Protects the experimenter from potentially toxic or pathogenic samples.
Personal Protective Equipment (PPE):
Protects you from contamination by bacteria and prevents bacterial contamination from entering the workspace.
Disinfectant Used:
70% ethanol (write out the full word; do not abbreviate or capitalize).
Microorganisms in the Air:
True statement that microorganisms (e.g., bacteria, single-celled fungi) exist in the air. Not all microorganisms are harmful (example: sourdough fermentation).
Proper Lab Technique
Lid Orientation:
Inside surface of the tube lid should be placed down to prevent contamination from airborne microorganisms.
Introduction to DNA Purification Process:
Purifying genomic DNA from Bacillus subtilis requires high levels of sterile technique to prevent contamination.
Steps in DNA Purification
Lysis of the Cells:
Add 50 microliters of lysozyme (a natural enzyme that digests bacterial cell walls) to a microfuge tube with bacteria.
Incubate at 37°C for 30 minutes (optimal temperature for lysozyme).
Removing Unwanted Biological Macromolecules:
Add 25 microliters of SDS and 12.5 microliters of proteinase K.
Functions of SDS:
A. Dissolves the bacterial plasma membrane
B. Denatures proteins
Correct answer: Both A and B (D).
Functions of Proteinase K:
C. Hydrolyzes proteins, breaking them into smaller pieces.
Correct answer: Hydrolyzes proteins (C).
Separation of Macromolecule of Interest:
Denaturing Agents:
SDS facilitates access for proteinase K to denature proteins and destroy bacterial DNA.
**Next Steps: **
Vortex to mix, then incubate for 30 minutes at 55°C.
Add 200 microliters of 5 molar sodium chloride and 800 microliters of chloroform.
Purpose of Chloroform:
A. Further denatures proteins.
B. Separates proteins from the aqueous phase containing DNA.
Correct answer: Both A and B (D).
Mixing Solutions:
Invert tube several times but do not vortex as it can shear DNA.
Incubate for 10 minutes at room temperature.
Centrifuge the mixture at 12,000 g for 10 minutes to separate phases: chloroform (bottom) and aqueous (top) phase with DNA.
Handling Aqueous Phase
Carefully transfer the top aqueous phase into a new microfuge tube using a p 1000 micropipettor set to 600 microliters.
Prioritize getting clean DNA over volume.
Precipitation of DNA
Incubate the new tube on ice for 5 minutes.
Prepare 70% ethanol on ice (to precipitate DNA).
Add 750 microliters of ice-cold isopropanol to precipitate DNA.
Allow another 5 minutes on ice, then spool DNA using a sterile glass pipette.
Rinse off excess salts with ice-cold 70% ethanol,
Wait for the ethanol to evaporate before proceeding.
Cleaning Up
Dispose of chloroform waste in the appropriate container and place empty tubes into designated waste containers.
Prepare new 1.7 mL microfuge tubes with 200 microliters of sterile saline citrate (acts as stabilizing solution and buffer).
Gently swirl and mix until DNA is dissolved.
Measuring DNA Concentration
Utilize spectrophotometry for measuring DNA concentration.
Linear Range Requirement: Absorbance should be less than 1.
Create two dilutions for measurement (1:10 and 1:50) using saline citrate.
For each dilution, ensure thorough mixing of DNA after vortexing.
UV Spectrophotometry Using Nanodrop:
Absorption Maximum for DNA: 260 nanometers.
The Nanodrop uses microliter volumes, important for samples with small quantities of DNA.
Cleaning and Blanking the Nanodrop:
Pipette 2 microliters of distilled water and then 2 microliters of saline citrate for blanking measurements.
Measuring Samples:
Record absorbance and DNA concentrations for both dilutions in the lab notebook, including A260/A280 and A260/A230 ratios.
Calculating DNA Concentration
Use readings from each dilution to calculate stock DNA concentration and required volumes of DNA for transformations in Lab 8.
Follow instructions provided by the TA and in the Lab 7 calculations file.
Conclusion
This lab integrates careful sterile technique, biochemical understanding, and practical applications in DNA purification and measurement, laying the groundwork for subsequent labs.