Network Analysis and Design: Flow Analysis Guidelines and Application
Components of the Network Analysis and Design (NAD) Process
The Network Analysis and Design process (BITS 2333) follows a systems approach, transitioning through several distinct phases to reach a final implementation.
Requirement Analysis: This phase involves identifying systems and network services, characterizing those services, and gathering requirements for users, applications, hosts, and networks. It includes defining service metrics, performance thresholds, and levels, as well as characterizing behavior through data sources and sinks.
Flow Analysis: This stage builds upon requirement analysis by establishing flow models, defining boundaries, analyzing distributions, and developing flow specifications.
Logical Design: Focuses on technology choices, interconnection mechanisms, network management, and security.
Physical Design: Involves cable plant design options, the placement of network equipment, and the creation of network diagrams or diagramming worksheets.
Addressing and Routing: Establishing routing flows and developing a comprehensive addressing and routing strategy.
Flow Analysis Process Model
The process of flow analysis is a structured model designed to translate requirement specifications and application maps into a concrete plan for the network. The steps include:
Establishing Flow Boundaries: Determining where flows cross well-defined areas.
Identifying Backbone/Composite Flows: Combining individual flows that transit a specific area into a consolidated view.
Developing Flow Specifications (Flowspecs): Using algorithms and characteristics to define the performance and capacity needs.
Identifying Capacity/Service Plans: Determining the resources required to meet the service and capacity targets.
Inputs to the Model: Requirement specifications, Application Maps, Flow Models, Flow Distributions, and Flow Characteristics.
Guidelines on Applying Flow Models
Starting with a flow model provides a quick assessment of likely traffic patterns in the design environment.
Utility: Models help in analysis and design by providing a rapid assessment of likely flows (e.g., peer-to-peer, client-server). They allow for the generalization of flows and the identification of sources and sinks to complement the analysis.
Common Flow Models:
Peer-to-peer.
Client-server.
Cooperative-computing.
Distributed-computing.
Case Study 1: Data Mining Project Environment
This case study focuses on a data mining project where a group gathers, compiles, and organizes varied data (e.g., insurance, census, advertising, medical).
Technical Profile: Large databases requiring specialized software for rapid searches. A metadata model is often used to structure data hierarchically.
Application Scope:
Application A: Web-based search engine.
Application B: Data Storage and Archival Application.
Application C: Data Migration Tool.
Environment Design: The project spans multiple campuses (Campus X, W, Y, and Z). Physical nodes include Web Servers, Caches, and Storage/Archival systems. Empty circles on an application map represent potential data sources and sinks.
The Library Analogy for Storage, Cache, and Web Server Flow
To understand the flow in large-scale systems (Storage Cache Web Server), consider a university library with three zones:
Deep Archive (Storage): A basement vault storing thousands of books rarely accessed and far from students.
Main Shelf / Reading Room (Cache): A curated shelf of popular books placed near the entrance for fast access.
Librarian’s Counter (Web Server): The front desk that hands books directly to the students (clients).
Outcome: When a student (client) asks for a book, it is already at the counter. This results in zero wait time. This represents a payoff where data is staged forward through the system before the real request arrives.
Data Movement and Hierarchy in Large Systems
Web Server Role: In large-scale systems, the web server is not a storage device; it is a request handler. The actual data lives in separate database or object storage tiers.
Small Websites: Storage is the Web Server.
Large Systems: Storage Cache Web Server.
Expectations in Case Study 1:
Web servers service user queries and download data locally.
Requests and data are cached locally.
The Storage/Archival system (Campus Z) acts as a data sink for outside sources and a source for caches.
Caches act as sinks when receiving from storage and as sources for local web servers.
Cooperative Computing Environment: Because flows are bidirectional, asymmetric, and involve cache-to-cache and client-server interactions, the environment is categorized as cooperative computing. Devices act as both sources and sinks depending on the application in use.
Guidelines on Establishing Flow Boundaries (FB)
Boundaries acts as thresholds that highlight flows needing special consideration, especially those crossing into the backbone.
6 Steps for Assessing Flow Boundaries:
Identify Sources and Sinks.
Determine if any flow models apply (e.g., distributed computing cluster or parallel system).
Place Flow Boundaries on the model.
Note flows that cross those boundaries for each model used.
Evaluate if the flows crossing boundaries are "Critical Flows."
Prioritize critical flows crossing boundaries for special consideration in the backbone.
Typical Flow Boundary Types:
Local- and Wide-Area Networks ().
Local- and Metropolitan-Area Networks ().
Metropolitan- and Wide-Area Networks ().
Between multiple campuses ().
Between multiple buildings on a campus ().
Between multiple floors within a building ().
Backbones where combined flows transit an area.
Flow concentration points.
WANs where service providers are utilized.
Specialized areas with specific service requirements.
Guidelines on Applying Flow Distributions (FD)
Flow distributions estimate the relative volume of traffic crossing flow boundaries. These are based on flow models, individual applications, and performance requirements.
Distribution Ranges: Generally range from to (local/remote).
Rules of Thumb:
Standard Assumption: local/remote.
Peer-to-Peer: .
Client/Server or Cooperative Computing: is a good starting point if the flow crosses a FB.
Distributed Computing:
Cluster Computing: across FB.
Parallel Computing: across FB.
Capacity Impact Example: If an application requires :
With distribution, the remote requirement is .
With distribution, the remote requirement is .
With distribution, the remote requirement is .
Generalization: If remote distribution is estimated at or , remote bandwidth should be equivalent to local bandwidth for safety.
Finding Flow Patterns and Characteristics
To identify patterns, one must map application environments to locations and identify which flows cross boundaries.
Application Mapping Example:
Application A: Peer-to-Peer, All locations.
Application B: Client-Server, North and South Campuses. (Server at North; clients at North, clients at South).
Application C: Distributed (Cluster Computing), West and South Campuses. (Task Manager at South; nodes at West).
Analysis of Example:
Application B critical flow: Between clients and server. Since of clients are at the South campus and the server is at the North campus, the flow crosses a boundary. This indicates a distribution and a backbone flow.
Application C critical flow: From computing nodes (West) to Task Manager (South). This crosses a boundary between campuses, indicating a distribution () and backbone flow.
Guidelines on Developing Flow Specifications (Flowspecs)
A Flowspec is a device used to combine application performance requirements into flows, serving as a template for requesting, configuring, and verifying services.
Capacity Plan: Generated when combining capacities for Best Effort () applications. It excludes delay and reliability requirements and is used to estimate required network capacity.
Service Plan: Generated when combining capacity, delay, and reliability requirements for both and specified applications.
Initial Assumptions for Flows:
Assumed that all applications are Best Effort ().
Assumed that all flows are peer-to-peer individually until analyzed otherwise.
Case Study Data Mapping:
Application A (Search Engine): Interactive, Best Effort.
Applications B & C (Storage/Migration): Bulk data transfer, Best Effort.
Capacity Requirements and Calculations for Case Study 1
Total capacity requirements derived from behavior analysis:
Total Capacity (Servers to Users): .
Capacity (Caches to Servers): .
Storage to Caches: .
Outside to Storage: .
Calculations for Flow Specifics:
Cache to Server (): flows. .
Cache to Cache flows: flows. .
Storage to Cache: flows. .
Outside to Storage: . Converting to seconds: .
Guideline on Prioritizing Flows
Prioritization is necessary to determine implementation schedules and reduce costs. Parameters for prioritization include the number of users affected, performance characteristics, and distances/locations.
User-Based Prioritization: Ensuring the largest number of users get prioritized service. For example, if (Backbone 2) serves users vs 's , may be prioritized even if its reliability is lower.
Cost/Budget Allocation: Using a budget (e.g., ) based on parameters.
User-Based Allocation: Devotes best equipment to highest user concentrations. A trade-off is that smaller user groups may not meet performance needs.
Capacity-Based Allocation Formula: .
Example for BB1: .