.
If data does not meet expectations, a redo should be implemented to ensure reliable measurements.
Additional Considerations and Equipment
Nondominant Arm Characteristics
Observations regarding the nondominant arm typically demonstrate less coordination, affecting EMG data quality.
Equipment Configuration
Biopack or similar machines should be equipped with a power cord and necessary connections to operate effectively.
Need for accurate login credentials: username and password to access equipment and software.
Setup should be immediate to maximize efficiency of simultaneous measurements on two subjects.
Final Steps
Once equipment is powered and logged in properly, the data collection interface will activate for use.