Dental Radiography Exam Notes
Digital Radiography
Primary advantage: Reduces radiation to the patient.
Contrast in a digital image is primarily controlled by kVp.
Inverse Square Law
When changing from an 8-inch PID to a 16-inch PID, the inverse square law is used to determine beam intensity.
Effects of Radiation
Radiation has the potential to cause harmful biologic changes.
PID Shapes and Radiation Exposure
Rectangular-shaped PIDs reduce patient radiation exposure by up to 70% compared to round PIDs.
The rectangular PID shape most effectively reduces patient exposure to radiation.
Cells and Radiation
Cells exposed to radiation that may be associated with leukemia: Somatic cells.
Radiation Monitoring
Personnel radiation monitoring devices are worn to record the occupational exposure received by the operator.
Personnel monitoring for radiation exposure is done by wearing a dosimeter.
X-ray Tubehead
Leaded-glass housing prevents x-rays from escaping the tubehead.
Operator Distance
Minimum distance the operator should stand from the tube head when exposing radiographs: 6 feet.
Education and Certification
The Consumer-Patient Radiation Health and Safety Act was established to address the education and certification of operators of radiographic equipment.
Ionizing Radiation
To produce ionizing radiation, an atom must lose a proton.
Shielding
Dental healthcare personnel can best shield themselves from radiation during patient exposure by standing behind a drywall barrier.
Measuring Radiation Injury
Radiation injury can be measured by dose rate.
Factors Determining Radiation Injury
The amount of tissue irradiated is used in determining the degree of radiation injury.
Wavelength and Energy
The shorter the wavelength of electromagnetic radiation, the greater the energy.
Landmarks for Image Mounting (Maxillary Posterior)
Floor of the maxillary sinus is useful when mounting images in the maxillary posterior area.
Artificial Radiation Exposure
The most common artificial radiation exposure comes from medical radiation.
Radiosensitivity
The most highly radiosensitive tissue is reproductive.
Long-Term Effects of Radiation
Long-term effects of exposure to radiation may be associated with birth abnormalities.
Radiation Protection Methods
To minimize exposure to the radiographer, employ barrier, monitoring device, and appropriate operator position.
Dental X-ray Prescription
Dental x-rays should be prescribed when the benefits outweigh the risk of harm.
Leakage Radiation
Leakage radiation is defined as any radiation that is emitted from the tubehead.
Rectangular Collimator
The purpose of a rectangular collimator is to reduce radiation to the patient.
Landmarks for Image Mounting (Maxillary Central)
Anterior nasal spine is useful when mounting images in the maxillary central area.
ALARA Concept
Using the ALARA concept as a guideline for radiographs includes all of the following EXCEPT using a circular PID.
Electron Speed
affects the speed of the electrons emitted from the tubehead.
Aluminum Filtration
For x-ray machines operating at or below 70 , the total aluminum equivalent filtration must be a minimum of 1.5 mm.
Operator Protection
Structural shielding is used to minimize x-radiation exposure to the operator.