ATI Skilled Module for Closed Chest Drainage System 🫗
ATI Skilled Module for Closed Chest Drainage System
Introduction to Closed Chest Drainage Systems
Purpose: To provide an overview of the management of clients with closed chest drainage systems.
Importance: Emphasizes the significance of accessing the complete module, which includes various interactive activities and visual aids like illustrations and tables.
Assessment: Pretest and posttest available for knowledge assessment prior to and after engaging with the material.
Types of Closed Chest Drainage Systems
Insertion Purpose: Chest tubes are used to restore a collapsed lung or drain fluid from the pleural cavity.
Connection System: The tubing connects to a sealed drainage system or one-way valve that allows the removal of air and fluid while preventing air from entering to avoid tension pneumothorax.
Sealed Drainage Systems
Single Chamber: Collects small drainage amounts providing a water seal.
Mechanism: Fluid rises upon inhalation and descends upon exhalation.
Two Chamber System: For larger amounts or more accurate fluid measurements.
Mechanism: Air flows into the water seal chamber while fluid flows into the collection chamber.
Operational Principles
Controlled Suction: Draws air/fluid from the pleural space; chest tube connects directly to collection chamber in disposable three-chamber systems.
Calibrated Collection Chamber: For measuring drainage.
Features a radon surface for documenting time, date, and amount of fluid.
Water Seal Chamber Functions:
Allows air to exit on exhalation and prevents air entry on inhalation.
Setup Requirements: Follow manufacturer directions for filling the water seal chamber with sterile fluid, typically maintaining it at about 2 centimeters.
Monitoring Water Seal Chamber
Tidaling: Water level fluctuates with breathing, rising with inhalation and returning to baseline with exhalation (5-10 cm expected).
Bubbling Indicators: Occasional bubbling is normal; continuous bubbling indicates an air leak.
Air Leak Meter: Newer systems may have meters indicating the degree of air leaking based on numbered columns.
Measuring Negative Pressure
Calibrated Manometer: Measures negative pressure; water level rises with increased negativity in the pleural cavity.
Positive Pressure Ventilation Observation: Fluid level falls on inhalation and rises on exhalation when positive pressure is applied.
Closed Chest Drainage System Types
Air Leak Detection Chamber: Checks for air leaks through fluid instillation or by tipping the system.
Suctions Control: Traditional wet suction regulates suction by water level, typically at 20 cm for adults.
Dry Suction Control Systems: No need for fluid replacement; quieter operation with adjustable dials for suction pressure levels.
Autologous Blood Collection: For clients with potential blood loss, some systems feature a pump port.
Mobile Chest Drains
Heimlich Valve: A one-way flutter valve for small pneumothoraxes; directs airflow out but not back in.
Pneumostat: For collecting fluid; allows air to exit but prevents air backflow.
Indications for Closed Chest Drainage
Purpose of Pleural Space: Contains lubricating fluid, allowing pleurae to move smoothly in respiration.
Fluid Accumulation Causes: Trauma (hemothorax, kylothorax), heart failure (transudates, exudates), cirrhosis, malignancies.
Understanding Pneumothorax: Air collecting leads to lung collapse; tension pneumothorax is a medical emergency resulting in impaired venous return and potential respiratory compromise.
Maintenance of a Closed Chest Drainage System
Monitoring Factors: Varies with client status, activity level, response; critical for unstable clients or high drainage amounts.
Vital Signs Monitoring: Frequent checks including oxygen saturation, pain level, and breath sounds.
Chest Tube Dressing Assessment: Check every four hours for drainage and palpate for crepitus.
Fluid Level Assessment: Collect chamber levels should be monitored at least every hour, especially post initial hours.
Managing Water Seal Chamber Levels: Ensure adequate fluid, typically need to refill due to evaporation.
Troubleshooting and Interventions for Air Leaks
Continuous Bubbling Observation: Signals possible air leak; methodical assessment is required.
Fluctuations Stopping in Water Seal Chamber: May indicate obstruction; requires checking for dependent loops or kinked tubing.
Intervention Techniques: If air leak suspected, momentarily clamp the tubing or perform chest tube dressing assessments.
Post-Operative Considerations for Chest Tubes
Factors Influencing Drainage Amounts: Expected output of 100-300 ml in first few hours; report excessive drainage.
Position Changes Requirements: Progressively vital to facilitate drainage; frequent checks should be documented.
Implementing Evidence-Based Practices
Dressing Site Studies: Balancing dressing types for pain vs. drainage stability.
Active Clearance for Chest Tubes: Improving outcomes in retained blood management.
Common Best Practice Protocols: Frequency of assessment and dressing changes should follow institutional guidelines.
Conclusion
a. Summary of Key Points: Aim to maintain ventilatory function and ensure stability of the closed chest drainage system is critical for recovery.
b. Documentation Standards: Encompasses a wide range of necessary data from client's responses, and care actions to specifics regarding chest tube management.