Introduction to Closed Chest Drainage Systems

  • Purpose: To provide an overview of the management of clients with closed chest drainage systems.

  • Importance: Emphasizes the significance of accessing the complete module, which includes various interactive activities and visual aids like illustrations and tables.

  • Assessment: Pretest and posttest available for knowledge assessment prior to and after engaging with the material.

Types of Closed Chest Drainage Systems

  • Insertion Purpose: Chest tubes are used to restore a collapsed lung or drain fluid from the pleural cavity.

  • Connection System: The tubing connects to a sealed drainage system or one-way valve that allows the removal of air and fluid while preventing air from entering to avoid tension pneumothorax.

Sealed Drainage Systems
  • Single Chamber: Collects small drainage amounts providing a water seal.

    • Mechanism: Fluid rises upon inhalation and descends upon exhalation.

  • Two Chamber System: For larger amounts or more accurate fluid measurements.

    • Mechanism: Air flows into the water seal chamber while fluid flows into the collection chamber.

Operational Principles
  • Controlled Suction: Draws air/fluid from the pleural space; chest tube connects directly to collection chamber in disposable three-chamber systems.

  • Calibrated Collection Chamber: For measuring drainage.

    • Features a radon surface for documenting time, date, and amount of fluid.

  • Water Seal Chamber Functions:

    • Allows air to exit on exhalation and prevents air entry on inhalation.

  • Setup Requirements: Follow manufacturer directions for filling the water seal chamber with sterile fluid, typically maintaining it at about 2 centimeters.

Monitoring Water Seal Chamber
  • Tidaling: Water level fluctuates with breathing, rising with inhalation and returning to baseline with exhalation (5-10 cm expected).

  • Bubbling Indicators: Occasional bubbling is normal; continuous bubbling indicates an air leak.

  • Air Leak Meter: Newer systems may have meters indicating the degree of air leaking based on numbered columns.

Measuring Negative Pressure
  • Calibrated Manometer: Measures negative pressure; water level rises with increased negativity in the pleural cavity.

  • Positive Pressure Ventilation Observation: Fluid level falls on inhalation and rises on exhalation when positive pressure is applied.

Closed Chest Drainage System Types

  • Air Leak Detection Chamber: Checks for air leaks through fluid instillation or by tipping the system.

  • Suctions Control: Traditional wet suction regulates suction by water level, typically at 20 cm for adults.

  • Dry Suction Control Systems: No need for fluid replacement; quieter operation with adjustable dials for suction pressure levels.

  • Autologous Blood Collection: For clients with potential blood loss, some systems feature a pump port.

Mobile Chest Drains

  • Heimlich Valve: A one-way flutter valve for small pneumothoraxes; directs airflow out but not back in.

  • Pneumostat: For collecting fluid; allows air to exit but prevents air backflow.

Indications for Closed Chest Drainage

  • Purpose of Pleural Space: Contains lubricating fluid, allowing pleurae to move smoothly in respiration.

  • Fluid Accumulation Causes: Trauma (hemothorax, kylothorax), heart failure (transudates, exudates), cirrhosis, malignancies.

  • Understanding Pneumothorax: Air collecting leads to lung collapse; tension pneumothorax is a medical emergency resulting in impaired venous return and potential respiratory compromise.

Maintenance of a Closed Chest Drainage System

  • Monitoring Factors: Varies with client status, activity level, response; critical for unstable clients or high drainage amounts.

  • Vital Signs Monitoring: Frequent checks including oxygen saturation, pain level, and breath sounds.

  • Chest Tube Dressing Assessment: Check every four hours for drainage and palpate for crepitus.

  • Fluid Level Assessment: Collect chamber levels should be monitored at least every hour, especially post initial hours.

  • Managing Water Seal Chamber Levels: Ensure adequate fluid, typically need to refill due to evaporation.

Troubleshooting and Interventions for Air Leaks

  • Continuous Bubbling Observation: Signals possible air leak; methodical assessment is required.

  • Fluctuations Stopping in Water Seal Chamber: May indicate obstruction; requires checking for dependent loops or kinked tubing.

  • Intervention Techniques: If air leak suspected, momentarily clamp the tubing or perform chest tube dressing assessments.

Post-Operative Considerations for Chest Tubes

  • Factors Influencing Drainage Amounts: Expected output of 100-300 ml in first few hours; report excessive drainage.

  • Position Changes Requirements: Progressively vital to facilitate drainage; frequent checks should be documented.

Implementing Evidence-Based Practices

  • Dressing Site Studies: Balancing dressing types for pain vs. drainage stability.

  • Active Clearance for Chest Tubes: Improving outcomes in retained blood management.

  • Common Best Practice Protocols: Frequency of assessment and dressing changes should follow institutional guidelines.

Conclusion

a. Summary of Key Points: Aim to maintain ventilatory function and ensure stability of the closed chest drainage system is critical for recovery.
b. Documentation Standards: Encompasses a wide range of necessary data from client's responses, and care actions to specifics regarding chest tube management.