9/9/26

Concentration Units and Salinity Standards

  • Unit Scale Optimization:

    • Expressing extremely low chemical concentrations in standard percentage or decimal form often results in unwieldy numbers or scientific notation (e.g., 0.0055×10−30.0055 \times 10^{-3}).

    • To streamline communication and avoid cumbersome exponent expressions, unit bases are adjusted according to the concentration scale:

    • Parts per hundred (%\% or pph\text{pph})

    • Parts per thousand (ppt\text{ppt})

    • Parts per million (ppm\text{ppm})

    • Selecting the appropriate scale converts raw fractions into manageable integers or simple decimals (e.g., 5.3 ppm5.3\,\text{ppm} instead of 0.00000530.0000053).

    • Conversely, using oversized numerical values in small units (e.g., 50000 ppm50000\,\text{ppm} or 5000000 ppm5000000\,\text{ppm}) is improper; 50000 ppm50000\,\text{ppm} should be converted to 50 ppt50\,\text{ppt}, and 5000000 ppm5000000\,\text{ppm} corresponds to 500 pph500\,\text{pph} (500%500\%).

  • Water Potability Threshold:

    • Salinity measures the total concentration of dissolved salts in a water sample.

    • Water exceeding a concentration threshold of 500 ppm500\,\text{ppm} is classified as non-potable (unsafe for drinking).

Fundamentals of Separation Techniques

Separation techniques rely on differences in physical properties between components in a mixture. Four primary physical separation techniques used in water sample analysis are gravity filtration, vacuum filtration, evaporation, and decantation.

Gravity Filtration and Vacuum Filtration

  • Gravity Filtration:

    • Principle: Separates an insoluble solid from a liquid using a permeable membrane (e.g., filter paper, cloth, or sand layer) driven purely by gravitational force based on solubility differences.

    • Filter Paper Folding Procedure:

    1. Fold the circular filter paper completely in half to form a semicircle.

    2. Fold the paper in half a second time to form a quarter-circle cone shape.

    3. Tear off a small corner (small tear-off corner) from the outer folded edge.

    4. Open the cone using the un-torn side. Opening the intact side ensures a complete, leak-free conical filter cone.

    5. Adjust the cone opening diameter to fit the specific funnel size being utilized.

    • Ring Stand and Funnel Setup:

    • Mount the funnel support ring onto the vertical support rod using the threaded screw mechanism.

    • Insert the glass funnel into the ring seat at a moderate height above the receiver container.

    • Place the folded paper cone inside the funnel.

    • To secure the paper cone to the glass walls, moisten the filter paper lightly using deionized water (dH2O\text{dH}_2\text{O}) from a wash bottle, pressing the paper flush against the glass.

    • Crucial Rule for Quantifying Samples: Do not pre-moisten the filter paper with pure water if doing so dilutes the incoming liquid sample being collected for mass analysis. Instead, use a small portion of the filtered liquid sample itself to seat the paper.

    • Operation Protocol:

    • Never fill the filter paper cone to the absolute top rim with mixture; overfilling causes unfiltered liquid and suspended solids to spill over the edges into the filtrate receiver.

  • Vacuum Filtration:

    • Principle: Uses reduced pressure (vacuum suction) below the filter membrane to draw liquid through rapidly and assist in drying the collected solid residue.

    • Apparatus:

    • Heavy-walled Erlenmeyer flask with a side-arm tubulation (side-arm flask).

    • Flexible vacuum tubing connected to a vacuum source or water aspirator.

    • Water Aspirator Mechanism:

    • Turning on the water tap causes high-velocity water to flow through the aspirator, creating a localized pressure drop that continuously pulls air from the connected vacuum line.

    • Vacuum Safety Trap:

    • An intermediate trap flask is connected between the reaction/filtration flask and the vacuum pump or aspirator.

    • The trap prevents solvent or liquid backflow from entering and damaging the vacuum pump mechanism, allowing recovery of spilled liquids.

Evaporation and Decantation Methods

  • Evaporation:

    • Principle: Recovers dissolved solid solutes from a solution by vaporizing the liquid solvent through thermal energy application.

    • Process Dynamics:

    • As heat is supplied, solvent molecules gain kinetic energy and transition to the vapor state.

    • Dissolved solids do not evaporate at liquid boiling temperatures because their phase change points (melting and vaporization temperatures) are significantly higher.

    • As the solvent departs, dry solid solute remains in the vessel.

    • Equipment: Direct heating is performed using an electric hot plate rather than an open flame.

  • Decantation:

    • Principle: Separates an insoluble suspended solid from a liquid phase without using a filter membrane by utilizing gravity sedimentation.

    • Execution:

    • The mixture is allowed to stand undisturbed until dense suspended particles settle to the bottom of the beaker.

    • The upper clear liquid layer is poured off slowly and carefully.

    • A glass stirring rod is held against the spout of the pouring vessel, allowing the liquid to flow smoothly down the rod into the receiving beaker. The rod acts as a physical barrier to block loose sediment from escaping.

Experimental Procedure: Part A – Analysis of Dissolved Solids

Part A isolates and quantifies the mass of dissolved solids present in a contaminated water sample using filtration followed by evaporation.

  • Required Apparatus:

    • Glass funnel and ring stand support.

    • Filter paper cone.

    • Clean, dry evaporating dish.

    • Watch glass (cristal de reloj).

    • Electric hot plate.

    • Volumetric pipette (10 mL10\,\text{mL} capacity).

    • Crucible tongs.

    • Beakers (20 mL20\,\text{mL} to 30 mL30\,\text{mL} transfer beaker, and receiver beaker).

  • Step-by-Step Procedure:

    1. Sample Preparation & Filtration:

    • Do not place volumetric pipettes directly into the primary water stock bottle to prevent contamination.

    • Pour approximately 20 mL20\,\text{mL} to 30 mL30\,\text{mL} of the contaminated sample into a transfer beaker.

    • Allow heavy suspended solids in the transfer beaker to settle.

    • Slowly decant the upper liquid into the prepared gravity filtration cone to avoid clogging the paper pores with heavy particles.

    • Collect the clear liquid filtrate (containing only dissolved solids) in a clean, dry receiver beaker until more than 10 mL10\,\text{mL} of filtrate is gathered.

    1. Mass Measurements of Apparatus:

    • Determine and record the exact mass of a clean, dry evaporating dish (Mass1\text{Mass}_1).

    • Determine and record the mass of the clean, dry watch glass.

    1. Sample Addition:

    • Using a 10 mL10\,\text{mL} volumetric pipette, transfer exactly 10 mL10\,\text{mL} of the clear filtered liquid into the weighed evaporating dish.

    • Measure and record the combined mass of the evaporating dish and the 10 mL10\,\text{mL} filtered sample (Mass2\text{Mass}_2).

    1. Controlled Evaporation Heating:

    • Place the evaporating dish onto the hot plate.

    • Heat gradually to prevent vigorous boiling and violent thermal splashing:

      • Set hot plate power setting to level 22 for 3 minutes3\,\text{minutes}.

      • Increase setting to level 33 for 3 minutes3\,\text{minutes}.

      • Increase setting to level 44 if necessary to maintain steady vapor generation without boiling splatter.

    • As liquid volume decreases significantly, partially cover the evaporating dish with the watch glass to catch potential micro-splatters.

    • If salt spatters onto the underside of the watch glass, the watch glass mass must be accounted for or scraped back into the dish.

    1. Final Drying and Mass Determination:

    • Continue heating until all solvent water has completely evaporated and the remaining solid residue is dry.

    • Turn off the hot plate and carefully remove the hot evaporating dish using crucible tongs.

    • Allow the evaporating dish to cool at room temperature for 3 minutes3\,\text{minutes}.

    • Measure and record the final mass of the cooled evaporating dish containing dry dissolved solids (Mass4\text{Mass}_4).

Experimental Procedure: Part B – Analysis of Total Solids

Part B quantifies the total solids (both dissolved and suspended solids combined) in the water sample without performing filtration.

  • Step-by-Step Procedure:

    1. Apparatus Preparation:

    • Measure and record the mass of a second clean, dry evaporating dish (Mass1\text{Mass}_1).

    1. Agitation and Sample Transfer:

    • Vigorously shake and agitate the primary contaminated water stock bottle to ensure all settled suspended solids are evenly redistributed throughout the liquid column.

    • Transfer approximately 20 mL20\,\text{mL} of the thoroughly agitated, turbid suspension into a clean transfer beaker.

    • Using a clean 10 mL10\,\text{mL} volumetric pipette, immediately draw and transfer exactly 10 mL10\,\text{mL} of the agitated suspension into the evaporating dish.

    1. Mass Determination Prior to Heating:

    • Measure and record the combined mass of the evaporating dish and the 10 mL10\,\text{mL} unfiltered sample (Mass2\text{Mass}_2).

    1. Evaporation and Solid Isolation:

    • Place the evaporating dish on the hot plate.

    • Apply gradual heat (starting at setting 22, escalating to 33 and 44 every 3 minutes3\,\text{minutes}) until liquid begins vaporizing gently.

    • Lower heat settings near complete dryness and cover loosely with a watch glass to contain spattering.

    • Heat until the sample reaches absolute dryness.

    1. Cooling and Final Mass:

    • Using crucible tongs, move the evaporating dish off the hot plate.

    • Cool the dish for 3 minutes3\,\text{minutes}.

    • Measure and record the final mass of the evaporating dish with total dry residue (Mass4\text{Mass}_4).

Data Tabulation and Mathematical Calculations

  • Experimental Data Parameters:

    • Data Point 1: Mass of clean, dry evaporating dish (Massdish\text{Mass}_{\text{dish}}).

    • Data Point 2: Mass of evaporating dish + liquid sample (Massdish+sample\text{Mass}_{\text{dish+sample}}).

    • Data Point 4: Mass of evaporating dish + dry solid residue (Massdish+dry\text{Mass}_{\text{dish+dry}}).

  • Derived Calculated Values:

    • Sample Liquid Mass (Data Point 3):     Masssample=Data Point 2−Data Point 1\text{Mass}_{\text{sample}} = \text{Data Point 2} - \text{Data Point 1}

    • Dry Solid Mass (Data Point 5):     Massdry solid=Data Point 4−Data Point 1\text{Mass}_{\text{dry solid}} = \text{Data Point 4} - \text{Data Point 1}

    • Suspended Solids Mass:     Masssuspended solids=Massdry solid (Part B)−Massdry solid (Part A)\text{Mass}_{\text{suspended solids}} = \text{Mass}_{\text{dry solid (Part B)}} - \text{Mass}_{\text{dry solid (Part A)}}

    • Concentration in Parts Per Million (ppm\text{ppm}):     Concentration (ppm)=(Massdry solidMasssample)×106\text{Concentration (ppm)} = \left( \frac{\text{Mass}_{\text{dry solid}}}{\text{Mass}_{\text{sample}}} \right) \times 10^6

Laboratory Safety and Waste Management

  • Personal Protective Equipment (PPE):

    • Lab coats (bata) and safety goggles (gafas de seguridad) must be worn at all times prior to beginning experimental procedures.

  • Waste Handling Protocols:

    • Liquid waste solutions must be poured into the designated central liquid waste bottle equipped with a funnel.

    • Beakers containing residual solids must be rinsed using deionized water from a wash bottle, pouring all rinse washings directly into the liquid waste container.

    • Used filter papers containing trapped insoluble solids must be discarded into the designated collection tray positioned in front of the waste bottle.

    • Glassware containing stuck dried solids should be cleaned by scraping residue gently with a spatula, followed by thorough washing with deionized water.

  • Hot Plate Safety:

    • Assume hot plates remain hot even after being switched off.

    • Never handle heated evaporating dishes with bare hands; always use designated crucible tongs.

    • Allow hot plates to cool completely in place before storage.