Positioning 2
Chest Radiography Overview and Clinical Competencies
Rib Anatomy and Relationships:
Rib 1 travels a short path originating near the top of the thoracic cavity.
Rib 2 is situated directly inferior to Rib 1.
Patient Transfer Protocols:
Patient transfers commonly occur from an ambulance stretcher directly to an Emergency Room (ER) stretcher.
Most non-ambulatory chest radiographic procedures are performed directly with the patient remaining on a stretcher.
Competency Requirements:
The chest radiography category encompasses multiple required clinical competencies, including PA, Lateral, and AP projections.
Clinical chest competencies must be completed on real patients by the end of the senior year.
Chest competencies are generally not completed via simulation.
Radiographic Centering, Positioning, and Respiration
Patient Alignment and Scapular Displacement:
Center the patient's midsagittal plane (MSP) perpendicular to the center of the Image Receptor (IR).
Roll the patient's shoulders forward to move the scapulae laterally out of the lung fields.
Image Receptor Orientation Criteria:
Lengthwise IR placement: Adjust the light field and IR so that it extends to above the top level of the patient's relaxed shoulders.
Crosswise IR placement: Ensure the top edge of the IR is positioned at least above the top level of the relaxed shoulders.
Sternum Alignment and Central Ray Relationships:
The Central Ray (CR) is perpendicular to the IR, while standard anatomical orientation maintains a natural angle of the sternum relative to the IR.
If the patient's sternum is aligned completely parallel to the IR surface without its normal angle, the patient's posture is incorrect, resulting in non-diagnostic imagery.
Respiration Protocols and Clinical Exceptions:
Standard Respiration: Exposure is taken on the second full inspiration (the patient takes a deep breath, exhausts it, takes a second deep breath, and holds it).
Stretcher Chest Exception: Severely ill patients experiencing respiratory distress or dyspnea may not tolerate holding a second deep inspiration; clinical leeway allows the exposure to be taken on a single breath if necessary.
Anatomical Visualization and Image Evaluation
Required Anatomical Structures on Standard Chest Images:
Complete visualization of both lungs in their entirety, extending from the apices superiorly down to the costophrenic angles inferiorly.
Clear cardiac shadow outline.
Visualization of the aortic notch.
Complete visualization of the mediastinum.
Clear identification of upper rib anatomy, specifically viewing around the 3rd rib anteriorly (counting 1st, 2nd, and 3rd ribs).
Centering Landmarks, Measurement Techniques, and Rotation Criteria
Superior Centering Anatomical Landmarks:
Standard CR entrance for AP chest projections is located below the jugular notch (also referred to as the manubriosternal or manubrial notch).
Anatomical Finger Measurement Method ("Alice's Fingers Technique"):
Radiographers frequently calibrate their own finger widths to locate the CR entrance point quickly without external measuring devices.
Standard baseline measurement: A four-finger width commonly measures .
Variable anatomical adjustment: Individual hand sizes vary (e.g., Alice's fingers are larger, meaning three finger-widths may equal , or two fingers equal ).
Practical application: Place the top finger at the bend of the jugular notch; the CR enters directly inline with the finger marking the calculated landmark below.
Determining Image Rotation:
The position of the clavicles serves as the primary indicator for rotation.
The sternal (medial) ends of the clavicles must be equidistant from the center line of the vertebral column.
Apical Evaluation and Clinical Indications
Diagnostic Quality Criteria for Standard AP Images:
Visualization of lung apices and costophrenic angles free of clipping.
Medial ends of the clavicles situated equidistant from the spinal column to verify absence of rotation.
Minimum rib visualization: Displaying at least 9 posterior ribs above the diaphragm level (counted sequentially 1, 2, 3, 4, 5, 6, 7, 8, 9).
Clinical Indications for AP Axial / Lordotic Projections:
Ordered specifically to evaluate suspected pathology, opacities, or lesions in the apical region of the lungs.
Used when a potential lesion is noted in the apical field to differentiate among:
Artefactual foamy/dense pulmonary secretions.
Overlying bone pathology on a rib.
Overlying bone pathology on the clavicle.
True parenchymal mass or lesion situated within the lung tissue itself.
AP Axial Lordotic Projection: Patient Posture Method
Purpose:
Projects the overlying clavicles superiorly above the lung apices, allowing unobscured visualization of the apical regions.
Patient Setup and Posture:
Patient stands upright facing the X-ray tube in an AP stance, positioned approximately () forward from the vertical bucky or grid cabinet.
Midsagittal plane (MSP) is centered to the midline of the vertical grid/bucky.
Patient steps forward and leans backward until the shoulders rest against the front face of the bucky/IR.
The mid-coronal plane forms a to angle relative to the vertical image receptor.
Central Ray (CR) Entrance and Direction:
Central Ray Angle: Perpendicular to the image receptor.
Entrance Point: Enters the MSP at a point to inferior to the manubrial/jugular notch.
Anatomical Effect:
Elongates the clavicles and projects them superior to the lung apices.
Diagnostic Utility and Technical Features of Lordotic Views
Comparison with Standard AP Projections:
Utilizes identical anatomical landmarks (jugular notch, MSP) as a standard AP chest projection, with the difference being the backward lordotic lean of the patient.
Breathing Instructions: Deep breath taken in twice, holding on the second full inspiration.
Image Receptor Placement: Typically oriented crosswise, especially for larger or hypersthenic patient builds.
Diagnostic Value Scope:
The main image body has low diagnostic value outside of the apical regions due to extreme anatomical distortion.
Specifically diagnostic for showing apical air-fluid levels, sternal structures, and medial clavicular ends.
Medial ends of the clavicles must remain equidistant from the vertebral column to confirm absence of rotation.
Alternative AP Axial Projection: Angled Central Ray Method
Clinical Indication:
Used when a patient is unable to stand and lean backward in a lordotic posture from the standing mark (e.g., weak, unsteady, or debilitated patients).
Angled Tube Positioning Method:
Patient stands upright or sits straight against the upright bucky (or lies supine on a stretcher/table) without leaning backward.
Central Ray Angulation: Direct the X-ray tube angled to cephalad (directed superiorly).
Bucky Alignment: Recenter the bucky/IR stand directly to the angled central ray.
Outcome: Projects the clavicles superiorly above the apical fields without requiring patient lordotic posture. This angled tube approach is the preferred alternative method when lordotic posture cannot be achieved.
Respiration and Collimation Execution:
Instruct the patient to take two deep breaths in and hold on the second full inspiration.
Apply precise collimation to the target thoracic region before making the exposure.