Preliminary Steps in Radiography

Introduction to Radiography and Professional Practice

  • Definitions and Professional Roles:

    • Radiologic Technology: A healthcare profession encompassing all diagnostic imaging technologists and radiation therapists.
    • Radiographer: A radiologic technologist who administers ionizing radiation to perform radiographic procedures, producing diagnostic images at the request of a licensed medical practitioner.
    • Required Knowledge & Skills: Effective clinical practice requires combining technical skills with extensive knowledge of physics, anatomy, physiology, and pathology.
  • Radiography Practice Standards:

    • Formulated, maintained, and published by the American Society of Radiologic Technologists (ASRT).
    • Define the scope of practice for radiography, detail educational and credentialing requirements, and set clear professional benchmarks.
    • Section Components:
    • Clinical Performance Standards: Define activities regarding patient care, operational procedures, and diagnostic evaluation.
    • Quality Performance Standards: Define activities regarding equipment operation, safety, and quality assurance.
    • Professional Performance Standards: Define expectations for professional conduct, ethics, and ongoing education.
    • The current version is maintained on the ASRT website (ASRT.org).
  • Ethics in Radiologic Technology:

    • Definition: Ethics represents a health professional's moral responsibility and the science of appropriate conduct toward patients and healthcare team members.
    • ARRT Standards of Ethics: Developed and maintained by the American Registry of Radiologic Technologists (ARRT) to translate professional values into concrete practice.
    • Code of Ethics: Composed of 10 statements serving as an aspirational guide for professional behavior.
    • Rules of Ethics: Composed of 22 mandatory, enforceable rules defining minimally acceptable professional conduct.
    • CAMRT Code of Ethics: Developed by the Canadian Association of Medical Radiation Technologists (CAMRT) to delineate ethical expectations for practitioners in Canada (CAMRT.ca).
  • Advanced Clinical Practice:

    • Advanced practice roles enable experienced radiographers to act as a "radiologist extender" to perform or assist with:
    • Patient care activities.
    • Selected radiologic procedures.
    • Initial image observations.
    • Professional Titles:
    • Radiologist Assistant (RA)
    • Radiology Practitioner Assistant (RPA)
    • Credentialing Requirements: Achieving RA or RPA status requires ARRT radiography certification, completion of advanced formal education, and supervised clinical experience under a radiologist preceptor, followed by passing an advanced-level certification examination.

Room Preparation and Infection Control

  • Care of the Examination Room:

    • Radiographer Responsibility: Maintaining strict cleanliness of the examination room and equipment (X-ray tube housing, tabletop, and accessories) to minimize pathogen transmission and promote patient confidence.
    • Room Preparation Protocols:
    • Disinfect all contact surfaces prior to patient arrival.
    • Ensure the room is clean, organized, and stocked with necessary positioning aids.
    • Place a fresh pillowcase on positioning pillows.
  • Control of Pathogen Contamination:

    • The Centers for Disease Control and Prevention (CDC) provides guidelines for infection control, with Standard Precautions for All Patient Care serving as the foundation.
    • Core Standard Precautions:
    • Hand Hygiene: Perform hand hygiene before and after each patient interaction.
    • Personal Protective Equipment (PPE): Use PPE (gloves, gowns, masks, eye protection) whenever exposure to infectious material is anticipated.
    • Respiratory Hygiene / Cough Etiquette: Implement measures to contain respiratory secretions.
    • Patient Placement: Ensure appropriate isolation or bed assignment based on infection transmission risks.
    • Equipment Disinfection: Properly clean and disinfect patient-care instruments, equipment, and environmental surfaces.
    • Textiles & Laundry: Handle contaminated linens carefully to prevent pathogen dispersion.
    • Safe Injection Practices: Follow strict aseptic technique; wear a surgical mask during lumbar punctures.
    • Sharps Safety: Ensure safe handling and disposal of needles and sharp devices.
    • Transmission-Based Precautions: Applied in addition to Standard Precautions for patients with known or suspected airborne, droplet, or contact transmissible infections.
  • Handwashing Practices:

    • Handwashing is the single easiest and most convenient method to prevent the spread of microorganisms.
    • Mandatory Handwashing Indications:
    • Before and after caring for every individual patient.
    • After examining patients with known communicable diseases.
    • After coming into contact with blood, bodily fluids, secretions, or excretions.
    • Prior to starting any invasive procedure.
    • Prior to touching high-risk, immunocompromised, or vulnerable patients.

Handwashing and Equipment Cleaning Procedure

Patient Care, Communication, and Motion Management

  • Basic Patient Care & Communication:
    • Patient Explanation: Technologists must provide coherent patients with a clear explanation of the procedure, detailing what to expect, potential discomfort, and instructions to ensure comfort and compliance.
    • Clinical History Collection:
    • Verifying the correct exam was ordered against clinical indications.
    • Observing physical conditions or anatomical abnormalities to relay to the radiologist.

Patient Interaction and History Taking

  • Types and Control of Motion:
    • Uncontrolled motion during exposure severely degrades recorded image detail and spatial resolution.

Motion Artifact Example

  • Involuntary Motion:
    • Causes: Heartbeat, chills, peristalsis, muscle tremors, spasms, and severe pain.
    • Primary Control Mechanism: Utilizing the shortest possible exposure time (seconds\text{seconds}).
  • Voluntary Motion:
    • Causes: Nervousness, discomfort, excitability, mental illness, fear, age (pediatric or geriatric), and uncontrolled breathing.
    • Control Mechanisms: Giving clear instructions, providing patient comfort, adjusting positioning support devices, and applying physical immobilization.
    • Uncooperative Patients: For patients unable to cooperate (e.g., young children, confused elderly, or patients with severe mental illness), decreasing exposure time is the primary method of motion control.
  • Equipment Motion: Unintended movement originating from the X-ray tube mount, table, or cassette tray.

Positioning Sponges and Immobilization Devices

Image Receptors and Accessory Equipment

  • Image Receptor (IR) Definition & Types:
    • An Image Receptor is defined as a device that receives the energy of the remnant X-ray beam and forms the diagnostic image of the body part.
    • Four Primary Types:
    1. Solid-State Digital Detectors: Flat-panel digital radiography (DR) detectors utilizing amorphous silicon or amorphous selenium, available as fixed tabletop/bucky units, tethered panels, or wireless plates.
    2. Photostimulable Storage Phosphor Image Plate (PSP IP): Computed Radiography (CR) plates coated with photostimulable phosphor that store latent image energy until read by a laser scanner inside a CR reader.
    3. Fluoroscopic Image Receptor: Real-time imaging systems using either an image intensifier tube coupled to a television camera/monitor or a flat-panel digital fluoroscopy detector.
    4. Cassette with Film: Traditional screen-film cassettes requiring chemical film processing.

Solid-State Digital Detector Processing Unit

Wireless DR Image Receptor

Photostimulable Phosphor Cassette

Fluoroscopic Image Intensifier Unit

  • Accessory Equipment:
    • Positioning Aids: Radiolucent sponges, sandbags, and specialized leg holders (e.g., Ferlic leg holder) used to stabilize the body part.
    • Grids: Precision devices composed of lead strips placed between the patient and the IR to absorb scattered radiation, enhancing contrast.
    • Compensating Filters: Absorptive devices placed in the X-ray beam path to compensate for variations in tissue thickness and density, yielding uniform image brightness.

Radiographic Technical Factors and Exposure Technique Charts

  • Prime Technical Factors:

    • Milliamperage (mA): Controls X-ray photon quantity and rate of exposure.
    • Kilovolt Peak (kVp): Controls X-ray beam energy, quality, and penetrability.
    • Exposure Time (seconds): Duration of beam activation; multiplied by mA to determine total milliampere-seconds (mAs\text{mAs}).
    • Control Systems: Manual technical factor selection or Automatic Exposure Control (AEC) chambers.
  • Technique Charts:

    • Standardized charts must be available in every examination room and attached to all mobile units.
    • Foundation Parameters Required for Technique Chart Establishment:
    • Milliampere-seconds (mAs\text{mAs})
    • Kilovolt peak (kVp\text{kVp})
    • Automatic Exposure Control (AEC\text{AEC}) chamber selection and sensitivity
    • Source-to-Image Receptor Distance (SID\text{SID})
    • Relative patient or part thickness (cm\text{cm})
    • Grid selection and ratio
    • CR/DR exposure indicators
    • IR or collimated field dimensions
    • Electrical supply characteristics (generator phase and frequency)

Sample Radiographic Exposure Technique Chart

  • Essential Projections Technical Reference Data (Thoracic Viscera):
    • Chest: Lungs and Heart — PA Projection: Part thickness: 22 cm22\,\text{cm}; 120 kVp120\,\text{kVp}; 72′′ SID72''\,\text{SID}; Collimation: 14′′×16′′14'' \times 16'' (35×40 cm35 \times 40\,\text{cm}); CR: 2.8 mAs2.8\,\text{mAs}, Dose: 0.188 mGy0.188\,\text{mGy}; DR: 1.4 mAs1.4\,\text{mAs}, Dose: 0.089 mGy0.089\,\text{mGy}.
    • Chest: Lungs and Heart — Lateral Projection: Part thickness: 33 cm33\,\text{cm}; 120 kVp120\,\text{kVp}; 72′′ SID72''\,\text{SID}; Collimation: 14′′×17′′14'' \times 17'' (35×43 cm35 \times 43\,\text{cm}); CR: 7.1 mAs7.1\,\text{mAs}, Dose: 0.550 mGy0.550\,\text{mGy}; DR: 3.6 mAs3.6\,\text{mAs}, Dose: 0.273 mGy0.273\,\text{mGy}.
    • Chest: Lungs and Heart — PA Oblique Projection: Part thickness: 25 cm25\,\text{cm}; 120 kVp120\,\text{kVp}; 72′′ SID72''\,\text{SID}; Collimation: 14′′×17′′14'' \times 17'' (35×43 cm35 \times 43\,\text{cm}); CR: 3.6 mAs3.6\,\text{mAs}, Dose: 0.255 mGy0.255\,\text{mGy}; DR: 1.8 mAs1.8\,\text{mAs}, Dose: 0.124 mGy0.124\,\text{mGy}.
    • Chest: Lungs and Heart — AP Projection (Nongrid, 40'' SID): Part thickness: 22 cm22\,\text{cm}; 90 kVp90\,\text{kVp}; 40′′ SID40''\,\text{SID}; Collimation: 16′′×14′′16'' \times 14'' (40×35 cm40 \times 35\,\text{cm}); CR: 4.0 mAs4.0\,\text{mAs}, Dose: 0.655 mGy0.655\,\text{mGy}.
    • Chest: Lungs and Heart — AP Projection (DR Nongrid, 40'' SID): Part thickness: 22 cm22\,\text{cm}; 105 kVp105\,\text{kVp}; 40′′ SID40''\,\text{SID}; Collimation: 16′′×14′′16'' \times 14'' (40×35 cm40 \times 35\,\text{cm}); DR: 1.6 mAs1.6\,\text{mAs}, Dose: 0.340 mGy0.340\,\text{mGy}.
    • Chest: Lungs and Heart — AP Projection (Bucky/Grid, 72'' SID): Part thickness: 22 cm22\,\text{cm}; 120 kVp120\,\text{kVp}; 72′′ SID72''\,\text{SID}; Collimation: 14′′×16′′14'' \times 16'' (35×40 cm35 \times 40\,\text{cm}); CR: 3.2 mAs3.2\,\text{mAs}, Dose: 0.217 mGy0.217\,\text{mGy}; DR: 1.6 mAs1.6\,\text{mAs}, Dose: 0.104 mGy0.104\,\text{mGy}.
    • Pulmonary Apices — AP Axial Projection: Part thickness: 23 cm23\,\text{cm}; 120 kVp120\,\text{kVp}; 72′′ SID72''\,\text{SID}; Collimation: 14′′×11′′14'' \times 11'' (35×28 cm35 \times 28\,\text{cm}); CR: 4.0 mAs4.0\,\text{mAs}, Dose: 0.198 mGy0.198\,\text{mGy}; DR: 2.0 mAs2.0\,\text{mAs}, Dose: 0.097 mGy0.097\,\text{mGy}.
    • Lungs and Pleurae — Lateral Decubitus Projection: Part thickness: 22 cm22\,\text{cm}; 120 kVp120\,\text{kVp}; 72′′ SID72''\,\text{SID}; Collimation: 17′′×14′′17'' \times 14'' (43×35 cm43 \times 35\,\text{cm}); CR: 4.0 mAs4.0\,\text{mAs}, Dose: 0.271 mGy0.271\,\text{mGy}; DR: 2.0 mAs2.0\,\text{mAs}, Dose: 0.133 mGy0.133\,\text{mGy}.
    • Lungs and Pleurae — Dorsal / Ventral Decubitus Projection: Part thickness: 33 cm33\,\text{cm}; 120 kVp120\,\text{kVp}; 72′′ SID72''\,\text{SID}; Collimation: 17′′×14′′17'' \times 14'' (43×35 cm43 \times 35\,\text{cm}); CR: 9.0 mAs9.0\,\text{mAs}, Dose: 0.697 mGy0.697\,\text{mGy}; DR: 4.5 mAs4.5\,\text{mAs}, Dose: 0.344 mGy0.344\,\text{mGy}.

Radiation Protection, Geometry, and Beam Alignment

  • Gonad Shielding Guidelines:
    • AAPM position statements, endorsed by the ACR and other professional bodies, indicate routine gonadal shielding can negatively impact examination efficacy (e.g., obscuring anatomy or interfering with AEC).
    • State regulations may still mandate gonadal shielding; technologists must remain aware of institutional and regulatory guidelines.

Gonad Shielding Application Examples

  • Image Receptor Placement Configurations:
    • Lengthwise Position: Long axis of the IR aligned parallel with the long axis of the body (most commonly used, e.g., AP Abdomen).
    • Crosswise Position: Long axis of the IR aligned perpendicular to the long axis of the body (e.g., AP Pelvis).
    • Diagonal Position: IR rotated diagonally to cover long bones (e.g., AP Leg including knee and ankle joints).
    • Built-in Flat-Panel Detectors: Typically 17×17 inches17 \times 17\,\text{inches} (43×43 cm43 \times 43\,\text{cm}), movable lengthwise along the bucky track.

Image Receptor Positioning Options

  • Central Ray (CR) Alignment:

    • The central or principal photon beam is termed the Central Ray (CR).
    • The CR is centered to the anatomy of interest and the IR.
    • Standard goal: CR perpendicular to the part and IR to prevent distortion.
    • Reasons for Angling the CR:
    • Avoid superimposition of structures.
    • "Straighten out" curved structures.
    • Align the beam through an angled joint space.
    • Avoid distortion of an angled structure.
  • Source-to-Image Receptor Distance (SID):

    • Distance from the anode focal spot inside the X-ray tube to the IR surface.
    • Key factor affecting magnification, spatial resolution, and patient dose.
    • Standard Operating SIDs:
    • 40 inches40\,\text{inches} (102 cm102\,\text{cm}): Traditional standard for general examinations.
    • 48 inches48\,\text{inches} (122 cm122\,\text{cm}): Modern standard adopted across many facilities to reduce magnification.
    • 72 inches72\,\text{inches} (183 cm183\,\text{cm}): Standard for chest and cervical spine imaging to minimize Object-to-Image Receptor Distance (OID) magnification.
    • Specialized projections in Merrill's Atlas range from 30 inches30\,\text{inches} (76 cm76\,\text{cm}) to 120 inches120\,\text{inches} (305 cm305\,\text{cm}); a minimum of 40 inches40\,\text{inches} (102 cm102\,\text{cm}) is recommended if unspecified.
  • Source-to-Skin Distance (SSD):

    • Distance from the X-ray tube focal spot to the patient's skin surface.
    • Influences patient entrance exposure dose.
    • NCRP Guidelines: SSD shall not be less than 12 inches12\,\text{inches} (<30 cm<30\,\text{cm}) and should not be less than 15 inches15\,\text{inches} (<38 cm<38\,\text{cm}).

SID and SSD Distance Diagram

  • Collimation and Shuttering Rules:
    • Restricting the radiation field size to include only the anatomy of interest.
    • Two Primary Purposes:
    1. Minimizes patient radiation dose.
    2. Reduces scatter radiation, improving contrast resolution.
    • Ethical Mandate: Collimating larger than the required field size violates the ARRT Code of Ethics and ASRT Practice Standards.

Collimation Light Field Alignment

  • Shuttering (Electronic Cropping):
    • Software process adding a dark border around a collimated field in DR systems for viewing aesthetics.
    • Prohibition against Misuse: Electronic shuttering must never be used to replace physical beam collimation. Post-exposure cropping increases patient dose and creates legal liability if cropped diagnostic information leads to a missed diagnosis.

Anatomic Markers, Image Display, and Evaluation

  • Anatomic Side Markers:

    • Medicolegal requirements mandate physical lead Right (R\text{R}) or Left (L\text{L}) markers on all radiographs prior to exposure.
    • Rules for Marker Placement:
    • Must be visible on the image without obscuring anatomy.
    • Placed within the collimation field border.
    • Positioned outside of lead shielding.
    • Post-acquisition digital annotation is discouraged due to the risk of lateral site identification errors.
  • Image Display Standards:

    • Radiographs are viewed in standard anatomic position.

Anatomic Position Reference

  • Standard Display Exceptions: Images of extremities—specifically hands, fingers, wrists, feet, and toes—are displayed as seen from the perspective of the X-ray tube, with digits pointing upward toward the ceiling.

Hand Radiograph Display Orientation

  • Required Image Identification:
    1. Date of examination.
    2. Patient name or identification number.
    3. Anatomic side marker (R\text{R} or L\text{L}).
    4. Healthcare institution name.

Radiographic Identification and Marker Example

  • Image Evaluation Criteria:
    • Technologists must evaluate every image for acceptability, safety compliance, and procedural goals.
    • Criteria include verifying patient ID, marker placement, collimation, shielding, and absence of technical artifacts.

Radiographic Considerations for Obese Patients

  • Obesity Demographics and Definitions:

    • Obesity prevalence has doubled in the last 15 years; 71%71\% of American adults are overweight, obese, or morbidly obese.
    • Body Mass Index (BMI) Classifications:
    • Obese: BMI=30 to 39.9\text{BMI} = 30 \text{ to } 39.9
    • Morbidly Obese: BMI≥40\text{BMI} \ge 40
    • Body weight and diameter determine whether radiographic procedures can be performed.
  • Equipment Considerations:

    • Weight limits on radiographic tables; older tables held 350 to 450 lbs350 \text{ to } 450\,\text{lbs}, while redesigned modern tables support up to 700 lbs700\,\text{lbs}.
    • Diameter limits on fluoroscopy towers, CT scanners, and MRI units.
    • Mobile DR detectors facilitate positioning by providing greater tube-to-table clearance.
  • Patient Transfer and Positioning:

    • Utilization of larger wheelchairs, heavy-duty stretchers, team movement, proper body mechanics, transfer boards, air mattresses, and ceiling-mounted power lifts.

Ceiling Mounted Patient Hoist System

Inflatable Air Transfer Mattress System

  • Communication Guidelines:

    • Use empathetic communication, avoid mentioning weight, and clearly explain movement and positioning steps.
  • Landmark Location in Morbidly Obese Patients:

    • Most surface bony landmarks are unpalpable due to adipose tissue.
    • Jugular Notch Landmark Method: Locate the palpable jugular notch and measure inferiorly along the midline to locate the pubic symphysis plane based on height:
    • Height under 5 feet5\,\text{feet} (<152 cm<152\,\text{cm}): Pubic symphysis is 21 inches21\,\text{inches} (53 cm53\,\text{cm}) inferior to jugular notch.
    • Height 5 to 6 feet5 \text{ to } 6\,\text{feet} (152 to 183 cm152 \text{ to } 183\,\text{cm}): Pubic symphysis is 22 inches22\,\text{inches} (56 cm56\,\text{cm}) inferior to jugular notch.
    • Height over 6 feet6\,\text{feet} (>183 cm>183\,\text{cm}): Pubic symphysis is 24 inches24\,\text{inches} (61 cm61\,\text{cm}) inferior to jugular notch.

Jugular Notch to Pubic Symphysis Measurement

Questions & Discussion

  • Question 1: What is the easiest method to control the spread of pathogens?

    • Options: A. Use of mask on patients | B. Radiographers wearing masks | C. Wearing gloves for all procedures | D. Hand hygiene
    • Answer: D. Hand hygiene
    • Explanation: Hand hygiene is the simplest and most effective method to prevent cross-contamination and pathogen transmission in medical environments.
  • Question 2: All of the following are examples of involuntary motion, except:

    • Options: A. Peristalsis | B. Heartbeat | C. Breathing | D. Chills
    • Answer: C. Breathing
    • Explanation: Respiration is under voluntary patient control and can be stopped with clear breathing instructions. Peristalsis, heartbeat, and chills are involuntary movements.
  • Question 3: How do radiographers help reduce the risk of imaging involuntary motion?

    • Options: A. Use immobilization | B. Appropriate patient instructions | C. Clear communications | D. Use the shortest possible exposure time
    • Answer: D. Use the shortest possible exposure time
    • Explanation: Involuntary motion cannot be controlled by verbal instructions or immobilization. Decreasing exposure time to the minimum achievable duration is required.
  • Question 4: All of the following are required identification on a radiographic image, except the:

    • Options: A. Side marker | B. Patient name or ID number | C. Referring physician's name | D. Name of the facility
    • Answer: C. Referring physician's name
    • Explanation: Standard legal image identification requires examination date, patient name/ID number, side marker (R\text{R} or L\text{L}), and institution name. The referring physician's name is not required on the image.
  • Question 5: A technique chart must include all of the following, except:

    • Options: A. Pathology type | B. kVp\text{kVp} | C. AEC\text{AEC} | D. Grid
    • Answer: A. Pathology type
    • Explanation: Exposure technique charts detail technical factors (kVp\text{kVp}, mAs\text{mAs}, AEC\text{AEC}, grid, SID\text{SID}) for specific anatomical projections, not pathology classifications.
  • Question 6: Which of the following will affect whether a radiographic examination can be performed on an obese patient?

    • Options: A. Height | B. Weight | C. BMI | D. Communication skills
    • Answer: B. Weight
    • Explanation: Patient weight and body diameter directly determine equipment compatibility due to table load limits and gantry/aperture clearance dimensions.
  • Question 7: Which guideline is used to locate the pubic symphysis on an obese patient who is approximately 5 feet,5 inches5\,\text{feet}, 5\,\text{inches} tall?

    • Options: A. 15 inches15\,\text{inches} from the jugular notch | B. 21 inches21\,\text{inches} from the jugular notch | C. 22 inches22\,\text{inches} from the jugular notch | D. 24 inches24\,\text{inches} from the jugular notch
    • Answer: C. 22 inches22\,\text{inches} from the jugular notch
    • Explanation: For patients between 5 feet5\,\text{feet} and 6 feet6\,\text{feet} tall, the pubic symphysis plane lies 22 inches22\,\text{inches} inferior to the jugular notch.