Specialized Combat Explosive Firing Guide (TEC-S)
Overview and Employment Domains of Explosive Firing
Regulatory Framework and Scope:
- The operational implementation of explosives in the French Army is governed by official doctrine and technical manuals under two distinct domains: Interarms Combat Explosive Firing (Tir Explosif de Combat Interarmes - TEC-IA) and Specialized Combat Explosive Firing (Tir Explosif de Combat Spécialisé - TEC-S).
- Manual PFT GEN 3.12.14 establishes regulations, procedures, and safety rules for specialized explosive firing, including elementary destructions, tactical explosive breaching (effraction chaude), and specialized equipment demolition.
- The manual applies primarily to Engineer units (Arme du génie), Land Special Forces (Forces Spéciales Terre - FST), and Explosive Ordnance Disposal (EOD) personnel.
Comparison of Employment Domains:
- TEC-IA Domain (PFT GEN 3.12.12):
- Covers basic explosive employment for non-engineer, conventional combined-arms units.
- Aimed at destroying dangerous unexploded ordnance pursuant to PIA 207 (MESSEC) and performing simple surface destructions.
- TEC-S Domain (PFT GEN 3.12.14 and PFT GEN 3.12.15):
- Modernizes advanced explosive techniques for high-intensity warfare environments.
- Integrates physiological constraints from detonation blast waves, mechanical shock effects, tactical combined-arms tempo, and structural architecture of target infrastructures.
- Introduces reduced safety distances for tactical explosive breaching (effraction chaude) by optimizing charge sizing and leveraging structural barriers and corner attenuation.
Domain Compatibility and Interoperability:
- Personnel authorized under TEC-S are fully qualified to lead or assist in TEC-IA activities, provided they comply with PFT GEN 3.12.12 regulations.
- Personnel participating in a TEC-S exercise must be explicitly qualified and authorized under the TEC-S domain.
General Properties and Physics of Explosives
Fundamental Definition:
- An explosive is a chemical substance or mixture which, under appropriate initiation, undergoes an extremely rapid chemical decomposition reaction in detonation mode, generating high-temperature gases under immense pressure.
- Primary useful effects sought in military demolitions:
- Overpressure / Shockwave Effect: Characterized by brisance (), creating cracks and fractures through contact.
- Projection / Expansion Effect: Driven by high-temperature gas expansion, providing a progressive or sudden pushing and ejection force on fragmented material.
Types of Chemical Reactions:
- Combustion:
- Propagates via thermal conductivity at a moderate speed (order of centimeters per second).
- Material burns without explosive shock.
- Deflagration:
- Accelerated combustion caused by rapid pressure and temperature rise (order of hectometers per second).
- Produces an explosive reaction with a progressive pushing force.
- Detonation:
- Chemical decomposition coupled with a supersonic shockwave (order of kilometers per second).
- Produces maximum brisance and brutal mechanical shock.
Classification of Explosives:

By Sensitivity and Employment:
- Primary Explosives (Explosifs Primaires): Extremely sensitive to flame, friction, spark, or impact (e.g., lead azide, lead styphnate). Used exclusively in small quantities inside detonators to initiate secondary explosives.
- Secondary Explosives (Explosifs Secondaires): Relatively insensitive to thermal or mechanical shock; require initiation by the shockwave of a primary explosive or booster charge (e.g., PETN, RDX, Hexolite, Tetryl). Used as main demolition charges.
By Mechanical Effect (Brisance):
Brisant Explosives: High detonation velocity (). Capable of shearing steel and solid targets via surface contact without requiring confinement or tamping (bourrage).
Less Brisant Explosives: Lower detonation velocity (). Generate larger gas volumes; require physical confinement (bourrage) to exert a prolonged pushing force (e.g., quarrying explosives).
Key Physical Characteristics:
Sensitivity: Measured by the minimum energy input required to trigger detonation via initiation, friction, shock, heat/flame, or influence (sympathetic detonation from nearby explosions).
Stability: Ability to maintain physical and chemical properties over time under environmental stress (heat, cold, humidity, storage duration). Instability causes exudation, discoloration, or crystallization, altering sensitivity dangerously.
Useful Effect / Power: Quantified relative to TNT equivalent ().
- Detonation Effects and Hazards:
Shockwave / Overpressure: Supersonic pressure pulse causing primary blast injuries and material shattering.
Blast Wind / Push Effect: Rapid expansion and subsequent contraction of heated gases, throwing objects and personnel.
Thermal Effects: Extreme gas temperatures causing burns and secondary fires.
Projections and Fragments: Primary fragments (target/casing material at initial speeds ) and secondary projectiles (ground debris/dirt at speeds up to ).
Toxic Smoke and Gases: Carbon monoxide, nitrogen oxides, and oxygen depletion in confined spaces.
Ground Vibrations: Seismic transmission causing structural collapse at distance.
Indirect Effects: Secondary structural collapse, falling debris (tiles, chimneys), and glass shattering.
- Human Blast Pathology Categorization:
Primary Blast: Internal organ damage caused directly by the supersonic overpressure wave interacting with tissue interfaces (air-tissue boundaries like ear tympanums and lungs).
Secondary Blast: Penetrating or non-penetrating trauma caused by flying fragments and debris.
Tertiary Blast: Physical displacement and impact of the body thrown against environmental structures by blast wind.
Quaternary Blast: Burns, toxic gas inhalation/asphyxiation, and crush injuries from indirect structural collapse.
Architecture and Classification of Demolition Systems
- System Components:

Moyen de mise à feu (Firing Source): Generates initial activation energy (pyrotechnic friction igniter, electric exploder, or manual shock tube igniter).
Moyen de transmission (Transmission Line): Conveys energy to the priming point (safety fuse MLEN, electric lead wire KL5, or shock tube TOC).
Moyen(s) d'amorçage (Priming Means): Detonators and intermediate boosters that generate and distribute the detonation shockwave.
Charge(s) de destruction (Demolition Charge): Main explosive blocks (PETD, PEM) or shaped charges placed on the target.
- Demolition System Configurations:
Dispositif de destruction élémentaire simplifié: A single explosive charge where the firing charge and demolition charge are unified.
Dispositif de destruction élémentaire: A firing charge initiating a single separate demolition charge.
Dispositif de destruction simple: Uses a main detonating cord line (cordeau maître) paired with branch lines (cordeaux dérivés) arranged centrally or laterally to initiate multiple separated charges.

- Dispositif de destruction multiple: A single booster block or high-capacity detonator simultaneously initiating up to 6 separate branch detonating cords.
- Dispositif de destruction "Flash": Multiple separated demolition charges initiated simultaneously using individual electric detonators wired in series or parallel without detonating cords.
- Dispositif de destruction circulaire: Closed loop main detonating cord circuit featuring dual transmission and duplicated branch cords to guarantee detonation transmission across complex targets.

- Dual Priming and Firing (Double Amorçage / Double Mise à Feu):
- Designed to eliminate misfire risks on critical targets by redundantly duplicating firing means, transmission lines, and detonators.
- Double Amorçage: Placing 2 distinct detonators on 2 taped explosive blocks or a single plastic charge (can be dual pyrotechnic, dual electric, dual shock tube, or mixed pyrotechnic/electric).
- In mixed pyrotechnic/electric dual priming, pyrotechnic ignition is executed prior to electric firing.
Firing Systems and Components
Pyrotechnic Initiation Line:
- Allumeur de Mèche Lente Modèle F1 (AL MLEN F1):
- Mass: ; Storage Hazard Class: 1.4S.
- Contains friction composition and pull-rod system. Features plastic body, safety pin, thread ring, and cap.
- Mèche Lente Modèle F2 (MLEN F2):
- Black powder core () enclosed in paper, jute, cotton, and brown polyethylene outer sheath.
- Diameter: ; Roll Mass: ( roll); Storage Class: 1.4S.
- Burning Rate: .
- Mandatory pre-use checks: Inspect for cracks/moisture, refresh tip (cut ), and calibrate ( timed burn test per new roll/climate shift). Minimum allowable operational length = .
- Détonateur Pyrotechnique BRISKA Modèle 61:
- Aluminum tube () containing lead azide/styphnate (primary) and tetryl or PETN (secondary). Storage Class: 1.4B.
- Crimp onto MLEN F2 using specialized non-sparking crimping pliers.
Electric Initiation Line:
- Exploseur Électronique ITS 100:
- Dual-housing unit: Electronic unit () + removable power source/security key (, 4 lithium batteries, capacity up to 500 firings).
- Operating Temperature: ; Maximum line impedance: .
- Features line test buttons (), charge indicator light, and dual firing buttons.
- Câble Électrique KL5:
- Dual twisted conductors (each made of 4 copper and 3 steel strands); tensile strength ; length on DR8 reel.
- Must be retired/replaced if containing more than 20 splices (épissures) overall or on the first section.
- Détonateur Électrique Instantané Modèle F3 (DETO EL I F3):
- Brass tube containing lead azide + PETN. Fitted with insulated leads, short-circuit cap, and OTAN thread plug. Storage Class: 1.4B.
- Temperature range: .
- Electromagnetic Field Safety Distances (F3 Detonator):
- Cell phones, Wi-Fi, and Bluetooth devices must be powered off or isolated.
- Electric firing suspended during thunderstorms.
- High-Voltage Power Lines: Minimum distance ; Electric Railway Lines: Minimum distance .
- Non-dotation Radio Transmitters:
- :
- :
- :
- :
- :
- :
- :
- :
- Military Transmitters (RFM7800M, BP450 jammer): Minimum distance .
Shock Tube Initiation Line (MAFTOC):
- System MAFTOC (Mise à Feu par Transmission d'Onde de Choc) is a sealed all-in-one unit comprising a manual striker igniter, shock tube (TOC, propagation velocity ), and a high-strength detonator.
- MAFTOC Courte: TOC ( active material = TNT eq).
- MAFTOC Longue: TOC ( active material = TNT eq).
- Includes a multi-line connector block capable of initiating up to 6 secondary TOC lines simultaneously.
Common Priming Components and Boosters:
- Cordeau Détonant Type Génie (CD):
- Flexible green waterproof sheath containing PETN core ( active material = TNT eq); outer diameter ; total weight ; spool; storage class 1.1D; detonation velocity .
- Joining techniques: Square knot (nœud droit) or taped splice ( length).
- Branch line knotting: Lark's head knot (nœud tête d'alouette) maintaining an acute angle () oriented in the direction of shockwave propagation.

- Raccord Mixte Indétectable Modèle 1952 (RAC MIX ID 52):
- Dual plastic threaded adapter ( and threads) with rubber compression sleeve to lock safety fuses or detonating cords into standard charge wells.
- Relais d'Amorçage pour Cordeau Modèle F1 (REL AM CORD F1):
- Mass ( PETN core = TNT eq). Features thread and hinged locking clip for CD attachment.
- Pétard de 250 g Indétectable Modèle 1951 (PETD 250g ID 51):
- Green plastic block (); total mass ; main charge Hexolite 60/40 + two PETN booster wells ( TNT eq, TNT coefficient = ). Storage class 1.1D.
- Pain Explosif Malléable HEXOMAX (PEM):
- Flexible plastic explosive block (); total/active mass ( TNT eq, TNT coefficient = ). Contains RDX + binder + 1% DMDNB chemical marker. Storage class 1.1D. Minimum kneaded thickness = .
Demolition Priming Procedures and Connections
Priming Demolition Blocks (Pétards):
- With Pyrotechnic Detonator: Insert crimped detonator into block well; secure using RAC MIX ID 1952 or electrical tape.
- With Electric Detonator: Screw threaded F3 detonator directly into the OTAN well.
- With Detonating Cord (CD):
- Via RAC MIX ID 1952: Pass CD strand through fitting into well and tighten sleeve.
- Via 4-Strand Flat Wrap (Lovage à plat 4 brins): Wrap 4 parallel strands of CD longitudinally along block face and tape securely at both ends.
- Via 5-Strand Flat Wrap (Lovage à plat 5 brins): Wrap 5 parallel strands across block face; used for circular loops and dual initiation.
- Via 4-Turn Knot (Nœud 4 tours): Form a loop along block face, wrap 4 tight turns around block end, and pass CD end through loop.
Priming Plastic Explosive (PEM HEXOMAX):
- With Detonator: Use non-sparking wooden/plastic probe to cavity an opening slightly larger than detonator; insert detonator at least deep; hand-compress plastic around detonator.
- With Detonating Cord: Tie a knotted loop (boucle nouée) on the CD strand; open the PEM block, embed the knotted loop completely inside the plastic mass, and hand-compress firmly.
Priming Detonating Cords:
- Single Strand with Detonator: Fold CD end into a loop (ganse); tape detonator flush against both parallel strands along its entire length.
- Multiple Strands (up to 6) with Detonator: Bundle up to 6 CD strands around detonator shell; tape continuously.
- Multiple Strands with PEM: Tie a joint knotted loop (boucle nouée) combining all CD strand ends and knead into PEM mass.
Qualifications, Habilitations, and Roles
- Qualifications and Habilitation Architecture:

Qualification: Technical competency awarded upon completing official training courses (I TEC-S, M TEC-S, CATi TEC-S).
Habilitation: Annual administrative authority granted by the Administrative Unit Commander (Commandant de la Formation Administrative - CFA) empowering qualified personnel to fill specific operational roles.
- Role Descriptions:
Instructeur de Tir Explosif de Combat Spécialisé (I TEC-S):
- Regiment-level explosive expert and advisor to the CFA.
- Directs M TEC-S and M TEC-IA training courses; controls annual habilitation renewals; manages unit RETEX.
Moniteur de Tir Explosif de Combat Spécialisé (M TEC-S):
- Qualified to conduct instruction, supervise explosive preparations, and lead firing ateliers (AMO).
Directeur de Tir Explosif de Combat Spécialisé (D TEC-S):
- Officer or senior NCO (CDS / SOA) holding I TEC-S or M TEC-S, habilitated by CFA.
- Holds absolute safety and operational authority over the firing range and implementation zone (ZMO).
- Retains sole authority to order weapon firing (Mise à feu).
Chef de Groupe de Tir Explosif de Combat Spécialisé (CDG TEC-S):
- NCO or team leader holding M TEC-S, habilitated by CFA.
- Commands an Atelier de Mise en Œuvre (AMO); supervises placement, priming, and firing of charges under D TEC-S control.
Officier de Sécurité (OS):
- Safety officer appointed to assist D TEC-S in monitoring a Sector (SMO) or Atelier (AMO).
Chef de la Troupe (CDT):
- Tactical commander of combined-arms maneuver element (Platoon level). Subordinate to D TEC-S for range safety.
Cadre Chargé des Munitions:
NCO (M TEC-S / CDG TEC-S) responsible for explosive drawdown, depot management, safety fuse calibration, inventory accounting, and maintaining an emergency destruction lot (lot de destruction) on site.
Recurrent Training Requirements:
Minimum firing activity: Participated in at least 1 real explosive firing exercise in the preceding 3 years.
Annual maintenance: Annual safety refresh lecture by I TEC-S + participation/supervision of at least 1 real or inert explosive session.
Range Safety, Areas, and Environmental Layout
Range Infrastructure Categories:
- Without Permanent Shelter: Maximum allowable charge = TNT equivalent (timber and masonry targets only).
- With Permanent Shelter: Max charge up to TNT equivalent.
- Specific Breaching Screen (Écran d'effraction):
- Minimum height = ; Thickness = (reinforced concrete) or (sandbags/earth merlon); Length = extends at least beyond personnel position.
Zoning Definitions:
- Zone de Mise en Œuvre (ZMO): Overall authorized firing range area.
- Secteur de Mise en Œuvre (SMO): Subdivision of ZMO for up to 1 platoon element (Max 3 SMO per ZMO).
- Atelier de Mise en Œuvre (AMO): Demolition work site commanded by 1 CDG TEC-S (Max 3 AMO per SMO; Max 2 AMO in tactical firing exercises).

Zone de Choc (ZC): Circular shockwave hazard area around target where personnel, even if shielded, are exposed to primary blast overpressure.
Zone Dangereuse (ZD): Circular hazard area around target where unshielded personnel are exposed to secondary fragments and projectiles.
- Safety Zones and Ear Protection Regulations:
Hearing protection is mandatory for all personnel inside ZD.
Maximum exposure limit: Personnel located within are limited to a maximum of 5 explosive firings per 24-hour cycle.
Unshielded Primary Blast Shockwave Radius ():
| Charge Mass ( TNT eq) | Attenuation (Molded Plugs) | Attenuation (3M Combat Arms + Earmuff) | Attenuation (3M Combat Arms) |
|---|---|---|---|
| () | |||
- Secondary Fragment Hazard Radius ():
- Isolated detonator: .
- Surface charge on bare soil: (); (); (); ().
- Surface charge on timber or masonry (): .
- Surface charge on steel / metallic targets (): .
- Special shaped charges (any mass): .
- Formula for bare charges between and : where is charge mass in TNT equivalent.
- Altitude and Wind Corrections for Metallic Cuts:
- Elevation correction: Add to ZD for every of elevation above altitude.
- Wind correction: Add to ZD if adverse wind speed exceeds ().
- Unexploded Ordnance (UXO) Destruction Safety Radii (PIA 207):
- Hand grenades: ; Rockets: ; Artillery/Armored shells & missiles: .
Organization and Execution of Firing Sessions
- Technical vs. Tactical Firing Exercises:
- Tirs Techniques: Focus on group-level technical proficiency in charge placement and wiring without combined-arms tactical movement.
- Tirs Tactiques: Executed by a platoon-level element (CDT) wearing full combat equipment within a realistic combined-arms scenario. Employs a dual command chain: D TEC-S/OS for absolute safety, CDT for tactical command.

Minimum Supervision Staffing Levels:
- Daytime Technical Firing: 1 D TEC-S + 1 CDG TEC-S per active AMO.
- Daytime Tactical Firing: 1 D TEC-S + 1 OS per tactical sub-element (Max 2 AMO / 4 elements per ZMO).
- Night Firing: Restricted to 1 single demolition sequence at a time. Requires 1 D TEC-S + 1 OS per element; prior daytime rehearsal on same range mandatory.
Order of Firing Commands (Ordre de Tir des Explosifs):
- Formal command sequence issued by D TEC-S covering: Objectif (Target), Charge (Explosive type/mass), Zones (ZC/ZD radii, shelters), Placement (Placement order), Amorçage (Priming order), Mise à Feu (Firing order), Coordination (Radio/visual signals, OS positions), Divers (Misfire/contingency plans).
Execution Milestones (Jalons):
- Placement: Charges positioned on target.
- Amorçage: Detonators and boosters attached to charges.
- Mise à Feu: Ignition triggered exclusively upon explicit order of D TEC-S.
- Inverted Sequence (Effraction Chaude): For experienced breaching units, D TEC-S may authorize: Priming Placement Firing. In this mode, the order to prime constitutes the final command leading to immediate execution.
Post-Blast Protocol:
- Personnel must remain sheltered for at least 2 minutes after detonation to allow secondary debris to fall and toxic fumes to clear.
- Exception: In tactical explosive breaching (effraction chaude), post-blast waiting time is reduced to 1 second to exploit shock and entry speed.
Elementary Demolition Formulas and Procedures
- Timber Demolition (Pièces en Bois):
- Round Logs and Tree Trunks (Grumes et Troncs):
- Block/PEM Surface Charge: where is charge mass in , and is trunk perimeter in meters ().
- Detonating Cord Ring + Tipping Charge (Charge de basculement):
- CD turns wrapped in pyramid formation at height:
- Tipping charge placed on the side of intended fall direction:

Squared Timber (Équarris):
Surface charge placed on wide face: where is mass in , and are cross-section sides in meters (applicable for diagonal between and ).
Steel and Metallic Target Demolition (Pièces Métalliques):
Safety hazard radius ZD = .
Simple Steel Plates (Plaques Simples):
- For plate thickness : where is explosive mass in , and is thickness in .
- For plate thickness :
- Minimum linear density for PEM = .
- Number of PETD 250g blocks in square bundle cross-section: where is block mass in , and is block length in .
Composite / Multi-Layer Steel Plates (Plaques Composées):
- For total thickness across layers:
Round Steel Bars (Barres Rondes):
- Using PETD blocks ( or perimeter ): where is in grams, in . Split into 2 opposing offset half-charges ().
- Using PEM Plastic (): where is in grams. Placed as a half-crown collar of length .
Steel Cables (Câbles Métalliques):
- Using PETD blocks (): (in grams).
- Using PETD blocks (): Split into 2 offset half-charges ().
- Using PEM Plastic (): (in grams). Formed into a full wrap-around collar of length .
Structural Steel Beams (IPN, HPN, UPN):
- Divide section into elementary web and flange plates; compute individual plate charges and link with detonating cord.
Specialized Equipment and Infrastructure Demolition
Railway Demolitions (Voies Ferrées):
- Single rail breach ( gap): PETD placed against rail web between ties.
- Rail + Tie destruction ( gap): Wooden tie = ; Concrete tie = .
- Rail segment destruction ( gap): "Couple de cavalerie" system using two charges placed apart.
- Switch destruction (Aiguillages): Two charges wedged between switch blades and stock rails from point.
- Frog / Crossing destruction (Croisements): Two charges or one charge inside frog V-point.
Utility Pole Demolitions (Poteaux):
- Wooden poles: (in grams). Standard diameter pole () requires PEM or 4x 250g PETD blocks.
- Reinforced Concrete Poles (Rectangular section ):
- Charge at height: Domestic line = ; High-voltage transmission line = (spalls concrete to buckle rebar).
- Charge at ground level: where is in , and in meters.
Barbed Wire Obstacles: Concentrated charge clears a radius breach.
Vehicles and Aircraft:
- Automobiles/Trucks: placed on engine block, gearbox, or drive shaft. Motorcycles: on engine.
- Tracked Armor: placed on final drives and track tensioners.
- Helicopters: on main rotor drive shaft + in turbine assembly.
Specialized Charges and Ordnance Specifications
- Shaped Charges (Charges à Effet Dirigé):
- Utilize a cavity liner (forged red copper) to generate hypervelocity metal jets. Requires standoff legs and polystyrène spacer blocks for underwater employment.
- CPER LEG MLE F1 (Light Perforating): Mass ( Hexolite 50/50). Penetrates armor steel ( hole) or concrete ( hole).
- CPER MOY MLE F1 (Medium Perforating): Mass ( Hexolite 60/40). Penetrates armor ( hole) or reinforced concrete ( hole).
- CPER LOU MLE F1 (Heavy Perforating): Mass ( Hexolite 60/40). Penetrates armor ( hole) or reinforced concrete ( hole).
- CPER SOL MLE F1 (Soil Perforator): Mass ( Hexolite). Adjustable tripod. Blasts a deep borehole ( entry, cavity) in soil.
- CCOU LEG MLE F1 (Light Cutting): Mass ( active, 2x 50cm elements). Cuts steel plate or reinforced concrete.
- CCOU MOY MLE F1 (Medium Cutting): Mass ( Hexolite, 5x 20cm elements). Cuts steel or reinforced concrete at standoff.
- CCOU LD 62 (Heavy Cutting): Mass ( Hexolite, 7x 15cm elements). Cuts armor or heavy reinforced concrete.
- Charge de Forage et de Destruction MLE F1 / F1A: Mass ( Hexal 70/30 pellets). Comprises 1 head container + 3 standard containers + 3 hexocire boosters + CD. Inserted into boreholes for deep cratering.
- Charge Allongée Modèle F1 (CA MLE F1): Mass ( Hexolite). Assembly of 8 cylindrical elements ( total length, diam). Clears breach in minefields, in barbed wire, or in concertina.
Explosive Breaching (Effraction Chaude) Techniques
Operational Concept:
- Rapid creation of entry points through doors, windows, or light partitions using minimal explosive quantities to achieve shock, disruption, and immediate entry.
- Noise exposure limit under occupational health guidelines: 140 dB (C) peak in open air after hearing protection.
Breaching Charge Formations:

- Sandwich Construction: Detonating cord strands placed between strips of rubber, fire hose, or heavy plastic tape backed with double-sided adhesive. Attenuates rearward shockwave and directs energy into target.
- Charge en "C": detonating cord loop placed over lock mechanisms of single-lock wood/metal doors.
- Charge en "I": linear detonating cord strip taped vertically between handle and door frame.
- Charge "Toute Hauteur": Full-height charge (e.g., 3 strands of CD = for a door = TNT eq). Used for multi-point locking doors.
- Charge "Toute Largeur": Full-width linear charge placed along the bottom frame strand of window sashes.
- Bande Explosive Autocollante (BEA):
- Flexible self-adhesive explosive strip (); active mass ( TNT eq). Placed along hinge side of doors or light brick/gypsum walls to shear hinges cleanly.
Corrected Shock Zones and Barrier Attenuation
- Physics of Wave Reflection:
- Detonation generates an incident shockwave. Interaction with solid barriers or ground creates reflected waves. Near the ground, incident and reflected waves merge into a Mach stem (onde de Mach) with elevated peak overpressure below the triple point (point triple).

Wall Shielding (Corrected ZC behind Wall from Charge):
- Operators must stand close to wall ( behind wall) and at least away from wall edges to avoid diffracted wave edges.
- For charges TNT eq behind a solid wall with earplugs: Corrected ZC = ; required setback behind wall = .
Corner Shielding (Corrected ZC behind Building Corner):
- Charge must be positioned at least away from corner.

- For charges TNT eq with earplugs: Operator stance distance behind corner = at an angle relative to wall face.
Emergency Procedures, Misfires, and Transport Safety
Misfire (Raté) Management Protocols:
- A misfired charge is classified as dangerous unexploded ordnance (UXO). Tactical training is immediately halted; range remains locked down.
- Pyrotechnic Misfire:
- Observe for smoke. If smoking, maintain shelter. If no smoke, wait 30 minutes.
- D TEC-S approaches alone. Without moving or touching the misfired charge, place an elementary counter-charge ( PETD or single detonator) alongside; wire line, retreat, fire, and wait 2 minutes.
- Electric Misfire:
- Attempt second fire. If still failed, disconnect exploder, short-circuit leads, wait 5 minutes.
- D TEC-S approaches alone, places counter-charge, fires, and waits 2 minutes.
- Shock Tube (MAFTOC) Misfire:
- If TOC uninitiated (white color): Attach secondary MAFTOC via connector and refire.
- If TOC initiated (grey color): Wait 10 minutes; place counter-charge, fire, and wait 2 minutes.
Unpriming (Désamorçage) Rules:
- Unpriming a known, intact system must be performed exclusively by the original operator who primed it.
- Pyrotechnic/Mixed: Re-engage safety pin/cap on igniter, extract detonator from charge, store in safety container, and disconnect CD branch lines.
- Electric: Disconnect exploder key, short-circuit lead wires, extract detonators, re-cap wires, and store in safety box.
- NEVER attempt to unprime an unknown or improvised device (EOD team required).
Transport and Storage Safety (ADR / TMD):
- Hazard Divisions: 1.1D (bulk explosives, CD, PETD, PEM, special charges); 1.4S / 1.4D (safety fuse, igniters); 1.4B / 1.4S (detonators).
- Detonators and secondary explosives must be transported in separate compartments/vehicles.
- Exemptions under active material limit: Standard driver, un-marked military vehicle, 2kg ABC extinguisher.
- Exemptions under military exercise orders (IM 5186 / TMD OPS): Transport between military depots/ZST-Mu and range exempt from ADR marking and speed restrictions, provided two trained drivers, fire extinguishers, written movement orders, and sealed original packaging are used.