Fuel Cells: Fundamentals, Technologies, and Stationary Applications

Overview

  • Lecture topic: Moderne Energiesysteme with a focus on Brennstoffzellen (fuel cells).
  • Key question: How does energy conversion in a fuel cell work, especially for a single Membranbrennstoffzelle (Membane Fuel Cell, MFC)?
  • Hydrogen as the common fuel for electricity, heat, and combined heat-and-power (CHP) applications.
  • Typical fuel for operation: Erdgas (natural gas) used to generate hydrogen via reforming (Reformierung).
  • Structure of the talk: (1) energy conversion in one MFC, (2) hydrogen source and reforming, (3) two example stationary CHP applications.
  • Historical context: development from Schönbein (late 18th to 19th c.), Grove, Siemens, Ostwald; early concepts and limits of efficiency and materials challenges.
  • Modern drivers: environmental concerns and higher efficiencies spur renewed interest in fuel cells for stationary and mobile uses.
  • Hydrogen can be produced by electrolysis, reforming of fossil/biogenic fuels, or from biomass; renewable hydrogen is often termed a secondary energy carrier.
  • Emphasis on stationary systems in Kraft-Wärme-Kopplung (KWK) and the broad applicability across scales (milliwatts to megawatts).

Core history and concept highlights

  • Sir William Grove (early 19th c.) conceptualized cells as an inverse of electrolysis; Grove’s gas battery inspired later work on practical fuel cells.
  • Werner von Siemens (1880s) pushed the idea aside due to dynamics of dynamos and competing technologies.
  • Wilhelm Ostwald (early 20th c.) quantified theoretical potential for fuel cells; theoretical efficiencies around 83% were forecast, spurring many design proposals.
  • Postwar developments: Francis Bacon built practical early fuel cells (alkaline) with hydrogen and alkaline electrolyte.
  • 1960s: NASA used a low-temperature membrane fuel cell (PFSA) with perfluorinated sulfonic acid polymer membrane in Gemini missions; later alkaline and PAFC/LMS developments followed.
  • End of 1970s and 1980s: hydrogen-based, high-temperature fuel cell research rose due to interest in CO2-free power generation; phosphoric acid fuel cells (PAFC) at ~200°C and solid oxide/fused carbonate developments emerged.
  • 1980s–late 1980s: renewed interest in fuel cells due to energy efficiency and environmental concerns; emphasis on stationary and mobile uses, including automotive concepts.
  • Hydrogen sources: water electrolysis (green hydrogen) and reforming of hydrocarbons/biomass; reforming is dominant for hydrogen production in many systems.

Thermodynamics and fundamental voltages of a single membrane fuel cell (MFC)

  • Overall reaction in an MFC:
    • Anode:
    • Cathode:
    • Overall (simplified):
      ext{H}2 + frac{1}{2} ext{O}2
      ightarrow ext{H}_2 ext{O}
  • Standard reaction enthalpy (formation of water) is exothermic with magnitude ~
    ∣riangleHextupper∣=241.8extkJ/mol\boxed{ \big| riangle H^ ext{upper}\big| = 241.8 ext{ kJ/mol} } for the upper heating value (UHV) pathway and similarly for lower heating value (LHV) cases around 241.8 kJ/mol in the problem's framing.
  • Thermoneutral (enthalpy-based) cell voltage for the upper heating value (UHV):
    Uextthextupper=−riangleHextuppernF extwithn=2 F=96487extC/mol hereforeUextthextupper extapproximately1.48extVU_ ext{th}^{ ext{upper}} = \frac{- riangle H^{ ext{upper}}}{nF} \ ext{with } n=2 \ F=96487 ext{ C/mol} \ herefore U_ ext{th}^{ ext{upper}} \, ext{approximately } 1.48 ext{ V}
  • Thermoneutral (enthalpy-based) cell voltage for the lower heating value (LHV):
    Uextthextlower=−riangleHextlowernF hereforeUextthextlower extapproximately1.25extVU_ ext{th}^{ ext{lower}} = \frac{- riangle H^{ ext{lower}}}{nF} \ herefore U_ ext{th}^{ ext{lower}} \, ext{approximately } 1.25 ext{ V}
  • Gibbs free energy (standard) gives reversible cell voltage: E0=riangleG0nFE^0 = \frac{ riangle G^0}{nF}
    • Upper: \ riangleG0<em>extupper=237.3extkJ/mol E0</em>extupper=237.32F ext≈1.23Vriangle G^0<em>{ ext{upper}} = 237.3 ext{ kJ/mol} \ E^0</em>{ ext{upper}} = \frac{237.3}{2F} \, ext{ ≈ 1.23 V}
    • Lower: \ riangleG0<em>extlower=228.6extkJ/mol E0</em>extlower=228.62F ext≈1.18Vriangle G^0<em>{ ext{lower}} = 228.6 ext{ kJ/mol} \ E^0</em>{ ext{lower}} = \frac{228.6}{2F} \, ext{ ≈ 1.18 V}
  • Entropy change for the reaction:
    riangleS0 =  −44extJmol−1extK−1riangle S^0 \,=\; -44 ext{ J mol}^{-1} ext{ K}^{-1}
  • Nernst dependence (reversible cell voltage as a function of temperature): Eextrev(T)=E0−TnFriangleS0E_ ext{rev}(T) = E^0 - \frac{T}{nF} riangle S^0
    • At 298.15 K (25°C) with CO2/H2O activities set to standard, E_rev ≈ 1.23 V (for upper) or 1.18 V (for lower) giving the reference values.
  • Under standard conditions (T=298.15 K, p=1 atm):
    • Reversible voltage at UH (upper): ~1.23 V; at LH (lower): ~1.18 V.
    • Thermoneutral: Uth^{upper} ≈ 1.48 V; Uth^{lower} ≈ 1.25 V.
  • Ideal (maximum) electrical efficiency per cell, assuming no overpotentials and using HV/LHV references:
    • Upper heating value:
       extetaˉ<em>extidealextupper=E0</em>extupperUextthextupper=1.231.48 ≈ 0.833 (=83.3%)\boxed{ \bar{\ ext{eta}}<em>{ ext{ideal}}^{ ext{upper}} = \frac{E^0</em>{ ext{upper}}}{U_ ext{th}^{ ext{upper}}} = \frac{1.23}{1.48} \,\approx \,0.833 \, (= 83.3\%) }
    • Lower heating value:
      etaˉ<em>extidealextlower=E0</em>extlowerUextthextlower=1.181.25 ≈ 0.945 (=94.5%)\boxed{ \bar{\text{eta}}<em>{ ext{ideal}}^{ ext{lower}} = \frac{E^0</em>{ ext{lower}}}{U_ ext{th}^{ ext{lower}}} = \frac{1.18}{1.25} \,\approx \,0.945 \, (= 94.5\%) }
  • Realistic versus ideal: actual single-cell voltage under load is reduced by overpotentials due to activation, ohmic, and concentration losses.
  • Open-circuit voltage per cell (ruhespannung): around 1.0 V (not equal to the ideal 1.23/1.18 V, or to the thermoneutral 1.25–1.48 V; losses exist). The polarization curve shows four main loss regions:
    • Activation losses (onset) at low current density due to electrode kinetics (catalyst activation).
    • Ohmic losses (linear region) from electronic and ionic resistances.
    • Concentration losses (mass-transport) at high current densities due to limited supply of hydrogen and oxygen to the catalyst layers.
    • The total loss can be expressed as:
      u=Uextth−(extactivation+extohmic+extconcentration)u = U_ ext{th} - \big( ext{activation} + ext{ohmic} + ext{concentration} \big)
  • The maximum electrical power per cell occurs at some intermediate current; at very low current, voltage near open-circuit but power low; at very high current, voltage collapses due to diffusion limits.
  • Practical in-cell example (MEA): if a cell delivers ~0.6 V under load, the corresponding ideal efficiency relative to LH or UH references is:
    • If using LH 1.25 V reference,
      extefficiency =  0.61.25 =  0.48 (48%)ext{efficiency} \,=\; \frac{0.6}{1.25} \,=\; 0.48 \, (48\%)
    • At 0.7 V:
      extefficiency =  0.71.25 =  0.56 (56%)ext{efficiency} \,=\; \frac{0.7}{1.25} \,=\; 0.56 \, (56\%)
  • The polarization curve can be summarized as: at zero current, high voltage; as current increases, voltage falls; the resulting power P = V × I peaks somewhere between.

Single-Cell structure and materials (Membrane Fuel Cell, PEMFC)

  • Core component: Proton exchange membrane (PEM) that is proton-conductive; separates fuel sides (anode) and oxidant side (cathode).
  • Cathode and anode catalysts: typically platinum-based catalyst layers near the membrane.
  • Gas diffusion layers (GDL): carbon fiber paper on both sides to distribute reactant gases to the catalyst surface and to conduct electrons.
  • Bipolar plates: channels machined into plates to supply hydrogen to the anode and air (O2) to the cathode; also serve as electrical contacts.
  • Cell stack composition (7 layers):
    • 2 bipolar plates, 2 GDLs (left and right), 2 catalyst layers, and the central membrane – total 7 layers.
  • Physical dimensions and thickness: typical PEM membranes ~100 micrometers thick in older designs; automotive membranes now ~10–15 μm (significant reduction to enhance performance and reduce costs).
  • Open-circuit voltage per cell is near 1.0 V; under load, voltages drop with current due to loss mechanisms.
  • Stack concept: many cells in series to achieve higher voltage; e.g., 100 cells yield roughly 100 × ~1 V = ~100 V; 200 cells ~200 V; 300 cells ~150–300 V depending on per-cell voltage and design.
  • Practical automotive example: a stack with ~300 cells in series; typical single-area size around DIN A4 for the active area per stack.
  • Real-world examples and components:
    • Bipolar plates made from polymer composite plastic (injection-molded) to simplify channels and gas paths; reduces manufacturing steps.
    • ZBT Duisburg and CPT (Siemens) examples of stacks used in research and industry.
    • U-boat fuel cell stack by Siemens demonstrates long-life, fuel-flexible operation using reformate gas.
  • Performance example (ZBT fuel cell):
    • 20 cells in a stack; open-circuit ~19 V => ~0.95 V per cell.
    • Under load, voltage drops; at around 40 A, power is ~370 W (20 cells × ~9.8 V per cell ≈ 196 V total, delivering ~370 W) – illustrating the high current and power relationship.
  • Teillast (partial-load) operation advantage: PEMFCs often show higher efficiency at partial load than at full load due to higher cell voltage at lower currents; this is a favorable trait for mobile applications (city driving, etc.).

Fuel-cell types, operating temperatures, and typical roles

  • Alkaline Fuel Cell (AFC):
    • Electrolyte: hydroxide (OH−) in solution.
    • Temperature: relatively low (~80°C).
    • Historical use: aerospace/space applications; largely supplanted by PEM due to issues in modern gas streams.
  • PEMFC (Polymer Electrolyte Membrane Fuel Cell):
    • Electrolyte: proton-conducting membrane (e.g., PFSA membranes).
    • Temperature: ~60–80°C.
    • Fuel: hydrogen primarily; minimal tolerance to CO; water management is critical for membrane hydration.
  • PAFC (Phosphoric Acid Fuel Cell):
    • Electrolyte: phosphoric acid; operating around ~200°C.
    • Fuel flexibility with reformate; CO tolerance better than PEM but still needs gas cleaning for high CO.
  • DMFC (Direct Methanol Fuel Cell):
    • Fuel: methanol directly, without reforming; lower power density and efficiency; suited to small-scale or portable applications.
  • MCFC (Molten Carbonate Fuel Cell):
    • Electrolyte: molten carbonate; high-temperature operation; roughly 650–700°C range.
    • Fuel: hydrogen-rich reformates; CO tolerance higher than PEM; supports high-temperature exhaust heat usage.
  • SOFC (Solid Oxide Fuel Cell):
    • Electrolyte: solid oxide (oxide ion conductor, e.g., O2−).
    • Temperature: very high (~1000°C).
    • Fuel flexibility with reformates; very high electrical efficiency potential, especially in hybrid configurations with turbines.
  • Key purity requirements by type (gas inlet hydrogen quality):
    • PEMFC (80°C operation): CO ≤ ~10 ppm (ppm of CO in the hydrogen stream); sulfur compounds also problematic; requires very high purity hydrogen.
    • PAFC (200°C): CO tolerance up to ~1% CO in the gas stream; less strict than PEMFC but still requires gas cleanup.
    • SOFC/MCFC: higher tolerance to CO at high temperatures but still benefit from clean gas streams for longevity and performance; CO/CH4 content affects catalysts and reforming balance.
  • Hydrogen sources and reforming considerations (brief):
    • Direct electrolysis of water to generate hydrogen (green hydrogen) is ideal but energy-intensive; commonly combined with renewable energy.
    • Reforming of hydrocarbon fuels (gas, LNG, LPG, diesel, jet fuel, etc.) to produce hydrogen-rich gas mixtures for PEM or high-temperature cells; requires desulfurization and gas cleanup to meet purity requirements.
    • Typical reforming processes: steam reforming, autothermal reforming (ATR), partial oxidation (POX), and their combinations.
  • Gas clean-up and conditioning steps in reforming pathways:
    • Desulfurization to remove sulfur-containing compounds that poison catalysts.
    • Water-gas shift (WGS) to convert CO + H2O → CO2 + H2, boosting hydrogen yield and reducing CO content.
    • CO cleanup and selective oxidation (SeOx or SeOxidation) to reduce CO to CO2, particularly important for PEMFC at low temperatures to protect catalyst surfaces.
    • Final gas polishing for PEM feed: aiming for CO ≤ 10 ppm and very low sulfur and trace contaminants.

Reforming pathways and gas-quality impacts

  • Steam reforming (SR):
    • CH4 + H2O → CO2 + 4 H2 (typical overall stoichiometry with water adding).
    • Requires high-temperature reformer (~800°C) and a nickel-based catalyst; endothermic reforming; heat supplied by a burner.
    • Product gas typically contains ~80% H2 and ~20% CO2/CO before shift/conversion.
  • Water-gas shift (WGS):
    • CO + H2O ↔ CO2 + H2; used to reduce CO content and increase H2 yield.
    • Performed in two stages often: high-temperature shift (HTS, ~350–400°C, Fe-Cr or similar catalysts) and low-temperature shift (LTS, ~200°C, Cu-Zn catalysts).
  • Autothermal reforming (ATR):
    • CH4 + 1/2 O2 → CO2 + 2 H2 (and other products); combines reforming with partial oxidation in one reactor;
    • introduces nitrogen in the reformate due to air; hydrogen content is typically lower than SR, with higher CO if not cooled properly.
  • Partial oxidation (POX):
    • CH4 + O2 → CO2 + 2 H2; no external heat input required; gas contains more nitrogen and CO due to the oxidizing conditions; hydrogen content is generally lower than SR.
  • Autothermal reforming vs steam reforming: gas quality (hydrogen content) varies; SR provides highest hydrogen content (≈80%) with little to no inert nitrogen, while POX introduces inert N2 and CO; ATR lies in between.
  • Gas-cleaning sequence for PEM feed:
    • Desulfurization (to remove sulfur compounds before reforming).
    • Reforming (SR/ATR/POX) to generate a hydrogen-rich gas.
    • Shift conversion (HTS/LTS) to convert CO to CO2 and produce additional H2.
    • Gas-cleanup step (SeOx) to reduce residual CO to levels acceptable for PEM (CO ≤ ~10 ppm).
    • Final polishing to ensure minimal contaminants (S, halogens, heavy metals) that could degrade membranes or catalysts.
  • Gas quality and temperature dependence: as the operating temperature decreases (toward PEM ranges), the requirement for gas purity increases (CO tolerance becomes tighter) due to adsorption/desorption dynamics on Pt surfaces.
  • Practical example (4 kW reformer, ZBT Duisburg):
    • Hydrogen production capacity around 4 kW; can power a fuel cell stack of ~1.5–2 kW electrical output.
    • Product gas around 80% H2 across a broad load range; CO ~0.6% at full load; CH4 remaining ~1%; total CO2 and H2O in product gas.
    • Reformer efficiency (stand-alone) > 75% at full load; overall system including burner efficiency influences overall energy balance.

System integration: from reformer to PEM fuel cell stack (illustrative example)

  • Functional schematic for natural gas reforming to PEM feed:
    • Desulfurization unit to remove sulfur-containing compounds.
    • Reforming stage (SR, ATR, or a mix) with heat supplied by a burner to provide endothermic heat.
    • Shift conversion (HTS then LTS) to maximize hydrogen and reduce CO.
    • Gas-cleaning stage (selective oxidation to reduce CO to CO2 to meet PEM tolerances, e.g., CO < 10 ppm).
    • Feed to PEM fuel cell stack (hydrogen-rich gas).
  • Practical demonstration project:
    • A 4 kW hydrogen reformer developed at ZBT Duisburg to supply a 1.5–2 kW PEM stack; includes reformer burner, heat exchangers, shift converter, and selective oxidation.
    • Measured reformer outputs show ~80% H2 in product gas across load range; CO around 0.6% at full load; methane remainder around 1% at peak load.
    • Reforming efficiency > 75% (steam reforming conditions) with post-reform gas cleaning improving purity for PEM feed.

Stationary fuel-cell CHP applications and performance benchmarks

  • KWK (Kraft-Wärme-Kopplung) or micro-CHP contexts:
    • Various manufacturers offer micro-CHP fuel-cell systems around 1 kW electrical output based on PEM or SOFC; typical electrical efficiency ranges between 30–45% for standalone electricity generation.
    • Systems designed for domestic energy supply, with heat recovery providing significant thermal energy, raising total (electrical + thermal) efficiency up to 80–90% or higher in some configurations.
    • Some systems claim total efficiency up to ~85–90% with integrated heat recovery; long-term economic viability remains challenging due to high capital costs.
  • Larger scale CHP and industrial power plants:
    • SOFC systems and high-temperature fuel cells can achieve substantially higher electrical efficiencies, with hybrid configurations (e.g., SOFC with gas turbines) achieving electrical efficiencies above 60% and even above 70–75% in gas-turbine hybrids.
    • In many configurations, micro-CHP units can operate more efficiently due to favorable partial-load operation compared to conventional power plants or engines.
  • Comparative emissions (stationary fuel cells vs conventional technology):
    • Emissions for PEM fuel cells (CO, NMHC, NOx) can be negligible relative to conventional internal combustion engines and gas turbines; some data from DLR shows near-zero emissions for CO, NMHC, and NOx under certain operating conditions.
    • Relative environmental benefits include very low emissions when operated on hydrogen or highly clean reformate gas.
  • Efficiency and performance across scales (from small to large installations):
    • At small scales (kW range), PEM and PAFCs offer modularity and quick start-up advantages; at larger scales, MCFC and SOFC-based systems can leverage higher efficiencies and heat recovery.
    • The general trend is: higher temperatures (MCFC/SOFC) enable higher electrical efficiencies in combined cycles with turbines; lower-temperature PEM may provide lower electricity efficiency but superior control and integration for CHP with heat recovery.

Practical engineering and design considerations

  • Materials and manufacturing challenges:
    • Fuel-cell performance is strongly influenced by the choice of electrolytes and catalysts; materials science remains a core challenge (durability, poisoning resistance, temperature compatibility).
    • In PEM, membrane hydration is critical; membranes need to be thin (10–15 μm in automotive) to reduce ohmic losses while maintaining adequate moisture.
    • Bipolar plates and GDLs are often produced with injection-molded polymer composites to reduce cost and enable complex channel geometries for gas distribution.
  • Gas purity and system reliability:
    • Gas feed quality is a critical driver of lifetime and performance; lower-temperature systems (e.g., PEM) require much purer hydrogen (CO ≤ ~10 ppm) compared to high-temperature systems (e.g., PAFC, MCFC).
    • Sulfur compounds and particulates must be removed upstream to avoid catalyst poisoning and membrane degradation.
  • System integration architectures:
    • A fuel cell stack by itself produces electrical energy; in stationary CHP, the exhaust heat is captured for space heating or hot water, greatly increasing overall system efficiency.
    • In automotive applications, stacks are designed in large series, with per-cell voltages around 0.6–0.8 V under load; hundreds of cells in series yield usable voltages for propulsion systems.
  • Economic considerations and market uptake:
    • Investment costs for fuel-cell stacks and balance-of-plant components remain a key barrier to widespread adoption in residential and commercial markets.
    • Despite high efficiencies and low emissions, total cost of ownership (CAPEX and OPEX) must be favorable for broad deployment; ongoing R&D aims to reduce costs via manufacturing scale, materials, and system integration improvements.
  • Real-world submarine and vehicle applications:
    • Siemens and related research have developed stacks for submarines with high energy density and long duty cycles; stacks in such contexts demonstrate high reliability and fuel-flexible operation via reformate gas.

Hydrogen supply, storage, and energy density considerations

  • Hydrogen sources and storage challenges:
    • Green hydrogen (electrolysis powered by renewables) is ideal for clean energy but currently energy-intensive and cost-sensitive.
    • Reforming of hydrocarbons (natural gas, LPG, gasoline, diesel, biofuels) is a practical approach to hydrogen production but requires gas-cleaning and CO management.
  • Storage and volumetric energy density considerations:
    • Hydrogen storage options: compressed gas (CNG, typical 200–700 bar), liquid hydrogen, or solid-state stores (not covered in depth here).
    • Volumetric energy densities (typical order): liquids and hydrocarbons provide the highest volumetric energy densities; compressed/liquefied hydrogen provides lower densities per unit volume than hydrocarbons, complicating storage for mobile applications but not for stationary use.
  • Comparative energy densities (typical values given in the talk):
    • Gasoline (gasoline energy density by volume): around 31–32 MJ/L; Diesel ~35 MJ/L; Liquid fuels offer high energy density per volume.
    • Hydrogen (gas, compressed 700 bar): roughly 1.2–1.4 MJ/L (approximate, depending on pressure and temperature), much lower than hydrocarbon fuels, presenting storage challenges for mobile applications.
    • CNG (~200 bar): around 2.49 MWh/m^3; Liquid hydrogen ~2.4 MWh/m^3; Gasoline ~8.9 MWh/m^3; Diesel ~9.99 MWh/m^3; These figures illustrate the relative volumetric density differences.
  • Practical observations:
    • Conventional fuels (gasoline, diesel) offer compact, high-energy density storage; hydrogen requires bigger volume or higher pressure to meet similar energy payloads.
    • Energy carriers like methanol or other alcohols offer a compromise: can be reformatted to hydrogen with somewhat easier storage and handling characteristics, but lower energy density than pure hydrocarbons.
  • Implications for system design:
    • For mobile applications, the need for compact and lightweight storage drives ongoing research toward higher-pressure tanks, cryogenic storage, or on-site reforming to adapt to the energy density constraints of hydrogen.
    • For stationary applications, energy density is less critical than reliability, fuel sourcing, and heat integration; reforming-based hydrogen supply from natural gas can be a practical approach.

Cleanliness and hydrogen purity implications for different fuel-cell types

  • Relationship between operating temperature and gas purity requirements:
    • Lower temperatures (e.g., PEM at ~80°C) necessitate ultra-pure hydrogen with very low CO (< 10 ppm) to prevent catalyst poisoning and membrane degradation.
    • Higher-temperature systems (e.g., PAFC at ~200°C, MCFC, SOFC) can tolerate higher CO levels (e.g., PAFC up to ~1% CO in gas) but still benefit from reduced impurities.
  • Summary: as operation temperature drops, purity requirements tighten; gas-cleaning steps become more critical for PEM and other low-temperature cells.

Key practical metrics and constants highlighted in the talk

  • Faraday constant:
    F=96487extC/molF = 96487 ext{ C/mol}
  • Number of electrons transferred in the hydrogen oxidation reaction:
    n=2n = 2
  • Example catalytic and diffusion processes influenced by gas diffusion layers (GDL) and bipolar plates; the membrane acts as the primary electrolyte with porphyrin-like catalysts on both sides.
  • Typical single-cell voltage and performance data:
    • Open-circuit voltage around ~1.0 V per cell (not equal to ideal or thermoneutral values).
    • A typical single cell may deliver ~0.6–0.8 V under practical load, with power depending on current and active area.
    • Stacks (hundreds of cells) yield practical voltages in the tens to hundreds of volts and power in the kilowatt range.

Connections to broader themes and real-world relevance

  • Fuel cells offer a modular, scalable energy conversion platform suitable for a wide range of power needs—from micro-CHP in homes to large stationary power plants and mobile applications (vehicles, ships, submarines).
  • They provide potential for high efficiencies and low emissions, especially when hydrogen is produced from clean sources.
  • In stationary CHP, fuel cells can exceed the performance of conventional power plants in certain regimes due to superior part-load efficiency and heat recovery potential.
  • The barriers to widespread adoption include high capital costs, the need for robust hydrogen supply chains, and the development of durable, cost-effective materials and manufacturing processes.
  • Reforming-based hydrogen production remains a practical bridge technology for fleets and stationary systems that rely on existing fossil fuel infrastructure while transitioning toward cleaner energy carriers.

Quick recall prompts (for exam-style review)

  • Name the four main loss mechanisms in a fuel cell polarization curve and what they correspond to physically.
  • Write the thermodynamic expressions for U_th upper and lower, and E^0 upper and lower with the corresponding ΔH and ΔG values.
  • Derive the ideal efficiency for a fuel cell under upper heating value using E^0 and U_th, and compare with the lower heating value case.
  • What are the main reforming pathways to generate hydrogen from hydrocarbons, and how do their hydrogen contents compare?
  • What CO tolerance levels are typical for PEMFC and PAFC, and why does this matter for the reforming train?
  • Describe the seven-layer structure of a single PEM fuel cell and the role of GDLs, catalysts, and bipolar plates.
  • Explain why partial-load operation often yields higher efficiency in a fuel cell stack compared to a conventional internal combustion engine.
  • Compare volumetric energy densities of gasoline, diesel, propane LPG, CNG, liquid hydrogen, and compressed hydrogen at typical storage conditions.

Note on sources and context

  • The material reflects a university-level lecture on fuel cells, combining historical development, thermodynamics, electrochemistry, and system engineering aspects, with real-world examples from industry partners (Siemens, ZBT Duisburg) and aerospace/spaceflight heritage (NASA).
  • While data points are specific to the lecture, the general relationships (thermodynamic voltages, overpotentials, polarization curve regions, reforming chemistry, and system architecture) are representative of standard fuel-cell theory and practice.