POLYGRAPHY (LIE DETECTION) - LABORATORY MODULE 1


Lesson Proper 1: Major Parts of the Polygraph Machine

The 4 Major Components:

  1. Pneumograph – made up of two hollow corrugated tubes that are roughly seven to ten inches long that attach to the thoracic and abdominal region of the subject to record breathing patterns. The tubes expand and contract when the patient inhales and exhales, transferring the change from bellows to the pen and onto the chart.

  2. Galvanograph – attaches to the palmar and dorsal surfaces or the index and ring fingers of the left hand. A minuscule amount of electrical current is passed through the hand or fingers wearing the attached electrodes to attach the electrodes, which are utilized to record the GSR or electro dermal responses.

  3. Cardiosphygmograph – made up of a blood pressure cuff, pump, and "sphygmomanometer." The cuff is attached to the upper right arm, directly above the brachial artery fold in the elbow. When the cuff expands, the examinee's blood pressure causes the muscle to contract and expand, which raises the cuff's internal pressure and bellows.

  4. Kymograph – device that records charts for the instrument and used by the examiner to determine pulse rate and question spacing. Its speed constant is essential because the vertical lines on the chart, which are spaced half an inch or an inch apart, correspond to intervals of five or ten seconds.

  5. Polygraph Software – for the software to understand the examinee's physiological data, the instrumentation that is attached to the subject feeds into a control box that plugs into the computer. With the development of the software, exam data can now be recorded and stored more easily than with outdated filing systems and chart paper.

 

Other Components:

  1. Pneumograph tube – fastened on the subject’s chest and abdomen through the beaded chain.

  2. Blood pressure cuff – the same type used by physicians is fastened on the subject's upper right arm or bicep.

  3. Finger electrodes – fastened to the left index and ring fingers of the subject.

  4. Pen lifter – raises or lowers pens to 3 positions.

  5. Program pacer – a programmable cueing device for question and answer spacing.

  6. Paper tear bar – provides the cutting edge for convenient removal of charts.

  7. Foam Pen Hold-Down – keeps pens in place when instrument is being transported.

  8. Attaché compartment – storage for all forms and supplies.

  9. Mechanical Pneumo Module – recording part of the mechanical Pneumo Channel.

  10. Galvanic Skin Response Module – recording part of the GSR channel.

  11. Multi-function Module – selectable recording module that can be used as: (a) electronic pneumo channel; (b) electronic cardio channel; (c) cardio activity monitor; (d) cardio tech or other accessories.

  12. Mechanical cardio module – recording part of the mechanical cardio module.

  13. Paper storage compartment – holds two spare rolls of chart paper or other supplies.

  14. Chart drive roller lever – lifts chart drive roller for paper change and chart removal.

  15. Power analyzer – automatically indicates whether the wall outlet is properly wired and grounded for proper instrument operation and subject safety.

  16. Stimulus marker – marks significant events on the chart.

  17. Sphygmomanometer Dial – reads the operating pressure of cardio channels.

  18. Pneumo 1 – pneumatic connection for upper (thoracic) pneumograph. Not connected in the instrument with only one Pneumo Channel.

  19. Pneumo 2 – pneumatic connection for lower (abdominal) pneumograph.

  20. Cuff – pneumatic connection for Cardio Channel subject cuff tubing.

  21. Pump – pneumatic connection for hand pump used to inflate the subject cuff.

  22. Mechanical cardio switch – disengages Mechanical cardio Module from the pneumatic system for low-pressure Electronic Operation.

  23. Resonance Control – allows you to clear or make a better pattern when you have too much pulse pressure of the subject.

  24. Hand Electrode – fastened to the hand by a stretched band. Function is to make electrical contact with the subject.

  25. Panel Control – allows the   operator   to   control   or   adjust   the   operation   of   the galvanograph.

 




Lesson Proper 2: Attachments of the Major Components

Step-by-step attachment of the major components

  1. The first sensor to be attached to the subject are the two tubes of the pneumograph which are placed on their abdomen and upper/middle chest area.

  2. It is customary to attach the lower or abdominal sensor to the subject before attaching respiratory sensors. The convoluted tube should be stretched by one to two inches when the examiner first attaches this sensor, until it is secure enough to prevent it from falling or moving out of position while still allowing the examinee's breathing pattern to be recorded.

  3. The examiner then uses the same general techniques as previously mentioned to properly position the second or top convoluted tube.

  4. The examiner should stand in front of the examinee once both respiratory sensors have been attached in order to verify that the convoluted rubber tubing is properly attached.

  5. The EDA fingerplate electrode assembly is the second physiological sensor that is attached to the subject.

  6. The "nondominant" hand's two fingers are the optimal location for the fingerplates. This is because the "dominant" hand typically has more layers of calluses, thicker outer skin, and other characteristics that could obstruct or hinder the flow of the EDA signal between the finger and the fingerplates.

  7. Typically, the fingerplates are positioned on the tips of the index and ring fingers or on their end joints. The examiner should make sure the fingerplates are secured enough to prevent them from coming loose, but they shouldn't be fastened so tightly that it causes the subject to struggle.

  8. The cardiovascular monitoring sensor, also known as the "cardio cuff" assembly, is the third sensor to be attached to the subject.

  9. To reduce potential distortions in the EDA tracing, the cardiac cuff should ideally be placed over the brachial artery in the upper arm of the subject that is opposite the hand that the EDA sensor is on.

  10. It is advised that the "center of the rubber bladder" be positioned exactly over the brachial artery in order for the bladder to receive and transmit the ideal cardiovascular signal to the sensor box or analog instrument.

Lesson Proper 3: The Instrument and How it Works

How does the instrument work?
The basis of the polygraph is the idea that physiological changes in the body are an accurate indication of psychological states. In reality, when people lie, they frequently feel fear, shame, anxiety, guilt, and worry – especially when it comes to high-stakes criminal investigations or job applications.

Through the use of a horizontal kymograph, the polygraph simultaneously captures a variety of these physiological changes. The resulting chart shows the following: systolic and diastolic heart contractions, pulse fluctuations measured by a sphygmomanometer, and psycho-galvanic skin response measured by attaching electrodes to the subject's fingers, as well as tracing of external respiration in the thoracic and abdominal cavities. A synchronous electrical motor powers a hollow-tube ink style that moves across horizontal and vertical ruled surfaces to record every change.

 The physiological changes within the examinee’s body are monitored by the following polygraph attachments:

  1. Respiratory rate – the air inside the tubes is displaced by the expansion of the muscles in the chest and abdomen. The energy of the displaced air is converted into electrical signals by transducers in a digital or computerized polygraph.

  2. Blood pressure/heart rate – the rubber hose is attached to the bladder, and it travels past a pressure gauge to a highly sensitive bellow and the lever mechanism that powers the pen. Again, the transducers transform these signals into electrical signals in digital polygraphs.

  3. Galvanic skin resistance – the examinee has two fingers attached with finger electrodes to assess the electrical conductivity of their skin. Skin conducts electricity far more rapidly when it is moist than when it is dry.



Lesson Proper 4: The Examination Room

An essential element of the polygraph exam is the examination room. Failure to maintain the room properly might affect the results and provide false positives or false negatives.


Characteristics of the Examination Room

  1. Semi-soundproof room.

  2. Free from extraneous noises.

  3. No other spectators allowed in the room.

  4. No conversation to people outside the examination room.

  5. No ringing telephones, pagers, or cellular phones.

  6. The arresting officer should be kept out.

  7. Should not contain any ornaments, picture, or other objects.

  8. The subject should not face a glass window or another room during the test.

  9. The lighting fixture of the room should be arranged in such a way to provide good but not excessive glaring illumination.

  10. Should be adequately ventilated, with an even and comfortable temperature.

 Similar to psychology labs, there must be an "observation room" next to the examination room.  The wall between the rooms needs to have a "one-way mirror" installed on it so that the co-examiners can view the subject from the observation room and look for observable behavioral symptoms related to the question of truthfulness or deception.

If it is possible, the examination room should have a discreet microphone installed so that those in the observation area may both hear and see the questions being asked in the examination room.

At least one woman should be assigned to the observation room since the test needs to be conducted in a private setting. This will protect the female subjects as well as the examiners from potential misbehavior accusations of physical or sexual abuse.