USGS Rain-Simulator Infiltrometer Mass-Infiltration and Infiltration Rate Analysis

Overview of USGS Rain-Simulator Infiltrometer Experiment

USGS Rain-Simulator Infiltrometer Experiment Data Table

  • Experiment Type: United States Geological Survey (USGS) rain-simulator infiltrometer experiment.
  • Soil Classification: Sandy loam soil.
  • Simulated Rainfall Rate (ii): 20 cm/hr20\,\text{cm/hr}.
  • Instructor / Presenter: Dr Abdulkadir T. Shola.
  • Slide Reference Number: Page 70, Example 5.1.

Experimental Data

  • Recorded Variables:

    • Time Elapsed (tt) measured in minutes (min\text{min}).
    • Simulated Rainfall (PP) measured in centimeters (cm\text{cm}).
    • Measured Runoff (RR) measured in centimeters (cm\text{cm}).
  • Tabulated Experimental Measurements:

    • At t=0 mint = 0\,\text{min}: Simulated Rainfall P=0.00 cmP = 0.00\,\text{cm}, Measured Runoff R=0.00 cmR = 0.00\,\text{cm}.
    • At t=5 mint = 5\,\text{min}: Simulated Rainfall P=1.67 cmP = 1.67\,\text{cm}, Measured Runoff R=0.84 cmR = 0.84\,\text{cm}.
    • At t=10 mint = 10\,\text{min}: Simulated Rainfall P=3.33 cmP = 3.33\,\text{cm}, Measured Runoff R=1.76 cmR = 1.76\,\text{cm}.
    • At t=15 mint = 15\,\text{min}: Simulated Rainfall P=5.00 cmP = 5.00\,\text{cm}, Measured Runoff R=2.76 cmR = 2.76\,\text{cm}.
    • At t=20 mint = 20\,\text{min}: Simulated Rainfall P=6.67 cmP = 6.67\,\text{cm}, Measured Runoff R=3.77 cmR = 3.77\,\text{cm}.
    • At t=25 mint = 25\,\text{min}: Simulated Rainfall P=8.33 cmP = 8.33\,\text{cm}, Measured Runoff R=4.85 cmR = 4.85\,\text{cm}.
    • At t=30 mint = 30\,\text{min}: Simulated Rainfall P=10.00 cmP = 10.00\,\text{cm}, Measured Runoff R=5.93 cmR = 5.93\,\text{cm}.
    • At t=60 mint = 60\,\text{min}: Simulated Rainfall P=20.00 cmP = 20.00\,\text{cm}, Measured Runoff R=13.27 cmR = 13.27\,\text{cm}.
    • At t=90 mint = 90\,\text{min}: Simulated Rainfall P=30.00 cmP = 30.00\,\text{cm}, Measured Runoff R=21.15 cmR = 21.15\,\text{cm}.
    • At t=120 mint = 120\,\text{min}: Simulated Rainfall P=40.00 cmP = 40.00\,\text{cm}, Measured Runoff R=29.33 cmR = 29.33\,\text{cm}.
    • At t=150 mint = 150\,\text{min}: Simulated Rainfall P=50.00 cmP = 50.00\,\text{cm}, Measured Runoff R=37.87 cmR = 37.87\,\text{cm}.

Governing Infiltration Equations

  • Mass Infiltration (FF):   F(t)=P(t)−R(t)F(t) = P(t) - R(t)

    • F(t)F(t) is the cumulative mass infiltration (cm\text{cm}) at time tt.
    • P(t)P(t) is the accumulated simulated rainfall (cm\text{cm}) at time tt.
    • R(t)R(t) is the accumulated measured runoff (cm\text{cm}) at time tt.
  • Infiltration Rate (ff):   f=ΔFΔt×60 min/hrf = \frac{\Delta F}{\Delta t} \times 60\,\text{min/hr}

    • ff is the incremental infiltration rate (cm/hr\text{cm/hr}).
    • ΔF=F(t2)−F(t1)\Delta F = F(t_2) - F(t_1) is the change in cumulative infiltration (cm\text{cm}) over interval Δt=t2−t1\Delta t = t_2 - t_1 (min\text{min}).

Part (a): Mass-Infiltration Calculations and Results

  • Step-by-Step Cumulative Mass Infiltration Derivation:

    • At t=0 mint = 0\,\text{min}:     F(0)=0.00−0.00=0.00 cmF(0) = 0.00 - 0.00 = 0.00\,\text{cm}
    • At t=5 mint = 5\,\text{min}:     F(5)=1.67−0.84=0.83 cmF(5) = 1.67 - 0.84 = 0.83\,\text{cm}
    • At t=10 mint = 10\,\text{min}:     F(10)=3.33−1.76=1.57 cmF(10) = 3.33 - 1.76 = 1.57\,\text{cm}
    • At t=15 mint = 15\,\text{min}:     F(15)=5.00−2.76=2.24 cmF(15) = 5.00 - 2.76 = 2.24\,\text{cm}
    • At t=20 mint = 20\,\text{min}:     F(20)=6.67−3.77=2.90 cmF(20) = 6.67 - 3.77 = 2.90\,\text{cm}
    • At t=25 mint = 25\,\text{min}:     F(25)=8.33−4.85=3.48 cmF(25) = 8.33 - 4.85 = 3.48\,\text{cm}
    • At t=30 mint = 30\,\text{min}:     F(30)=10.00−5.93=4.07 cmF(30) = 10.00 - 5.93 = 4.07\,\text{cm}
    • At t=60 mint = 60\,\text{min}:     F(60)=20.00−13.27=6.73 cmF(60) = 20.00 - 13.27 = 6.73\,\text{cm}
    • At t=90 mint = 90\,\text{min}:     F(90)=30.00−21.15=8.85 cmF(90) = 30.00 - 21.15 = 8.85\,\text{cm}
    • At t=120 mint = 120\,\text{min}:     F(120)=40.00−29.33=10.67 cmF(120) = 40.00 - 29.33 = 10.67\,\text{cm}
    • At t=150 mint = 150\,\text{min}:     F(150)=50.00−37.87=12.13 cmF(150) = 50.00 - 37.87 = 12.13\,\text{cm}
  • Summary Table of Mass Infiltration (FF):

    • Time 0 min0\,\text{min}: F=0.00 cmF = 0.00\,\text{cm}
    • Time 5 min5\,\text{min}: F=0.83 cmF = 0.83\,\text{cm}
    • Time 10 min10\,\text{min}: F=1.57 cmF = 1.57\,\text{cm}
    • Time 15 min15\,\text{min}: F=2.24 cmF = 2.24\,\text{cm}
    • Time 20 min20\,\text{min}: F=2.90 cmF = 2.90\,\text{cm}
    • Time 25 min25\,\text{min}: F=3.48 cmF = 3.48\,\text{cm}
    • Time 30 min30\,\text{min}: F=4.07 cmF = 4.07\,\text{cm}
    • Time 60 min60\,\text{min}: F=6.73 cmF = 6.73\,\text{cm}
    • Time 90 min90\,\text{min}: F=8.85 cmF = 8.85\,\text{cm}
    • Time 120 min120\,\text{min}: F=10.67 cmF = 10.67\,\text{cm}
    • Time 150 min150\,\text{min}: F=12.13 cmF = 12.13\,\text{cm}
  • Mass-Infiltration Plotting Specifications:

    • Horizontal Axis (XX-axis): Time Elapsed (tt) in minutes (min\text{min}) from 00 to 150 min150\,\text{min}.
    • Vertical Axis (YY-axis): Mass Infiltration (FF) in centimeters (cm\text{cm}) from 0.000.00 to 12.13 cm12.13\,\text{cm}.
    • Curve Trajectory: Monotonically increasing curve with an initial steep slope that gradually flattens as soil moisture increases.

Part (b): Infiltration Rate Calculations and Results

  • Step-by-Step Incremental Infiltration Rate Derivations:

    • Interval 0−5 min0 - 5\,\text{min} (Δt=5 min\Delta t = 5\,\text{min}):     ΔF=0.83−0.00=0.83 cm\Delta F = 0.83 - 0.00 = 0.83\,\text{cm}f=0.83 cm5 min×60 min/hr=9.96 cm/hrf = \frac{0.83\,\text{cm}}{5\,\text{min}} \times 60\,\text{min/hr} = 9.96\,\text{cm/hr}

    • Interval 5−10 min5 - 10\,\text{min} (Δt=5 min\Delta t = 5\,\text{min}):     ΔF=1.57−0.83=0.74 cm\Delta F = 1.57 - 0.83 = 0.74\,\text{cm}f=0.74 cm5 min×60 min/hr=8.88 cm/hrf = \frac{0.74\,\text{cm}}{5\,\text{min}} \times 60\,\text{min/hr} = 8.88\,\text{cm/hr}

    • Interval 10−15 min10 - 15\,\text{min} (Δt=5 min\Delta t = 5\,\text{min}):     ΔF=2.24−1.57=0.67 cm\Delta F = 2.24 - 1.57 = 0.67\,\text{cm}f=0.67 cm5 min×60 min/hr=8.04 cm/hrf = \frac{0.67\,\text{cm}}{5\,\text{min}} \times 60\,\text{min/hr} = 8.04\,\text{cm/hr}

    • Interval 15−20 min15 - 20\,\text{min} (Δt=5 min\Delta t = 5\,\text{min}):     ΔF=2.90−2.24=0.66 cm\Delta F = 2.90 - 2.24 = 0.66\,\text{cm}f=0.66 cm5 min×60 min/hr=7.92 cm/hrf = \frac{0.66\,\text{cm}}{5\,\text{min}} \times 60\,\text{min/hr} = 7.92\,\text{cm/hr}

    • Interval 20−25 min20 - 25\,\text{min} (Δt=5 min\Delta t = 5\,\text{min}):     ΔF=3.48−2.90=0.58 cm\Delta F = 3.48 - 2.90 = 0.58\,\text{cm}f=0.58 cm5 min×60 min/hr=6.96 cm/hrf = \frac{0.58\,\text{cm}}{5\,\text{min}} \times 60\,\text{min/hr} = 6.96\,\text{cm/hr}

    • Interval 25−30 min25 - 30\,\text{min} (Δt=5 min\Delta t = 5\,\text{min}):     ΔF=4.07−3.48=0.59 cm\Delta F = 4.07 - 3.48 = 0.59\,\text{cm}f=0.59 cm5 min×60 min/hr=7.08 cm/hrf = \frac{0.59\,\text{cm}}{5\,\text{min}} \times 60\,\text{min/hr} = 7.08\,\text{cm/hr}

    • Interval 30−60 min30 - 60\,\text{min} (Δt=30 min\Delta t = 30\,\text{min}):     ΔF=6.73−4.07=2.66 cm\Delta F = 6.73 - 4.07 = 2.66\,\text{cm}f=2.66 cm30 min×60 min/hr=5.32 cm/hrf = \frac{2.66\,\text{cm}}{30\,\text{min}} \times 60\,\text{min/hr} = 5.32\,\text{cm/hr}

    • Interval 60−90 min60 - 90\,\text{min} (Δt=30 min\Delta t = 30\,\text{min}):     ΔF=8.85−6.73=2.12 cm\Delta F = 8.85 - 6.73 = 2.12\,\text{cm}f=2.12 cm30 min×60 min/hr=4.24 cm/hrf = \frac{2.12\,\text{cm}}{30\,\text{min}} \times 60\,\text{min/hr} = 4.24\,\text{cm/hr}

    • Interval 90−120 min90 - 120\,\text{min} (Δt=30 min\Delta t = 30\,\text{min}):     ΔF=10.67−8.85=1.82 cm\Delta F = 10.67 - 8.85 = 1.82\,\text{cm}f=1.82 cm30 min×60 min/hr=3.64 cm/hrf = \frac{1.82\,\text{cm}}{30\,\text{min}} \times 60\,\text{min/hr} = 3.64\,\text{cm/hr}

    • Interval 120−150 min120 - 150\,\text{min} (Δt=30 min\Delta t = 30\,\text{min}):     ΔF=12.13−10.67=1.46 cm\Delta F = 12.13 - 10.67 = 1.46\,\text{cm}f=1.46 cm30 min×60 min/hr=2.92 cm/hrf = \frac{1.46\,\text{cm}}{30\,\text{min}} \times 60\,\text{min/hr} = 2.92\,\text{cm/hr}

  • Summary Table of Infiltration Rate (ff):

    • Interval 0−5 min0 - 5\,\text{min} (Midpoint 2.5 min2.5\,\text{min}): f=9.96 cm/hrf = 9.96\,\text{cm/hr}
    • Interval 5−10 min5 - 10\,\text{min} (Midpoint 7.5 min7.5\,\text{min}): f=8.88 cm/hrf = 8.88\,\text{cm/hr}
    • Interval 10−15 min10 - 15\,\text{min} (Midpoint 12.5 min12.5\,\text{min}): f=8.04 cm/hrf = 8.04\,\text{cm/hr}
    • Interval 15−20 min15 - 20\,\text{min} (Midpoint 17.5 min17.5\,\text{min}): f=7.92 cm/hrf = 7.92\,\text{cm/hr}
    • Interval 20−25 min20 - 25\,\text{min} (Midpoint 22.5 min22.5\,\text{min}): f=6.96 cm/hrf = 6.96\,\text{cm/hr}
    • Interval 25−30 min25 - 30\,\text{min} (Midpoint 27.5 min27.5\,\text{min}): f=7.08 cm/hrf = 7.08\,\text{cm/hr}
    • Interval 30−60 min30 - 60\,\text{min} (Midpoint 45.0 min45.0\,\text{min}): f=5.32 cm/hrf = 5.32\,\text{cm/hr}
    • Interval 60−90 min60 - 90\,\text{min} (Midpoint 75.0 min75.0\,\text{min}): f=4.24 cm/hrf = 4.24\,\text{cm/hr}
    • Interval 90−120 min90 - 120\,\text{min} (Midpoint 105.0 min105.0\,\text{min}): f=3.64 cm/hrf = 3.64\,\text{cm/hr}
    • Interval 120−150 min120 - 150\,\text{min} (Midpoint 135.0 min135.0\,\text{min}): f=2.92 cm/hrf = 2.92\,\text{cm/hr}
  • Infiltration Rate Plotting Specifications:

    • Horizontal Axis (XX-axis): Time Elapsed (tt) in minutes (min\text{min}).
    • Vertical Axis (YY-axis): Infiltration Rate (ff) in centimeters per hour (cm/hr\text{cm/hr}).
    • Plotting Method: Plotted either as a continuous curve through interval midpoints or as horizontal step blocks across each time increment.
    • Curve Trajectory: Classic Horton-type decay curve starting from initial high rate f0≈9.96 cm/hrf_0 \approx 9.96\,\text{cm/hr} towards an asymptotic ultimate equilibrium rate fc<3.00 cm/hrf_c < 3.00\,\text{cm/hr}.