Lab for 1st CPE
Pre-Procedure Assessment and Patient Identification
Clinical Communication and Documentation Review:
The Clinical Performance Examination (CPE) scenario is initiated using the ISBAR framework (Introduction, Situation, Background, Assessment, Recommendation) along with the physician's written order.
Patient chart discrepancies must be actively identified and reconciled (e.g., verifying chart records labeled under alternate names such as Justin Brown against the present client).
Patient Identity Verification:
Active confirmation of the patient's full name and date of birth is required prior to initiating any clinical intervention.
Client Name: Kelly Patel.
Client Date of Birth: Recorded as (referenced subsequently in verification checks as ).
Allergy Assessment:
Screening for adhesive allergies: Specifically assess for allergies or sensitivities to clinical tape.
Screening for material allergies: Specifically verify the absence of a latex allergy.
Extremity Assessment and Site Selection:
Identify patient extremity preference (client specified preference for the right arm).
Evaluate the selected limb for contraindications: Confirm the absence of recent surgical history, arteriovenous (AV) fistulas for dialysis access, prior vascular or surgical interventions, trauma, or active open wounds.
Establish informed consent by explaining the procedure and confirming verbal assent prior to gathering supplies.
IV Cannula Insertion Procedure and Aseptic Technique
Medication Preparation Needle Protocol:
When drawing up or aspirating medications or diluents from a medication cart or vial using a syringe and needle, the needle does not need to be changed prior to adding it to an infusion system if it is solely used for aspiration and is not directly injected into patient tissue.
Infection Control and Personal Protective Equipment (PPE):
Perform thorough hand hygiene (hand washing) prior to contact with clean supplies.
Don clean examination gloves.
CPE Requirement: Gloves must physically be donned; vocalization without physical donning is impermissible when supplies are provided.
Tourniquet Application and Vein Inspection:
Apply the tourniquet proximal to the anticipated venipuncture site on the chosen extremity.
The tourniquet must be sufficiently tight to occlude venous return, dilate target veins, and enhance visibility and palpation.
Inspect and palpate the tract of the vein to determine suitable straightness and gauge.
Site Antisepsis and Aseptic Maintenance:
Cleanse the selected venipuncture site thoroughly using an alcohol swab.
Strict Aseptic Rule: Once the site is cleansed, it must never be touched, re-palpated, or fanned with hands or objects.
Allow the site to air-dry completely through natural evaporation. (In clinical assessment scenarios, such as at Gillen Hospital, deviations from natural air-drying violate aseptic technique).
Cannula Preparation and Geometry:
While the site air-dries, prime the extension connecting cord/tubing with a sterile saline flush.
Remove the protective needle cap from the peripheral intravenous catheter (PIVC).
Orient the cannula with the bevel facing directly upwards (bevel-up).
Insert the needle through the skin into the vein at an angle of to .
Advancement and Venous Access Confirmation:
Observe the flashback chamber for primary blood return (backflow) confirming entry into the vessel lumen.
Lower the insertion angle slightly and advance the device halfway through the vein.
Slide and push the plastic catheter forward into the vein off the needle stylet; do not advance the sharp metal needle stylet further into the vessel lumen.
Release and remove the venous tourniquet.
Post-Insertion Line Securing, Flushing, and Labeling
Extension Set Attachment:
Maintain manual occlusion over the vein proximal to the catheter tip to limit blood loss.
Connect the pre-primed extension tubing cord directly to the catheter hub.
Because the connection components are packaged sterilely, swabbing the internal sterile junction with alcohol prior to initial connection is not required.
Verification of Catheter Patency:
Do not instill the full () syringe volume immediately.
Aspirate slightly to observe for blood return (flashback), verifying endovascular placement.
Instill a small volume of normal saline flush to confirm patency, absence of resistance, and absence of subcutaneous swelling (infiltration).
Site Dressing and Mechanical Stabilization:
Ensure the skin surrounding the insertion site is thoroughly dry before applying dressings, as moisture prevents adhesive adherence.
Secure the catheter firmly with tape and cover the insertion site with a transparent semipermeable membrane dressing (Tegaderm).
Sequencing Warning: The catheter must be stabilized and secured before disconnecting syringes or manipulating extension sets; attempting manipulation on an unsecured line carries a high risk of accidental dislodgement and catheter pull-out.
Dressing Labeling Requirements:
Document the following information directly onto the dressing label:
Date of insertion.
Time of insertion.
Clinician signature / initials.
Catheter gauge size: Identify gauge by standard color coding ( corresponds to pink; distinct from a blue catheter).
Intravenous Push (IV Push) Medication Administration: Ketorolac
Pre-Administration Verification and Education:
Review the physician's orders: Ketorolac IV push ordered for pain management.
Re-verify patient identification using two unique identifiers (Full Name: Kelly Patel, DOB: ).
Deliver patient education regarding the drug indication, expected outcomes, and potential side effects prior to administration (students may reference Unit 3 medication cards during CPE examinations).
Order of Systemic Administration:
Administer intravenous push (IVP) medications before hanging secondary intravenous piggyback (IVPB) infusions.
Flushing and Administration Technique (Push-Pause Pulsatile Method):
Disinfect the injection hub thoroughly using an antiseptic wipe.
Attach the prefilled normal saline flush syringe.
Flush the line using a pulsatile "push-stop-push-stop" technique (flushing up to ) to generate turbulent clearance within the lumen.
Scrub the access hub again with antiseptic.
Attach the medication syringe containing the calculated dosage of Ketorolac ().
Administer the medication slowly over the clinically indicated duration derived from dosage calculations.
During active administration, assess patient tolerance by asking: "Do you feel any burning sensation? Do you feel any pain while I'm giving the medication?"
Scrub the hub with antiseptic following medication injection.
Attach the secondary post-medication flush syringe.
Administer the post-medication flush using the "push-stop-push-stop" pulsatile method. The initial volume equivalent to the medication volume must be pushed at the same slow rate as the medication itself, followed by the remaining flush.
Post-Administration Pain Monitoring:
Re-evaluate and assess patient pain levels at following intravenous push administration.
Intravenous Piggyback (IVPB) Medication Administration: Vancomycin
Order and Equipment Verification:
Review order: Vancomycin in IVPB (or Keppra IVPB depending on the clinical scenario; unlabelled bags must be clarified or verbalized).
Obtain secondary infusion tubing set, primary administration line, extension hook/hanger, and intravenous infusion control device/pump.
Secondary Tubing Preparation and Priming:
Ensure the roller clamp on the secondary tubing is clamped completely closed prior to piercing the medication port.
Maintain strict sterility of the spike; avoid touching the spike shaft or tip.
Spike the IVPB medication bag.
Compress the drip chamber until it is filled to approximately (one-quarter) of its total capacity.
Slowly open the roller clamp to prime the entire length of the secondary tubing, completely purging all air bubbles until fluid flows steadily throughout.
Close the roller clamp securely once priming is complete.
Hydrostatic Pressure and Line Architecture:
Connect the primed secondary tubing to the upper (proximal) Y-port (the first port above the infusion control mechanism or pump) on the primary administration set.
Scrub the Y-port hub with antiseptic before making the connection.
Lower the primary infusion bag below the secondary medication bag using the metal extension hook/hanger.
Physical Principle: The secondary bag must hang physically higher than the primary bag so hydrostatic pressure keeps the primary check valve closed, ensuring the piggyback infuses completely before primary fluid resumes.
Infusion Rate Regulation and Drop Counting:
Open both the primary line clamp and the secondary line clamp.
Calculate the appropriate drop rate ( or ) based on total volume () and prescribed duration ( or ).
Regulate flow via the roller clamp while observing drops in the drip chamber.
Count drops using a watch for (60 seconds) to ensure accurate flow calibration.
Post-Procedure Assessment, Monitoring, and Documentation
Patient Safety and Adverse Reaction Monitoring:
Inform the patient that the IV antibiotic piggyback will run over a duration of .
Instruct the client to immediately report any adverse signs or symptoms, including localized discomfort, cutaneous rash, pruritus, or dyspnea (difficulty breathing), indicative of hypersensitivity or severe allergic reactions.
Clinical Performance Documentation Standards:
Immediately upon completion of clinical actions, enter full documentation:
Peripheral IV insertion: Date, time, anatomical site, catheter gauge (), number of insertion attempts, and patient tolerance.
IV push administration: Drug name (Ketorolac), dose (), route (IV push), baseline pain score, administration rate, and post-intervention assessment at .
IV piggyback infusion: Medication name (Vancomycin), dose (), volume (), administration route, start time, calculated flow rate, and patient response.
Clinical Performance Examination (CPE) Specific Guidelines and Practice Rules
Station Time Limits:
The complete procedural sequence—including assessment, cannulation, IV push, IV piggyback initiation, and documentation—is designated to be completed within a total testing duration of .
Cannulation Attempt Limits:
If the vein is missed on initial insertion, the maximum number of attempts allowed is a single secondary attempt (maximum of 2 attempts total); repeated attempts (e.g., 3 to 5 attempts) are strictly prohibited.
If venipuncture fails on initial entry, adjust catheter trajectory or immediately transition to a second formal attempt.
Simulation Accommodations vs. Real Clinical Practice:
Gloves: Must be physically worn during the exam; vocalizing donning without wearing is marked as a failure.
Line Spillage: While simulated tubing setups during examinations may allow specific manual adjustments over clean basins, real clinical practice requires complete containment to prevent fluid contamination and spillage.
Questions, Dialogue, and Procedural Clarifications
Dialogue on Glove Donning:
Prompt / Action: A student prepared to perform the procedure by verbally vocalizing that gloves were obtained.
Instruction / Clarification: In the CPE, vocalization of glove application is not permitted because physical gloves are supplied in the testing room; gloves must be physically donned on the hands.
Dialogue on Site Antisepsis and Contamination:
Prompt / Action: The venipuncture site was wiped with an alcohol swab, and the student immediately re-palpated the site with bare fingers.
Instruction / Clarification: Once cleansed with alcohol, the insertion site must not be touched again under any circumstances. It must never be fanned by hand; it must be permitted to air-dry completely.
Dialogue on Swabbing Sterile Tubing Connections:
Question: Is it necessary to swab the catheter hub with alcohol before connecting the extension tubing?
Response: No; because the extension tubing and cannula hub come freshly packaged in a sterile state, an alcohol swab is unnecessary for that initial connection.
Dialogue on Patency Flushing Volume:
Question: Should the entire flush be injected at once to check patency?
Response: No; instill only a small volume (a little bit) to observe whether fluid flows freely without resistance or swelling, and aspirate slightly for a blood flashback to confirm intravascular placement.
Dialogue on Tegaderm Dressing Placement Sequencing:
Question: Is the Tegaderm dressing placed before or after flushing the line?
Response: Check patency with a small volume first, ensure the skin is dry, and secure the site with tape and the Tegaderm dressing before performing full line manipulation or disconnecting flushes. Attempting to manipulate an unsecured line creates a high probability of catheter dislodgement.
Dialogue on Cannula Gauge Identification:
Question / Statement: A student identified the pink catheter as a .
Instruction / Clarification: The pink catheter is a . Gauge size must be recorded on the dressing label alongside date, time, and clinician initials.
Dialogue on Venipuncture Re-Attempt Limits:
Question: Can a student repoke the patient three to five times if a vein is missed?
Response: No; multiple repeated attempts are prohibited. A student is permitted only a second attempt.
Dialogue on IV Push vs. IV Piggyback Sequencing:
Question: Between the IV push and the IV piggyback, which is administered first?
Response: The IV push medication is always administered first, prior to hanging and setting up the secondary piggyback line.
Dialogue on Physical Gravity Setup for Secondary Infusions:
Question: Will the secondary piggyback drip if it is attached at the same height as the primary bag?
Response: No; the primary (main) IV bag must be hung lower using the extension hook. The secondary piggyback must hang higher than the primary line to establish the hydrostatic pressure gradient needed to pull fluid from the piggyback chamber.