ABO Study Guide Notes: Exhaustive Edition

Introduction and Passing the ABO

The American Board of Opticianry (ABO) exam represents the minimum required knowledge to begin a career as an optician. However, it does not prepare an individual for the actual day-to-day work, as it does not cover sales, specialty eyewear, insurance or vision care plans, business management, contact lenses, finishing, lab relations, repairs, or order processing. To pass the ABO, a candidate must grasp fundamental concepts through a combination of several study methods. Memorization involves good old-fashioned study until concepts are committed to memory using flashcards and quizzes. Practice requires working through provided examples five to fifteen times until patterns become clear. Visualization involves mentally picturing concepts in practice and in three dimensions. Drawing is critical; candidates must use scrap paper to draw out prism questions to ensure accuracy. Finally, the process of elimination should be applied to the multiple-choice questions to arrive at the correct answer.

Ocular Anatomy: The Structure and Fluid Chambers of the Eye

The human eye is composed of three primary layers. The fibrous tunic consists of the sclera and the cornea. The vascular tunic, responsible for nourishment, includes the iris, the choroid, and the ciliary body. The nervous tunic is the innermost layer of photoreceptors and neurons, consisting of the retina. This neural layer contains rods, which allow for vision in twilight and dimly lit rooms but do not discriminate color, and cones, which discriminate colors but require brighter light. There are approximately 120×106120 \times 10^6 rods located toward the outside of the retina and about 6×1066 \times 10^6 cones concentrated near the center of the macula. The highest concentration of cones is found at the fovea, the center of the macula, where light focuses in a healthy eye. The optic disc, where the optic nerve enters the eye, contains no receptor cells and is known as the "blind spot."

The eye contains three fluid-filled chambers. The anterior chamber is located between the cornea and the iris. The posterior chamber is situated between the iris and the lens. Both contain aqueous humor, a watery fluid produced by the ciliary body that maintains intraocular pressure (IOP) and provides nutrients to the lens and cornea. It drains through the Canal of Schlemm. The vitreous chamber, found between the retina and the lens, is filled with vitreous humor, a thicker gel-like substance that maintains the eye's shape.

Detailed Anatomy: Cornea and External Structures

Light enters the eye through the transparent, dome-shaped cornea, which consists of five distinct layers. The outermost layer is the epithelium, which rests on Bowman’s membrane. Bowman’s membrane acts as a protective barrier. The stroma, located between the two membranes, accounts for 90%90\% of the cornea's thickness. Descemet’s membrane separates the stroma from the innermost layer, the endothelium. The endothelium is responsible for removing water from the cornea to keep it clear. A memory hint for these layers is that "B" comes before "D" and "endo" implies the end/innermost layer.

External structures include the palpebrae (eyelids) and the medial canthus, where the lids meet near the nose, and the lateral canthus, where they meet toward the ear. Eyelashes along the palpebral margins filter debris. Meibomian glands along the inner margin secrete a liquid that prevents the eyelids from sticking and contributes to the tear film. The fornix is located behind the palpebra along the sclera where the two layers of conjunctiva join. The lacrimal gland, located inside the orbit above the lateral canthus, produces the bulk of tears. Tears drain through the lacrimal puncta (pores at the medial canthus) into lacrimal canals, then to the lacrimal sac and nasal cavity. The lacrimal caruncle at the medial canthus also produces lubricating liquid. The limbus is the region where the cornea blends into the sclera. The palpebral conjunctiva covers the eyelids, while the ocular or bulbar conjunctiva covers the exposed portions of the eye.

Oculomotor Muscles and Accommodation

Six muscles control eye movement: the Lateral Rectus (rotates eye laterally/outward), Superior Rectus (looks up), Medial Rectus (rotates eye medially/inward), Inferior Rectus (looks down), Inferior Oblique (rolls eye up and to the side), and Superior Oblique (rolls eye down and to the side). The Superior Oblique passes through a bony spur called the Trochlea to facilitate rotation.

Accommodation is the process of focusing on objects based on distance. The closer an object, the more power is required from the crystalline lens. The ciliary body, attached via fibrous strands called zonules, controls this. When the ciliary body contracts, the zonules relax, allowing the lens to thicken and add power for near vision. When the ciliary body relaxes, the zonules contract, drawing the lens outward to make it thinner for distance vision. The iris controls light via two muscles: the dilator (opens the iris) and the sphincter (closes the iris), changing pupil size from 2 mm2\,mm to 8 mm8\,mm.

Refractive Errors of the Human Eye

An emmetropic eye focuses light rays perfectly on the retina for crisp sight without correction. Common errors include:

  • Presbyopia: The crystalline lens loses the ability to change shape for accommodation, remaining in a flatter, less plus shape; it requires magnification for near work.
  • Simple Myopia: Light rays focus at a single point in front of the retina because the eye is too long. Nearsighted individuals see well at near but require minus lenses for distance.
  • Simple Hyperopia: Light rays focus toward an imaginary point beyond the retina because the eye is too short. Farsighted individuals see well at distance but require plus lenses for near work.
  • Astigmatism: Resulting from a misshapen, cylindrical cornea with different curves/powers.     - Simple Myopic Astigmatism: Some rays fall short of the retina while others fall on the fovea; corrected with toric lenses where one meridian has 0.000.00 power.     - Simple Hyperopic Astigmatism: Some rays focus beyond the retina while others fall on the fovea.     - Compound Myopic Astigmatism: All rays fall short of the retina at different points; objects appear distorted and blurred.     - Compound Hyperopic Astigmatism: All rays focus beyond the retina at different points.     - Mixed Astigmatism: Some rays fall ahead of the retina and others focus beyond it, resulting in poor vision at all distances.

Basic Optical Principles and the Index of Refraction

Light is radiant energy acting as both a particle and a wave, traveling at a speed of 186,000 miles per second186,000\,\text{miles per second}. The visible spectrum lies between 400 nm400\,nm and 700 nm700\,nm. Ultraviolet (UV) is below 400 nm400\,nm, and infrared (IR) is above 750 nm750\,nm. The order of colors is ROY G BIV (red, orange, yellow, green, blue, indigo, violet). Refraction is the change in speed and direction of light as it passes from one transparent medium to another at an angle other than perpendicular.

The index of refraction, denoted as nn, indicates how much a material slows and redirects light. A higher nn allows for a thinner lens to produce the same power. Common indices include 1.498,1.523,1.586,1.60,1.67,1.498, 1.523, 1.586, 1.60, 1.67, and 1.741.74. The formula for diopter power is: D=1fD = \frac{1}{f} where ff is the focal length in meters. Conversely: f=1Df = \frac{1}{D} Example: If focal length is 0.50 m0.50\,m, then 1/0.50=2.00 D1 / 0.50 = 2.00\,D. A prism diopter (1.00 Δ1.00\,\Delta) produces the appearance of a 1 cm1\,cm shift at a distance of 1 m1\,m.

Lenses as Prisms and Lens Power Formulas

All ophthalmic lenses are essentially two prisms. A plus lens consists of two prisms stacked base-to-base, causing light to converge. A minus lens consists of two prisms stacked apex-to-apex, causing light to diverge. Modern lenses are meniscus-shaped. In a prism, light always bends toward the base, while the perceived image shifts toward the apex.

The Nominal Lens Formula is used for the exam: DL=D1+D2D_L = D_1 + D_2 where DLD_L is total power, D1D_1 is front surface power, and D2D_2 is back surface power. Example: If D1=+8.00D_1 = +8.00 and D2=−10.00D_2 = -10.00, then DL=−2.00D_L = -2.00.

Vogel's Rule for Base Curves:

  • For Plus Rx: Base Curve=Spherical Equivalent+6.00 D\text{Base Curve} = \text{Spherical Equivalent} + 6.00\,D
  • For Minus Rx: Base Curve=0.5×(Spherical Equivalent)+6.00 D\text{Base Curve} = 0.5 \times (\text{Spherical Equivalent}) + 6.00\,D To find the Spherical Equivalent: Add exactly half the cylinder power to the sphere power. Example: For a −4.00−2.00×98-4.00 - 2.00 \times 98 Rx, the spherical equivalent is −4.00+(−1.00)=−5.00-4.00 + (-1.00) = -5.00. Using Vogel's rule: 0.5×(−5.00)+6.00=+3.50 D0.5 \times (-5.00) + 6.00 = +3.50\,D.

Lens Form: Sphere, Cylinder, and Axis

A spherical lens produces a single focal point. A cylindrical lens has two different curves (like a football cut lengthwise) to correct astigmatism, producing variable focus. Lenses correcting astigmatism are toric or sphero-cylindrical. Axis (00 to 180180) denotes the position of these curves. Aspheric lenses feature a front surface that tapers away from the center to provide a thinner lens and reduced distortion. Flat transposition switches prescriptions between plus and minus cylinder forms:

  1. Add cylinder to sphere algebraically.
  2. Change the cylinder sign.
  3. Move axis by 90∘90^{\circ} (staying between 00 and 180180). Example: −1.75−1.25×67-1.75 - 1.25 \times 67 becomes −3.00+1.25×157-3.00 + 1.25 \times 157.

The Optical Cross graphically represents power and position. Cylinder value is the power difference between the two principal meridians. For an Rx shown as −6.00-6.00 at 45∘45^{\circ} and −9.00-9.00 at 135∘135^{\circ}, in minus cylinder form it is −6.00−3.00×45-6.00 - 3.00 \times 45. In plus cylinder form, it is −9.00+3.00×135-9.00 + 3.00 \times 135.

Working with Prism and Prentice’s Formula

Prism alters the perceived image for patients whose eyes do not see things in the same place. Prentice’s Formula determines the amount of prism created by decentration: P=hcm×DP = h_{cm} \times D where PP is prism diopters, hcmh_{cm} is the decentration distance in centimeters (divide mmmm by 1010), and DD is the lens diopter power in the meridian being checked.

Compounding and Canceling Rules:

  • Canceling: BU/BU,BD/BD,BI/BOBU/BU, BD/BD, BI/BO
  • Compounding: BU/BD,BI/BI,BO/BOBU/BD, BI/BI, BO/BO Example: Rx R:−2.00R: -2.00, L:−3.00L: -3.00. Monocular PDs are 32/3432/34, frame PD is 7070 (35/3535/35 split). Right error: 35−32=3 mm=0.3 cm35 - 32 = 3\,mm = 0.3\,cm. P=0.3×2.00=0.6 BIP = 0.3 \times 2.00 = 0.6\,BI. Left error: 35−34=1 mm=0.1 cm35 - 34 = 1\,mm = 0.1\,cm. P=0.1×3.00=0.3 BIP = 0.1 \times 3.00 = 0.3\,BI. Total prism: 0.6 BI+0.3 BI=0.9 BI0.6\,BI + 0.3\,BI = 0.9\,BI (compounds).

Splitting Prism

Prism splitting balances the prescription for better weight and cosmetic appearance when prism is prescribed for one eye only. Rules include: checking with the doctor, dividing the prism by 22, placing one part in each eye, and maintaining original direction while following compounding rules.

  • Example 1: Rx needs 6.00 BU6.00\,BU OS. Splitting: 3.00 BD3.00\,BD OD and 3.00 BU3.00\,BU OS (compounds to 6.00 BU6.00\,BU OS effect).
  • Example 2: Rx needs 5.00 BI5.00\,BI OD. Splitting: 2.50 BI2.50\,BI OD and 2.50 BI2.50\,BI OS (compounds to 5.005.00 total effect).
  • Example 3: Rx needs 4.00 BD4.00\,BD and 3.00 BO3.00\,BO OD. Splitting: 2.00 BD,1.50 BO2.00\,BD, 1.50\,BO OD and 2.00 BU,1.50 BO2.00\,BU, 1.50\,BO OS.

Lens Materials and Characteristics

  • Abbe Value: Describes how prone a lens is to chromatic aberration. Higher values (forties/fifties) are better; lower values (thirties) create more distortion.
  • Specific Gravity: Density relative to water (>1>1 is denser).
  • Crown Glass (n=1.53,Abbe=58n=1.53, \text{Abbe}=58): Excellent optics and scratch resistance; heavy and unsafe.
  • Plastic/CR-39 (n=1.49,Abbe=58n=1.49, \text{Abbe}=58): Low cost, light, but breaks easily if drilled.
  • Polycarbonate (n=1.586,Abbe=31n=1.586, \text{Abbe}=31): Safety standard for children/one-eyed patients; thin and light but poor optics (31 Abbe31\,Abbe).
  • Trivex (n=1.53,Abbe=43−45n=1.53, \text{Abbe}=43-45): Great optics, lightweight, and safe; thicker than poly.
  • High Index (1.60,1.67,1.741.60, 1.67, 1.74): Thinnest options for high prescriptions (±4.00\pm 4.00 to ±15.00\pm 15.00); 1.741.74 is the highest plastic index.

Golden Rule: The shorter the radius, the steeper the curve; the steeper the curve, the higher the power; the higher the power, the thicker the lens. In minus lenses, larger eyewires increase edge thickness. In plus lenses, larger eyewires increase center thickness.

Lens Options and Enhancements

Anti-Reflective (AR) Coatings improve light transmission, provide scratch protection, and include hydrophobic (fog-resistant), oleophobic (oil-resistant), and anti-static layers. They are essential for driving at night. Photochromics darken in UV light; AR coatings increase their sensitivity. Polarization involves a filter sandwich that blocks horizontal light waves (glare) while allowing vertical waves. Tinting types include solid, gradient (dark top to light bottom), and double gradient (two colors). UV protection is standard if it blocks 95%−98%95\%-98\% of rays. Tint depths range from 0.50.5 (barely visible) to 3.53.5 (dark sunglass).

Multifocals, Progressives, and Slab Off

  • Multifocals: Lined bifocals (ST 28 is industry standard) and trifocals (e.g., ST 7×287 \times 28). Executives are two lenses split and fused.
  • Progressives (PALs): Provide a continuous power build through an intermediate corridor. Fitting height and corridor length (shorter = faster power build) are key.
  • Slab Off (Bicentric Grinding): Corrects vertical imbalance in patients with anisometropia (unequal refractive power). Conventional slab-off is ground Base Up in the most minus/least plus lens in the 90∘90^{\circ} meridian. It is usually needed when imbalance reaches 1.5 D1.5\,D.

Specific Prescription Types and Conversions

  • Balance Lens: Used when a patient is blind in one eye; requires Polycarbonate or Trivex. Match the power using the spherical equivalent.
  • Vertex Distance: Distance from cornea to lens. More vertex distance always equates to more perceived plus power.
  • NVO/DVO: Near Vision Only (readers) vs. Distance Vision Only.
  • Reader Conversion: To create single vision readers from a distance Rx with an Add:     - For Near: Add the full Add power algebraically to the sphere.     - For Intermediate: Add half the Add power algebraically to the sphere.     Example: Distance −3.00-3.00, Add +2.00+2.00. Near readers: −1.00-1.00. Intermediate: −2.00-2.00.

Frame Anatomy and Frame Measurement (The Boxing System)

Frames are measured using the Boxing System:

  • A: Longest horizontal opening.
  • B: Longest vertical measurement.
  • DBL: Distance Between Lenses (bridge size).
  • ED: Effective Diameter (twice the distance from geometric center to furthest edge).
  • Frame PD: A+DBLA + DBL. Used to calculate lens decentration.
  • Temples: Types include Skull (95%95\% prevalence), Cable (wraps around ear), and Library/Sport (straight back). Standard length is 140 mm140\,mm.
  • Parts: Chassis (front), bridge, nose pads, guard arms, eyewire, end piece, and hinge.

Frame Materials and Fitting

Metals:

  • Monel: Nickel-based, inexpensive, easy to adjust, but can cause allergies.
  • Stainless Steel: Corrosion-resistant, strong, not 100% hypo-allergenic.
  • Titanium: Lightweight, 100% corrosion-proof, hypo-allergenic.
  • Beta-Titanium: Flexible memory metal.

Plastics:

  • Zyl (Cellulose Acetate): Most common, huge color range, but can dry out/become brittle.
  • Polyamide (Nylon): Chemical resistant, "Cold Insert" only.
  • Optyl: Memory plastic; maintains shape after heating/cooling.

The Fitting Triangle: The frame touches the head at three points: the bridge of the nose and the junction of each ear with the skull. Adjusting nose pads: move together to raise, spread to lower. Frontal angle follows nose contours; Splay angle adjusts for nose width from top view; Vertical angle accounts for pantoscopic tilt.

Standard (Bench) Alignment

A frame should be aligned before dispensing:

  1. Tighten all screws.
  2. X-ing: Correct lenses twisted about the bridge.
  3. Co-planar: Ensure lenses are on the same vertical plane.
  4. Skewed Bridge: Check for rotation around the bridge.
  5. Face-form: Positive (curves with face), Negative (curves away), or Neutral (flat). Positive is desired.
  6. Pantoscopic Tilt: Bottom of eyewires closer to face than top. Retroscopic is the opposite and incorrect.
  7. Temple Parallelism: "Flat surface touch test" (upside down).
  8. Open Temple Angle: Should be 90∘90^{\circ} to +2∘+2^{\circ}.
  9. Temple Fold Angle: Tips should not touch lens surfaces.

Measuring and Patient PDs

A Corneal Reflex Pupilometer (CRP) measures PD. Monocular PDs are taken from bridge to pupil for each eye (essential for PALs). Binocular PD is a single total number (used for lined multifocals). OC heights are dotting the pupil on the demo lens. Bifocal heights are measured to the lower eyelid. Trifocal heights are at the lower pupil margin. Progressive heights are at the center of the pupil.

Troubleshooting and Dispensing

When troubleshooting, compare the new pair to the patient's old pair. If a patient drops their head to see distance clearly, the PAL is fit too high. Spread nose pads or add pantoscopic tilt to lower.

  • Base Down Prism Reaction: Feeling like walking uphill, standing in a bowl, or objects stretched vertically.
  • Base Up Prism Reaction: Feeling like walking downhill, world seems convex, or vertical objects appear shorter.
  • Base In/Out Reaction: Objects appearing tilted or higher/lower.

Tools and Instrumentation

The Lensmeter (Marco LM-101): Measures lens power and orientation.

  • Focusing: Turn eyepiece counter-clockwise until stops, then clockwise until reticle clears. Set drum to +10.00+10.00, turn slowly toward minus until target is clear at 0.000.00.
  • Sphere Lines: Three thin parallel lines.
  • Cylinder Lines: Three thick parallel lines.
  • Prism Rings: Concentric circles denoting 1,2,3 Δ1, 2, 3\,\Delta.

Lens Clock: Measures sagittal depth of a lens to determine curve in diopters. Calibrated for n=1.53n=1.53. Can determine if a surface is spherical (00 movement when rotated) or toric (movement between minimum/maximum readings).

Regulations, Standards, and Safety

  • ANSI (American National Standards Institute): Z80.1 sets ophthalmic lens recommendations; Z87.1 sets safety standards.
  • OSHA: Workplace safety agency.
  • FDA: Classifies glasses as medical devices; requires impact testing.
  • Drop Ball Test: A 5/8-inch5/8\text{-inch} steel ball (0.56 oz0.56\,oz) dropped from 50 inches50\,inches.
  • Safety Lenses:     - Basic Impact: 3.00 mm3.00\,mm thick (2.5 mm2.5\,mm if over +3.00 D+3.00\,D). 1-inch1\text{-inch} ball drop test.     - High Impact: Minimum 2.0 mm2.0\,mm thickness. Must be Polycarbonate or Trivex. Pass velocity test (wide-range 1/4-inch1/4\text{-inch} ball shot at 150 ft/s150\,ft/s). Marked with a "+" sign.
  • Duty to Warn: Opticians have a legal liability to inform patients of the safety benefits of Polycarbonate or Trivex, especially for high-risk users.