University Study Notes: Reinforced Concrete Design to Eurocode 2
Introduction to Reinforced Concrete Design and Material Properties
The Design Process: Design is characterized by an iterative loop across three main stages:
- Conceptual Design: Establishing the design brief, ground conditions, building usage (insulation, fire, performance), and evaluating alternative structural forms and materials.
- Preliminary Design: Using approximate hand calculations, span-to-depth ratios, and layout sketches to assess the viability of conceptual solutions.
- Detailed Design: Full structural analysis and refinement of calculations, resulting in documentation for cost and construction.
Sustainability and HS&O (Health, Safety, and Welfare):
- Sustainability: Concrete provides high thermal mass for energy efficiency and can utilize waste products like fly ash. Locally sourced materials reduce CO2 emissions.
- HS&W: Complies with the Construction Design and Management (CDM) regulations. Designers must eliminate hazards and reduce risks during the design phase.
Composite Action Principles:
- Concrete is strong in compression but weak in tension (tension strength is approximately 10% of compression strength).
- Steel provides tensile strength and shear resistance.
- Strain Compatibility: Assuming a perfect bond (often enhanced by ribbed bars), the strain in the steel reinforcement is identical to the strain in the adjacent concrete: .
- Thermal Expansion: Coefficients are similar for both materials ( to per degree Celsius), preventing bond failure from differential expansion.
Concrete Material Properties:
- Strength Classes: Based on the 28-day characteristic cylinder strength (). For example, Class C25/30 has a cylinder strength of and a cube strength of .
- Modulus of Elasticity (): The secant modulus is used for short-term effects. The relationship with the dynamic modulus () is approximated as: .
- Creep: Continuous deformation under sustained load. Final deformation can be 3 to 4 times the initial elastic deformation.
- Shrinkage: Caused by hydration heat and moisture loss. Calculated steel stress () due to restrained shrinkage: , where .
Limit State Design Principles
Primary Limit States:
- Ultimate Limit State (ULS): Ensures safety against collapse, buckling, or overturning.
- Serviceability Limit State (SLS): Focuses on limiting deflection, cracking, vibration, and ensuring durability and fire resistance.
Characteristic Values:
- Characteristic Strength (): The value below which 5% of test results are expected to fall: .
- Characteristic Actions: Divided into Permanent () and Variable (). Wind () is treated as a separate variable category.
Partial Safety Factors ():
- Materials (): For ULS Persistent/Transient: Concrete = , Steel = . For Accidental: Concrete = , Steel = .
- Actions ():
- Unfavourable Permanent () = .
- Favourable Permanent () = .
- Unfavourable Leading Variable () = .
Load Combinations (SLS):
- Combination Value: .
- Frequent Value: .
- Quasi-permanent Value: .
Structural Analysis of Reinforced Concrete
- Analysis Methods: Includes moment and shear coefficients, manual moment distribution, and computer-aided frame analysis.
- Moments and Shears in Beams:
- Span AB uniform load () shear: .
- Maximum span moment occurs at zero shear: .
- Redistribution of Moments: EC2 allows an elastic analysis to be modified to account for plastic behavior.
- Required for ductility: Neutral axis depth () is restricted based on redistribution (): .
- UK Annex values: , . Standard EC2 values: , .
Analysis of the Section
- Rectangular Stress Block: Simplified for ULS design. Depth , with uniform stress .
- Singly Reinforced Sections:
- Non-dimensional factor: .
- Lever arm: .
- Limiting for concrete classes up to C50/60 (where ).
- Area of steel: .
- Doubly Reinforced Sections ():
- Compression steel area: .
- Tension steel area: .
- Flanged Sections (T and L beams):
- Effective width (): , where .
- Stress block usually lies in the flange. If , web compression must be calculated.
Shear, Bond, and Torsion
- Shear Design (Variable Strut Inclination):
- Diagonal concrete strut angle () is limited: .
- Maximum resistance (concrete crushing): .
- Shear links area: .
- Additional longitudinal force due to shear: .
- Anchorage and Laps:
- Basic anchorage length: .
- Ultimate bond stress: .
- Laps: .
- Torsion: Based on a thin-walled box model.
- Shear flow: .
- Additional longitudinal steel: .
Serviceability Requirements
- Cover for Durability and Fire: Nominal cover .
- based on exposure class (XC, XD, XS, XF, XA) and structural class.
- Standard fire resistance periods (R60 to R240) determine minimum member dimensions and axis distances ().
- Deflection Control: Managed via span-to-effective depth ratios ().
- Basic ratio depends on reinforcement ratio (). Limiting ratio = Basic Ratio Correction Factors.
- Correction factors account for span > 7m, flanged sections, and excess reinforcement.
- Crack Control:
- Max crack width () is usually (building) or (prestressed/water tanks).
- .
- Maximum crack spacing: .
Prestressed Concrete
- Methods:
- Pre-tensioning: Tendons stretched before casting; force transferred by bond.
- Post-tensioning: Tendons tensioned against hardened concrete; force transferred by mechanical anchors.
- Serviceability Analysis: Stresses must stay within limits at transfer and service.
- Magnel Diagram: A graphical tool plotting against eccentricity () to find a solution that satisfies all four stress inequalities.
- Prestress Losses: Calculated for elastic shortening, creep, shrinkage, steel relaxation, and (for post-tensioning) friction and anchorage slip.
Foundations and Retaining Walls
- Pad Footings: Sized for uniform soil pressure . Reinforced for bending and checked for punching shear at from the column face.
- Piled Foundations: Vertical loads distributed based on group geometry: .
- Retaining Walls: Analysis includes stability against overturning () and sliding ().