IV Cannulation
PROCEDURE:
Verify the written prescription for IV therapy. Check prepared IVF and other things needed. Rationale: To ensure safe and correct administration of IV therapy to the right patient.
Explain procedure to reassure the patient and significant others. Observe the 10 rights of medication administration. Rationale: To gain client participation and cooperation
Prepare needed equipment. Rationale: Saves time and energy
Do hand hygiene and wear gloves before the procedure. Rationale: Deter the spread of infectious microorganism
Choose site for IV. Rationale: Ensures adequate vein that is easy to puncture and less likely to rupture
Apply tourniquet 2-6 inches above injection site. Rationale: Pressure of the tourniquet causes the vein to engorge
Prepare site with topical anesthetic or cotton balls soaked with alcohol in circular motion. Allow 30 seconds to dry. Rationale: Reduces microbial count in the skin
Check for pulse below tourniquet. Rationale: Ensures blood flow of the vein
Use appropriate IV cannula, pierce the skin with needle positioned on 15-30 degree angle. Rationale: Superficial veins requires smaller angle.
Upon flashback visualization, decrease the angle, advance the catheter and the stylet ¼ inch into the vein. Check the tip of catheter can be rotated freely inside the vein. Rationale: Allows full penetration of the vein wall.
Position the IV catheter parallel to the skin. Hold stylet stationary and slowly advance the catheter until the hub is 1mm to the puncture site. Rationale: Allows full penetration to the vein
Release tourniquet, remove the stylet while applying digital pressure over the catheter with one finger about 1-2 inch from the tip of the IV catheter. Rationale: Permits venous flow and reduces backflow of blood.
Connect the infusion tubing of the prepared IVF to the catheter aseptically. Rationale: Permits free flow of the IV fluid to the bloodstream.
Open the calm and regulate the flow rate. Rationale: Permits free flow of the IV fluid to the bloodstream.
Anchor needle in place with the use of transparent tape or dressing on the puncture site. Rationale: Prevents accidental dislodgement and protects the site from bacterial contamination
Tape a small loop of IV tubing. Rationale: Prevents tubing to be easily dislodged.
Calibrate the IVF bottle and regulate flow of infusion according to prescribed duration. Rationale: Permits free flow of the IV fluid to the bloodstream.
Label IV site with a tape to indicate the date of insertion, type, and gauge of IV catheter and countersign. Rationale: Allows recognition of type of device and length of the device in place.
Label with plaster on IV tubing to indicate the date when to change the IV tubing. Rationale: Allows recognition of type of device and length of the device in place.
Observe patient and report any untoward effect. Rationale: For the continual of care.
Document in the patient’s chart and endorse to incoming shift. Rationale: For the continual of care.
Discard sharps and wastes to appropriate receptacle. Do handwashing. Rationale: Prevents needlestick injuries and cross contamination.