Ch14 outline
Chapter 14
Managing Major Incidents
Lecture
I. Introduction
- A fire officer is expected to perform the duties of a first-arriving officer at any incident, including:
- Assuming initial command of the incident
- Establishing the basic management structure
- Following standard operating procedures
- Working within the ICS
- Functioning as a unit, group, or division leader
- This chapter looks at the resources and issues that are involved when commanding a major incident.
II. National Response Framework
- Established by the federal government in March 2008
- Comprehensive
- National
- All-hazards
- Domestic incidents
- Specific authorities
- Best practices
- NRF rules the collection and allocation of federal and federal contractor resources to support NIMS.
- The Homeland Security Act charged the Department of Homeland Security administrator with:
- Building a comprehensive national incident management system with federal, state, and local government personnel, agencies, and authorities to respond to attacks and disasters
- Consolidating existing federal emergency response plans into a single national response plan
- Administering and ensuring the implementation of NRF, including coordinating and ensuring the readiness of each emergency support function under NRF
- Emergency support functions:
- Align categories of resources
- Provide strategic objectives for use
- The Homeland Security Act charged the Department of Homeland Security administrator with:
- The Stafford Act
- The 1974 Robert T. Stafford Disaster Relief and Emergency Assistance Act
- How the federal government deploys resources after an incident occurs is an evolving process.
- Amended in 2007 to provide disaster and emergency assistance to:
- State and local governments
- Tribal nations
- Eligible private nonprofit organizations
- Individuals affected by a declared natural disaster or emergency
- Covers all hazards
- Terrorist events
- Natural disasters
- Supplements state and local efforts to:
- Save lives
- Protect property
- Protect public health and safety
- Lessen or avert catastrophe
- Incident Action Plan
- Basic component of ICS
- All incidents require an action plan.
- Outlines strategic objectives
- States how emergency operations will be conducted
- At most incidents, IAP is simple and can be expressed in a few words or phrases.
- Written IAP is required for large, long, or complex events.
- Can be a lengthy document that is regularly updated and used for daily briefings
- Basic component of ICS
III. Staffing the Incident Management System
- The incident management system can readily expand to handle larger and more complex incidents.
- Managing and supervising fire officers may be assigned to:
- Section
- Branch
- Division
- Group
- Command Staff
- Individuals on the command staff perform functions that report directly to the IC.
- Safety officer
- Liaison officer
- Information officer
- Duties cannot be delegated to other sections.
- Aides
- Fire fighter who is a direct assistant to a command officer
- Some operational-level command officers have regularly assigned aides.
- In other departments, aides are assigned only as needed.
- IC may assign more than one aide at a major incident.
- Can be assigned to other officers in the command structure
- Safety Officer
- Ensures safety issues are managed effectively on scene
- Identifies and evaluates hazardous conditions
- Watches out for unsafe practices
- Ensures safety procedures are followed
- Appointed early in an incident
- Additional qualified personnel may be assigned as assistant safety officers.
- Advisor to the IC with authority to stop or suspend operations if unsafe
- Authority is clearly stated in national standards:
- NFPA 1500
- NFPA 1521
- NFPA 1561
- Several regulations require a safety officer at hazardous material and certain technical rescue incidents.
- These assignments are good practice even if not explicitly required.
- Should be qualified individual with knowledge of:
- Fire behavior
- Building construction/collapse potential
- Firefighting strategy/tactics
- Hazardous materials
- Technical rescue
- Department SOPs
- Incident response
- Occupational safety and health
- Many fire departments have full-time safety officers who perform administrative functions relating to health and safety when they are not responding to emergency incidents.
- Liaison Officer
- IC’s point of contact for outside agencies
- Responsible for exchange of information
- Takes IC’s place by obtaining and providing information or directing people to proper authority
- Liaison area should be adjacent to command post.
- Can also represent fire department directly with another agency, e.g., police
- Public Information Officer
- Gathers and releases incident information to news media and other agencies
- Serves as contact person for media requests
- A media briefing location should be established that is separate from the command post.
- General Staff Functions
- At large or complex incidents, the IC may appoint officers to oversee major components of the operation.
- Four standard components are defined in the ICS model.
- IC decides which (if any) should be activated, when to activate, and who to appoint.
- Positions are assigned only when needed.
- If a position is not assigned, IC manages that function.
- The persons in charge of the four major sections are known as the ICS general staff.
- May operate either at the main command post or different location
- Always in contact with the IC regardless of location
- Operations
- Responsible for actions directly related to controlling the incident
- Fights fires
- Rescues victims
- Treats patients
- Produces most viable results
- IC usually directly supervises this section.
- Operations section chief is used at complex incidents so IC can focus on overall picture.
- Responsible for actions directly related to controlling the incident
- Planning
- Responsible for collection, evaluation, dissemination, and use of information relevant to the incident
- Works with:
- Status boards
- Preincident plans
- Building construction drawings
- Maps
- Aerial photographs
- Diagrams
- Reference materials
- Responsible for developing and updating IAP
- Often resembles scheduling department at the company
- Must be in close and regular contact with all other sections
- IC activates when information needs to be obtained/managed/analyzed.
- Planning section chief reports directly to IC.
- Examines current situation
- Reviews available information
- Predicts probable course of events
- Prepares recommendations for strategy/tactics
- Keeps track of resources
- Provides IC with regular situation and resource reports
- May be delegated to subunits
- Resources
- Situation
- Documentation
- Demobilization
- Technical specialists
- Logistics
- Responsible for supplies, services, facilities, and materials
- Logistics section chief reports directly to IC.
- Responsible for:
- Fuel
- Food and refreshments
- Water/foam
- Bulldozers/equipment
- Similar to purchasing and support services
- Ensures adequate resources are always available and functional
- Routinely performed by personnel assigned to support services
- Works in the background to support operations section
- May include subunits
- Supply
- Rehabilitation
- Facilities
- Ground support
- Communications
- Food
- Medical
- Finance/Administration
- Responsible for the administrative, accounting, and financial aspects of an incident, as well as any legal issues
- Not activated at most incidents
- May be needed at large-scale and long-term incidents, particularly when outside resources are needed quickly
- Natural disaster
- When state or federal reimbursement is expected
- During a hazardous materials incident in which reimbursement may come from third party
- Equivalent to the finance department
- Accounts for activities
- Pays the bills
- Ensures there is enough money
- Keeps track of costs
- May incorporate subunits
- Time
- Procurement
- Compensation and claims
- Cost
IV. Tactical-Level Incident Management
- Divisions, groups, and units are where the strategy specified in the IAP is converted into action.
- Supervising and managing fire officers will be commanding these incident management assignments.
- Divisions, Groups, and Units
- Tactical-level management elements
- Used to assemble companies and resources for a common purpose
- As incident grows, IC can establish units to place multiple resources under one supervisor.
- Keeps IC’s span of control within desired limits
- Provides direct coordination of common efforts
- These organizational elements are particularly useful when several resources are working near each other.
- Assigned supervisor can directly observe and coordinate the actions of several crews.
- Divisions: represents geographic operation
- Most often used during routine operations
- Provides effective coordination of different companies’ tactics
- Coordinated by division supervisor
- Groups: represents functional operation
- Alternate way of organizing resources
- Responsible for performing an assignment
- Often work within more than one division
- Sometimes groups are established with both functional and geographic designations.
- Units: generic term; can be either geographic or functional
- Smallest organizational element within the incident management system
- More frequently used at large or complex incidents
- Division/Groups/Unit Supervisor Responsibilities
- In many cases, a company-level officer is assigned by the IC to function as a division/group/unit supervisor.
- When additional command officers arrive, the supervisor might be relieved by a chief officer and revert to functioning as a company-level officer.
- Directly supervises and monitors the operations of assigned resources and provides updates to command
- Uses an appropriate radio designation
- Completes objectives assigned by command
- Accounts for all assigned companies and personnel
- Ensures operations are conducted safely
- Monitors work progress
- Redirects activities as necessary
- Coordinates actions with related activities and adjacent division/group/unit supervisors
- Monitors welfare of assigned personnel
- Requests additional resources as needed
- Provides IC with essential and frequent progress reports
- Reallocates/releases assigned resources
- Division, group, and unit supervisors all function at the same level within the ICS, regardless of the rank of the individual who is assigned.
- Supervisors are required to coordinate with each other.
- Effective communication is critical.
- Branches
- A supervisory level established in either the operations or logistics function to provide appropriate span of control
- Span of control might still be a problem even after the IC has established divisions/groups/units.
- In this case, UC can place a branch director in charge of a number of divisions/groups/units.
V. Fire Officer Greater Alarm Responsibilities
- The IC calls for additional resources or greater alarms when more resources are needed at an incident.
- In many cases, IC calls to have stand-by resources immediately available if needed.
- Company-level officer may be called on to perform many duties as an additional resource:
- Reinforcing a fire attack strategy by adding resources
- Relieving an exhausted crew
- Performing support activities, such as salvage, overhaul, evacuations, providing runners for communication
- Maintaining a ready reserve in a staging area
- Performing additional related duties, including tasks that are not traditional fire company tasks but are time or mission critical
- Additional resources may be dispatched as strike teams or task forces, as opposed to individual companies.
- Companies are directed to combine forces and operate as a group.
- Staging
- A standard procedure to manage uncommitted resources at the scene of an incident
- Staged resources stand by uncommitted and wait for instructions at a predetermined location.
- Usually some distance away
- Allows IC to determine most appropriate assignment for each unit
- Many fire departments have policies that automatically commit one or two first-arriving companies to the incident and direct all others to level I staging.
- Later-arriving units remain uncommitted and wait for instructions.
- SOPs guide
- When units stage
- Where they stage
- How they communicate with IC
- Level II staging
- Used for greater alarm incidents
- Directs responding companies to designated stand-by location
- Designated officer supervises staging area and assigns units as requested.
- The IC might direct the staging officer to maintain a minimum level of resources in the staging area.
VI. Task-Level Incident Management
- Individual companies (single resources) operate at the task level.
- Basic work unit assigned to perform most emergency scene tasks
- Certain types of tasks are routinely assigned to engine and ladder companies.
- Company-level officer role is to supervise a group of fire fighters who are operating as a company at the task level.
- At a simple incident, the company-level officers report directly to the IC.
- When divisions/groups/units are established, company-level officers report to their assigned supervisor and continue to supervise the operations of their respective companies.
- Sometimes, assigned supervisor is one of the company-level officers.
- Company-level officers advise supervisor of work progress.
- All requests for additional resources or assistance must go through supervisor.
- Task Forces and Strike Teams
- Groups of single resources that have been assigned to work together for specific purpose or period of time
- Grouping resources reduces the span of control by placing several units under a single supervisor.
- Task force: two to five single resources assembled to accomplish specific task
- Operates under supervision of task force leader
- Usually one of the company-level officers
- All communications are directed to task force leader.
- Strike team: five units of the same type with assigned leader
- Operates under supervision of strike team leader
- Usually a command officer
- Commonly used for wildland fires
- All communications are directed to the strike team leader.
- EMS strike teams are often organized to respond to multicasualty incidents or disasters.
- Three strike team leaders are easier to manage than 15 single resources.
- Greater Alarm Infrastructure
- Small fire departments have limited infrastructure support.
- At major incidents, rehabilitation units may only be available after considerable delay.
- Fire officers should prepare for this possibility by making sure that their apparatus carries enough water and food to support the fire company for a reasonable period of time.
- Wildland operations usually plan for two-day excursions.
- Small fire departments have limited infrastructure support.
VII. Selected Structure Major Incidents Considerations
- Single-family dwellings, mid-rise dwellings, and high-rise structures all require special considerations due to differences in structure.
- Single-Family Dwellings
- The most frequent location of civilian fire deaths and fire-related injuries is in the home.
- They are not subject to fire prevention inspections.
- Balloon frame construction was common until the 1930s.
- Fires can spread rapidly in void spaces.
- Single-family dwellings constructed since 1980 often have an open geometry design with lightweight structural components.
- Fire can spread rapidly in these buildings too.
- Hazards include:
- Faulty electrical wiring
- Structural changes
- Hoarding situations
- Storage area for retail business
- Home-based businesses
- Converted spaces are often not code-compliant
- Several families living together in one house
- Mid-Rise Multifamily Dwellings
- Often type V construction
- Very popular
- Creative building designs create voids and architectural features that limit fire company’s ability to open and check ceilings for fire extension.
- Newer multifamily dwellings have extensive insulation.
- High peak heat release furniture and tighter insulation mean that this type of building retains much more heat than older buildings.
- Internal exposures suffer more heat damage.
- Higher chance of fire spread
- Lightweight wood trusses require minimal damage to collapse.
- Multifamily dwellings with NFPA-compliant 13R automatic sprinkler systems provide greater protection to the occupants but may increase the degree of difficulty for the fire fighters.
- Buildings will be taller with longer hallways.
- Apparatus access may be restricted by landscaping.
- The preincident plan should identify the best apparatus access positions and the hose lays required to get to every space in the building.
- Make sure:
- Apparatus can actually get into gated communities
- Prompt access is ensured every hour of the day
- High-Rise Considerations
- A working fire within a high-rise structure requires:
- More fire fighters
- An expanded ICS
- Planning, operations, and logistics sections
- Command staff
- High-rise fires require a tremendous number of personnel to be deployed in a carefully concerted effort to achieve the strategic objectives.
- Crew size has dramatic effect on results.
- Managing a high-rise fire requires dividing the incident into manageable units, each with a supervisor.
- May require a staging area manager
- All fire officers must understand their relationship within ICS.
- The fire officer may also be called on to fill a position within the logistics section.
- Support branch
- Headed by support branch director
- Responsible for adequate supplies, personnel, and equipment
- Spare SCBA are the first priority.
- Service branch
- Headed by service branch director
- Responsible for communications and rehabilitation
- Support branch
- A base is an area where the primary logistics functions are coordinated and administered.
- May be co-located with incident command post
- Only one base per incident
- In a high-rise fire, it is important to gain control of the lobby quickly.
- Lobby control officer:
- Controls entry and exit of civilians and fire fighters
- Oversees use of elevators
- Operates local communication system
- Assists in HVAC control
- Reports to logistics section chief or IC
- Lobby control officer:
- Stairwell support group
- These fire fighters move equipment and water supply hose lines up and down the stairwells of the high-rise building.
- Unit leader reports to support branch director or logistics section chief.
- One practice is to position fire fighters on every third floor.
- Equipment moves up in an assembly line.
- Recommended practices
- Comply with your organization’s standard operating procedures.
- Consider bringing the big attack line first.
- Beware of weather conditions.
- Assemble an adequate crew.
VIII. Postincident Analysis
- Situations that involve multicompany operations should be reviewed from the perspective of how well the overall team performed, in addition to individual fire officers conducting company-level reviews.
- The format depends on the nature and magnitude of the incident.
- It is relatively easy to gather the companies that were involved in a one-alarm fire to conduct a basic review of the incident soon after the event.
- The critique of a large-scale incident, by comparison, can be a major event.
- Some organizations conduct critiques only for unusual incidents or situations where something obviously went wrong.
- This creates the impression that nothing can be learned from ordinary-sized incidents.
- A review should always be educational, not to place blame.
- Approach every postincident review in a nonthreatening manner and provide an open format for discussion as an aid to future training.
- Reviews should be routine and systematic.
- The same basic factors should be examined and discussed.
- Many fire departments have a standard critique format.
- Preparing Information for an Incident Review
- A multicompany incident review is conducted by the IC.
- Preparation is often delegated.
- Obtain information about:
- The situation leading up to the incident
- Whatever occurred before arrival
- This frames the discussion from an operational perspective.
- Reveals important factors that were unknown before incident began
- Allows individuals to understand what they observed at the time but didn’t have time to interpret
- For a building fire, this includes:
- Review of building
- Size and arrangement
- Construction type
- Date of construction
- Modifications or renovations
- Known relevant history
- Built-in protection features
- Firewalls
- Automatic sprinklers
- Standpipes
- Alarm and detection systems
- Structural factors that affect fire spread
- Unsealed openings around pipes
- Open shafts
- Concealed space
- Occupancy
- Occupied
- Unoccupied
- Vacant
- Abandoned
- Under renovation
- Business type
- Fire load/contents
- Review of building
- Some questions may not have answers at the time of the postincident review but should still be considered in planning for this critique.
- Where, when, and how did the fire start?
- What was burning initially, and how did the fire spread?
- Did the fire involve the contents or the structure, or both?
- Who discovered the fire, what did they observe, and when was the fire department called?
- If the desired information about the building and occupancy is not readily available, the officer gathering this information can refer to several sources.
- Inspection file
- City department/building permits
- Preincident plans
- Indeed, it is an excellent quality-control technique to compare the preincident plan information with the situation that was actually encountered.
- The postincident review is also a good opportunity to determine whether the information on file was useful to the IC.
- Fire investigator can provide information about fire cause and origin.
- Communications center can provide information about source of alarm and resources that responded.
- Obtain:
- Recording of the incident communications
- Photographs and videos of the incident
- Additional information about the water system
- All of this information should set the stage for the analysis of the events.
- Be prepared to present all of this information in a manner that is factual and informative.
- Conducting a Critique
- Scheduled for as soon as convenient after incident, while allowing adequate time to gather information
- Best to capture information while it is still fresh
- With a small-scale incident, it may be possible to have all of the involved companies in attendance.
- The attendance at a critique of a larger-scale incident could be limited to company officers and command officers.
- Overview
- Background and basic information
- Include timeline and units dispatched
- Describe situation on arrival and actions taken
- Include initial IC’s role
- Proceed along timeline.
- Each successive company should take a turn.
- Draw a plot layout of the area and have officers locate their positions.
- Gradually produce a complete diagram of incident.
- Insert photographs, videos, recordings.
- If a large number of companies were involved in the incident, the presentation could be made by division/group/unit officers.
- Moderator should keep analysis targeted at:
- Key factors
- SOPs
- The best way to evaluate the effectiveness of procedures is to determine whether following them actually produced the anticipated results.
- If a deviation from standard procedures occurred, the reasons and the impact should be discussed.
- Next, officer directing critique should provide perspective/assessment.
- Include both positive and negative factors.
- Evaluate outcome in terms of where fire was stopped and how much damage occurred.
- Praise should be widely distributed.
- Have attendees identify positive and negative points and items for future improvement.
- List on board for all to see as final product.
- Documentation and Follow-Up
- The last step is to write a summary for department records.
- Present this in a standard format.
- Many departments use a form.
- Allows information to be stored in a consistent manner
- Ensures all relevant information is collected
- Should include recommendations for changes in procedures, if any
- Completed package should be forwarded to appropriate parties for review and follow-up.
- Training division should receive a copy.
- Recommendations for policy changes should be forwarded to appropriate personnel.
- Completed report should include:
- NFIRS information
- Operational analysis information
IX. Summary
- The National Response Framework (NRF) is a comprehensive, national, all-hazards approach to domestic incident response that describes specific authorities and best practices for managing incidents.
- The National Incident Management System (NIMS) provides a consistent template for managing incidents.
- Federal, state, and some private-sector and nongovernmental entities organize their resources and capabilities under 15 emergency support functions (ESFs).
- The “Stafford Act” is the administrative regulation that describes federal government disaster and emergency assistance to state and local governments, tribal nations, eligible private nonprofit organizations, and individuals affected by a declared natural disaster or emergency.
- The incident action plan (IAP) outlines the strategic objectives and states how emergency operations will be conducted.
- Command staff under NIMS requires a minimum of an incident commander and safety officer.
- The complete command staff positions under NIMS include incident commander, safety officer, liaison officer, and public information officer.
- The four major components of emergency scene operations under NIMS are operations, planning, logistics, and finance/administration.
- The individuals in charge of the four components of emergency scene operations are known as ICS general staff.
- Tactical-level is where strategy specified in the IAP is converted into action.
- Tactical-level management elements are dispersed into divisions, groups, and units.
- Division represents a geographic operation, such as one floor or one side of a building.
- Group represents a functional operation, such as ventilation.
- Unit is a generic term that can be applied to either a geographic or functional component.
- Company-level officers can be assigned by the incident commander to function as a division/group/unit supervisor.
- A branch is a supervisory level to provide an appropriate span of control.
- Staging is a standard procedure to manage uncommitted resources at the scene of an incident.
- Individual companies operate at the task level.
- A task force includes two or five single resources assembled to accomplish a specific task.
- A strike team consists of five units of the same type with an assigned leader.
- The most frequent location of civilian deaths and fire-related injuries is in the home.
- Wood-frame, multifamily, 3- to 7-story dwellings of Type V construction have been the largest type of housing units recently constructed.
- High-rise fires require a tremendous number of personnel and resources to make an effective fire attack, requiring dividing the incident into manageable branches.
- A high-rise stairwell support group practice is to place a fire fighter on every three floors to move hose and equipment up in an assembly-line fashion.
- The primary purpose of a postincident analysis is to serve as an educational and training tool.