Specialized Combat Explosive Firing Guide (TEC-S)

Overview and Employment Domains of Explosive Firing

  • Regulatory Framework and Scope:

    • The operational implementation of explosives in the French Army is governed by official doctrine and technical manuals under two distinct domains: Interarms Combat Explosive Firing (Tir Explosif de Combat Interarmes - TEC-IA) and Specialized Combat Explosive Firing (Tir Explosif de Combat Spécialisé - TEC-S).
    • Manual PFT GEN 3.12.14 establishes regulations, procedures, and safety rules for specialized explosive firing, including elementary destructions, tactical explosive breaching (effraction chaude), and specialized equipment demolition.
    • The manual applies primarily to Engineer units (Arme du génie), Land Special Forces (Forces Spéciales Terre - FST), and Explosive Ordnance Disposal (EOD) personnel.
  • Comparison of Employment Domains:

    • TEC-IA Domain (PFT GEN 3.12.12):
    • Covers basic explosive employment for non-engineer, conventional combined-arms units.
    • Aimed at destroying dangerous unexploded ordnance pursuant to PIA 207 (MESSEC) and performing simple surface destructions.
    • TEC-S Domain (PFT GEN 3.12.14 and PFT GEN 3.12.15):
    • Modernizes advanced explosive techniques for high-intensity warfare environments.
    • Integrates physiological constraints from detonation blast waves, mechanical shock effects, tactical combined-arms tempo, and structural architecture of target infrastructures.
    • Introduces reduced safety distances for tactical explosive breaching (effraction chaude) by optimizing charge sizing and leveraging structural barriers and corner attenuation.
  • Domain Compatibility and Interoperability:

    • Personnel authorized under TEC-S are fully qualified to lead or assist in TEC-IA activities, provided they comply with PFT GEN 3.12.12 regulations.
    • Personnel participating in a TEC-S exercise must be explicitly qualified and authorized under the TEC-S domain.

General Properties and Physics of Explosives

  • Fundamental Definition:

    • An explosive is a chemical substance or mixture which, under appropriate initiation, undergoes an extremely rapid chemical decomposition reaction in detonation mode, generating high-temperature gases under immense pressure.
    • Primary useful effects sought in military demolitions:
    • Overpressure / Shockwave Effect: Characterized by brisance (aptitude to shatter solid materials\text{aptitude to shatter solid materials}), creating cracks and fractures through contact.
    • Projection / Expansion Effect: Driven by high-temperature gas expansion, providing a progressive or sudden pushing and ejection force on fragmented material.
  • Types of Chemical Reactions:

    • Combustion:
    • Propagates via thermal conductivity at a moderate speed (order of centimeters per second).
    • Material burns without explosive shock.
    • Deflagration:
    • Accelerated combustion caused by rapid pressure and temperature rise (order of hectometers per second).
    • Produces an explosive reaction with a progressive pushing force.
    • Detonation:
    • Chemical decomposition coupled with a supersonic shockwave (order of kilometers per second).
    • Produces maximum brisance and brutal mechanical shock.
  • Classification of Explosives:

Classification of Explosives

  • By Sensitivity and Employment:

    • Primary Explosives (Explosifs Primaires): Extremely sensitive to flame, friction, spark, or impact (e.g., lead azide, lead styphnate). Used exclusively in small quantities inside detonators to initiate secondary explosives.
    • Secondary Explosives (Explosifs Secondaires): Relatively insensitive to thermal or mechanical shock; require initiation by the shockwave of a primary explosive or booster charge (e.g., PETN, RDX, Hexolite, Tetryl). Used as main demolition charges.
  • By Mechanical Effect (Brisance):

    • Brisant Explosives: High detonation velocity (>6800 m/s> 6800\,m/s). Capable of shearing steel and solid targets via surface contact without requiring confinement or tamping (bourrage).

    • Less Brisant Explosives: Lower detonation velocity (≈4000 m/s\approx 4000\,m/s). Generate larger gas volumes; require physical confinement (bourrage) to exert a prolonged pushing force (e.g., quarrying explosives).

    • Key Physical Characteristics:

  • Sensitivity: Measured by the minimum energy input required to trigger detonation via initiation, friction, shock, heat/flame, or influence (sympathetic detonation from nearby explosions).

  • Stability: Ability to maintain physical and chemical properties over time under environmental stress (heat, cold, humidity, storage duration). Instability causes exudation, discoloration, or crystallization, altering sensitivity dangerously.

  • Useful Effect / Power: Quantified relative to TNT equivalent (Trinitrotoluene\text{Trinitrotoluene}).

    • Detonation Effects and Hazards:
  • Shockwave / Overpressure: Supersonic pressure pulse causing primary blast injuries and material shattering.

  • Blast Wind / Push Effect: Rapid expansion and subsequent contraction of heated gases, throwing objects and personnel.

  • Thermal Effects: Extreme gas temperatures causing burns and secondary fires.

  • Projections and Fragments: Primary fragments (target/casing material at initial speeds ≈1000 m/s\approx 1000\,m/s) and secondary projectiles (ground debris/dirt at speeds up to ≈100 m/s\approx 100\,m/s).

  • Toxic Smoke and Gases: Carbon monoxide, nitrogen oxides, and oxygen depletion in confined spaces.

  • Ground Vibrations: Seismic transmission causing structural collapse at distance.

  • Indirect Effects: Secondary structural collapse, falling debris (tiles, chimneys), and glass shattering.

    • Human Blast Pathology Categorization:
  • Primary Blast: Internal organ damage caused directly by the supersonic overpressure wave interacting with tissue interfaces (air-tissue boundaries like ear tympanums and lungs).

  • Secondary Blast: Penetrating or non-penetrating trauma caused by flying fragments and debris.

  • Tertiary Blast: Physical displacement and impact of the body thrown against environmental structures by blast wind.

  • Quaternary Blast: Burns, toxic gas inhalation/asphyxiation, and crush injuries from indirect structural collapse.

Architecture and Classification of Demolition Systems

  • System Components:

Composition of a Demolition System

  • Moyen de mise à feu (Firing Source): Generates initial activation energy (pyrotechnic friction igniter, electric exploder, or manual shock tube igniter).

  • Moyen de transmission (Transmission Line): Conveys energy to the priming point (safety fuse MLEN, electric lead wire KL5, or shock tube TOC).

  • Moyen(s) d'amorçage (Priming Means): Detonators and intermediate boosters that generate and distribute the detonation shockwave.

  • Charge(s) de destruction (Demolition Charge): Main explosive blocks (PETD, PEM) or shaped charges placed on the target.

    • Demolition System Configurations:
  • Dispositif de destruction élémentaire simplifié: A single explosive charge where the firing charge and demolition charge are unified.

  • Dispositif de destruction élémentaire: A firing charge initiating a single separate demolition charge.

  • Dispositif de destruction simple: Uses a main detonating cord line (cordeau maître) paired with branch lines (cordeaux dérivés) arranged centrally or laterally to initiate multiple separated charges.

Simple Demolition System

  • Dispositif de destruction multiple: A single booster block or high-capacity detonator simultaneously initiating up to 6 separate branch detonating cords.
  • Dispositif de destruction "Flash": Multiple separated demolition charges initiated simultaneously using individual electric detonators wired in series or parallel without detonating cords.
  • Dispositif de destruction circulaire: Closed loop main detonating cord circuit featuring dual transmission and duplicated branch cords to guarantee detonation transmission across complex targets.

Circular Demolition System

  • Dual Priming and Firing (Double Amorçage / Double Mise à Feu):
    • Designed to eliminate misfire risks on critical targets by redundantly duplicating firing means, transmission lines, and detonators.
    • Double Amorçage: Placing 2 distinct detonators on 2 taped explosive blocks or a single plastic charge (can be dual pyrotechnic, dual electric, dual shock tube, or mixed pyrotechnic/electric).
    • In mixed pyrotechnic/electric dual priming, pyrotechnic ignition is executed prior to electric firing.

Firing Systems and Components

  • Pyrotechnic Initiation Line:

    • Allumeur de Mèche Lente Modèle F1 (AL MLEN F1):
    • Mass: 11 g11\,g; Storage Hazard Class: 1.4S.
    • Contains friction composition and pull-rod system. Features plastic body, safety pin, thread ring, and cap.
    • Mèche Lente Modèle F2 (MLEN F2):
    • Black powder core (6 g/m6\,g/m) enclosed in paper, jute, cotton, and brown polyethylene outer sheath.
    • Diameter: 5.5 mm5.5\,mm; Roll Mass: 250 g250\,g (10 m10\,m roll); Storage Class: 1.4S.
    • Burning Rate: 108 to 132 seconds per meter108\text{ to } 132\text{ seconds per meter}.
    • Mandatory pre-use checks: Inspect for cracks/moisture, refresh tip (cut 2 cm2\,cm), and calibrate (1 m1\,m timed burn test per new roll/climate shift). Minimum allowable operational length = 50 cm50\,cm.
    • Détonateur Pyrotechnique BRISKA Modèle 61:
    • Aluminum tube (38 mm×6.85 mm38\,mm \times 6.85\,mm) containing 0.2 g0.2\,g lead azide/styphnate (primary) and 0.8 g0.8\,g tetryl or PETN (secondary). Storage Class: 1.4B.
    • Crimp onto MLEN F2 using specialized non-sparking crimping pliers.
  • Electric Initiation Line:

    • Exploseur Électronique ITS 100:
    • Dual-housing unit: Electronic unit (580 g580\,g) + removable power source/security key (500 g500\,g, 4 lithium batteries, capacity up to 500 firings).
    • Operating Temperature: −33∘C to +63∘C-33^\circ\text{C to } +63^\circ\text{C}; Maximum line impedance: 500 Ω500\,\Omega.
    • Features line test buttons (L1,L2L1, L2), charge indicator light, and dual firing buttons.
    • Câble Électrique KL5:
    • Dual twisted conductors (each made of 4 copper and 3 steel strands); tensile strength 140 kg140\,kg; length 400 m400\,m on DR8 reel.
    • Must be retired/replaced if containing more than 20 splices (épissures) overall or on the first 100 m100\,m section.
    • Détonateur Électrique Instantané Modèle F3 (DETO EL I F3):
    • Brass tube containing 0.2 g0.2\,g lead azide + 0.8 g0.8\,g PETN. Fitted with 1.5 m1.5\,m insulated leads, short-circuit cap, and 10 mm10\,mm OTAN thread plug. Storage Class: 1.4B.
    • Temperature range: −25∘C to +55∘C-25^\circ\text{C to } +55^\circ\text{C}.
    • Electromagnetic Field Safety Distances (F3 Detonator):
    • Cell phones, Wi-Fi, and Bluetooth devices must be powered off or isolated.
    • Electric firing suspended during thunderstorms.
    • High-Voltage Power Lines: Minimum distance 25 m25\,m; Electric Railway Lines: Minimum distance 3 m3\,m.
    • Non-dotation Radio Transmitters:
      • <30 Watts< 30\text{ Watts}: 3 m3\,m
      • 30−300 Watts30 - 300\text{ Watts}: 10 m10\,m
      • 300−1000 Watts300 - 1000\text{ Watts}: 20 m20\,m
      • 1000−3000 Watts1000 - 3000\text{ Watts}: 30 m30\,m
      • 3000−10000 Watts3000 - 10000\text{ Watts}: 50 m50\,m
      • 10000−30000 Watts10000 - 30000\text{ Watts}: 90 m90\,m
      • 30000−100000 Watts30000 - 100000\text{ Watts}: 150 m150\,m
      • ≥100000 Watts\ge 100000\text{ Watts}: 280 m280\,m
    • Military Transmitters (RFM7800M, BP450 jammer): Minimum distance 1.5 m1.5\,m.
  • Shock Tube Initiation Line (MAFTOC):

    • System MAFTOC (Mise à Feu par Transmission d'Onde de Choc) is a sealed all-in-one unit comprising a manual striker igniter, shock tube (TOC, propagation velocity ≈2000 m/s\approx 2000\,m/s), and a high-strength detonator.
    • MAFTOC Courte: 20 m20\,m TOC (1.53 g1.53\,g active material = 1.95 g1.95\,g TNT eq).
    • MAFTOC Longue: 160 m160\,m TOC (4.4 g4.4\,g active material = 7.52 g7.52\,g TNT eq).
    • Includes a multi-line connector block capable of initiating up to 6 secondary TOC lines simultaneously.
  • Common Priming Components and Boosters:

    • Cordeau Détonant Type Génie (CD):
    • Flexible green waterproof sheath containing PETN core (15 g/m15\,g/m active material = 19 g/m19\,g/m TNT eq); outer diameter 5.5 mm5.5\,mm; total weight 29 g/m29\,g/m; 100 m100\,m spool; storage class 1.1D; detonation velocity ≈7000 m/s\approx 7000\,m/s.
    • Joining techniques: Square knot (nœud droit) or taped splice (10 cm10\,cm length).
    • Branch line knotting: Lark's head knot (nœud tête d'alouette) maintaining an acute angle (<90∘< 90^\circ) oriented in the direction of shockwave propagation.

Lark's Head Knot Angle

  • Raccord Mixte Indétectable Modèle 1952 (RAC MIX ID 52):
    • Dual plastic threaded adapter (10 mm10\,mm and 20 mm20\,mm threads) with rubber compression sleeve to lock safety fuses or detonating cords into standard charge wells.
  • Relais d'Amorçage pour Cordeau Modèle F1 (REL AM CORD F1):
    • Mass 10 g10\,g (3.7 g3.7\,g PETN core = 4.4 g4.4\,g TNT eq). Features 10 mm10\,mm thread and hinged locking clip for CD attachment.
  • Pétard de 250 g Indétectable Modèle 1951 (PETD 250g ID 51):
    • Green plastic block (153×47.4×37.5 mm153 \times 47.4 \times 37.5\,mm); total mass 320 g320\,g; main charge 240 g240\,g Hexolite 60/40 + two 10 g10\,g PETN booster wells (300 g300\,g TNT eq, TNT coefficient = 1.201.20). Storage class 1.1D.
  • Pain Explosif Malléable HEXOMAX (PEM):
    • Flexible plastic explosive block (200×60×30 mm200 \times 60 \times 30\,mm); total/active mass 530 g530\,g (636 g636\,g TNT eq, TNT coefficient = 1.201.20). Contains RDX + binder + 1% DMDNB chemical marker. Storage class 1.1D. Minimum kneaded thickness = 4 mm4\,mm.

Demolition Priming Procedures and Connections

  • Priming Demolition Blocks (Pétards):

    • With Pyrotechnic Detonator: Insert crimped detonator into block well; secure using RAC MIX ID 1952 or electrical tape.
    • With Electric Detonator: Screw threaded F3 detonator directly into the 10 mm10\,mm OTAN well.
    • With Detonating Cord (CD):
    • Via RAC MIX ID 1952: Pass CD strand through fitting into well and tighten sleeve.
    • Via 4-Strand Flat Wrap (Lovage à plat 4 brins): Wrap 4 parallel strands of CD longitudinally along block face and tape securely at both ends.
    • Via 5-Strand Flat Wrap (Lovage à plat 5 brins): Wrap 5 parallel strands across block face; used for circular loops and dual initiation.
    • Via 4-Turn Knot (Nœud 4 tours): Form a loop along block face, wrap 4 tight turns around block end, and pass CD end through loop.
  • Priming Plastic Explosive (PEM HEXOMAX):

    • With Detonator: Use non-sparking wooden/plastic probe to cavity an opening slightly larger than detonator; insert detonator at least 1 cm1\,cm deep; hand-compress plastic around detonator.
    • With Detonating Cord: Tie a knotted loop (boucle nouée) on the CD strand; open the PEM block, embed the knotted loop completely inside the plastic mass, and hand-compress firmly.
  • Priming Detonating Cords:

    • Single Strand with Detonator: Fold CD end into a 5 cm5\,cm loop (ganse); tape detonator flush against both parallel strands along its entire length.
    • Multiple Strands (up to 6) with Detonator: Bundle up to 6 CD strands around detonator shell; tape continuously.
    • Multiple Strands with PEM: Tie a joint knotted loop (boucle nouée) combining all CD strand ends and knead into PEM mass.

Qualifications, Habilitations, and Roles

  • Qualifications and Habilitation Architecture:

Qualifications and Habilitations

  • Qualification: Technical competency awarded upon completing official training courses (I TEC-S, M TEC-S, CATi TEC-S).

  • Habilitation: Annual administrative authority granted by the Administrative Unit Commander (Commandant de la Formation Administrative - CFA) empowering qualified personnel to fill specific operational roles.

    • Role Descriptions:
  • Instructeur de Tir Explosif de Combat Spécialisé (I TEC-S):

    • Regiment-level explosive expert and advisor to the CFA.
    • Directs M TEC-S and M TEC-IA training courses; controls annual habilitation renewals; manages unit RETEX.
  • Moniteur de Tir Explosif de Combat Spécialisé (M TEC-S):

    • Qualified to conduct instruction, supervise explosive preparations, and lead firing ateliers (AMO).
  • Directeur de Tir Explosif de Combat Spécialisé (D TEC-S):

    • Officer or senior NCO (CDS / SOA) holding I TEC-S or M TEC-S, habilitated by CFA.
    • Holds absolute safety and operational authority over the firing range and implementation zone (ZMO).
    • Retains sole authority to order weapon firing (Mise à feu).
  • Chef de Groupe de Tir Explosif de Combat Spécialisé (CDG TEC-S):

    • NCO or team leader holding M TEC-S, habilitated by CFA.
    • Commands an Atelier de Mise en Œuvre (AMO); supervises placement, priming, and firing of charges under D TEC-S control.
  • Officier de Sécurité (OS):

    • Safety officer appointed to assist D TEC-S in monitoring a Sector (SMO) or Atelier (AMO).
  • Chef de la Troupe (CDT):

    • Tactical commander of combined-arms maneuver element (Platoon level). Subordinate to D TEC-S for range safety.
  • Cadre Chargé des Munitions:

    • NCO (M TEC-S / CDG TEC-S) responsible for explosive drawdown, depot management, safety fuse calibration, inventory accounting, and maintaining an emergency destruction lot (lot de destruction) on site.

    • Recurrent Training Requirements:

  • Minimum firing activity: Participated in at least 1 real explosive firing exercise in the preceding 3 years.

  • Annual maintenance: Annual safety refresh lecture by I TEC-S + participation/supervision of at least 1 real or inert explosive session.

Range Safety, Areas, and Environmental Layout

  • Range Infrastructure Categories:

    • Without Permanent Shelter: Maximum allowable charge = 15 kg15\,kg TNT equivalent (timber and masonry targets only).
    • With Permanent Shelter: Max charge up to 650 kg650\,kg TNT equivalent.
    • Specific Breaching Screen (Écran d'effraction):
    • Minimum height = 2.3 m2.3\,m; Thickness = ≥12 cm\ge 12\,cm (reinforced concrete) or ≥75 cm\ge 75\,cm (sandbags/earth merlon); Length = extends at least 1 m1\,m beyond personnel position.
  • Zoning Definitions:

    • Zone de Mise en Œuvre (ZMO): Overall authorized firing range area.
    • Secteur de Mise en Œuvre (SMO): Subdivision of ZMO for up to 1 platoon element (Max 3 SMO per ZMO).
    • Atelier de Mise en Œuvre (AMO): Demolition work site commanded by 1 CDG TEC-S (Max 3 AMO per SMO; Max 2 AMO in tactical firing exercises).

Technical Firing Range Implantation

  • Zone de Choc (ZC): Circular shockwave hazard area around target where personnel, even if shielded, are exposed to primary blast overpressure.

  • Zone Dangereuse (ZD): Circular hazard area around target where unshielded personnel are exposed to secondary fragments and projectiles.

    • Safety Zones and Ear Protection Regulations:
  • Hearing protection is mandatory for all personnel inside ZD.

  • Maximum exposure limit: Personnel located within 2×ZC radius2 \times \text{ZC radius} are limited to a maximum of 5 explosive firings per 24-hour cycle.

  • Unshielded Primary Blast Shockwave Radius (ZC\text{ZC}):

Charge Mass (kgkg TNT eq)30 dB30\,dB Attenuation (Molded Plugs)26 dB26\,dB Attenuation (3M Combat Arms + Earmuff)20 dB20\,dB Attenuation (3M Combat Arms)
≤0.016 kg\le 0.016\,kg (16 g16\,g)7 m7\,m11 m11\,m17 m17\,m
0.016−0.025 kg0.016 - 0.025\,kg9 m9\,m13 m13\,m22 m22\,m
0.025−0.050 kg0.025 - 0.050\,kg13 m13\,m20 m20\,m32 m32\,m
0.050−0.100 kg0.050 - 0.100\,kg15 m15\,m24 m24\,m36 m36\,m
0.100−0.250 kg0.100 - 0.250\,kg20 m20\,m32 m32\,m48 m48\,m
0.250−0.500 kg0.250 - 0.500\,kg25 m25\,m40 m40\,m60 m60\,m
0.500−0.750 kg0.500 - 0.750\,kg30 m30\,m45 m45\,m80 m80\,m
0.750−1.25 kg0.750 - 1.25\,kg35 m35\,m50 m50\,m90 m90\,m
1.25−2.00 kg1.25 - 2.00\,kg40 m40\,m60 m60\,m100 m100\,m
2.00−3.00 kg2.00 - 3.00\,kg45 m45\,m75 m75\,m110 m110\,m
3.00−5.00 kg3.00 - 5.00\,kg55 m55\,m85 m85\,m140 m140\,m
5.00−7.00 kg5.00 - 7.00\,kg65 m65\,m95 m95\,m160 m160\,m
7.00−10.00 kg7.00 - 10.00\,kg70 m70\,m110 m110\,m170 m170\,m
  • Secondary Fragment Hazard Radius (ZD\text{ZD}):
    • Isolated detonator: 20 m20\,m.
    • Surface charge on bare soil: ≤0.3 kg\le 0.3\,kg (100 m100\,m); 0.3−5 kg0.3 - 5\,kg (200 m200\,m); 5−10 kg5 - 10\,kg (250 m250\,m); 10−15 kg10 - 15\,kg (300 m300\,m).
    • Surface charge on timber or masonry (≤15 kg\le 15\,kg): 300 m300\,m.
    • Surface charge on steel / metallic targets (≤10 kg\le 10\,kg): 1000 m1000\,m.
    • Special shaped charges (any mass): 1000 m1000\,m.
    • Formula for bare charges between 15 kg15\,kg and 250 kg250\,kg:     ZD=150×C3\text{ZD} = 150 \times \sqrt[3]{C}     where CC is charge mass in kgkg TNT equivalent.
    • Altitude and Wind Corrections for Metallic Cuts:
    • Elevation correction: Add 10 m10\,m to ZD for every 100 m100\,m of elevation above 400 m400\,m altitude.
    • Wind correction: Add 150 m150\,m to ZD if adverse wind speed exceeds 8 m/s8\,m/s (≈30 km/h\approx 30\,km/h).
    • Unexploded Ordnance (UXO) Destruction Safety Radii (PIA 207):
    • Hand grenades: 250 m250\,m; Rockets: 300 m300\,m; Artillery/Armored shells & missiles: 500 m500\,m.

Organization and Execution of Firing Sessions

  • Technical vs. Tactical Firing Exercises:
    • Tirs Techniques: Focus on group-level technical proficiency in charge placement and wiring without combined-arms tactical movement.
    • Tirs Tactiques: Executed by a platoon-level element (CDT) wearing full combat equipment within a realistic combined-arms scenario. Employs a dual command chain: D TEC-S/OS for absolute safety, CDT for tactical command.

Tactical Firing Scheme

  • Minimum Supervision Staffing Levels:

    • Daytime Technical Firing: 1 D TEC-S + 1 CDG TEC-S per active AMO.
    • Daytime Tactical Firing: 1 D TEC-S + 1 OS per tactical sub-element (Max 2 AMO / 4 elements per ZMO).
    • Night Firing: Restricted to 1 single demolition sequence at a time. Requires 1 D TEC-S + 1 OS per element; prior daytime rehearsal on same range mandatory.
  • Order of Firing Commands (Ordre de Tir des Explosifs):

    • Formal command sequence issued by D TEC-S covering: Objectif (Target), Charge (Explosive type/mass), Zones (ZC/ZD radii, shelters), Placement (Placement order), Amorçage (Priming order), Mise à Feu (Firing order), Coordination (Radio/visual signals, OS positions), Divers (Misfire/contingency plans).
  • Execution Milestones (Jalons):

    1. Placement: Charges positioned on target.
    2. Amorçage: Detonators and boosters attached to charges.
    3. Mise à Feu: Ignition triggered exclusively upon explicit order of D TEC-S.
    • Inverted Sequence (Effraction Chaude): For experienced breaching units, D TEC-S may authorize: Priming →\rightarrow Placement →\rightarrow Firing. In this mode, the order to prime constitutes the final command leading to immediate execution.
  • Post-Blast Protocol:

    • Personnel must remain sheltered for at least 2 minutes after detonation to allow secondary debris to fall and toxic fumes to clear.
    • Exception: In tactical explosive breaching (effraction chaude), post-blast waiting time is reduced to 1 second to exploit shock and entry speed.

Elementary Demolition Formulas and Procedures

  • Timber Demolition (Pièces en Bois):
    • Round Logs and Tree Trunks (Grumes et Troncs):
    • Block/PEM Surface Charge:       C=1.3×p2C = 1.3 \times p^2       where CC is charge mass in kgkg, and pp is trunk perimeter in meters (0.63 m<p<1.88 m0.63\,m < p < 1.88\,m).
    • Detonating Cord Ring + Tipping Charge (Charge de basculement):
      • CD turns wrapped in pyramid formation at 1.5 m1.5\,m height:         Number of turns=p3.14\text{Number of turns} = \frac{p}{3.14}
      • Tipping charge placed on the side of intended fall direction:
      • p<0.80 m→0.5 kgp < 0.80\,m \rightarrow 0.5\,kg
      • 0.80 m≤p≤1.25 m→1.0 kg0.80\,m \le p \le 1.25\,m \rightarrow 1.0\,kg
      • 1.25 m≤p≤1.90 m→1.5 kg1.25\,m \le p \le 1.90\,m \rightarrow 1.5\,kg

Tree Tipping Charge

  • Squared Timber (Équarris):

    • Surface charge placed on wide face:       C=13×a×bC = 13 \times a \times b       where CC is mass in kgkg, aa and bb are cross-section sides in meters (applicable for diagonal a2+b2\sqrt{a^2+b^2} between 0.2 m0.2\,m and 0.6 m0.6\,m).

    • Steel and Metallic Target Demolition (Pièces Métalliques):

  • Safety hazard radius ZD = 1000 m1000\,m.

  • Simple Steel Plates (Plaques Simples):

    • For plate thickness e<5 cme < 5\,cm:       C=eC = e       where CC is explosive mass in kg per meter of cutkg\text{ per meter of cut}, and ee is thickness in cmcm.
    • For plate thickness 5 cm≤e≤8 cm5\,cm \le e \le 8\,cm:       C=2×eC = 2 \times e
    • Minimum linear density for PEM = 0.4 kg/m0.4\,kg/m.
    • Number of PETD 250g blocks in square bundle cross-section:       n=C10×l×Pn = \frac{C}{10 \times l \times P}       where PP is block mass in gg, and ll is block length in cmcm.
  • Composite / Multi-Layer Steel Plates (Plaques Composées):

    • For total thickness e≤8 cme \le 8\,cm across mm layers:       C=e+m×e2C = e + \frac{m \times e}{2}
  • Round Steel Bars (Barres Rondes):

    • Using PETD blocks (d≤6 cmd \le 6\,cm or perimeter p≤18 cmp \le 18\,cm):       C=150×dorC=50×pC = 150 \times d \quad \text{or} \quad C = 50 \times p       where CC is in grams, dd in cmcm. Split into 2 opposing offset half-charges (offset i<d\text{offset } i < d).
    • Using PEM Plastic (1 cm≤d≤10 cm1\,cm \le d \le 10\,cm):       C=100×dorC=33×pC = 100 \times d \quad \text{or} \quad C = 33 \times p       where CC is in grams. Placed as a half-crown collar of length l=3dl = 3d.
  • Steel Cables (Câbles Métalliques):

    • Using PETD blocks (d<5 cmd < 5\,cm):       C=80×d2orC=8×p2C = 80 \times d^2 \quad \text{or} \quad C = 8 \times p^2       (in grams).
    • Using PETD blocks (5 cm≤d≤10 cm5\,cm \le d \le 10\,cm):       C=160×d2orC=16×p2C = 160 \times d^2 \quad \text{or} \quad C = 16 \times p^2       Split into 2 offset half-charges (i<di < d).
    • Using PEM Plastic (2.2 cm≤d≤10 cm2.2\,cm \le d \le 10\,cm):       C=20×d2orC=2×p2C = 20 \times d^2 \quad \text{or} \quad C = 2 \times p^2       (in grams). Formed into a full wrap-around collar of length l=3dl = 3d.
  • Structural Steel Beams (IPN, HPN, UPN):

    • Divide section into elementary web and flange plates; compute individual plate charges and link with detonating cord.

Specialized Equipment and Infrastructure Demolition

  • Railway Demolitions (Voies Ferrées):

    • Single rail breach (40 cm40\,cm gap): 0.250 kg0.250\,kg PETD placed against rail web between ties.
    • Rail + Tie destruction (40 cm40\,cm gap): Wooden tie = 0.500 kg0.500\,kg; Concrete tie = 0.750 kg0.750\,kg.
    • Rail segment destruction (1.8 m1.8\,m gap): "Couple de cavalerie" system using two 0.250 kg0.250\,kg charges placed 1.50 m1.50\,m apart.
    • Switch destruction (Aiguillages): Two 0.250 kg0.250\,kg charges wedged between switch blades and stock rails 2 m2\,m from point.
    • Frog / Crossing destruction (Croisements): Two 0.500 kg0.500\,kg charges or one 1.0 kg1.0\,kg charge inside frog V-point.
  • Utility Pole Demolitions (Poteaux):

    • Wooden poles:     C=1.3×p2C = 1.3 \times p^2     (in grams). Standard 25 cm25\,cm diameter pole (p=0.78 mp = 0.78\,m) requires ≈800 g\approx 800\,g PEM or 4x 250g PETD blocks.
    • Reinforced Concrete Poles (Rectangular section a×ba \times b):
    • Charge at 1.5 m1.5\,m height: Domestic line = 3 kg3\,kg; High-voltage transmission line = 5 kg5\,kg (spalls concrete to buckle rebar).
    • Charge at ground level:       C=65×a2×bC = 65 \times a^2 \times b       where CC is in kgkg, aa and bb in meters.
  • Barbed Wire Obstacles: Concentrated 12.5 kg12.5\,kg charge clears a 3.50 m3.50\,m radius breach.

  • Vehicles and Aircraft:

    • Automobiles/Trucks: 0.500 to 1.0 kg0.500\text{ to } 1.0\,kg placed on engine block, gearbox, or drive shaft. Motorcycles: 250 g250\,g on engine.
    • Tracked Armor: 3 to 10 kg3\text{ to } 10\,kg placed on final drives and track tensioners.
    • Helicopters: 1.0 kg1.0\,kg on main rotor drive shaft + 0.500 g0.500\,g in turbine assembly.

Specialized Charges and Ordnance Specifications

  • Shaped Charges (Charges à Effet Dirigé):
    • Utilize a cavity liner (forged red copper) to generate hypervelocity metal jets. Requires standoff legs and polystyrène spacer blocks for underwater employment.
    • CPER LEG MLE F1 (Light Perforating): Mass 745 g745\,g (355 g355\,g Hexolite 50/50). Penetrates 300 mm300\,mm armor steel (12 mm12\,mm hole) or 500 mm500\,mm concrete (20 mm20\,mm hole).
    • CPER MOY MLE F1 (Medium Perforating): Mass 2.4 kg2.4\,kg (1.435 kg1.435\,kg Hexolite 60/40). Penetrates 300 mm300\,mm armor (16 mm16\,mm hole) or 600 mm600\,mm reinforced concrete (20 mm20\,mm hole).
    • CPER LOU MLE F1 (Heavy Perforating): Mass 12.2 kg12.2\,kg (8.187 kg8.187\,kg Hexolite 60/40). Penetrates 500 mm500\,mm armor (30 mm30\,mm hole) or 1.70 m1.70\,m reinforced concrete (50 mm50\,mm hole).
    • CPER SOL MLE F1 (Soil Perforator): Mass 14 kg14\,kg (6.935 kg6.935\,kg Hexolite). Adjustable tripod. Blasts a 2−3 m2 - 3\,m deep borehole (8 cm8\,cm entry, 15 cm15\,cm cavity) in soil.
    • CCOU LEG MLE F1 (Light Cutting): Mass 15.4 kg15.4\,kg (11 kg11\,kg active, 2x 50cm elements). Cuts 80 mm80\,mm steel plate or 200 mm200\,mm reinforced concrete.
    • CCOU MOY MLE F1 (Medium Cutting): Mass 46 kg46\,kg (30.24 kg30.24\,kg Hexolite, 5x 20cm elements). Cuts 200 mm200\,mm steel or 600 mm600\,mm reinforced concrete at 14 cm14\,cm standoff.
    • CCOU LD 62 (Heavy Cutting): Mass 107.1 kg107.1\,kg (63.826 kg63.826\,kg Hexolite, 7x 15cm elements). Cuts 300 mm300\,mm armor or 600 mm600\,mm heavy reinforced concrete.
    • Charge de Forage et de Destruction MLE F1 / F1A: Mass 55 kg55\,kg (52.31 kg52.31\,kg Hexal 70/30 pellets). Comprises 1 head container + 3 standard containers + 3 hexocire boosters + 20 m20\,m CD. Inserted into boreholes for deep cratering.
    • Charge Allongée Modèle F1 (CA MLE F1): Mass 53.7 kg53.7\,kg (40.688 kg40.688\,kg Hexolite). Assembly of 8 cylindrical elements (12 m12\,m total length, 50 mm50\,mm diam). Clears 2 m2\,m breach in minefields, 4 m4\,m in barbed wire, or 10 m10\,m in concertina.

Explosive Breaching (Effraction Chaude) Techniques

  • Operational Concept:

    • Rapid creation of entry points through doors, windows, or light partitions using minimal explosive quantities to achieve shock, disruption, and immediate entry.
    • Noise exposure limit under occupational health guidelines: 140 dB (C) peak in open air after hearing protection.
  • Breaching Charge Formations:

Sandwich Breaching Charge

  • Sandwich Construction: Detonating cord strands placed between strips of rubber, fire hose, or heavy plastic tape backed with double-sided adhesive. Attenuates rearward shockwave and directs energy into target.
  • Charge en "C": 30−40 cm30 - 40\,cm detonating cord loop placed over lock mechanisms of single-lock wood/metal doors.
  • Charge en "I": 15−30 cm15 - 30\,cm linear detonating cord strip taped vertically between handle and door frame.
  • Charge "Toute Hauteur": Full-height charge (e.g., 3 strands of CD = 6.6 m6.6\,m for a 2.20 m2.20\,m door = 126.4 g126.4\,g TNT eq). Used for multi-point locking doors.
  • Charge "Toute Largeur": Full-width linear charge placed along the bottom frame strand of window sashes.
  • Bande Explosive Autocollante (BEA):
    • Flexible self-adhesive explosive strip (2.10 m×19 mm2.10\,m \times 19\,mm); active mass 138 g138\,g (165 g165\,g TNT eq). Placed along hinge side of doors or light brick/gypsum walls to shear hinges cleanly.

Corrected Shock Zones and Barrier Attenuation

  • Physics of Wave Reflection:
    • Detonation generates an incident shockwave. Interaction with solid barriers or ground creates reflected waves. Near the ground, incident and reflected waves merge into a Mach stem (onde de Mach) with elevated peak overpressure below the triple point (point triple).

Mach Stem Wave Creation

  • Wall Shielding (Corrected ZC behind Wall ≥5 m\ge 5\,m from Charge):

    • Operators must stand close to wall (<5 m< 5\,m behind wall) and at least 1 m1\,m away from wall edges to avoid diffracted wave edges.
    • For charges ≤100 g\le 100\,g TNT eq behind a solid wall with 30 dB30\,dB earplugs: Corrected ZC = 5 m5\,m; required setback behind wall = 0 m0\,m.
  • Corner Shielding (Corrected ZC behind Building Corner):

    • Charge must be positioned at least 1.8 m1.8\,m away from corner.

Corner Attenuation Zone

  • For charges ≤100 g\le 100\,g TNT eq with 30 dB30\,dB earplugs: Operator stance distance behind corner = 2.5 m2.5\,m at an angle ≤30∘\le 30^\circ relative to wall face.

Emergency Procedures, Misfires, and Transport Safety

  • Misfire (Raté) Management Protocols:

    • A misfired charge is classified as dangerous unexploded ordnance (UXO). Tactical training is immediately halted; range remains locked down.
    • Pyrotechnic Misfire:
    • Observe for smoke. If smoking, maintain shelter. If no smoke, wait 30 minutes.
    • D TEC-S approaches alone. Without moving or touching the misfired charge, place an elementary counter-charge (250 g250\,g PETD or single detonator) alongside; wire line, retreat, fire, and wait 2 minutes.
    • Electric Misfire:
    • Attempt second fire. If still failed, disconnect exploder, short-circuit leads, wait 5 minutes.
    • D TEC-S approaches alone, places counter-charge, fires, and waits 2 minutes.
    • Shock Tube (MAFTOC) Misfire:
    • If TOC uninitiated (white color): Attach secondary MAFTOC via connector and refire.
    • If TOC initiated (grey color): Wait 10 minutes; place counter-charge, fire, and wait 2 minutes.
  • Unpriming (Désamorçage) Rules:

    • Unpriming a known, intact system must be performed exclusively by the original operator who primed it.
    • Pyrotechnic/Mixed: Re-engage safety pin/cap on igniter, extract detonator from charge, store in safety container, and disconnect CD branch lines.
    • Electric: Disconnect exploder key, short-circuit lead wires, extract detonators, re-cap wires, and store in safety box.
    • NEVER attempt to unprime an unknown or improvised device (EOD team required).
  • Transport and Storage Safety (ADR / TMD):

    • Hazard Divisions: 1.1D (bulk explosives, CD, PETD, PEM, special charges); 1.4S / 1.4D (safety fuse, igniters); 1.4B / 1.4S (detonators).
    • Detonators and secondary explosives must be transported in separate compartments/vehicles.
    • Exemptions under 20 kg20\,kg active material limit: Standard driver, un-marked military vehicle, 2kg ABC extinguisher.
    • Exemptions under military exercise orders (IM 5186 / TMD OPS): Transport between military depots/ZST-Mu and range exempt from ADR marking and speed restrictions, provided two trained drivers, fire extinguishers, written movement orders, and sealed original packaging are used.