Speech Audiometry
Why Speech Audiometry?
Why do we perform hearing tests using speech stimuli?
Most of the time when clients come in they say they had a hard time hearing or understanding speech.
Why do we need to test using both pure tones and speech?
What do we typically hear?
Complex signals
What is a pure tone?
When a body oscillates showing only one frequency of vibration, it is said to be a pure tone
Examples:
1000 Hz on the audiometer = pure tones
The tuning fork = one frequency of vibration = pure tone
What is a complex sound?
This contains energy at a number of different frequencies, amplitudes, and phases.
Is speech complex?
Speech is a complex signal!
What is the definition of a threshold?
For pure tones = the level at which a pure tone is barely perceptible.
The level of loudness needed for the subject to be aware of the sound at least 50% of the time.
How would threshold testing using speech as a stimulus be different than using pure tunes?
We would not use the frequency dial at all, we would use the dB dial.
Pure-tone audiograms can tell you:
If a hearing loss exists
The extent of loss
The type of loss
But … Pure-tone audiograms do not tell you the degree of disability in speech communication that a person with a hearing loss has.
The biggest complaint a person with a hearing loss has is "Hearing and understanding speech"
Therefore, it is only logical that tests of hearing function be performed with speech stimuli
Categories of speech audiometric testing
Speech Threshold Testing
Speech-Detection Threshold Test
Can hear but cant understand
SDT- raise hand when they hear it
Speech-Recognition Threshold Test
SRT-
Speech Recognition Testing
Speech-Recognition Score
Presented 50 words and based on what they get right you will double the score
Word-Recognition Score
Supra-Threshold Measures
Most comfortable Loudness level
Uncomfortable Loudness Level
Dynamic Range
How reliable speech audiometry is depends on:
Equipment
Test environment
Patient responses
Clinician's role or examiner sophistication
Equipment: the diagnostic audiometer
Must be calibrated
There are inputs for microphones, CDs, and audiofiles presentation of the speech stimuli.
A VU (volume unit) meter is used to monitor the intensity of the input source visually
You can even provide masking to the NTE.
The Diagnostic Audiometer
Tests can be carried out in either ear individually- monaural
Or test can be carried out in both ears simultaneously- binaural
Test environment
Most speech audiometry is carried out with the patient isolated from the examiner in either a one or two room sound treated suite.
Ambient noise levels must be controlled
2 ways in which speech stimuli can be presented or delivered:
Monitored Live-Voice testing: This is when you introduce a speech signal through a microphone. The loudness of the voice is monitored visually using a VU meter.
Pre-recorded material : use of tapes, CDs, or audio-files in which words or sentences have already been recorded and are played for the patient.
Advantages to pre-recorded material
With pre-corded material where is consistency of presentation that is independent of the expertise of the clinician
Many audiologists prefer Monitored Live Voice testing because it provides them more flexibility in delivering the stimuli and it often takes less time.
Patient Responses
In speech audiometry, patients must know and understand reasonably well, the words with which they are being tested.
For example - if I say some foreign words to you that makes no sense, it would be harder for you to repeat it. You would be unsure about what you heard.
Depending on the type of tests, responses may be in the form of:
Oral reply: patient repeats "Baseball"
Written reply: writes the word "baseball"
Identify picture or object: show me the word "baseball"
Regardless of the test, the bottom line is the patient must understand what they're supposed to do!
Disadvantages to the oral response:
It is possible to misinterpret the patients response. Many patients have speech or language difficulties that make their responses difficult to understand.
Talk-back systems on many audiometers are often of poor quality. These create problems of interpreting responses.
Speech Audiometry Consists of Several Tests:
Speech Threshold Testing
The same principles use for pure tune testing are used for speech.
You try to obtain the patient's threshold for speech (like pure tones).
What is the definition of "threshold"?
The level at which speech is comprehended.
You compare it to the normal hearing person's threshold to determine the degree of loss for speech.
There are two types of threshold tests:
Speech detection threshold (SDT)
Speech Recognition Threshold (SRT)
Speech detection threshold (SDT):
Lowest level ( in dB) at which a subject can barely detect the presence of speech and identify it as speech
It is also known as Speech Awareness Threshold (SAT).
Does not mean that speech is understood, but its presence is detected.
You can use words, phrases, or sentences for finding the SDT.
Preferably sentences.
Sentences are read rapidly and monotonously.
The material should be uninteresting-
"Cold running speech".
Continuous discourse
It does not matter which ear you start with.
Patient can respond with hand signal, finger, signal button, et c.
They indicate the lowest level (dB HL) they hear/detect speech.
Speech Recognition Thresholds (SRT)
More popular than SDT and the preferred threshold test by most audiologists
SRT and PTA have a relationship status
With this test you are trying to find the lowest level at which speech can barely be understood.
Materials used:
Use of spondaic words which are often called spondee words (more common)
A spondee is a words with two syllables both pronounced with equal stress and effort
Hotdog
Baseball
Toothbrush
Ensure the patient is familiar with the testing vocabulary prior to the test.
Words that present any difficulty should be eliminated from the list
Spondees may be presented by:
MLV (monitored live voice)
Spoken into the microphone
Pre-recorded material
Introduced by tape, CD, or audiofiles
Both syllables of the word should peak at zero on the VU meter
Equal stress on both syllables.
Although it takes practice for the student to accomplish this equal peaking o the VU meter, most people can acquire the knack relatively quickly.
You can use a carrier phrase prior to each word. Example: say the word ___ followed y the stimulus word.
When do SRT testing
Instructions for the patient when administering the SRT:
The purpose of this test is to determine the faintest or softest level at which you can hear and repeat some words.
Each word you hear will have 2 syllables like "hotdog" or "baseball" and will be selected from the list of words given to you.
Each time you hear a word, I want you to repeat it.
Repeat the words even if they are very soft.
You may have to guess but repeat the word if you have any idea what it is .
Do you have any questions?
The PTA and SRT if they agree in the same range( 5 to 10 ) its probably a pretty reliable test