Fundamentals of Parallel Thermal Resistance Networks
Thermal resistance analysis extends the electrical circuit analogy to heat transfer across multiple materials. When heat conducts simultaneously through adjacent materials situated side by side along the path of heat flow, the arrangement is defined as a parallel network.
In a parallel configuration, the heat transfer rate divides among the parallel branches while the temperature drop across each parallel component remains identical:
Q=Q1+Q2
The rate of heat transfer through any thermal network is expressed by the general thermal resistance equation:
Q=RtotalΔT
Where:
Q is the total heat transfer rate, expressed in watts (W) or kilowatts (kW).
ΔT is the overall temperature difference driving the heat flow (ΔT=Thigh−Tlow), expressed in degrees Celsius (∘C) or Kelvin (K).
Rtotal is the total equivalent thermal resistance of the network, expressed in degrees Celsius per watt (∘C/W) or Kelvin per watt (K/W).
For two conductive layers arranged in parallel between isothermal surfaces at temperatures T1 and T2 (where T1>T2):
Rtotal1=R11+R21
Algebraic rearrangement yields the equivalent resistance for two parallel components:
Rtotal=R1∥R2=R1+R2R1R2
The conductive thermal resistance of an individual layer is determined by its thickness, thermal conductivity, and cross-sectional area:
R1=k1A1L1
R2=k2A2L2
Where:
L is the material thickness along the direction of heat transfer in meters (m).
k is the thermal conductivity in watts per meter-degree Celsius (W/(m⋅∘C)) or watts per meter-Kelvin (W/(m⋅K)).
A is the cross-sectional heat transfer area normal to the direction of heat transfer in square meters (m2).
In parallel arrangements, the individual material layers often possess different cross-sectional areas (A1=A2) due to differing vertical dimensions or heights (H1=H2), even though their thicknesses (L) along the heat flow path may be identical.
Combined Series-Parallel Thermal Circuits
Engineering systems frequently combine series layers and parallel layers within composite structures, incorporating both conductive solid layers and convective fluid boundaries.
To analyze a combined series-parallel network:
Construct the complete thermal circuit diagram identifying all thermal nodes (temperatures) and resistance elements.
Formulate the total equivalent thermal resistance expression by reducing parallel groups into single equivalent resistances, then summing all components in series.
Apply the general resistance equation using the global temperature boundary conditions.
Consider a composite wall where parallel materials 1 and 2 are bounded on the left by surface temperature T1 and interface temperature T2, connected in series to solid material 3 (spanning from T2 to T3), which transfers heat via convection from outer surface T3 to an ambient fluid at T∞ with convection heat transfer coefficient h:
Rtotal=(R1∥R2)+R3+Rconv
Expanding each individual resistance component:
R1∥R2=R1+R2R1R2
R1=k1A1L1
R2=k2A2L2
R3=k3A3L3
Rconv=hAconv1
The surface area for convection (Aconv) must correspond strictly to the physical surface interfacing with the moving fluid. Because material 3 covers the combined outer face of the composite structure, its area equals the total exposed frontal area:
A3=A1+A2
Aconv=A3
Once the total resistance is established, the total heat transfer rate across the system is given by:
Q=RtotalT1−T∞
Intermediate local temperatures can be solved using local energy balances across specific subsections of the network:
Q=R1∥R2T1−T2
Q=(R1∥R2)+R3T1−T3
Q=RconvT3−T∞
Analysis of Series-Parallel Composite Wall Example
Consider steady, one-dimensional heat conduction across a composite slab composed of four distinct material blocks designated A, B, C, and D. Heat flows horizontally in the positive x-direction from the left surface to the right surface without surface convection.
Given Parameters:
Left surface temperature: T1=370∘C
Right surface temperature: T4=66∘C
Cross-sectional area of material C: AC=0.1m2
Area relationships: AB=AD=21AC=0.05m2
Area of material A: Material A shares the full height of material C, yielding AA=AC=0.1m2
Thickness of layer A: LA=2.5cm=0.025m
Thickness of parallel layers B and D: LB=LD=7.5cm=0.075m
Thermal Circuit Architecture:
Node T1: Outer surface of material A.
Node T2: Interface between material A and the parallel block containing materials B and D.
Node T3: Interface between the parallel block (B and D) and material C.
Node T4: Outer surface of material C.
The equivalent total thermal resistance of the composite system is:
Rtotal=RA+(RB∥RD)+RC
Rtotal=RA+RB+RDRBRD+RC
Individual conductive resistances are computed after converting all linear dimensions to meters:
RA=kAAALA=kA(0.1)0.025
RB=kBABLB=kB(0.05)0.075
RD=kDADLD=kD(0.05)0.075
RC=kCACLC
The total heat transfer rate through the composite assembly is:
Q=RtotalT1−T4
To determine the unknown interface temperature T3, utilize the heat flow through material C alone:
Q=RCT3−T4
T3=T4+Q⋅RC
Periodic Composite Structures: Brick Wall with Plaster and Insulation
A representative recurring cross-section (unit cell) approach is utilized when walls consist of repetitive geometric patterns in the vertical direction.
Overall Wall Specifications:
Wall height: Hwall=3m
Wall width: Wwall=5m
Total wall face area: Awall=Hwall×Wwall=3m×5m=15m2
Internal Layer and Material Data:
Horizontal brick core dimensions: 16cm vertical height by 22cm horizontal thickness (Lbrick=0.22m).
Thermal conductivity of brick: kbrick=0.72W/(m⋅∘C).
Plaster separation: Bricks are separated horizontally by 3cm thick plaster layers (allocating 1.5cm above and 1.5cm below each brick within a symmetric unit cell).
Lateral plaster layers: 2cm thick vertical plaster layers on both sides of the brick core (LP,1=LP,4=0.02m).
Thermal conductivity of plaster: kplaster=0.22W/(m⋅∘C).
Rigid foam insulation layer: 3cm thick (Lfoam=0.03m) situated on the indoor side.
Thermal conductivity of foam: kfoam=0.026W/(m⋅∘C).
Thermal Boundaries:
Indoor air temperature: T∞,1=20∘C
Outdoor air temperature: T∞,2=−10∘C
Inner convection heat transfer coefficient: h1=10W/(m2⋅∘C)
Outer convection heat transfer coefficient: h2=25W/(m2⋅∘C)
Assumptions: Steady-state, one-dimensional heat flow, negligible radiation effects.
Unit Cell Characterization: The repeating pattern recurs every 25cm (0.25m) in the vertical direction. Assuming a unit depth of W=1m into the page:
Hcell=0.25m
Acell=0.25m×1.0m=0.25m2
Layer Subdivision of the Unit Cell (Indoor to Outdoor):
Indoor convection: Rconv,1
Rigid foam layer (F): LF=0.03m, AF=0.25m2
Inner plaster layer (P1): LP,1=0.02m, AP,1=0.25m2
Parallel core layer (L=0.22m) consisting of three parallel branches:
Top plaster section (P2): Height =1.5cm=0.015m, area AP,2=0.015m×1.0m=0.015m2
Central brick (B): Height =16cm=0.16m, area AB=0.16m×1.0m=0.16m2
Bottom plaster section (P3): Height =1.5cm=0.015m, area AP,3=0.015m×1.0m=0.015m2
Outer plaster layer (P4): LP,4=0.02m, AP,4=0.25m2
Outdoor convection: Rconv,2
Unit Cell Resistance Equations:
Rconv,1=h1Acell1=(10)(0.25)1
RF=kfoamAcellLF=(0.026)(0.25)0.03
RP,1=kplasterAcellLP,1=(0.22)(0.25)0.02
Rparallel1=RP,21+RB1+RP,31
Where:
RP,2=kplasterAP,2Lbrick=(0.22)(0.015)0.22
RB=kbrickABLbrick=(0.72)(0.16)0.22
RP,3=kplasterAP,3Lbrick=(0.22)(0.015)0.22
RP,4=kplasterAcellLP,4=(0.22)(0.25)0.02
Rconv,2=h2Acell1=(25)(0.25)1
Total Unit Cell Resistance:
Rtotal, cell=Rconv,1+RF+RP,1+Rparallel+RP,4+Rconv,2
Heat Transfer Rate of the Unit Cell:
Qcell=Rtotal, cellT∞,1−T∞,2=Rtotal, cell20−(−10)=Rtotal, cell30
Total Heat Transfer Rate Across Entire Wall: The total heat transfer rate across the entire wall is calculated by scaling the unit cell heat transfer rate by the ratio of the total wall area to the unit cell area:
Ncells=AcellAwall=0.25m215m2=60
Qtotal=Ncells×Qcell=60×Qcell