Comprehensive Radiographic Chest Positioning and Protocols Guide
Mobile Chest Radiography (AP Projection)
Technical Considerations:
- Nongrid exposure: (facility dependent).
- Grid exposure: (facility dependent).
- Source-to-Image Distance (SID): (dependent on patient position and facility preference).
Exposure Field Size / Collimation:
- crosswise: Often utilized as standard consideration, taking into account that lung capacity for ill and/or supine patients is reduced compared to ambulatory upright patients.
- lengthwise: Considered for patients with long lung dimensions.
Patient Positioning:
- Supine position: Employed for critically ill, ventilator-dependent, unconscious, or trauma patients.
- Semierect position: Elevated to a level tolerable for the patient.
- Nearly erect position.
- Positional preference: Semierect or erect positions are preferred over supine whenever possible to demonstrate air-fluid levels.
Centering & Central Ray (CR) Alignment:
- Centering landmark: Level of and Mid-Sagittal Plane (MSP).
- Positioning calculation: Measure inferior to the jugular notch to locate the centering level.
- Tube head alignment: The tube head must be adjusted so it is parallel to the angle of the Image Receptor (IR).
- Central Ray direction: Direct the CR perpendicularly to the IR.
- Distortion caveat: Semierect angles vary from patient to patient; any mismatch between the X-ray tube and the IR will result in anatomical distortion.
Image Receptor Marking & Annotations:
- Place the Right or Left marker superiorly above the corresponding shoulder.
- Required additional annotations: Document SID, patient position, and exposure time.
Breathing Instructions & Timing:
- Standard protocol: Double inspiration with breath hold after the second full inspiration.
- Unresponsive patients: Requires the technologist to observe the patient's respiratory phase and time the exposure manually.
Decubitus Chest Radiography (AP or PA Projection)
Projection Rationale & Selection:
- PA Projection: Preferred projection because placing the heart closer to the IR decreases cardiac magnification.
- AP Projection: May be easier to position and offers decreased Object-to-Image Receptor Distance (OID), depending on the patient's ability to elevate arms high enough to place the anterior surface closest to the IR.
Technical Considerations:
- Nongrid exposure: (facility dependent).
- Grid exposure: (facility dependent).
- Exposure control: Manual mAs or Automatic Exposure Control (AEC).
- Recommended SID: .
- Equipment setups: Upright Bucky, tabletop with nongrid IR, or tabletop with grid IR.
Exposure Field Size:
- lengthwise: Recommended for sthenic to asthenic patients.
- crosswise: Recommended for hypersthenic patients.
Patient Positioning & Pathological Considerations:
- Pathology-driven positioning: Position is dictated by whether the clinical question concerns free air or fluid.
- Fluid evaluation: Suspected fluid levels require the affected side to be positioned down (e.g., fluid suspected in the left lung requires a left lateral decubitus position with the left side down).
- Free air evaluation: Free air rises to the highest point, requiring the suspected side of concern to be positioned up (e.g., free air suspected in the left lung requires a right lateral decubitus position with the left side up).
- Stabilization duration: Patients must remain in the decubitus position for a minimum of prior to exposure to allow fluid or air to settle and establish an air/fluid line.
- Patient elevation build-up: Consider elevating the patient off the table surface using a pad or board to allow the IR to extend below the downside level of the patient, ensuring complete bilateral visualization of the lung fields.
- Stretcher setup: Decubitus views can be obtained with the patient positioned on a stretcher and centered to an upright Bucky.
- Upper extremities: Raise arms high above the head to clear them from superimposition over the lung fields.
- Head & posture: Patient looks straight ahead with the chin slightly elevated.
Centering:
- Centered at the level of and Mid-Sagittal Plane (MSP).
Image Receptor Marking:
- Position markers near the shoulder region for easy access and to avoid superimposing lung tissue.
- Place the anatomic marker in the upside shoulder region.
- Include a dedicated "side up" marker or an upward-facing arrow to explicitly designate the upside.
Breathing Instructions:
- Double inspiration with breath hold after the second full inspiration.
- Technologist visual monitoring: Actively watch the patient during breathing instructions and while walking away to initiate the exposure.
Inspiration and Expiration Chest Radiography (PA Projection)
Protocol & Projections:
- Protocol consists of PA chest projections: PA image taken on full Inspiration and PA image taken on full Expiration.
Technical Considerations:
- Voltage setting:
- Automatic Exposure Control (AEC): Select the outermost AEC cells when using an upright Bucky.
- Standard SID: .
Exposure Field Size Options:
- lengthwise: For sthenic or asthenic patients.
- crosswise: For hypersthenic patients.
- .
Patient Positioning:
- Patient stands erect, facing the upright Bucky.
- Shoulders are relaxed and chin elevated.
- Arms are wrapped around the board/Bucky to roll the scapulae forward and out of the lung fields.
Centering:
- Centered at the level of and Mid-Sagittal Plane (MSP).
Image Receptor Marking:
- Place Right or Left marker superiorly above the corresponding shoulder.
- Required annotation: Clear inclusion of text or annotation designating "inspiration" and "expiration" on the corresponding radiographs.
Breathing Instructions:
- Inspiration image: Double inspiration and hold breath after the second inspiration.
- Expiration image: Double breath and hold breath after the second expiration.
- Visual monitoring: Technologist must watch the patient during breathing commands and while moving to the exposure console.
Pediatric Chest Radiography (AP or PA Projection)
Protocol Configurations:
- Single View Order: AP or PA Chest image.
- Two-View Order: Includes AP or PA Chest image combined with a Left Lateral Chest image.
Technical Considerations:
- Technical factor: (dependent on nongrid vs. grid usage).
- Technique control: Manual mAs settings.
- Grid utilization thresholds:
- Nongrid IR: Utilized if the patient's anatomical part thickness is .
- Grid IR: Utilized if the patient's anatomical part thickness is .
- SID range: .
Exposure Field Size:
- or lengthwise, or smaller field sizes collimated to match pediatric patient dimensions.
Patient Positioning & Restraints:
- AP Supine Projection: Used with proper restraint devices if the pediatric patient is unable to maintain an upright position.
- PA Upright Projection: Used with proper restraint if the pediatric patient is size-appropriate for an immobilization device and capable of supporting their own head.
- Safety and quality: Proper restraint must be utilized to maintain child safety and to obtain high diagnostic image quality.
- Ambulatory pediatric patients: Patient may stand upright against the Bucky if age and physical capability permit.
Centering Landmarks by Projection:
- PA Projection: Centered at the level of (corresponding to the inferior scapular angle) and Mid-Sagittal Plane (MSP).
- AP Projection: Centered at the level of the nipple line and Mid-Sagittal Plane (MSP).
Image Receptor Marking:
- Right or Left marker placed superiorly above the corresponding shoulder.
Breathing & Timing Requirements:
- Young pediatric patients are unable to comply with verbal breathing commands.
- Technologist must observe the child's breathing cycle and manually time the exposure to coincide with the respiratory phase.
- Continuous surveillance: Keep eyes directly on the pediatric patient during the entire walk to the control panel and throughout the exposure.
- Exposure timing: Carefully time the exposure at the peak inspiration phase.
Pediatric Chest Radiography (Left Lateral Projection)
Protocol & Projections:
- Performed as part of a Two-View Pediatric Chest Protocol (combining AP or PA with Left Lateral).
Technical Considerations:
- Technical factor: (dependent on nongrid vs. grid usage).
- Control setting: Manual mAs.
- Grid utilization thresholds:
- Nongrid IR: Utilized if the patient's anatomical part thickness is .
- Grid IR: Utilized if the patient's anatomical part thickness is .
- SID range: .
Exposure Field Size:
- or lengthwise (with IR size or collimation tailored to patient size).
Patient Positioning & Restraints:
- Left Lateral Recumbent Position: Utilized with proper restraint if the child is unable to sit or stand upright.
- Upright Lateral Position: Utilized with proper restraint if the pediatric patient can support their head and fits appropriately within an immobilization device.
- Safety protocols: Restraints are essential for child safety and obtaining precise anatomical alignment.
- Ambulatory patients: Stand upright against the Bucky if age and capability allow.
Centering:
- Centered at the level of (inferior scapular angle) and Mid-Coronal Plane (MCP).
Image Receptor Marking:
- Place the Left (L) marker along the anterior surface of the patient.
Breathing Instructions:
- Technologists must continuously watch the patient and manually time the exposure to match the active respiratory phase when the pediatric patient cannot follow verbal breathing instructions.