Practical 3&4
prac 3
Aim - find the concentration of 2 unknown solutions (A & B) by measuring how much light they absorb.
You use potassium permanganate (KMnO4KMnO4), which is purple, to make solutions of known concentrations. You then measure their absorbance and compare the unknown solutions against them
Preparing the stock solutions
You weigh out approximately 0.79 g of KMnO₄ and dissolve it in distilled water. transfer it into a 50 mL volumetric flask and add distilled water until the bottom of the meniscus reaches the calibration line
Method
1. Check pipetting accuracy: Pipette 1 mL of water onto a tared balance. It should weigh approximately 1.0 g.
2. Prepare the stock solution: Weigh approximately 0.79 g of KMnO₄ and record the actual mass.
3. Dissolve the KMnO₄: Dissolve it in distilled water, then transfer it into a 50 mL volumetric flask. Rinse the weighing boat, beaker and funnel to ensure complete transfer.
4. Make up the volume: Add distilled water to the 50 mL mark, stopper the flask and invert three times to mix.
5. Prepare standard solutions: Transfer 100, 200, 300 and 400 µL of stock solution into separate 100 mL volumetric flasks. Make each up to 100 mL with distilled water.
6. Load the microplate: Pipette 100 µL of water, each standard and both unknown samples into separate wells. Record which solution is in each well.
7. Perform two-fold dilutions: Mix 50 µL of each unknown with 50 µL of distilled water in separate wells.
8. Measure absorbance: Use a spectrophotometer at 525 nm and record all absorbance readings.
9. Calculate unknown concentrations: Use a calibration graph of standard concentration against absorbance. Multiply the concentration of each diluted unknown by two to calculate its original concentration
Why do we record the acutal mass: The balance might give you 0.78 g or 0.80 g instead of exactly 0.79 g. You use the actual mass to calculate the actual concentration of your stock solution. Otherwise, you would be assuming you had used exactly 0.79 g when you might not have.
How do you know the transfer is complete of KMn04: Rinse the weighing boat, beaker and funnel with distilled water into the volumetric flask. This helps ensure all the KMnO₄ has been transferred.
Why do we invert 3 times: To mix the solution evenly so the KMnO₄ is distributed uniformly throughout the water.
This ensures the solution has the same concentration throughout, making your results more accurate.
Why do we do a two fold dilutions: To halve the concentration of the unknown solution so we can measure its absorbance more easily.
Finding the actual concentration
first we use the mass we collected of KMn04 in order to find out the moles
moles = mass / molar mass (due to the triangle)
the molar mass of KMn04 - 158.04
0.79 / 158 = 0.00499 moles
next we use the concentration, volume and moles calc to find the concentration
concentration = moles / volume plated (volume must always be in litres)
50ml —> 0.050L
0.00499 / 0.050 =0.0998 mol / L
prac 4
Aim - use electricity to separate out DNA molecules based on their size
Small DNA fragments move through the gel easily.
Large DNA fragments get slowed down.
Therefore small fragments travel further than large fragments
why does DNA move?
DNA has a negative charge because of its phosphate backbone.
When an electric field is applied:
DNA is attracted to the positive electrode (+)
DNA moves away from the negative electrode (-)
This is why the wells are placed near the negative electrode.
Negative → DNA starts here ⬇ DNA migrates through gel ⬇ Positive electrode
why cant DNA be seen?
DNA is colourless.
A staining dye is added so DNA bands can be seen under UV light.
Under UV:
DNA appears as glowing bands
Method - part 1
prepare sample by adding DNA sample and loading buffer —> makes the sample heavy this allows it to sink into the well
DNA is invisible therefore add dye in order to see whether loading worked and how far eletrophersis has progressed
centrifuge for 10 seconds, this forces everything to the bottom and the entire sample is collected
remove combs from the gel - when the gel was poured it was a liquid, a plastic comb sat in the gel and when the gel solidified the comb can be removed leaving tiny wells. these wells acts like starting positions for the DNA
place the gel so wells are nearest to the black electrode (negative)
DNA will move towards the positive electrode due to its negative charge (phosphates)
cover the gel in TAE buffer (electricity cannot move effectively through the gel alone), the ions in TAE carry an eletric current, therefore without TAE little current flows and DNA moves poorly
the gel must be submerged as the DNA needs a continous electrical pathway allowing the current to flow throughout the system
why EDTA —> EDTA binds magnesium ions, Many enzymes that destroy DNA require magnesium therefore EDTA therefore protects DNA.
load DNA ladder into lane one. this is DNA fragments of a known size, therefore allowing us to indentify the length of our unknown DNA fragments. example - unknown band lines up with 500bp ladder band, therefore DNA fragment = 500bp
load sample into lane 2, The pipette tip is carefully placed just inside the well. The dense loading buffer makes the sample sink. The sample sits at the bottom of the well.
turn on the power and an eletric field forms (one end negative electrode and one end positive)
why does agrose seperate fragments —> contains tiny pores therefore Small DNA travels furthest.
Large DNA remains closer to well. allow this to run for 60 mins
bubbles observed? - At the electrodes: water breaks down. This produces gases.Bubbles indicate:
✅ electricity is flowing
✅ current is present
turn off the power and move the gel to UV transilluminator, DNA stain binds DNA and fluoresces under UV light and causes the band to glow
Method - part 1
A buffer is a solution that resists changes in pH when small amounts of acid or alkali are added.
First, a 1 M NaOH stock solution is prepared and then diluted to make 0.1 M NaOH.
A HEPES buffer is made by mixing HEPES solution with NaOH.
HCl is added gradually to the buffer and the pH is measured after each addition.
At first, the pH changes only slightly because the buffer absorbs added H⁺ ions.
Once the buffer capacity is exceeded, the pH drops rapidly.
The results are plotted as pH vs volume of HCl added to determine the buffer's effective range.
In Part 1, DNA is separated by gel electrophoresis using TAE buffer.
The TAE buffer conducts electricity and keeps the pH stable so the DNA behaves normally during electrophoresis.
In Part 2, you learn how buffers work and why they are important for maintaining a stable pH.
Therefore, Part 2 explains the chemistry behind the buffer used in Part 1.